Diagnostic buffer of module CP 342-5

Order No./ Description Component Version

6GK7 342-5DA03-0XE0 Hardware 2

- - - Firmware V 6.0.62

Boot Rom Firmware expansion V 1.0.9

Rack: 0
Slot: 8

Event 1 of 34: Event ID 16# F9C1:2416


Slave is in data transfer.
External error, Incoming event
(Coding: 16# F9C1 2416 0200 0000 0000 0000)

Event 2 of 34: Event ID 16# F9C1:2414


Slave is ready for data transfer.
The parameter assignment master has the PROFIBUS address: 2.
External error, Incoming event
(Coding: 16# F9C1 2414 0200 0000 0200 0000)

Event 3 of 34: Event ID 16# F9C1:2413


Actual configuration has changed.
The new configuration consists of: 48 inputs 8 outputs
External error, Incoming event
(Coding: 16# F9C1 2413 0200 0000 0000 3008)

Event 4 of 34: Event ID 16# F9C1:2413


Actual configuration has changed.
The new configuration consists of: 48 inputs 0 outputs
External error, Incoming event
(Coding: 16# F9C1 2413 0200 0000 0000 3000)

Event 5 of 34: Event ID 16# F9C1:0220


I/O enable by S7 CPU
External error, Incoming event
(Coding: 16# F9C1 0220 0200 0000 0000 0000)

Event 6 of 34: Event ID 16# F9C1:2412


Invalid configuration frame
Master configuration (number of inputs: 48, number of outputs: 8)
Slave configuration (number of inputs: 0, number of outputs: 0).
External error, Incoming event
(Coding: 16# F9C1 2412 0200 0000 3008 0000)

Event 7 of 34: Event ID 16# F9C1:2413


Actual configuration has changed.
The new configuration consists of: 0 inputs 0 outputs
External error, Incoming event
(Coding: 16# F9C1 2413 0200 0000 0000 0000)

Event 8 of 34: Event ID 16# F9C1:2415


Slave terminating data transfer.
External error, Incoming event
(Coding: 16# F9C1 2415 0200 0000 0000 0000)

Event 9 of 34: Event ID 16# F9C1:0221


I/O disable by S7 CPU
External error, Incoming event
(Coding: 16# F9C1 0221 0200 0000 0000 0000)

Event 10 of 34: Event ID 16# F9C1:2416


Slave is in data transfer.
External error, Incoming event
(Coding: 16# F9C1 2416 0200 0000 0000 0000)

Event 11 of 34: Event ID 16# F9C1:2414


Slave is ready for data transfer.
The parameter assignment master has the PROFIBUS address: 2.
External error, Incoming event
(Coding: 16# F9C1 2414 0200 0000 0200 0000)

Event 12 of 34: Event ID 16# F9C1:2413


Actual configuration has changed.
The new configuration consists of: 48 inputs 8 outputs
External error, Incoming event
(Coding: 16# F9C1 2413 0200 0000 0000 3008)

Event 13 of 34: Event ID 16# F9C1:2413


Actual configuration has changed.
The new configuration consists of: 0 inputs 0 outputs
External error, Incoming event
(Coding: 16# F9C1 2413 0200 0000 0000 0000)

Event 14 of 34: Event ID 16# F9C1:0214


PG command causes module restart
External error, Incoming event
(Coding: 16# F9C1 0214 0000 0000 0000 0000)

Event 15 of 34: Event ID 16# F9C1:0225


Module is passive bus node
Restricted functions:
No SEND/RECEIVE mode, no PG mode on SIMATIC NET PROFIBUS
External error, Incoming event
(Coding: 16# F9C1 0225 0200 0000 0000 0000)

Event 16 of 34: Event ID 16# F9C1:0224


Module STOP due to PG command
External error, Incoming event
(Coding: 16# F9C1 0224 0000 0000 0000 0000)

Event 17 of 34: Event ID 16# F9C1:2409


DP slave was stopped.
External error, Incoming event
(Coding: 16# F9C1 2409 0200 0000 0000 0000)

Event 18 of 34: Event ID 16# F9C1:2415


Slave terminating data transfer.
External error, Incoming event
(Coding: 16# F9C1 2415 0200 0000 0000 0000)

Event 19 of 34: Event ID 16# F9C1:2416


Slave is in data transfer.
External error, Incoming event
(Coding: 16# F9C1 2416 0200 0000 0000 0000)

Event 20 of 34: Event ID 16# F9C1:2414


Slave is ready for data transfer.
The parameter assignment master has the PROFIBUS address: 2.
External error, Incoming event
(Coding: 16# F9C1 2414 0200 0000 0200 0000)

Event 21 of 34: Event ID 16# F9C1:2415


Slave terminating data transfer.
External error, Incoming event
(Coding: 16# F9C1 2415 0200 0000 0000 0000)

Event 22 of 34: Event ID 16# F9C1:2416


Slave is in data transfer.
External error, Incoming event
(Coding: 16# F9C1 2416 0200 0000 0000 0000)

Event 23 of 34: Event ID 16# F9C1:2414


Slave is ready for data transfer.
The parameter assignment master has the PROFIBUS address: 2.
External error, Incoming event
(Coding: 16# F9C1 2414 0200 0000 0200 0000)

Event 24 of 34: Event ID 16# F9C1:2413


Actual configuration has changed.
The new configuration consists of: 48 inputs 8 outputs
External error, Incoming event
(Coding: 16# F9C1 2413 0200 0000 0000 3008)

Event 25 of 34: Event ID 16# F9C1:2413


Actual configuration has changed.
The new configuration consists of: 48 inputs 0 outputs
External error, Incoming event
(Coding: 16# F9C1 2413 0200 0000 0000 3000)

Event 26 of 34: Event ID 16# F9C1:0220


I/O enable by S7 CPU
External error, Incoming event
(Coding: 16# F9C1 0220 0200 0000 0000 0000)

Event 27 of 34: Event ID 16# F9C1:2412


Invalid configuration frame
Master configuration (number of inputs: 48, number of outputs: 8)
Slave configuration (number of inputs: 0, number of outputs: 0).
External error, Incoming event
(Coding: 16# F9C1 2412 0200 0000 3008 0000)

Event 28 of 34: Event ID 16# F9C1:2413


Actual configuration has changed.
The new configuration consists of: 0 inputs 0 outputs
External error, Incoming event
(Coding: 16# F9C1 2413 0200 0000 0000 0000)

Event 29 of 34: Event ID 16# F9C1:0215


Downloading the module database causes module restart
External error, Incoming event
(Coding: 16# F9C1 0215 0000 0000 0000 0000)

Event 30 of 34: Event ID 16# F9C1:0223


Module STOP due to parameter assignment.
External error, Incoming event
(Coding: 16# F9C1 0223 0000 0000 0000 0800)

Event 31 of 34: Event ID 16# F9C1:0225


Module is passive bus node
Restricted functions:
No SEND/RECEIVE mode, no PG mode on SIMATIC NET PROFIBUS
External error, Incoming event
(Coding: 16# F9C1 0225 0200 0000 0000 0000)

Event 32 of 34: Event ID 16# F9C1:0203


Module database invalid.
Internal cause: 10
External error, Incoming event
(Coding: 16# F9C1 0203 0200 0000 1000 0000)

Event 33 of 34: Event ID 16# F9C1:021F


Adopting new MPI parameters
External error, Incoming event
(Coding: 16# F9C1 021F 0200 0000 0000 0000)

Event 34 of 34: Event ID 16# F9C1:0203


Module database invalid.
Internal cause: 14
External error, Incoming event
(Coding: 16# F9C1 0203 0200 0000 1400 0000)