This document contains a diagnostic buffer for module CP 342-5. It lists 34 events recorded by the module relating to configuration changes, data transfers, enable/disable of I/O, module restarts, and issues with the module database. The module hardware version is 2, firmware version is V 6.0.62 and firmware expansion version is V 1.0.9. It is located in rack 0, slot 8.
This document contains a diagnostic buffer for module CP 342-5. It lists 34 events recorded by the module relating to configuration changes, data transfers, enable/disable of I/O, module restarts, and issues with the module database. The module hardware version is 2, firmware version is V 6.0.62 and firmware expansion version is V 1.0.9. It is located in rack 0, slot 8.
This document contains a diagnostic buffer for module CP 342-5. It lists 34 events recorded by the module relating to configuration changes, data transfers, enable/disable of I/O, module restarts, and issues with the module database. The module hardware version is 2, firmware version is V 6.0.62 and firmware expansion version is V 1.0.9. It is located in rack 0, slot 8.
Slave is in data transfer. External error, Incoming event (Coding: 16# F9C1 2416 0200 0000 0000 0000)
Event 2 of 34: Event ID 16# F9C1:2414
Slave is ready for data transfer. The parameter assignment master has the PROFIBUS address: 2. External error, Incoming event (Coding: 16# F9C1 2414 0200 0000 0200 0000)
Event 3 of 34: Event ID 16# F9C1:2413
Actual configuration has changed. The new configuration consists of: 48 inputs 8 outputs External error, Incoming event (Coding: 16# F9C1 2413 0200 0000 0000 3008)
Event 4 of 34: Event ID 16# F9C1:2413
Actual configuration has changed. The new configuration consists of: 48 inputs 0 outputs External error, Incoming event (Coding: 16# F9C1 2413 0200 0000 0000 3000)
Event 5 of 34: Event ID 16# F9C1:0220
I/O enable by S7 CPU External error, Incoming event (Coding: 16# F9C1 0220 0200 0000 0000 0000)
Event 6 of 34: Event ID 16# F9C1:2412
Invalid configuration frame Master configuration (number of inputs: 48, number of outputs: 8) Slave configuration (number of inputs: 0, number of outputs: 0). External error, Incoming event (Coding: 16# F9C1 2412 0200 0000 3008 0000)
Event 7 of 34: Event ID 16# F9C1:2413
Actual configuration has changed. The new configuration consists of: 0 inputs 0 outputs External error, Incoming event (Coding: 16# F9C1 2413 0200 0000 0000 0000)
I/O disable by S7 CPU External error, Incoming event (Coding: 16# F9C1 0221 0200 0000 0000 0000)
Event 10 of 34: Event ID 16# F9C1:2416
Slave is in data transfer. External error, Incoming event (Coding: 16# F9C1 2416 0200 0000 0000 0000)
Event 11 of 34: Event ID 16# F9C1:2414
Slave is ready for data transfer. The parameter assignment master has the PROFIBUS address: 2. External error, Incoming event (Coding: 16# F9C1 2414 0200 0000 0200 0000)
Event 12 of 34: Event ID 16# F9C1:2413
Actual configuration has changed. The new configuration consists of: 48 inputs 8 outputs External error, Incoming event (Coding: 16# F9C1 2413 0200 0000 0000 3008)
Event 13 of 34: Event ID 16# F9C1:2413
Actual configuration has changed. The new configuration consists of: 0 inputs 0 outputs External error, Incoming event (Coding: 16# F9C1 2413 0200 0000 0000 0000)
Module is passive bus node Restricted functions: No SEND/RECEIVE mode, no PG mode on SIMATIC NET PROFIBUS External error, Incoming event (Coding: 16# F9C1 0225 0200 0000 0000 0000)
Event 16 of 34: Event ID 16# F9C1:0224
Module STOP due to PG command External error, Incoming event (Coding: 16# F9C1 0224 0000 0000 0000 0000)
Slave is in data transfer. External error, Incoming event (Coding: 16# F9C1 2416 0200 0000 0000 0000)
Event 20 of 34: Event ID 16# F9C1:2414
Slave is ready for data transfer. The parameter assignment master has the PROFIBUS address: 2. External error, Incoming event (Coding: 16# F9C1 2414 0200 0000 0200 0000)
Slave is in data transfer. External error, Incoming event (Coding: 16# F9C1 2416 0200 0000 0000 0000)
Event 23 of 34: Event ID 16# F9C1:2414
Slave is ready for data transfer. The parameter assignment master has the PROFIBUS address: 2. External error, Incoming event (Coding: 16# F9C1 2414 0200 0000 0200 0000)
Event 24 of 34: Event ID 16# F9C1:2413
Actual configuration has changed. The new configuration consists of: 48 inputs 8 outputs External error, Incoming event (Coding: 16# F9C1 2413 0200 0000 0000 3008)
Event 25 of 34: Event ID 16# F9C1:2413
Actual configuration has changed. The new configuration consists of: 48 inputs 0 outputs External error, Incoming event (Coding: 16# F9C1 2413 0200 0000 0000 3000)
Event 26 of 34: Event ID 16# F9C1:0220
I/O enable by S7 CPU External error, Incoming event (Coding: 16# F9C1 0220 0200 0000 0000 0000)
Event 27 of 34: Event ID 16# F9C1:2412
Invalid configuration frame Master configuration (number of inputs: 48, number of outputs: 8) Slave configuration (number of inputs: 0, number of outputs: 0). External error, Incoming event (Coding: 16# F9C1 2412 0200 0000 3008 0000)
Event 28 of 34: Event ID 16# F9C1:2413
Actual configuration has changed. The new configuration consists of: 0 inputs 0 outputs External error, Incoming event (Coding: 16# F9C1 2413 0200 0000 0000 0000)
Module STOP due to parameter assignment. External error, Incoming event (Coding: 16# F9C1 0223 0000 0000 0000 0800)
Event 31 of 34: Event ID 16# F9C1:0225
Module is passive bus node Restricted functions: No SEND/RECEIVE mode, no PG mode on SIMATIC NET PROFIBUS External error, Incoming event (Coding: 16# F9C1 0225 0200 0000 0000 0000)