You are on page 1of 4

Model: Not Actual Patient

LS-2000 is designed to minimize damage to connective tissue,


leading to greater fat removal with less blood loss and reduction
in recovery time and discomfort
Skill Enhanced Technology

Less trauma to the body and faster recovery


LipoSaver offers greater tissue selectivity and less connective tissue damage

Membrane Fragility Better skin retraction


& Cell Implosion and body contouring results
Probe emits ultrasound energy
Ultrasound energy gently stimulates
skin to retract better to the new contour
Makes micro bubbles of the treated area, providing fewer skin
irregularities and predictable outcomes
Bubble expand and implode

Selectively emulsify fat cell,


Improved procedures
largely sparing more dence tissues with less fatigue
The process of emulsification allows
Loosened fat cells mix with tumescent more efficient fat extraction with
fluid to be removed more easily less surgeon fatigue and aspiration time

Increase ability on areas requiring more precision


Soft tissue type Fibrous tissue type

Precisely targeting all tissue types from soft


to tough, fibrous tissue types for easier body
sculpting procedures
Efficiently breaking down larger volumes of fat
or small pockets of fat in delicate areas where
fat traditionally has been difficult to treat
(Pig fat tissue) (Human fat tissue)
from Spot Reduction to Body-Wide Transformation

Male Abdomen Gynecomastia Double Chin

Before After Before After Before After

Female Abdomen Back Arm


Dr. KYUNG CHUN ANN(CELLDIA CLINIC) Before and after photos have not been retouched. Individual results may vary.

all tissue types all areas of the body Spot reduction


soft fibrous
diameter sizes longer probe
tissue tissue
1.2D 1.9D 2.9D 3.7D 4.0D 500mm
Face Arm Abdomen
Double Chins Flanks Back 330mm
3 2 1 Chin Lipoma Calves Thighs 317mm
Buttocks
123mm

Number of grooves
Advanced technology
One of the most advanced methods of liposuction Technical Specification
Emulsification Source Ultrasound
Liposaver is innovative device offering affordable solutions
that can satisfy your needs in the practice Handpiece 215mm, 30Φ
Operation Modes N Mode - Continuous output
Comparison with other technology Z Mode - Pulsed output
(Freq. 10Hz / Duty ratio: 66%)
Technology Fat Volume Application
Probes Φ1.9 / Φ2.9 / Φ3.7
Φ1.2 / Φ4.0 (Optional)
LipoSaver LS-2000
Small to Very Large No Limitation
(Ultrasound Assisted) Probe tuning frequency 35kHz - 40kHz

LAL Extremely limited Output acoustic power 0-90 W max ±20%


Small to Medium
(Laser Assisted) application
Input Power AC 100V - 240V / 50 - 60 Hz
WAL Limited application
Medium to Large Dimension (WxHxL) 395 X 172 X 275 mm
(Water Assisted) for small areas
Main Body Weight 4.3 kg
PAL Limited application
Medium to Large
(Power Assisted) for small areas Environmental Operating Specification

SAL Limited application Operating Temperature 10 to 40 °C / 50 to 105 °F


Small to Very Large
(Suction Assisted) in fibrous tissue Atmospheric Pressure 79.051kPa to 101.325kPa

Operating Humidity 15% to 80%


Relative humidity
Non-condensing

LHbiomed Co., Ltd.


www.lhbiomed.com
Tel: +82-33-901-0411
Fax: +82-33-901-0422
E-mail: lhbiomed@lhbiomed.com

#806 Medical Device Complex Center


200 Gieopdosi-ro, Jijang-myeon, Wonju-si
Gangwon-do, S. Korea

LS-2000 R&D Center


F.A.S.T Algorithm
B-1508, H Business Park
Powerful, yet stable Output Energy 25, Beobwon-ro 11-gil, Songpa-gu,
Seoul, S. Korea

You might also like