12.05.

2020
E-C-1111-SHT-01
NOTES:
01.OK
02. OK
03. OK
04. CEMENT USED SHALL BE OPC CEMENT TYPE CONFORMING WITH ASTM C150 TYPE I.
05. REINFORCEMENT BAR SHALL HAVE MINIMUM YIELD STRENGTH EQUAL TO 414 Mpa (60000 PSI) AND
SHALL CONFORM TO :
A) BEAM STIRRUPS - ASTM A615M
B) BEAM LONGITUDINAL BARS - ASTM A615M BY COMPLYING BELOW NOTES C, D & E
C) ACTUAL YIELD STRENGTH BASED ON MILL TESTS DOES NOT EXCEED Fy BY MORE THAN 125 Mpa.
D) RATIO OF THE ACTUAL TENSILE STRENGTH TO THE ACTUAL YIELD STRENGTH IS AT LEAST 1.25.
(Fy ≥ 539 Mpa FOR Fy = 414 Mpa).
E) MINIMUM ELONGATION IN 200 MM SHALL BE AT LEAST 14% FOR BAR SIZES 10-19 (9.525-19.05MM),
AT LEAST 12% FOR BAR SIZES 22-36 (22.225-35.810 MM)
06. CLEAR COVER TO REINFORCEMENT SHALL BE AS FOLLOWS:
A) FLOOR BEAM 40mm
B) FLOOR SLAB 25mm
07. FOR CONCRETE GENERAL NOTES REFER DWG.55-02-1 & 2.
08. CUTTING, BENDING, PLACEMENT, SPLICE AND DETAILING OF REINFORCEMENT SHALL BE IN ACCORDANCE
WITH ACI 318M (LATEST EDITION)
09. AT JUNCTION REBARS SHOULD BE CRANKED ACCORDINGLY TO AVOID THE OVERLAPPING.
10. ALL EXPOSED CONCRETE SURFACES SHALL BE FAIR FACED AND WITHOUT ANY HONEY COMBING AND
SHALL BE PAINTED WITH LIGHT CREAM COLOR GLOSS ENAMEL PAINT.
11. ALL EXPOSED EDGES OF CONCRETE SHALL BE 25x25mm CHAMFERED.