Professional Documents
Culture Documents
Member Name: C1: 1. General Information
Member Name: C1: 1. General Information
1. General Information
(1) Design Code : ACI318M-14
(2) Unit System : N, mm
2. Material
(1) : 21.00MPa
(2) : 275MPa
(3) : 275MPa
350
450
3. Section
(1) Section Size : 450 x 350mm
(2) : 3.800m
(3) : 3.800m
(4) : 0.500
(5) : 0.500
(6) Splicing Limit : 50%
(7) Frame Type : Braced Frame
4. Forces
(1) : 507kN
(2) : 82.03kN·m
(3) : 62.13kN·m
(4) : 21.69kN
(5) : 42.19kN
(6) : 507kN
(7) : 507kN
5. Factors
(1) : 1.000
(2) : 1.000
(3) : 1.000
6. Rebar
(1) Main Bar
ㆍ Layer-1 = = 2,413mm² )
ㆍ Layer-2 :-
ㆍ Layer-3 :-
ㆍ Layer-4 :-
ㆍ : 2,413mm²
(2) Hoop Bar
ㆍ End : d10@50.00
ㆍ Middle : d10@100
(3) Tie Bar
ㆍ Apply Tie Bar to Shear Check : Yes
ㆍ Tie Bar = 227MPa )
7. Option
(1) Special provisions for seismic design is applied.
(2) Frame Type : Special Moment Frame
2650
2225
1800
1785 eb=312.99mm
1375
950
525
(630,128)
(507,103)
100 M (kN·m)
0
-325
-750
0
20
40
60
80
100
120
140
160
180
200
15. Calculate Shear Force by Special Provisions for Seismic Design ( Direction Y ).
(1) Calculate bending strength for design shear force.
ㆍ ø = 1.000
ㆍ = 234kN·m
ㆍ = 234kN·m
ㆍ = 234kN·m
ㆍ = 234kN·m
(2) Calculate design shear force by special provision for seismic design
ㆍ = = 104kN
ㆍ = = 104kN
ㆍ = = 104kN
16. Calculate Shear Force by Special Provisions for Seismic Design ( Direction X ).
(1) Calculate bending strength for design shear force.
ㆍ ø = 1.000
ㆍ = 198kN·m
ㆍ = 198kN·m
ㆍ = 198kN·m
ㆍ = 198kN·m
(2) Calculate design shear force by special provision for seismic design
ㆍ = = 123kN
ㆍ = = 123kN
ㆍ = = 123kN
17. Check Shear Capacity
(1) Calculate maximum space
ㆍ ø = 0.750
ㆍ = 215mm
ㆍ = = 87.50mm
ㆍ = = 145mm
ㆍ = = 87.50mm
(2) Calculate Shear Strength ( Direction X )
ㆍ s = = 87.50mm → O.K
ㆍ = = 103kN
ㆍ = = 375kN
ㆍ = = 478kN
ㆍ = 0.258 → O.K
(3) Calculate Shear Strength ( Direction Y )
ㆍ s = = 87.50mm → O.K
ㆍ = = 100kN
ㆍ = = 284kN
ㆍ = = 384kN
ㆍ = 0.272 → O.K