OLC-D1, OLCKI Level monitoring The OLC series consists of a screw-in prism unit, and an optical level detection device. The prisms, installed in the compressor or the vessel and is not included with the OLC. The level detection device ‘can be replaced without opening to the compressor or the vessel. Detection of the level is via infrared _light.There isa built-in monitoring system for correct. Installation. Oil level monitoring in compressors ‘The OLC series are used for contactless oil level ‘monitoring in compressors in order to safeguard sufficient lubrication of the internal mechanics. As the refrigerant can be absorbed by oll, fluctua- tion of the oil level in the compressor is common in refrigeration systems and thereby oil levels need to be monitored. OLC-K1 is for piston compressor use and opens the relay after 90 seconds whereas the OLC-D1 is for screw compressors and opens the relay after 5 seconds delay. Level monitoring in vessels The OLC-D1 is meant for level monitoring in vessels. and does not have the operation recognition input, D1. ‘The OLC-D1 releases the relay if the level is too low and activates the relay ifthe levels valid. There isa 5 seconds time delay between switching the relay. BLodam BY BITZER GROUP Oil Level Control | ade Optical Level Monitoring Device Red LED status light_ ‘At startup, the OLC will flash shortly with the LED. After approx.3 seconds the relay will be activated. For OLC-D1 the level monitoring starts immediately, forthe OLC-K1 monitoring starts when the D1 signal is applied and after the 90 seconds delay time the levels evaluated. If the oil level is too low or there isa failure, the relay will be opened and the LED will signal the failure. LED off: Oil level good, no failures LED On: Oil level low LED lashing: OLCnot correctly mounted, or Supply voltage too low, or Internal failure Lock-out state The OLC-D1 and OLC-K1 will lock-out in case of failure. The OLC-K1 will further lock-out in case of low oil level. Reset of lock-out state Interrupt power supply for 5 seconds. Lodamelectronicsa/s | Te. 4573423737 | ladam@ledamcom Keeve| 77 | Faxs48 72423730 wnwtlodamcam* {400 Sonderborg Denmark thout no tte chang contents Schematic Wiring Diagram Supply OLCDI-T1SVEAC TIS VsI0N%, S0/6OHE (O1C-D1-230 AC 230¥s10% 50/60Hz OLCKI-115V: AC 115 V210%,SO/6OHz 82 ‘OLC-K1-230V; AC230 Vs 10%, 50/60Hr ‘OLC-D1-24V: AC 24Vacldce 10%, SO/60HZ iar ——————-Averions v8 cy Relay 2OVAC, 2.5A,C300- resistive load = S24vAC/DC, >20mA Permitted ambient Operation: -30°C-60°C 6 temperature Storage: -30°C—+80°C 6 Maxtemperatueof OLC-K1=+100°C FZ media 1c 01: +120" rises Relative humidity Max. 95% r ‘Wire ength (0LC-01:950/ 2050 mm +50 mm (OLC-K1: 1050 mm 250 mm fe Fuse required 4A fast blow Ka Enclosure class Housing IPS4; cable outlet pointing kore ‘downwards Mt Mounting ofthe Screw mounted, M24 detection circuit _-Ma.tghtening torque: 10Nm by hand a ae IRS ULflemumber £34818, — ee «AT feeoate aie a Brown Phase Blue NeNeutral rey C:Common signal orange NO; Normal open Pink INC; Normal closed Violet (only OLC-K1) D1; Compressor running 5152153 v s BLodam BY BITZER GROUP Lodam electronisa/s Kaerve|77 {6400 Sonderborg Denmark Control unit Contra unit of apactty regulation (option) Main fuse Compressor fuse Control circuit fuse High pressure cut-out Low pressure cutout Fuse of crank case heater “Thermal overload motor PW / PZ ‘Signal ight"Compressor over temperature fault” Signa ight “Oitsuply fault” ‘Motor contactors PW! /PW2 Time relays"part wincing’/ pause time Compressor Main switch PTCsensorsin motor windings PTC sensor in cinder head/dicharge gas tempera ‘ute sensor (option) Crankcase heater (option) Control switch Solenoid valve“star unloading” option) Solenoid valve“iquid ine” Solenoid valve “capacity regulation (option) ‘Tel.445 73423737 Fax +45 73423730, lodamatodam.com | vewolodam.com

You might also like