You are on page 1of 8

70439 Abbott Folder 5/9/07 11:21 AM Page 1

Designed for seamless


Product Specifications integration
Delivers accurate
results fast

™*

™*

ARCHITECT c16000 ™*
ARCHITECT i2000SR ®

clinical chemistry immunoassay

Photometric
Detection Methods Potentiometric
CHEMIFLEX®
Turbidimetric

Maximum Throughput 1,800 tests/hour 200 tests/hour

Sample Types Serum, plasma, urine, CSF Serum, plasma, urine

Height: 72-102 mm Height: 72-102 mm


Sample Tubes Diameter: 8.25-16.1 mm Diameter: 8.25-16.1 mm

Pediatric Sample Cup Yes (50 µL dead volume) Yes (50 µL dead volume)

Sample Capacity Total of 365 on the integrated ARCHITECT ci16200* system

2-35 µL 10-150 µL
Sample Volume Average: 5 µL Average: 50 µL

Automatic Dilution Yes Yes

Sample-to-sample Carryover <0.1 parts per million <0.1 parts per million

65 refrigerated positions plus patented


Reagent Capacity 25 refrigerated positions
ICT (Na+, K+ and CI-)

Reagent Type >95% liquid ready-to-use Liquid ready-to-use

5-65 days
Reagent Onboard Stability 30 days
Average: 30 days
8 hours-60 days
Calibration Frequency Average: 25 days

Sample Clot and Bubble Detection Yes Yes

Reagent Pressure Monitoring In development Yes

Integration
Sample Interference Measurement Hemolysis, icterus and lipemia measured on the c16000*

System Control Center A single computer with color touch screen monitor, keyboard and mouse

Onboard Maintenance Records Yes Yes

Online Error Code Help Yes Yes

Remote Diagnostics AbbottLink® AbbottLink®

Dimensions (H x W x D)
48'' x 79'' x 49''
121.9 x 200.6 x 124.5 cm
48'' x 61'' x 49''
121.9 x 154.9 x 124.5 cm
that frees your lab
1,545 lbs 1,081 lbs
Weight 701 kg 490 kg

Electrical Requirements AC 180-264V, 47-63 Hz AC 180-264V, 47-63 Hz

Maximum Water Requirements NCCLS Type II, 54 liters per hour NCCLS Type II to dilute buffer concentrate

Maximum Heat Output 3,300 watts 2,500 watts

*Now available ex-U.S.


ARCHITECT, i2000SR, CHEMIFLEX and AbbottLink are registered trademarks of
Abbott Laboratories.
ci16200*, c16000*, SmartWash and FlexRate are trademarks of Abbott Laboratories.
www.abbottdiagnostics.com
1-800-323-9100
*Now available ex-U.S.

© 2007 Abbott Laboratories 98-1450/R1-2.5 Apr 2007 Printed in USA

*Now available ex-U.S.

in the clinical results


The benefits: certainty and confidence

on i2000SR , in development for c16000™*)®

Reagent pressure monitoring (available


consistent user experience sample volume to reduce analytical error
instruments and a simple, detection of clots, bubbles, and insufficient
and clinical chemistry Pressure differential technology enables
ARCHITECT immunoassay
patient results across all and easy to maintain (45,000 determinations)
The benefits: equivalent module for electrolytes is small, long-lasting
Integrated Chip Technology (ICT)
— Universal sample carrier
fewer reruns
— Identical ARCHITECT software enzyme assays for better first-time results,
FlexRate™ extends the linear ranges of
reagents and assay protocols
— Identical FlexRate chemistry technology, extended linear ranges
technology, reagents and assay protocols delivers exceptional detection and
— Identical CHEMIFLEX immunoassay flexible immunoassay protocols
CHEMIFLEX® technology with
of analyzers:
design philosophy of the ARCHITECT family
The ARCHITECT ci16200™* exemplifies the
Assay Dynamics
System and
True Family Commonality Enhanced
70439 Abbott Folder 5/9/07 11:21 AM Page 2

Today’s
integrated lab
without yesterday’s
frustrations
Designed for seamless integration
• Immunoassay and clinical chemistry
testing on a single instrument
• Unique combination of four
detection methods
• Created specifically for the complex
workload of the high-volume lab

Delivers accurate results fast


• Fastest turnaround time and
total throughput in a study of
comparable analyzers†
• Immediate and consistent
STAT results regardless of
routine workload

Analyzers from Roche, Bayer and Beckman


Armbruster et al. Test Turnaround Time (TAT) and Throughput


Comparison Study of Six Integrated Clinical
Chemistry/Immunoassay Systems. [Abstract]
Clinical Chemistry Supplement, June 2007 (In press).
70439 Abbott 4Pager 5/9/07 11:27 AM Page 2

ARCHITECT ® ci16200™*
ARCHITECT : rise above ®
Immunochemistry System

everyday
challenges Easier day-to-day management
• Chemistry and immunoassay testing
with a single user interface
Integration Without Built to work together • Reduced operator training
Compromise Rather than simply combining older
• Extended linear ranges result in fewer
technologies, the ARCHITECT line of repeats and reruns
High-speed integration of clinical chemistry analyzers was developed—from
and immunoassay
day one—as an integrated Confidence in testing results
Maximum throughput of up to 2,000 tests immunochemistry platform. • Leading edge assay and system
per hour technology
All ARCHITECT instruments are • Less than 0.1 ppm (clinically
The ARCHITECT Robotic Sample Handler standardized—equivalent patient results, insignificant) sample-to-sample
(RSH) allows the lab to prioritize tests carryover
identical software user interface,
SmartWash™ technology effectively controls universal sample carrier and a • Sample pressure monitoring
sample-to-sample carryover (<0.1 ppm tube robotic sample handler (RSH). with clot and bubble detection
to tube) • Reagent pressure monitoring
(available on i2000SR , in development
®

Large load-up capacity 365 samples for c16000™*).


(including 35 priority positions) and up to 90
refrigerated reagent positions plus patented
ARCHITECT
universal sample carrier
ICT (Na+, K+ and Cl- )

The benefits: effectively handle complex


workloads on a single platform

*Now available ex-U.S.


70439 Abbott 4Pager 5/9/07 11:27 AM Page 1

From the ground up


Chemistry and immunoassay in a single • Designed for seamless integration
• Exceptional workload management for timely

streamlined instrument
and accurate patient results
• Automated STAT management for less workload
disruption

4
3 5

10
7

8 7
12

2 11
1 13
9 14
6
9

15

16
1 Sample carousel 5 Integrated Chip Technology (ICT) 9 Local user interfaces 13 STAT sample pipettor
(30 positions)
6 Glass cuvettes (330) 10 Reagent pipettors (2) 14 Reaction vessel hopper
2 Sample probe
7 Refrigerated reagent carousels 11 Sample pipettor 15 Robotic Sample Handler (RSH)
3 Piezoelectric mixers (4) (65 positions each) (335 samples)
12 Refrigerated reagent carousel
4 Cuvette washer 8 Reagent probes (4) (25 positions) 16 RSH indicator lights
70439 Abbott 4Pager 5/9/07 11:27 AM Page 1

From the ground up


Chemistry and immunoassay in a single • Designed for seamless integration
• Exceptional workload management for timely

streamlined instrument
and accurate patient results
• Automated STAT management for less workload
disruption

4
3 5

10
7

8 7
12

2 11
1 13
9 14
6
9

15

16
1 Sample carousel 5 Integrated Chip Technology (ICT) 9 Local user interfaces 13 STAT sample pipettor
(30 positions)
6 Glass cuvettes (330) 10 Reagent pipettors (2) 14 Reaction vessel hopper
2 Sample probe
7 Refrigerated reagent carousels 11 Sample pipettor 15 Robotic Sample Handler (RSH)
3 Piezoelectric mixers (4) (65 positions each) (335 samples)
12 Refrigerated reagent carousel
4 Cuvette washer 8 Reagent probes (4) (25 positions) 16 RSH indicator lights
70439 Abbott 4Pager 5/9/07 11:27 AM Page 2

ARCHITECT ® ci16200™*
ARCHITECT : rise above ®
Immunochemistry System

everyday
challenges Easier day-to-day management
• Chemistry and immunoassay testing
with a single user interface
Integration Without Built to work together • Reduced operator training
Compromise Rather than simply combining older
• Extended linear ranges result in fewer
technologies, the ARCHITECT line of repeats and reruns
High-speed integration of clinical chemistry analyzers was developed—from
and immunoassay
day one—as an integrated Confidence in testing results
Maximum throughput of up to 2,000 tests immunochemistry platform. • Leading edge assay and system
per hour technology
All ARCHITECT instruments are • Less than 0.1 ppm (clinically
The ARCHITECT Robotic Sample Handler standardized—equivalent patient results, insignificant) sample-to-sample
(RSH) allows the lab to prioritize tests carryover
identical software user interface,
SmartWash™ technology effectively controls universal sample carrier and a • Sample pressure monitoring
sample-to-sample carryover (<0.1 ppm tube robotic sample handler (RSH). with clot and bubble detection
to tube) • Reagent pressure monitoring
(available on i2000SR , in development
®

Large load-up capacity 365 samples for c16000™*).


(including 35 priority positions) and up to 90
refrigerated reagent positions plus patented
ARCHITECT
universal sample carrier
ICT (Na+, K+ and Cl- )

The benefits: effectively handle complex


workloads on a single platform

*Now available ex-U.S.


70439 Abbott Folder 5/9/07 11:21 AM Page 1
Designed for seamless
Product Specifications integration
Delivers accurate
results fast
™*
™*
®
ARCHITECT c16000 ™ * ARCHITECT i2000SR
clinical chemistry immunoassay
Photometric
Detection Methods Potentiometric
CHEMIFLEX®
Turbidimetric
Maximum Throughput 1,800 tests/hour 200 tests/hour
Sample Types Serum, plasma, urine, CSF Serum, plasma, urine
Height: 72-102 mm Height: 72-102 mm
Sample Tubes Diameter: 8.25-16.1 mm Diameter: 8.25-16.1 mm
Pediatric Sample Cup Yes (50 µL dead volume) Yes (50 µL dead volume)
Sample Capacity Total of 365 on the integrated ARCHITECT ci16200* system
2-35 µL 10-150 µL
Sample Volume Average: 5 µL Average: 50 µL
Automatic Dilution Yes Yes
Sample-to-sample Carryover <0.1 parts per million <0.1 parts per million
65 refrigerated positions plus patented
Reagent Capacity 25 refrigerated positions
ICT (Na+, K+ and CI-)
Reagent Type >95% liquid ready-to-use Liquid ready-to-use
5-65 days
Reagent Onboard Stability 30 days
Average: 30 days
8 hours-60 days
Calibration Frequency Average: 25 days
Sample Clot and Bubble Detection Yes Yes
Reagent Pressure Monitoring In development Yes
Sample Interference Measurement Hemolysis, icterus and lipemia measured on the c16000*
System Control Center A single computer with color touch screen monitor, keyboard and mouse
Onboard Maintenance Records Yes Yes
Online Error Code Help Yes Yes
Remote Diagnostics
Dimensions (H x W x D)

AbbottLink®
48'' x 79'' x 49''
121.9 x 200.6 x 124.5 cm

AbbottLink®
48'' x 61'' x 49''
121.9 x 154.9 x 124.5 cm

Integration
that frees your lab
1,545 lbs 1,081 lbs
Weight 701 kg 490 kg
Electrical Requirements AC 180-264V, 47-63 Hz AC 180-264V, 47-63 Hz
Maximum Water Requirements NCCLS Type II, 54 liters per hour NCCLS Type II to dilute buffer concentrate
Maximum Heat Output 3,300 watts 2,500 watts
*Now available ex-U.S.
ARCHITECT, i2000SR, CHEMIFLEX and AbbottLink are registered trademarks of
Abbott Laboratories.
ci16200*, c16000*, SmartWash and FlexRate are trademarks of Abbott Laboratories.
www.abbottdiagnostics.com
1-800-323-9100
*Now available ex-U.S.
© 2007 Abbott Laboratories 98-1450/R1-2.5 Apr 2007 Printed in USA
*Now available ex-U.S.
in the clinical results
The benefits: certainty and confidence
®
on i2000SR , in development for c16000™*)
Reagent pressure monitoring (available
consistent user experience sample volume to reduce analytical error
instruments and a simple, detection of clots, bubbles, and insufficient
and clinical chemistry Pressure differential technology enables
ARCHITECT immunoassay
patient results across all and easy to maintain (45,000 determinations)
The benefits: equivalent module for electrolytes is small, long-lasting
Integrated Chip Technology (ICT)
— Universal sample carrier
fewer reruns
— Identical ARCHITECT software enzyme assays for better first-time results,
FlexRate™ extends the linear ranges of
reagents and assay protocols
— Identical FlexRate chemistry technology, extended linear ranges
technology, reagents and assay protocols delivers exceptional detection and
— Identical CHEMIFLEX immunoassay flexible immunoassay protocols
CHEMIFLEX® technology with
of analyzers:
design philosophy of the ARCHITECT family
The ARCHITECT ci16200™* exemplifies the
Assay Dynamics
System and
True Family Commonality Enhanced
70439 Abbott Folder 5/9/07 11:21 AM Page 1

Designed for seamless


Product Specifications integration
Delivers accurate
results fast

™*

™*

ARCHITECT c16000 ™*
ARCHITECT i2000SR ®

clinical chemistry immunoassay

Photometric
Detection Methods Potentiometric
CHEMIFLEX®
Turbidimetric

Maximum Throughput 1,800 tests/hour 200 tests/hour

Sample Types Serum, plasma, urine, CSF Serum, plasma, urine

Height: 72-102 mm Height: 72-102 mm


Sample Tubes Diameter: 8.25-16.1 mm Diameter: 8.25-16.1 mm

Pediatric Sample Cup Yes (50 µL dead volume) Yes (50 µL dead volume)

Sample Capacity Total of 365 on the integrated ARCHITECT ci16200* system

2-35 µL 10-150 µL
Sample Volume Average: 5 µL Average: 50 µL

Automatic Dilution Yes Yes

Sample-to-sample Carryover <0.1 parts per million <0.1 parts per million

65 refrigerated positions plus patented


Reagent Capacity 25 refrigerated positions
ICT (Na+, K+ and CI-)

Reagent Type >95% liquid ready-to-use Liquid ready-to-use

5-65 days
Reagent Onboard Stability 30 days
Average: 30 days
8 hours-60 days
Calibration Frequency Average: 25 days

Sample Clot and Bubble Detection Yes Yes

Reagent Pressure Monitoring In development Yes

Integration
Sample Interference Measurement Hemolysis, icterus and lipemia measured on the c16000*

System Control Center A single computer with color touch screen monitor, keyboard and mouse

Onboard Maintenance Records Yes Yes

Online Error Code Help Yes Yes

Remote Diagnostics AbbottLink® AbbottLink®

Dimensions (H x W x D)
48'' x 79'' x 49''
121.9 x 200.6 x 124.5 cm
48'' x 61'' x 49''
121.9 x 154.9 x 124.5 cm
that frees your lab
1,545 lbs 1,081 lbs
Weight 701 kg 490 kg

Electrical Requirements AC 180-264V, 47-63 Hz AC 180-264V, 47-63 Hz

Maximum Water Requirements NCCLS Type II, 54 liters per hour NCCLS Type II to dilute buffer concentrate

Maximum Heat Output 3,300 watts 2,500 watts

*Now available ex-U.S.


ARCHITECT, i2000SR, CHEMIFLEX and AbbottLink are registered trademarks of
Abbott Laboratories.
ci16200*, c16000*, SmartWash and FlexRate are trademarks of Abbott Laboratories.
www.abbottdiagnostics.com
1-800-323-9100
*Now available ex-U.S.

© 2007 Abbott Laboratories 98-1450/R1-2.5 Apr 2007 Printed in USA

*Now available ex-U.S.

in the clinical results


The benefits: certainty and confidence

on i2000SR , in development for c16000™*)®

Reagent pressure monitoring (available


consistent user experience sample volume to reduce analytical error
instruments and a simple, detection of clots, bubbles, and insufficient
and clinical chemistry Pressure differential technology enables
ARCHITECT immunoassay
patient results across all and easy to maintain (45,000 determinations)
The benefits: equivalent module for electrolytes is small, long-lasting
Integrated Chip Technology (ICT)
— Universal sample carrier
fewer reruns
— Identical ARCHITECT software enzyme assays for better first-time results,
FlexRate™ extends the linear ranges of
reagents and assay protocols
— Identical FlexRate chemistry technology, extended linear ranges
technology, reagents and assay protocols delivers exceptional detection and
— Identical CHEMIFLEX immunoassay flexible immunoassay protocols
CHEMIFLEX® technology with
of analyzers:
design philosophy of the ARCHITECT family
The ARCHITECT ci16200™* exemplifies the
Assay Dynamics
System and
True Family Commonality Enhanced

You might also like