125 Maret eet - Tet (209)786-5200 ga inven C7 0958 » AccuStandard; Inc. worn toe Catalog No: APP-8-102 Date Certified: Jul, 2020, Description: Endrin Expiration: Aug 9, 2022 Lot 219051657-01 Sample Size: 1 mL Solvent: Methanol Components: 1 Hazards: Rofor fo SDS for complete safety information Storage Condition: Refig (0-5 °C) ® Cerio Referance Matra Signal Word: Danger anan S ‘Component case Party % Prepared. Certified Analyte Concentration Concentration" (cows) (ua) (ui) Enden 72208 sr9 026" 1008 * Woight componsated to 100% pry A proc wha su, -28, ec, oF, 02, oni ot rurber has haits expiration dae extended ands etal othe same ft number witht Be sus, = At weight te vaceabl tough NIST, Tos No, 684728987117 * Conta nays Concentration = Party x Prepared Cancantratn ‘The Uncertainty associated wit th cried concentration rope on this orcas 2.4. This values the combinod axpandeé uncon and eprsonts an stats standara deviaton equal tho postive ste rot 9h aa! van one uneoriainy of components. A nral tibutons assumes ana a coverage factor of K=2 i choson using approxmatoly 395% coridneo Iva Labels and creates follow U.S, Conventions in reporting rurerical values: A comm) ued osapaate unis fone thousand ops. A por (is ued as 2 ecmal place mare ‘The infomation on tis ateata my not be reproduced whos the expres pemission af the manufacturer. See reverse side foradetoninormaton -Hazars infomation: Plas reer to the SS fr rtormatin regarding the hazards associates wh using this ator ‘Ths product was prepared according a inhouse procedures and is quarareod to be homogeneous conte Page tof 1 For use in routine laboratory analysis. AccuStandard is accredited to ISO 17034, ISOMEC 17025 and certified to ISO 9001:2015 ronan Quality Standards: ISO 17034:2016 ~ General Requirements for the Competence of Reference Material Producers ISO/IEC 17025:2017 — General Requirements for the Competence of Testing And Calibration Laboratories, ISO 9001:2015 — Quality Management System — Requirements Eagle Registrations Intended Use: The product covered by this certificate is designed for calibration or for use in quality control procedures for the specified chemical compounds listed on the reverse side. This product can be used for quantification and/or Identification. This product can also be used as a reference material to validate analytical procedures, subject to the conditions under Section 7 Manufacturing: All balances are calibrated daily using an in-house procedure with weights that are compared annually to master weights and traceable to NIST. The balances are also calibrated annually by an ISO/IEC 17025 accredited calibration laboratory. Please refer to the NIST test number listed on the front of this certicate. Class A glassware is used in the manufacture and quality control of all standards. Good Laboratory Practices have been used throughout the preparation ofthis Standard. Homogeneity: This product is sufficiently homogeneous and any sample size would be within the uncertainty budget. Stability: The manufacturer guarantees the stability of this solution through the expiration date stated on the label, when handled and stored according to the conditions stated on the label Uncertainty: The uncertainty values as stated on the face of this certiicate have been determined using the EURACHEMICITAC Guide. We report a combined expanded uncertainty equal to the positive square root of the total variance of the uncertainty of the components using the following formula: 1, = (AVI ara GATT RO formula represents uncertainty components from the mass, volume, short-term Stability, long-term stability and homogeneity factors associated with the production of this product. The expanded uncertainty, assumes a normal distribution and a coverage factor of k=2 is chosen using approximately a 95% confidence level his Legal Notice and Limit of Liability: This product is for routine laboratory analysis and research purposes only, The company's liability will be limited to replacement of product or refund of purchase price. Notice of claims must be made within thirty (30) days from date of delivery.

You might also like