Critical Point
221 bar-a,
371 deg-C 6 f h
6 8
Temp
e g
d 4
5
7
b 3 c
2
i 9
a 1
Subcritical Cycle
1-2-3-4-5-6-7-8-9-1
Entropy
STEAM AND WATER CIRUIT OF THE
SUPER CRITICAL BOILERS
5710C To HP
Turbine To IP
Turbine 5690C
Mixer Header
5340C
4230C 5260C
4620C
Separator FRH
FSH 4730C
Platen
Heater
From CRH Line LTSH
3260C
4430C
LTRH
3240C
NRV
From FRS Line 2830C
3 ECONOMIZER ASSEMBLIES
CAPACITY
PRESS.
CONDITION
MAIN STEAM
REHEATER
MAIN STEAM
REHEATER
Supercritical Once-Thru Boiler
1,672
1,325
255
53.6
Ton/Hr
Ton/Hr
Kg/cm2g
Kg/cm2g
SUPERCRITICAL
Su pe r cr itical CCOAL FIRED
oal Fir e d STEAM GENERATOR
Ste am Ge nerato r
5 ECONOMIZER HANGER TUBE OUTLET HEADER 36 SILENCERS (PSV, ERV, START UP VENT)
TEMP. MAIN STEAM 569 ºc
6 FURNACE LOWER RING HEADERS 37 F.D. FAN SUCTION W/SILENCERS CONDITION REHEATER 596 ºC
7 FURNACE SPIRAL W/W TUBES 38 FORCED DRAFT FANS FUEL Hi-Vol. “c” , Bit. Coal
8 FURNACE VERTICAL W/W TUBES 39 SECONDARY AIR DUCT TO GAS AIR PREHEATERS FIRING SYSTEM Low Nox Tangential Burners
13 FLASH TANK 44 SCANNER & COOLING AIR FANS LEGEND & ABBREVIATIONS
To HP Turbine 14 CONDENSATE RECEIVING TANK 45 PRIMARY AIR FANS
ACCESS DOOR
TO LP Turbine (HRH) 15 CONDENSATE DRAIN TRANSFER PUMPS 46 HOT PRIMARY AIR DUCT TO MILLS
ACCESS DOOR IN ROOF EMCLOSURE
16 BOILER WATER RECIRCULATING PUMP 47 COLD PRIMARY AIR DUCT TO MILLS
OBSERVATION DOORS
17 BACKPASS LOWER SIDE HEADERS 48 MIXED HOT AIR DUCT TO MILLS
From HP Turbine 18 BACKPASS SIDE WALL TUBES 49 COAL TRIPPER CONVEYOR ROOM
WALL BLOWER
(CRH)
RETRACTABLE SOOTBLOWER-DOUBLE SIDE
19 BACKPASS UPPER SIDE WALL INLET HEADERS 50 COAL SILOS
20 BACKPASS LOWER REAR HEADER 51 COAL FEEDERS HALF TRACT SOOTBLOWER-DOUBLE SIDE
29 REHEATER INLET PIPES (CRH) 60 STEAM COIL AIR HEATER DRAIN TANK
Feed Water Flow Control -Water to Fuel Ratio Three Element Control
-OHD(22-35 OC) -Feed Water Flow
-MS Flow
-Drum Level
17
Steam Water Cycle
Chemistry Controls
S. Parameter Sub Critical Super Critical
No.
Type of Boiler LP and HP dosing. Or No HP dosing
1 water All Volatile Treatment Combined water treatment (CWT).
treatment (Hydrazine + Ammonia)
Silica < 20 ppb in feed water and steam, Standard value <15 ppb in the cycle
2
< 250 ppb in boiler drum Expected value <10 ppb in the cycle
pH 9.0 - 9.5 for feed, steam & 9.0 – 9.6 for AVT(All volatile treatment)
3 condensate, 8.0 – 9.0 for CWT(Combine water
9.0 – 10.0 for Boiler drum treatment)
Dissolved < 7 ppb for feed. < 7 ppb for feed in case of AVT
4
Oxygen (DO) 30 – 150 ppb for feed in case of CWT
Cation (H+) <0.20 µS/cm in the feed & steam Standard value <0.15 µS /cm in the cycle
5 Conductivity cycle Expected value- <0.10 µS /cm in the cycle
Silica and TDS By maintaining feed water quality Blow down possible till separators are
7 control and functioning (upto 30% load).
By operating CBD
Advantages of SC Technology
I ) Higher cycle efficiency means
Primarily
– less fuel consumption
– Per MW infrastructure investments is less
– less emission
– less auxiliary power consumption
– less water consumption
II ) Operational flexibility
– Better temp. control and load change flexibility
– More suitable for widely variable pressure operation
Sub. vs. Supercritical Cycle
Impact on Emissions
Subcritical Supercritical
Plant Efficiency, %* 34 - 37 37 - 41
* HHV Basis
ULTRA SUPER CRITICAL TECHNOLOGY
&
ADVANCED ULTRA SUPER CRITICAL
TECHNOLOGY
The Basic Heat Cycle
Sub-critical units: Main steam pressure < 221. 1 bar
Super-critical units: Main steam pressure > 221. 1 bar
Ultra-supercritical units:
Higher steam pressure and temperature than supercritical
units
Japan: Main steam pressure >242 Bar, or Steam
temperature >593 ℃
Demark: Main steam pressure >275 Bar
China: Main steam pressure >270 Bar
USA (EPRI) : Main steam temperature>593 ℃
STEAM PARAMETERS