You are on page 1of 40

BiometricsLtd Data Acquisition Movement Analysis EMG Associated Sensors Experience More Experience More

Contents Biometrics Ltd is a world leader in the design, manufacture and distribution of technologically advanced sensors, instruments and software for the demanding nee ds in biomedical and engineering research, and educational settings. Markets include m edical, ergonomic, biomechanics, sport science, pharmaceutical and veterinary science. BiometricsLtd Sensors including electrogoniometers for precise joint range of motion measurements Advanced Surface EMG (electromyography) Portable, Wireless and Laboratory data acquisition systems Real time display and analysis software Global customers include: thousands of leading corporations, hospitals, research organizations and universities, North American, European and Asian car manufacturers, aerospace, NASA: where Biometrics technology is used exclusively for movement studies in the Human Performance Laboratory of the International Space Station. Data Acquisition Products Biometrics Ltd range of Data Acquisition Systems collect both analogue and digital data from a wide range of sensors and are available in laboratory and portable configurations. Systems include precision instrumentation for data acquisition of human movement analysis and state-of-the-art surface EMG. DataLOG DataLINK General Amplifier Angle Display W4X8 DLK900 K800 UnitADU301 page 3 & 4 page 5 & 6 page 14 page 13 Data Acquisition Bluetooth and USB /or MMC card Real-time data display Bluetooth & LCD USB LCD LCD Real-time Analysis Software via Bluetooth via USB Channels up to 32 up to 32 unlimited 2 Gain Programmable Programmable Fixed Outputs to Biometrics analysis software ASCII file Analogue out to other hardware via optional R3000i via DLL to other software INPUTS ACCEPTED Analogue EMG Goniometers Accelerometers Dynamometers Pinchmeters MyoMeter Force sensors Load Cells

general single ended voltages general differential voltages Digital Contact switches Event Marker Remote Start/Stop Instrumentation Comparison Chart Page 3-4 DataLOG W4X8 Data capture, real time display & analysis using Bluetooth & MMC technologies Page 5-6 DataLINK Data capture, real time display & analysis with analogue outputs Page 7-8 Analysis Software The NEW V7 Biometrics Analysis Software is now an even more comprehensive tool for EMG, Goniometer and associated sensor analysis. Compatible with both DataLOG and DataLINK Page 9 Twin Axis Goniometers Accurate measurement of dynamic joint movement in multiple planes Page 10 Active EMG probes Precision surface electromyography Page 11 3 Axis Accelerometers Linear acceleration / vibration in three planes Page 12 Hand Dynamometer Evaluate hand grip strength with electronic accuracy Page 12 Pinchmeter Unique low profile design to measure close to end range pinch strength Page 12 Myometer Quantify muscle strength Page 13 ADU301 Angle Display Unit Hand held two channel display unit providing quick and simple readings of joint angle data Page 14

K800 Amplifier A modern microprocessor controlled general purpose amplifier system which is designed to be worn by the subject. Contents Biometrics Ltd is a world leader in the design, manufacture and distribution of technologically advanced sensors, instruments and software for the demanding nee ds in biomedical and engineering research, and educational settings. Markets include m edical, ergonomic, biomechanics, sport science, pharmaceutical and veterinary science. BiometricsLtd Sensors including electrogoniometers for precise joint range of motion measurements Advanced Surface EMG (electromyography) Portable, Wireless and Laboratory data acquisition systems Real time display and analysis software Global customers include: thousands of leading corporations, hospitals, research organizations and universities, North American, European and Asian car manufacturers, aerospace, NASA: where Biometrics technology is used exclusively for movement studies in the Human Performance Laboratory of the International Space Station. Data Acquisition Products Biometrics Ltd range of Data Acquisition Systems collect both analogue and digital data from a wide range of sensors and are available in laboratory and portable configurations. Systems include precision instrumentation for data acquisition of human movement analysis and state-of-the-art surface EMG. DataLOG DataLINK General Amplifier Angle Display W4X8 DLK900 K800 UnitADU301 page 3 & 4 page 5 & 6 page 14 page 13 Data Acquisition Bluetooth and USB /or MMC card Real-time data display Bluetooth & LCD USB LCD LCD Real-time Analysis Software via Bluetooth via USB Channels up to 32 up to 32 unlimited 2 Gain Programmable Programmable Fixed Outputs to Biometrics analysis software ASCII file Analogue out to other hardware via optional R3000i via DLL to other software INPUTS ACCEPTED Analogue EMG Goniometers Accelerometers Dynamometers

Pinchmeters MyoMeter Force sensors Load Cells general single ended voltages general differential voltages Digital Contact switches Event Marker Remote Start/Stop Instrumentation Comparison Chart Page 3-4 DataLOG W4X8 Data capture, real time display & analysis using Bluetooth & MMC technologies Page 5-6 DataLINK Data capture, real time display & analysis with analogue outputs Page 7-8 Analysis Software The NEW V7 Biometrics Analysis Software is now an even more comprehensive tool for EMG, Goniometer and associated sensor analysis. Compatible with both DataLOG and DataLINK Page 9 Twin Axis Goniometers Accurate measurement of dynamic joint movement in multiple planes Page 10 Active EMG probes Precision surface electromyography Page 11 3 Axis Accelerometers Linear acceleration / vibration in three planes Page 12 Hand Dynamometer Evaluate hand grip strength with electronic accuracy Page 12 Pinchmeter Unique low profile design to measure close to end range pinch strength Page 12 Myometer Quantify muscle strength Page 13 ADU301 Angle Display Unit

Hand held two channel display unit providing quick and simple readings of joint angle data Page 14 K800 Amplifier A modern microprocessor controlled general purpose amplifier system which is designed to be worn by the subject. Biometrics Ltd products are used world-wide in a variety of research application s including:-Biometrics Ltd maintains to the highest standard a Quality conform to the council Directive relating to Electromagnetic Management System that is independently accredited to both Compatibility by the application of BS EN 60601-1-2:1993, Medical Sports science Podiatry ISO9001:2000 and ISO13485:2003. The scope of the system and are listed with numerous international Food & Drug includes design, development, manufacture, supply, installation and Administrati ons including the United States of America. Pharmaceutical General industrial design Physiotherapy service of computer based medical systems. Ergonomic Automotive crash testing Gait analysis In addition, all systems are independently certified to Safety Standard Bioengineering Medical uses include:- Neurology of the International Electrotechnical Commission EN60601-1:1990, conform to the European Medical Device Directive 93/42/EEC, ISO9001:2000 ISO1348 5:2003 Certificate no. GB/05/66472 Certificate no. GB/05/66471 Veterinary Orthopaedics Paediatrics 1 2

PORTABLE DATA COLLECTION

STATE OF THE ART BLUETOOTH TECHNOLOGY Management & Analysis Software The NEW Biometrics Analysis software is one of the most powerful yet cost effective display & analysis software tools available. Real time display both graphically and in scientific units. Real time analysis in the new Expanded Results Table. The DataLOG Display & Analysis Software may open an unlimited number of data files and the time axis may be tracked across all files allowing display & Help Menu analysis for a large number of channels. (refer to The NEW Biometrics Analysis software pages 7 & 8). comes with a comprehensive Help menu that may be used as a tutorial for both the hardware and software. The NEW DataLOG W4X8 incorporating both Bluetooth Wireless and MMC Flashcard Technologies, provides unparalleled data capture and real time display and analysis. Developed to meet the demanding needs of researchers for portable data collection and ambulatory monitoring in medical, industrial ergonomic, sport science and educational settings. Portable Data Collection Fully Programmable, Multi Sensor Input State of the art Bluetooth Technology Real Time Data Display & Analysis Data auto-back-up using MMC Flash Card Readily Synchronize with other Systems DLL (dynamic link library) option DataLOG is a general purpose, programmable Data Acquisition Unit allowing the user to collect both analogue and digital data from a wide range of sensors. All Biometrics Ltd sensors readily connect to the DataLOG including: Single and twin axis Goniometers Torsiometers Surface EMG amplifiers Accelerometers Contact switches & Event markers MyoMeter Hand Dynamometer Pinchmeter The front end amplifier configuration and

sensor power supply are programmable enabling the researcher to also connect a wide range of custom transducers including: Load cells Strain gauge devices Single ended voltage inputs Differential voltage inputs Temperature probes Flow metres Microphones During all stages of the design and development process, attention has been given to the Bluetooth Wireless link, providing the end result of reliable real time data transfer and display. In addition, the data is automatically backed up to the MMC Flash Card providing complete peace of mind. SPECIFICATIONS DataLOG Model No. W4X8 MECHANICAL The DataLOG is configured from the host PC using the Bluetooth wireless link, including simple adjustments per channel for gain, power supply, sampling rate a nd datum or zero settings. When Biometrics sensors are connected these parameters are automatically selected using a drop down menu. Data recording options include: display and analyse real time within the PC via Bluetooth store on the PC and auto-back-up to the MMC Flash Card store data to the MMC card for later download transfer real time using the Dynamic Link Library into 3rd party programs using tools such as Microsoft Visual Basic or Visual C++ store as ASCII or as a standard Sound Wave file for passing into other applications such as Microsoft Excel or Cool Edit. display real time on the Graphics Display as a digital readout in engineering units, or as a bar chart, or as adjustable audible alarms. Synchronisation options for 16, 24 or 32 channels For applications requiring greater than 8 analogue or 4 digital channels, the DataLOGs are set-up in record to MMC card only mode, and then multiple units may be synchronized using one of the following cables:SYNC2 To synchronize 2 DataLOGs for up to 16 analogue and 10 digital channels of data acquisition recording to MMC card only. SYNC3 To synchronize 3 DataLOGs for up to 24 analogue and 15 digital channels of data acquisition recording to MMC card only. SYNC4 To synchronize 4 DataLOGs for up to 32 analogue and 20 digital channels of data acquisition recording to MMC card only. A graphics LCD provides a display of the unit status and a simple user interface . A keypad provides the following facilities: Manual start and manual stop recording. Manual start with pre-set automatic stop. Zero a specific channel or all channels simultaneously. Erase the last recording or all recordings. Display of real time inputs as numerical values in engineering units or as a bar graph. DataLOG Accessories: SYNCHRONIZATION CABLE SYNC1 For remote start / stop by a TTL signal {i.e. the ability to switch a signal lin e from logic 1 (+5V) to logic 0 (+0)} sent from other hardware systems to synchronise data collection from multiple sources. The SYNC1 is a 2 metre cable with a

connector at one end to connect to the digital input socket of the DataLOG and 2 flying wires at the other end. Alternatively, this cable may be specified with a ny connector of choice. OPTICAL SYNCHRONISATION USING START SWITCH IS2-LED A 1.8 metre cable with a suitable connector at one end to temporarily connect to the DataLOG, and a hand held switch with LED at the other. Pressing the switch will activate the start recording function and illuminate a LED which may be use d for precise synchronization with camera based motion analysis systems. EVENT MARKER IS3 A 1.8 meter cable with a suitable connector at one end to connect to the DataLOG, and a hand held switch at the other. This useful accessory allows time marks to be superimposed on the recorded data. CONTACT SWITCH ASSEMBLY FS4 An assembly of 4 Force Sensing Resistor Sensors (FSRs) each on 1.2 meters of cable which are readily connected to the DataLOG via one connector for use as switches to indicate contact e.g. heel and toe strike or palmer contact. The sensors are thin and robust and are usually placed inside the subject s shoe or glove for convenience. Portable Systems The Portable Systems are comprehensive packages of sensors and instrumentation for static and dynamic measurements in clinical settings, research centres, or any remote location such as a workplace. Dimensions 158 x 95 x 33 mm Mass 380g Battery type 4 x Alkaline AA, LR6, MN1500 Battery life 8 hours nominal Analogue channels 8 Digital channels 5 Memory internal MMC Flash Card Technology Bluetooth Adaptor Microsoft Bluetooth stack compatible Front end ADC 13 bit giving +/- 4000 counts resolution Range of Sampling frequency per channel 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000, 1250, 2000, 2500, 5000, 10000, 20000 Hz (note: record in Bluetooth mode limited to total 8 KHz, MMC only mode 55KHz) Power supply per channel adjustable 0 to 4.6 Vdc Current supply per channel = 20mA. Accuracy better than +/- 0.75% full scale Maximum Common Mode 1.2 V DataLOG Analogue Inputs Window The Analogue Inputs window is used to set up all the parameters relating to the analogue channels. DataLOG Digital Inputs Window

This window controls the operation of the digital inputs and the auxiliary start/stop recording input. BANDWIDTH INPUT RANGE BANDWIDTH 1mV and 3mV ranges DC to 1 KHz (+0 dB / -3 dB) 10mV to 3V ranges DC to 10 KHz (+0 dB / -3 dB) TYPICAL PC SYSTEM REQUIREMENTS Processor Pentium 2.8GHz RAM 1GB Operating platform XP or XP Professional Disk Drive CD ROM USB port 2.0 2 Graphic card 128MB graphics RAM Bluetooth adaptor Microsoft Bluetooth stack compatible CABLES TYPE NUMBER LENGTH (mm) DESCRIPTION J500 500 Connection of Goniometers & Torsiometers to DataLOG J1000 1000 Connection of Goniometers & Torsiometers to DataLOG J1500 1500 Connection of Goniometers & Torsiometers to DataLOG D1500 1500 Connection of general sensors to DataLOG H1800 1800 Connection of MyoMeter, Dynamometer and Pinchmeter to DataLOG 4 General analogue channels may be single ended or differential dependent on front end plug wiring configuration Hardware Gain range options Gain x 1000 x 300 x 100 x 30 x 10 x 3 x 1 Max Input 1 mV 3 mV 10 mV 30 mV 100 mV 300 mV 1 V Resolution 0.244 V 0.732 V 2.44 V 7.32 V 24.4 V 73.2 V

0.244 mV x 0.3 3 V 0.732 mV Recording mode (3 options) record to Bluetooth & MMC record to MMC only record to Bluetooth only 3

DataLINK is an on-line general purpose subject worn programmable Data Acquisition System allowing the user to collect both analogue and digital data from a wide range of sensors including Biometrics Goniometers, Torsiometers, active EMG sensors, Accelerometers, MyoMeter, Pinchmeter, Hand Dynamometer and Contact Switches. DataLINK is an on-line general purpose subject worn programmable Data Acquisition System allowing the user to collect both analogue and digital data from a wide range of sensors including Biometrics Goniometers, Torsiometers, active EMG sensors, Accelerometers, MyoMeter, Pinchmeter, Hand Dynamometer and Contact Switches. SPECIFICATIONS [ DataLINK Model No. DLK900 ] analogue channels 8 digital channels 5 MECHANICAL Subject Unit Dimensions Mass 130 x 65 x 25 mm 200g Base Unit Dimensions Mass 173 x 154 x 60 mm 360g Examples of other general sensor inputs include load cells, strain gauges, potentiometers, temperature probes and flow metres. The data is transferred from the Subject Unit to the tabletop Base Unit via a RS485 data transfer cable. This cable (type no. R7000) is 7 metres in length but may be specified any length up to 15 metres. The Base Unit connects to the PC using a USB port where the data may readily be stored on disk or passed real time into other applications such as Microsoft Excel or Microsoft Visual Basic using the DLL (dynamic link library). Analogue outputs may be obtained using the optional output cable type no. R2000I. On Line Data Collection Real Time Display & Analysis 40KHz total Sampling Frequency per DataLINK Readily Synchronized with other Systems 8, 16, 24 or 32 analogue channels Audible threshold alarms. DataLINK comes with 8 analogue inputs, accommodating both single ended voltage inputs and differential voltage inputs, and 5 digital inputs. The easy to use Management Software may simultaneously control up to 4 DataLINK units giving the researcher the flexibility of up to 32 analogue channels and 20 digital channels. Each of the channels is individually controlled with options for selectable gain, sampling frequency, sensor supply voltage and zero position. The DataLINK Display & Analysis Software may display and analyze real time up to 32 analogue channels and 20 digital channels, and may open post data collection an unlimited number of files allowing display & analysis for a large number of channels, (refer to pages 7 & 8).

CONTACT SWITCH ASSEMBLY FS4 An assembly of 4 Force Sensing Resistor Sensors (FSRs) each on 1.2 metres of cable which are readily connected to the DataLINK via one connector for use as switches to indicate contact e.g. heel and toe strike or palmer contact. The sensors are thin and robust and are usually placed inside the subject s shoe or glove for convenience. SYNCHRONIZATION CABLE SYNC1 For remote start / stop by a TTL signal {i.e. the ability to switch a signal line from logic 1 (+5V) to logic 0 (+0)} sent from other hardware systems to synchronise data collection from multiple sources. The SYNC1 is a 2 metre cable with a connector at one end to connect to the digital input socket of the DataLOG and 2 flying wires at the other end. Alternatively, this cable may be specified with any connector of choice. EVENT MARKER IS2 A 1.8 metre cable with a suitable connector at one end to connect to the DataLINK, and a hand held switch at the other. This accessory allows time marks to be superimposed on the recorded data highlighting specific points during data collection. OPTICAL SYNCHRONIZATION USING START SWITCH IS2-LED As above but with a LED built into the hand held switch for use to activate start recording for precise synchronization with camera based motion analysis systems. LABORATORY SYSTEMS The Laboratory Systems package the DataLINK with the most often requested Biometrics sensors in either basic or enhanced configurations. The LS800 Goniometer System comes with the DataLINK, Management & Analysis software, 6 goniometers (choice of sizes to accommodate upper & lower extremity), the IS2 event marker and the FS4 contact switch assembly. The LS850 EMG System is dedicated to EMG measurements and comes with the DataLINK, Management & Analysis software, 8 active EMG sensors, R206 earthing strap, T350 adhesive tape and IS2-LED event marker. The LS900 Goniometer & EMG System combines movement analysis with surface EMG measurements in a complete east to use, affordable system and comes with the DataLINK, Management & Analysis software, 6 goniometers (choice of sizes to accommodate upper & lower extremity), 1 Torsiometer, 4 active EMG sensors, R206 earthing strap, T350 adhesive tape, IS2-LED event marker and FS4 contact switch Assembly. DataLINK DataLINK Analogue Inputs Window Digital Inputs Window The Analogue Inputs window is used This window controls the operation to set up all the parameters relating of the digital inputs and the auxiliary to the analogue channels. start/ stop recording input. ELECTRICAL Mains powered rated continuous or powered via USB port. Microprocessor controlled programmable gain amplifiers

Front end ADC 13 bit giving +/- 4000 counts Communication with host PC USB Communication from Subject unit to Base unit via RS485 General analogue channels may be single ended or differential dependent on front end plug wiring configuration. Hardware Gain range options Gain Max Input Resolution x 1000 1 mV 0.244 V x 300 3 mV 0.732 V x 100 10 mV 2.44 V x 30 30 mV 7.32 V x 10 100 mV 24.4 V x 3 300 mV 73.2 V x 1 1 V 0.244 mV x 0.3 3 V 0.732 mV 5 Help Menu The NEW Biometrics Analysis software comes with a comprehensive Help menu that may be used as a tutorial to use both the hardware and software. Management and Analysis Software The NEW Biometrics Analysis software is one of the most powerful yet cost effective display & analysis software tools available. The usefulness and simplicity of this accurate real time display and real time analysis are excellent for both research and educational settings. CABLES TYPE NUMBER LENGTH (mm) DESCRIPTION Range of Sampling frequency 10, 20, 50, 100, 200, 500, D1500 1500 Connection of general sensors to DataLINK. per analogue channel 1000, 2000, 5000 Hz J500 500 Connection of Goniometers & To rsiometers to DataLINK

(maximum 40 KHz sequential) J1000 1000 Connection of Goniometers & Torsiometers to DataLINK Bandwidth +0 / -1dB up to 2.5 KHz J1500 1500 Connection of Goniometers & Torsiom eters to DataLINK Power supply per channel 0 to 4,950 mV dc R7000 7000 RS422 cable from Subject Un it to Base Unit Current supply per channel < 20 mA. USB1800 1800 USB cable from Base unit to PC R2000I 2000 Optional analogue and digital output cable Accuracy better than 0.75 % full scale. H1800 1800 Connection of Pinchmeter, Dynamometer & MyoMeter Data interface USB or analogue output via DACs contained in base unit. TYPICAL SYSTEM REQUIREMENTS Processor Pentium 2.8GHz Analogue Output Sensitivity RAM 1GB Count Equivalent Analogue Output Equivalent Goniometer Angle Operating platform XP or XP Professional + 4000 +4.0 Vdc +180 Disk Drive CD ROM 0 +2.0 Vdc 0 USB port 2.0 1 per DataLINK DLK900 -4000 +0.0 Vdc - 180 Graphic card 128MB graphics RAM 6

File Name Channel ( trace number) Trace Title Filters used Scientific Units Start time in hours:minutes:seconds.mS End time in hours:minutes:seconds.mS Time Span Top marker (if applied) in engineering units Bottom Marker (if applied) in engineering units Difference Marker Over Excursions number of excursions over the Top marker. The minimum time above the marker to count as an excursion is set by the user with a default value of 0.1 seconds Under Excursions number of excursions below the Bottom marker. The minimum time below the marker to count as an excursion is set by the user with a default value of 0.1 seconds Start Value for time markers (if applied) End Value for time markers (if applied) Difference/sec for the marked time Trend calculated using Linear Regression Analysis Maximum Value Time to Maximum Minimum Value Time to Minimum Mean Value Repetitions The Expanded Results Table may be copied to the clipboard and pasted into other applications, such as MS Excel, for further analysis and printing of results. OTHER FEATURES INCLUDE: Open an unlimited number of data files with the option to track the time axis across all files allowing display and analysis for a large number of channels. Waveform display in multiple windows and formats with full zoom, scroll, and area marking facilities, option to split, tile and cascade windows. Waveforms within the same window may be viewed overlaid or as separate traces. Easily toggle

between the two views with a simple keystroke. Engineering units with custom scaling ability on all traces independently. Each recorded file is date and time stamped. Full trace management (change line width, colour, background colour, etc.) Ability to set an unlimited number of vertical cursors (time markers) to a single trace, all traces in a window, and across multiple windows giving total flexibility. All values are shown simultaneously in the expanded results table. All vertical cursors may be altered via expanded results table by typing in time values to 0.001S giving maximum control. All horizontal cursors may be altered via expanded results table by typing in Y value to 0.01 giving maximum control. Filters Up to six filters may be applied to each trace Copy filters set on a channel to all other channels in 1 simple operation A memory store & recall (2 memory settings) for the filters set on a channel to easily be applied to any other channel. These memory settings are kept stored indefinitely until changed by the user Filters include: Rectify Integrate EMG Work Done (new in v7) Average Offset LPF 1st Order (new in v7) RMS Scale Acceleration (new in v7) Velocity Mean Frequency Median Frequency 9. Versatile Data Export for import into other applications for further analysis ASCII export of raw data ASCII export traces, after filters have been applied, in engineering units Wave file format

10. Expanded ability to include text notes with data files 11. Power Spectrum Graph 12. X-Y graphs 13. FFT high pass filters: remove DC, remove very low frequencies 14. FFT window functions: Rectangle/Flat top Blackmann standard Hamming Triangle/Bartlett Blackmann Opt Hann 15. Comprehensive Help menu that may be used as a tutorial for both the hardware and software operations. Inputs & Alarms The analogue and digital inputs are displayed in engineering units during data acquisition. Audible & visible high and/or low alarms may be set to any or all of the channels. Data Export Saved data can be exported in a variety of formats for importation into other applications. Graph Key The Graph Key window controls the traces that are to be displayed and the units used on the Y axis. Settings The Settings window controls the application of filters to the displayed data. The parameters for excursions and repetitions can be varied. NEW V7 Biometrics Analysis Software for DataLOG W4X8 (Wireless) DataLOG P3X8 (USB) DataLINK DLK900 The Biometrics Analysis Software is now an even more comprehensive tool for EMG, Goniometer and associated sensor analysis. Two major NEW key features have been added in version 7. The new Expanded Results Table showing all results of all channels simultaneously. Multiple traces/graphs/windows from a single file or from multiple files may be compared. The spreadsheet style table displays the following data for each trace: Create and save Workspaces. A Workspace is the complete appearance of the application along with the settings used within the program. This includes: The names of all open data files The position and size of all windows The position, size and appearance of all application toolbars and tool windows Application preferences and options

All markers and filters All zoom and scroll settings Multiple workspaces may be saved. In addition, when the application is closed, the current complete workspace is automatically saved in a file called Workspace when last closed . The workspace with the associated data files may be saved as a ZIP file which can be extracted using many third party applications. This facilitates electronic mailing of the data analysis results. File Name Channel ( trace number) Trace Title Filters used Scientific Units Start time in hours:minutes:seconds.mS End time in hours:minutes:seconds.mS Time Span Top marker (if applied) in engineering units Bottom Marker (if applied) in engineering units Difference Marker Over Excursions number of excursions over the Top marker. The minimum time above the marker to count as an excursion is set by the user with a default value of 0.1 seconds Under Excursions number of excursions below the Bottom marker. The minimum time below the marker to count as an excursion is set by the user with a default value of 0.1 seconds Start Value for time markers (if applied) End Value for time markers (if applied) Difference/sec for the marked time Trend calculated using Linear Regression Analysis Maximum Value Time to Maximum Minimum Value Time to Minimum Mean Value Repetitions The Expanded Results Table may be copied to the clipboard and pasted into other applications, such as MS Excel, for further analysis and printing of results. OTHER FEATURES INCLUDE: Open an unlimited number of data

files with the option to track the time axis across all files allowing display and analysis for a large number of channels. Waveform display in multiple windows and formats with full zoom, scroll, and area marking facilities, option to split, tile and cascade windows. Waveforms within the same window may be viewed overlaid or as separate traces. Easily toggle between the two views with a simple keystroke. Engineering units with custom scaling ability on all traces independently. Each recorded file is date and time stamped. Full trace management (change line width, colour, background colour, etc.) Ability to set an unlimited number of vertical cursors (time markers) to a single trace, all traces in a window, and across multiple windows giving total flexibility. All values are shown simultaneously in the expanded results table. All vertical cursors may be altered via expanded results table by typing in time values to 0.001S giving maximum control. All horizontal cursors may be altered via expanded results table by typing in Y value to 0.01 giving maximum control. Filters Up to six filters may be applied to each trace Copy filters set on a channel to all other channels in 1 simple operation A memory store & recall (2 memory settings) for the filters set on a channel to easily be applied to any other channel. These memory settings are kept stored indefinitely until changed by the user Filters include: Rectify Integrate EMG Work Done (new in v7) Average Offset LPF 1st Order (new in v7) RMS Scale

Acceleration (new in v7) Velocity Mean Frequency Median Frequency 9. Versatile Data Export for import into other applications for further analysis ASCII export of raw data ASCII export traces, after filters have been applied, in engineering units Wave file format 10. Expanded ability to include text notes with data files 11. Power Spectrum Graph 12. X-Y graphs 13. FFT high pass filters: remove DC, remove very low frequencies 14. FFT window functions: Rectangle/Flat top Blackmann standard Hamming Triangle/Bartlett Blackmann Opt Hann 15. Comprehensive Help menu that may be used as a tutorial for both the hardware and software operations. Inputs & Alarms The analogue and digital inputs are displayed in engineering units during data acquisition. Audible & visible high and/or low alarms may be set to any or all of the channels. Data Export Saved data can be exported in a variety of formats for importation into other applications. Graph Key The Graph Key window controls the traces that are to be displayed and the units used on the Y axis. Settings The Settings window controls the application of filters to the displayed data. The parameters for excursions and repetitions can be varied. NEW V7 Biometrics Analysis Software for DataLOG W4X8 (Wireless) DataLOG P3X8 (USB) DataLINK DLK900 The Biometrics Analysis Software is now an even more comprehensive tool for EMG, Goniometer and associated sensor analysis. Two major NEW key features have been added in version 7. The new Expanded Results Table showing all results of all channels simultaneously. Multiple traces/graphs/windows from a single file or from multiple files may be compared. The spreadsheet style table displays the following data for

each trace: Create and save Workspaces. A Workspace is the complete appearance of the application along with the settings used within the program. This includes: The names of all open data files The position and size of all windows The position, size and appearance of all application toolbars and tool windows Application preferences and options All markers and filters All zoom and scroll settings Multiple workspaces may be saved. In addition, when the application is closed, the current complete workspace is automatically saved in a file called Workspace when last closed . The workspace with the associated data files may be saved as a ZIP file which can be extracted using many third party applications. This facilitates electronic mailing of the data analysis results. 78

The SG series twin axis goniometers and Q series single axis torsiometers provide excellent mechanical integrity and electrical performance. Biometrics sensors are sold separately or as part of complete measurement systems. Available systems range from instrumentation for simple static angle readout, through to fully portable wireless data collection. In general, there are no fixed rules governing which size of sensor is most suitable for a specific joint; this depends on the size of the subject. The sensor must be capable of reaching across the joint so that the two end blocks can be mounted where least movement occurs between the skin and underlying skeletal structure. In certain circumstances more than one size of sensor will be appropriate. The table below is given for guidance only and refers to an adult population. Size used will vary within paediatrics. Generally speaking the endblock where the cables are connected is mounted proximally to aid with cable management. TWIN AXIS GONIOMETERS SG65, SG75, SG110, SG110A, SG150, SG150B The SG series twin axis goniometers simultaneously measure angles in up to two planes of movement. For example, to measure wrist movements, the endblocks of the SG65 or SG75 goniometer are attached on the dorsal surface using double sided tape, (type. No. T10), the distal end over the third metacarpal, the proximal over the midline of the forearm, with the wrist in the neutral position. The goniometer has two separate output connectors, one measures flexion/extension, the other radial/ulnar deviation. When used to measure a single axis joint such as the knee or elbow, or when measuring a single plane of a twin axis joint, simply connect one channel, the other remains redundant. All twin axis SG series goniometers function the same way, the difference being physical size. SINGLE AXIS GONIOMETER F35 Biometrics goniometer F35 measures angles in one plane. This small goniometer is designed to measure flexion/extension of finger and toe joints. SINGLE AXIS TORSIOMETERS Q110 and Q150 Biometrics Ltd Q series single axis torsiometers are designed for measurement of rotations in one plane, e.g. forearm pronation/supination or neck axial rotation. If the torsiometer is bent nominally in planes X-X or Y-Y the output remains constant. All torsiometers function in the same way, the difference being physical size. DATA DISPLAY AND ANALYSIS The NEW V7.0 Analysis software for both Wireless DataLOG & DataLINK provides the following statistical analysis for all goniometry data including:An gular displacements, velocities and accelerations; Min, max, mean, repetitions, number of events over or under a set threshold, percentage time spent in and out of set limits, time to max, time to min etc. (refer to pages 7 & 8 for details) Q150 Q110 [ 3 ] D A C E SG110/A SG65 SG110 SG150

SG150/B [ 2 ] F35 [ 1 ]Angle Sensors The comprehensive range of Biometrics goniometers and torsiometers are ideal for quick, accurate measurements of joint movement in multiple planes. Extremely robust, lightweight and flexible, the sensors can be comfortably worn undetected under clothing, without hindering the actual joint movement of the subject. BiometricsLtd Depending on application and budget, the active probe type no. SX230 readily connects to the wireless DataLOG, tethered DataLINK or tethered general amplifier K800. All 3 instruments may be used to record and display EMG only, or may be used in conjunction with associated Biometrics Ltd sensors including goniometers, myometer, accelerometers, dynamometer, pinchmeter etc. Biometrics Ltd EMG systems may be synchronised with active camera based motion systems such as Vicon, Qualisys and Peak Performance, and 3 D force plate systems such as Kistler and AMTI. The Biometrics Ltd EMG systems highlighted in this brochure are aimed at a wide range of research applications including: Symmetry studies during gait Timing studies in Biomechanics Work done and fatigue studies Work environment and tool design Sports science Neuro Rehabilitation The SX230 Active EMG Sensor The SX230 is a pre amplifier designed and manufactured by Biometrics Ltd providing ease of use and a superb quality signal. Unique to the design is the Input Impedance of > 10,000,000 M Ohms. What this means in practice is that little or no skin preparation and no conducting gels or creams are required, yet the quality of the signal recorded is absolutely superb for both static and dynamic applications. Simply apply the electrodes over the body of the small or large muscles being measured using the die cut medical grade double sided adhesive tape (part no. T350). Independent of the number of active EMG sensors being used at any one time only one ground reference cable is required. Taking EMG measurements The SX230 may readily connect to the DataLOG, DataLINK or K800. These instruments are general purpose data collection devices and may collect signals from a wide range of sensors simultaneously with the EMG. This is ideal for correlation of muscle activity with other physiological parameters. Graphs showing EMG (abdominal muscles) and hip movement with EMG Power Spectrum. Note this trace is raw data and NO filtering has been applied to reduce artefacts. Data collected using DataLOG, active EMG sensors SX230 and SG150 Goniometer. R206, T350SX230 Biometrics Ltd offers a technologically advanced yet cost effective range of EMG Display & Data Capture

Systems offering both fully portable and real time display & analysis options. The SG series twin axis goniometers and Q series single axis torsiometers provide excellent mechanical integrity and electrical performance. Biometrics sensors are sold separately or as part of complete measurement systems. Available systems range from instrumentation for simple static angle readout, through to fully portable wireless data collection. In general, there are no fixed rules governing which size of sensor is most suitable for a specific joint; this depends on the size of the subject. The sensor must be capable of reaching across the joint so that the two end blocks can be mounted where least movement occurs between the skin and underlying skeletal structure. In certain circumstances more than one size of sensor will be appropriate. The table below is given for guidance only and refers to an adult population. Size used will vary within paediatrics. Generally speaking the endblock where the cables are connected is mounted proximally to aid with cable management. TWIN AXIS GONIOMETERS SG65, SG75, SG110, SG110A, SG150, SG150B The SG series twin axis goniometers simultaneously measure angles in up to two planes of movement. For example, to measure wrist movements, the endblocks of the SG65 or SG75 goniometer are attached on the dorsal surface using double sided tape, (type. No. T10), the distal end over the third metacarpal, the proximal over the midline of the forearm, with the wrist in the neutral position. The goniometer has two separate output connectors, one measures flexion/extension, the other radial/ulnar deviation. When used to measure a single axis joint such as the knee or elbow, or when measuring a single plane of a twin axis joint, simply connect one channel, the other remains redundant. All twin axis SG series goniometers function the same way, the difference being physical size. SINGLE AXIS GONIOMETER F35 Biometrics goniometer F35 measures angles in one plane. This small goniometer is designed to measure flexion/extension of finger and toe joints. SINGLE AXIS TORSIOMETERS Q110 and Q150 Biometrics Ltd Q series single axis torsiometers are designed for measurement of rotations in one plane, e.g. forearm pronation/supination or neck axial rotation. If the torsiometer is bent nominally in planes X-X or Y-Y the output remains constant. All torsiometers function in the same way, the difference being physical size. DATA DISPLAY AND ANALYSIS The NEW V7.0 Analysis software for both Wireless DataLOG & DataLINK provides the following statistical analysis for all goniometry data including:An gular displacements, velocities and accelerations; Min, max, mean, repetitions, number of events over or under a set threshold, percentage time spent in and out of set limits, time to max, time to min etc. (refer to pages 7 & 8 for details) Q150 Q110 [ 3 ] D A C E SG110/A SG65 SG110

SG150 SG150/B [ 2 ] F35 [ 1 ]Angle Sensors The comprehensive range of Biometrics goniometers and torsiometers are ideal for quick, accurate measurements of joint movement in multiple planes. Extremely robust, lightweight and flexible, the sensors can be comfortably worn undetected under clothing, without hindering the actual joint movement of the subject. BiometricsLtd Depending on application and budget, the active probe type no. SX230 readily connects to the wireless DataLOG, tethered DataLINK or tethered general amplifier K800. All 3 instruments may be used to record and display EMG only, or may be used in conjunction with associated Biometrics Ltd sensors including goniometers, myometer, accelerometers, dynamometer, pinchmeter etc. Biometrics Ltd EMG systems may be synchronised with active camera based motion systems such as Vicon, Qualisys and Peak Performance, and 3 D force plate systems such as Kistler and AMTI. The Biometrics Ltd EMG systems highlighted in this brochure are aimed at a wide range of research applications including: Symmetry studies during gait Timing studies in Biomechanics Work done and fatigue studies Work environment and tool design Sports science Neuro Rehabilitation The SX230 Active EMG Sensor The SX230 is a pre amplifier designed and manufactured by Biometrics Ltd providing ease of use and a superb quality signal. Unique to the design is the Input Impedance of > 10,000,000 M Ohms. What this means in practice is that little or no skin preparation and no conducting gels or creams are required, yet the quality of the signal recorded is absolutely superb for both static and dynamic applications. Simply apply the electrodes over the body of the small or large muscles being measured using the die cut medical grade double sided adhesive tape (part no. T350). Independent of the number of active EMG sensors being used at any one time only one ground reference cable is required. Taking EMG measurements The SX230 may readily connect to the DataLOG, DataLINK or K800. These instruments are general purpose data collection devices and may collect signals from a wide range of sensors simultaneously with the EMG. This is ideal for correlation of muscle activity with other physiological parameters. Graphs showing EMG (abdominal muscles) and hip movement with EMG Power Spectrum. Note this trace is raw data and NO filtering has been applied to reduce artefacts. Data collected using DataLOG, active EMG sensors SX230 and SG150 Goniometer. R206, T350SX230 Biometrics Ltd offers a technologically advanced yet

cost effective range of EMG Display & Data Capture Systems offering both fully portable and real time display & analysis options. JOINT SENSOR MEASURED OUTPUT wrist SG65 flexion/extension, radial/ulnar deviation wrist (large) SG75 flexion/extension, radial/ulnar deviation forearm Q150 pronation/supination elbow SG110 flexion/extension ankle SG110 or SG110/A dorsiflexion/plantarflexion, inversion/eversion SPECIFICATION SX230 knee hip SG150 SG150 flexion/extension flexion/extension, abduction/adduction SPECIFICATIONS ( refer to figure [ 3 ] ) Electrodes Gain ix 1000 back SG150/B flexion/extension/lateral flexion SG65 SG75 SG110 SG110/A SG150 SG1 50/B Q110 Q150 F35 Bandwidth neck SG110 flexion/extension, lateral flexion Number of Noise < 5 V neck Q110 axial rotation Channels 2 2 2 2 2 2 1 1 1 Input impedancefinger DIP, P IP, MCP F35 flexion/extension A. Max 65 75 110 110 150 150 110 150 35 Supply vol tageTransducer type strain gauge A. Min 30 30 70 70 100 50 70 100 30 Life1 600,000 cycles typical B. 55 60 60 60 70 120 60 70 18 CMRR @ 60 Hz (dB) Accuracy 2 measured over a range of 90 C. 18 18 18 18 18 18 18 18 8 110 dB) Repeatability 1 measured over a range of 90 D. 54 54 54 18 54 54 54 54 15 Cable Operating temperature range +10C to +40C E. 18 18 18 54 18 18 18 18 8 Temperature zero drift = 0.15 degrees angle / C Weight (g) 15 15 17 25 19 25 17 1 9 8 direct connection to instrumentation (custom 12 g (excluding cable & Type Cable Application of application. 20,00 206 0,75 10 38 ntegral dry reusable Plug Ground Reference Part no. R206 reusable highly flexible grade, > 10,000,000 M Ohms wiring on request) 20 Hz 450 Hz Biometrics Ltd

length 1.25m +4.0 to 5.0 Vdc Mass

(custom lengths on request) wrist strap or user Electrostatic discharge circuit protected > 96 dB (typically connector) preference highly flexible grade, Application Tape Part no. T350 Double sided medical grade Die cut for ease lengths on request) length 1.25 m (custom 10 Dimension mm 9

Features - both models 3 independent axes, X, Y, Z variable full scale measuring range (adjusted within DataLINK or DataLOG management software, 100%, 30% or 10% of full scale) 3 levels of adjustable frequency response 8th order anti-aliasing filter on each channel with user selectable corner frequencies Non critical input power requirements SPECIFICATIONS Model ACL300 S3-1000G-HA Range +/- 10G +/- 1000G Mass 10g 8g Dimensions 19.0 x 12.7 x 10.9 mm (L x D x H) 14 x 13 x 14 mm Case material anodised aluminium Titanium alloy selected corner frequency. The filter has 3 values, which are selected by positi oning a simple switch within the accelerometer interface unit. The following table shows the possible set corner frequencies and the recommende d The M500 MyoMeter is held by the examiner with the curved anvil placed against the body part to be tested. The limb is stabilized and held in the desired starting position. The patient is instructed to hold the limb in position and resist the force applied by the examiner. The examiner applies force gradually until the limb is depressed. The force required to move the limb is referred to as the breaking force . The M500 MyoMeter is supplied with two anvils: 1 x general purpose (small) 1 x general purpose (large) By connecting the M500 MyoMeter to the DataLOG or the DataLINK and using the management & analysis software, force may be displayed and analysed in units of Newtons, Kg or lb. The M500 may also be connected to the general purpose amplifier K800 for direct connection to 3rd party instruments such as A/D cards. Accelerometers - 3 axes 2 model options:Model ACL300 range +/- 10G Model S3-1000G-HA range +/- 1000G Both models of accelerometer provide a complete ready to go solution for measurements of acceleration in 3 axes. MyoMeter M500 The M500 allows the user to quantify the force applied during Manual Muscle Testing. Manual Muscle Testing is a procedure for the evaluation of the function and strength of individual muscles and muscle groups based on effective performance of a movement in relation to the forces of gravity and manual resistance. Electronic calibration adjustments giving high stability under vibration and over time Signal conditioning electronics housed in a separate small enclosure allowing for miniaturization of the accelerometer probe By simply plugging either accelerometer model into the Biometrics DataLOG, DataLINK or K800 instruments, accelerations may be displayed

& analysed in units of G or m/s2 . The small lightweight active head may be mounted practically anywhere using double sided adhesive tape, or held securely in place using a mechanical clamp for higher loading. There is no need to calibrate either model as this is done during manufacture. They are ready to go giving accurate readings for both static and dynamic applications. MYOMETER M500 SPECIFICATIONS Dimensions 115 x 65 x 32 mm Mass 250 g Accuracy better than 1% RL Rated Load (RL) 0 to 500N Calibrated and designed to work in compression only. Anvils 1 small, 1 large Cable Direct connection to DataLOG, DataLINK and K800 using cable type no. H1800 Pinchmeter P100 The unique electronic pinchmeter has a low profile design that enables the researcher to accurately quantify pinch strength at closer to end range than any other device. Graphs showing extensor EMG and 5 repetitions of maximum grip strength of a normal subject, with EMG Power Spectrum. Note this trace is raw data and NO filtering has been applied to reduce artefacts. Data collected using DataLINK, active EMG sensor SX230 and hand dynamometer G100. Dynamometer G100 The Biometrics Dynamometer utilises precision load cell technology to increase the sensitivity and accuracy of measurement of even very low grip strength forces. By using the industry standard Jamar design exterior researchers can compare with standardised normative data. Total accuracy is better than 1%. Full scale 0-90Kg or 0-200lbs. Features - both models 3 independent axes, X, Y, Z variable full scale measuring range (adjusted within DataLINK or DataLOG management software, 100%, 30% or 10% of full scale) 3 levels of adjustable frequency response 8th order anti-aliasing filter on each channel with user selectable corner frequencies Non critical input power requirements SPECIFICATIONS Model ACL300 S3-1000G-HA Range +/- 10G +/- 1000G Mass 10g 8g Dimensions 19.0 x 12.7 x 10.9 mm (L x D x H) 14 x 13 x 14 mm

Case material anodised aluminium Titanium alloy selected corner frequency. The filter has 3 values, which are selected by positi oning a simple switch within the accelerometer interface unit. The following table shows the possible set corner frequencies and the recommende d The M500 MyoMeter is held by the examiner with the curved anvil placed against the body part to be tested. The limb is stabilized and held in the desired starting position. The patient is instructed to hold the limb in position and resist the force applied by the examiner. The examiner applies force gradually until the limb is depressed. The force required to move the limb is referred to as the breaking force . The M500 MyoMeter is supplied with two anvils: 1 x general purpose (small) 1 x general purpose (large) By connecting the M500 MyoMeter to the DataLOG or the DataLINK and using the management & analysis software, force may be displayed and analysed in units of Newtons, Kg or lb. The M500 may also be connected to the general purpose amplifier K800 for direct connection to 3rd party instruments such as A/D cards. Accelerometers - 3 axes 2 model options:Model ACL300 range +/- 10G Model S3-1000G-HA range +/- 1000G Both models of accelerometer provide a complete ready to go solution for measurements of acceleration in 3 axes. MyoMeter M500 The M500 allows the user to quantify the force applied during Manual Muscle Testing. Manual Muscle Testing is a procedure for the evaluation of the function and strength of individual muscles and muscle groups based on effective performance of a movement in relation to the forces of gravity and manual resistance. Electronic calibration adjustments giving high stability under vibration and over time Signal conditioning electronics housed in a separate small enclosure allowing for miniaturization of the accelerometer probe By simply plugging either accelerometer model into the Biometrics DataLOG, DataLINK or K800 instruments, accelerations may be displayed & analysed in units of G or m/s2 . The small lightweight active head may be mounted practically anywhere using double sided adhesive tape, or held securely in place using a mechanical clamp for higher loading. There is no need to calibrate either model as this is done during manufacture. They are ready to go giving accurate readings for both static and dynamic applications. MYOMETER M500 SPECIFICATIONS Dimensions 115 x 65 x 32 mm Mass 250 g Accuracy better than 1% RL Rated Load (RL) 0 to 500N Calibrated and designed to work in compression only.

Anvils 1 small, 1 large Cable Direct connection to DataLOG, DataLINK and K800 using cable type no. H1800 Pinchmeter P100 The unique electronic pinchmeter has a low profile design that enables the researcher to accurately quantify pinch strength at closer to end range than any other device. Graphs showing extensor EMG and 5 repetitions of maximum grip strength of a normal subject, with EMG Power Spectrum. Note this trace is raw data and NO filtering has been applied to reduce artefacts. Data collected using DataLINK, active EMG sensor SX230 and hand dynamometer G100. Dynamometer G100 The Biometrics Dynamometer utilises precision load cell technology to increase the sensitivity and accuracy of measurement of even very low grip strength forces. By using the industry standard Jamar design exterior researchers can compare with standardised normative data. Total accuracy is better than 1%. Full scale 0-90Kg or 0-200lbs. supply voltage +4.50 to +5.50 Vdc +4.50 to +5.50 Vdc Sensitivity 100mV / G 1mV / G Cross talk < 5% < 5% Accuracy better than 2 % full scale better than 2 % full scale Bandwidth DC to 100, 500, 1000 Hz DC to 1250, 2500, 5000 Hz filter 8 pole, 8th order 1.2 Elliptic. 8 pole, 8th order 1.2 Elliptic. Shock survival 500 G 5000 G Bandwidth Limiting (cut-off) Filters Each channel of both models of accelerometer are fitted with an 8th order 1.2 el liptic filter with user selectable cut-off frequencies. This provides the optimum compromise b etween pass-band ripple and roll-off steepness; 60 dB of rejection is achieved at 1.2 t imes the sampling frequency set within the DataLINK or DataLOG to avoid anti aliasing acc ording to the Nyquist Sampling Theorem. Model no. Bandwidth Recommended Sampling Frequency per channel of DataLINK or DataLOG ACL300 DC to 100 Hz 200 Hz

DC to 500 Hz 1000 Hz DC to 1000 Hz 2500 Hz S3-1000G-HA DC to 1250 Hz 2500 Hz DC to 2500 Hz 5000 Hz DC to 5000 Hz 10000 Hz 11 SPECIFICATIONS Dynamometer G100 SPECIFICATIONS Pinchmeter P100 Dimensions standard Jamar configuration Mass 630 g Accuracy better than 1% RL Rated Load (RL) 0 to 90 Kg or 0 to 200 lb Cable Direct connection to DataLOG, DataLINK and K800 using cable type no. H1800 Calibrated and designed to work in compression only. Dimensions diameter 45 X 6 mm Mass 65 g Accuracy better than 0.6% RL Rated Load (RL) 0 to 22.5 Kg or 0 to 50 lb Cable Direct connection to DataLOG, DataLINK and K800 using cable type no. H1800 Calibrated and designed to work in compression only. 12

K800 Amplifier System A modern microprocessor controlled general purpose amplifier system which is designed to be worn by the subject. The K800 provides a user friendly method for collecting signals from a variety of sensors including goniometers, sEMG and related signals, in a format which may readily be connected to proprietary display and recording systems including A/D cards. Easy to use general purpose precision amplifier 8 analogue 5 digital channels +5V built in power supply Accepts all Biometrics Ltd sensors Accepts other sensors including load cells Real time display for all channels in engineering units RS422 digital data transfer from Subject Unit to Base Unit The K800 is a precision amplifier designed to provide the researcher with complete ease of use. Any combination of sensors may be connected to the small Subject Unit which is connected using a 6m cable to the larger Base Unit. All Biometrics Ltd sensors are easily connected with the analogue output voltages standardised in the range +0 to +4 Vdc. The LCD and 2 button switches act as the interface to configure the individual channels for the type of sensor attached. This enables any combination of sensors to be attached. The analogue output is via a single cable allowing interface to a wide range of analogue data recording systems. The sensors are categorised into 2 groups: Differential output bridge type sensors including: Biometrics Goniometers, Torsiometers, Hand Dynamometer, Pinchmeter Single ended high level sensors including: Biometrics sEMG pre amplifier, 3 axis accelerometers SPECIFICATIONS Model K800 MECHANICAL Subject Unit Base Unit Dimensions 100 x 50 x 25mm 180 x 170 x 48mm

Mass 150g 550g ELECTRICAL analogue channels 8 digital channels 5 Subject Unit microprocessor controlled Base Unit microprocessor controlled Communication from Subject unit to Base unit via RS422 Examples of other differential type sensors include strain gauge based devices such as load cells and certain flow meters. A differential bridge type sensor may be connected providing it can be powered by +5 Vdc and the output is in the range of +/- 12 mV. Examples of other single ended high level sensors include potentiometers. A single ended high level sensor may be connected providing it can be powered by +5 Vdc and the output is in the range of +/- 3.5 V. For all 8 analogue channels the K800 recognises automatically whether a differential bridge type sensor or single ended high level sensor is connected. The K800 also has 5 digital channel inputs which are used for contact switches and event markers. K800 Amplifier Accessories Event Marker IS3 A 1.8 metre cable with a suitable connector at one end to connect to the K800 Subject Unit, and a hand held switch on the other. This useful accessory allows time marks to be added to the data and enables the operator to highlight specific events during data collection. Contact Switch assembly FS4 An assembly of 4 Force Sensing Resistor Sensors (FSRs) each on 1.2 meters of cable which are readily connected to the K800 Subject Unit using one connector for use as switches to indicate contact e.g. heel and toe strike or palmer contact. The sensors are thin and robust and are usually placed inside the subject s shoe or glove for convenience. General analogue channels may be single ended high level or differential bridge type dependent on front end plug wiring configuration. Input voltage differential bridge mode +/- 12mV Input voltage single ended high level mode +/- 3.5V Output (full scale) Analogue +0.0 to +4.0 V Analogue channel input impedance 1M Ohm Power supply per channel + 5.0 V dc Power supply per channel tolerance 1 %. Accuracy better than 0.5 % full scale. Maximum Common Mode +3.5v to -2.5v. Bandwidth General 5 KHz 14 ADU301 Angle Display Unit

Two Channel Static Display / Two Channel Amplifier for Dynamic Data Transfer The ADU301 is a hand held two channel display unit providing quick and simple readings of joint angle data. Any Biometrics Goniometer or Torsiometer may be connected to the ADU301 using one or two of the J series cables. No calibration is necessary. The joint to be measured is placed in the neutral position and the zero key is pressed to zero both the LCD (liquid crystal display) and the analogue output. Static angles are displayed on the LCD. An analogue DC voltage proportional to the joint angle is obtained by connecting the ADU301 to the Output Isolation Unit R3000. This small interface unit contains full electrical isolation circuitry for compliance with the Medical Device Directive 93/42/EEC and comes complete with a mains power supply and cord. Although only one channel may be displayed at a time using the LCD, the dynamic output is continuous for both channels. The Clinical Systems are basic packages of instrumentation and sensors for simple static joint angle readout. The CS100 standard system comes complete with the ADU301, a twin axis goniometer (choice of size), interconnecting leads to connect the goniometer to the ADU301 unit. Packed in a sturdy instrument case. An alternative, the CS100X system, is also available and contains two For dynamic collection of movement data, the R3000, Output Isolation Unit with mains power supply, connects the Clinical System to, for example, an A/D card in your computer for 2 channel simultaneous and continuous data collection for analysis at a later date. (The A/D card is NOT supplied). This system does not have memory capability. SPECIFICATIONS ADU301 Angle Display Unit No. of channels (selectable) 2 Overall dimensions (mm) 100x60x25 Weight (g) including battery 180 Battery type MN1604 (alkaline) Analogue output resolution infinite LCD display resolution 1 Analogue output +0.5Vdc -180

(using Output Isolation Unit) +2.5Vdc +0 +4.5 Vdc +180 sizes of goniometers as well as a Q110 or Q150 torsiometer. Portable Systems Laboratory Systems The Laboratory Systems package the DataLINK with the most often requested Biometrics sensors in either basic or enhanced configurations. The LS800 Goniometer System comes with the DataLINK, Management & Analysis software, 6 goniometers (choice of sizes to accommodate upper & lower extremity), the IS2 event marker and the FS4 contact switch assembly. The LS800 Goniometer System is dedicated to portable EMG measurements and comes with the DataLINK, Management & Analysis software, 8 active EMG sensors, R206 earthing strap, T350 adhesive tape and IS2-LED event marker. The LS900 Goniometer & EMG System combines movement analysis with surface EMG measurements in a complete east to use, affordable system and comes with the DataLINK, Management & Analysis software, 6 goniometers (choice of sizes to accommodate upper & lower extremity), 1 Torsiometer, 4 active EMG sensors, R206 earthing strap, T350 adhesive tape, IS2-LED event marker and FS4 contact switch Assembly. Deluxe Data Acquisition System The Portable Systems are comprehensive packages of sensors and instrumentation for static and dynamic measurements in clinical settings, research centres, or any remote location such as a workplace. The PS800 Goniometer System comes with the DataLOG, Management & Analysis software, 6 goniometers (choice of sizes to accommodate upper & lower extremity), the IS3 event marker and the FS4 contact switch assembly. The PS850 EMG System is dedicated to EMG measurements and comes with the DataLOG, Management & Analysis software, 8 active EMG sensors, R206 earthing strap, T350 adhesive tape and IS3 event marker. The PS900 Goniometer & EMG System combines movement analysis with surface EMG measurements in a complete east to use, affordable system and comes with the DataLOG, Management & Analysis software, 8 goniometers (choice of sizes to accommodate upper & lower extremity), 8 active EMG sensors, R206 earthing strap, T350 adhesive tape, IS3 event marker and FS4 contact switch assembly.

The DS3000 Deluxe Data Acquisition System is designed to provide maximum versati lity in any setting. This combination of sensors and instrumentation provides the advantage of true portability using the DataLOG, yet also real time display & analysis using the DataLINK. Ideal for research facilities and educational establishments - multiple instruments allow concurrent data acquisit ion by multiple users. The Analysis Software reads files collected by both the DataLOG and/or the DataLINK. The DS3000 includes: DataLOG and DataLINK, both with Management & Analysis softw are, 8 active EMG sensors, R206 earthing strap, T350 adhesive tape, 9 goniometers (choice of standard sizes), 1 torsiometer, IS2 LED & IS3 even t markers, FS4 contact switch assembly. 13

PRODUCTS ARE COVERED BY THE MANUFACTURER S 12 MONTH WARRANTY. All systems covered by this brochure have been independently certified as meeting the requirements of European Medical Safety Standard EN60601-1, and conform to the European Medical Device Directive 93/42/EEC. Biometrics Ltd maintains to the highest standard a Quality Management System that is accredited to both ISO9001:2000 and ISO13485:2003. ISO9001:2000 ISO13485:2003 Certificate no. GB/05/66472 Certificate no. GB/05/66471 Biometrics Ltd Units 25 26 Nine Mile Point Ind Est Cwmfelinfach Gwent NP11 7HZ UK Tel: +44 1495 200 800 Fax: +44 1495 200 806 P.O. Box 340 Ladysmith VA 22501 USA North American Toll Free: 800 543 6698 Tel: 804 448 2520 Fax: 804 448 0021 E-mail: sales@biometricsltd.com Web Site: www.biometricsltd.com Unique Solutions for Clinical and Research Applications

You might also like