You are on page 1of 2
— ETERNITY Your Health, Our Future Featurs # LCD color touch screen © Humanized design and streamline appearance, more convenient for using ‘Three work modes: rate mode, time mode, and weight mode ‘¢ Multiple syringe brands inside and automatic identification syringe specifications Customizable calibration function * Rechargeable Li-ion battery, battery backup for at least 4 hours © Anti-Bolus function © sound and light alarm © Real-time display cumulative syringe volume can take easier clinical observation Night mode function * Can store 500 parameter alarm events Cc € ‘© Can work with other syringe pump in the meantime 0123 - STUUR 7010 SP300/SP400 Parameter of Syringe Pump et ETERNITY Your Health, Our Future '5P300_( Single Channel Syringe Pump > ‘5P400 ( Double Channel Syringe Pump ) Voltage: AC220V; Frequency: SOH2; Power Input: 30VA Voltage: AC220V; Frequency: SOH2: Power Input: 30VA Duration of Battery: Rechargeable L-ion battery, after full charge, can be used forthe syringe pump continuous running at Smi/h speed for 4 hours Rechargeable Lon battery, after ull charge, ‘can be used for the syringe pump contin uous running at Sih speed for 2 hours. ‘Operating noise: 5008) 5008 (Overall dimensions (IXwh) | 314mmX 146mm 126mm 328mm>150mm™ 242mm Weight: 25Kg 35Ke ‘syringe mode rates times body weight rate. time. body weight ‘10mi Syringe + Omi/h~300mI/hs 410ml Syringe + Omi/h~300mI/hs 20mI Syringe + Oml/h~400ml/h; 20ml Syringe + Oml/h~400mI/h: Syringe rate range 30m! Syringe + Omi/h~600mI/h 30mI Syringe + Omi/h~600mI/h 50m! Syringe + Omi/h~1200mI/h. minimum stepping set: O-1mi/n= 50ml Syringe + Oml/h~1200mi/h. minimum stepping set: O.1mV/n. Syringe accuracy error LIK E 2%. Preset volume range ‘OmI~999.0mt, ‘minimum stepping set: O.1m(/n ‘Omi ~999.0mL. minimum stepping set: O.1mV/n Rapid bolus rate ‘Omi Syringe + 300mi/ 20mi Syringe = 400m\/h; 30ml Syringe + 600m\/hs Omi Syringe + 1200mI/n. 410ml Syringe + 300m) 20mI Syringe = 400mi/n; 30mI Syringe + 600mI/n; SmI Syringe + 1200miI/n. Setting ratez 100 mifh, KVO rate is S mi/h. Setting rate> 100mi/h, KVO rate is mifh. kvo rate Setting rate> 1 ml/h and <100mi/h, KVO | Setting rate > 1mi/hand <100mV/n, KVO rate is1 ml/h rates 1 ml/h. Setting ate<1 ml/h» KVO rate setofficlosed). | Setting rate<1 mi/hy_KVO rate set officosed) Block sal high: 1003-35kPa; mid: 60:E22kPa: high: 100-£35kPa; mid: 60-E22kPa: low: 40:t15kPas low: 40: 15kPa: ‘Automatic identification of | yes ves syringe specifications Preset volume is near completion. {Preset volume is near completion alarm Preset volume completion ala 2Preset volume completion alarm: Syringe near empty alarm; 3.Syringe near empty alarm; Block alarm; 4.Block alarm; Syringe release alarm; S.Syringe release alarm; Alarms Fault alarm( Motor fast / slow, Motor reverse, | 6.Faultalarm(Motor fas / slow, Motor reverse, Battery off alarm); Battery off alarm); Forgetting alarm; ‘7 Forgetting alarm; Power interruption alarm; ‘Power interruption alarm; Battery undervoltage alar ‘9.Battery undervoltage alarm; Battery run outalarm 10,8attery run out alarm Hint KVO. Anti-Bolus. rapid liquid discharge KVO. Ant-Bolus. rapid liquid discharge Other [Night mode. touch screen [Night mode, touch screen TIN Tara oh eel eo) cerebro ot ent] Bite eet ia Eatery un High Eaeinoer eon ae en) (€Y2047-01 Data subject to change without notice

You might also like