GENERAL NOTES FOR RETAINING WALLS IN M20 CONC 1, ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED. 2. ONLY WRITTEN DIMENSIONS ARE TO BE FOLLOWED. 3. TOR STEEL TO CONFORM TO I:S 1786 OF 1985 FY STRENGTH 500 N/mm2. 4 LAPS IN BARS TO CONFORM TO IS 456 — 2000 5. CLEAR COVER TO ALL MEMBERS SHALL BE 50mm & 75mm FOR FOUNDATION 6. CONC. GRADE: ALL RCC WORK IN M20 & PCC M10 7... THE FILLING BEHIND WALL SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF CL 714.3 OF LR.C. 78 — 1983. 8. R-WALLS DESIGNED FOR LENGTHS OF 1.00 MTR ONLY HOWEVER LENGHTS CAN BE EXTENDED / INCREASED UP TO 40.00 MTRS 9, SEISMIC ZONE IV. 10. AGGREGATE SIZE 20mm & DOWN GUAGE. 11. SAFE BEARING CAPACITY OF SOIL — 10.00 t/sqm. 12. NALLAH BED SLOPE BE UNIFORMLY BE MAINTAINED AS 1.00 MTRS IN 200.00 MTRS ( i.e.0.005 ) 13. ADEQUATE TRASHES AT RREQUISITE LOCATIONS HAVE TO BE PROVIDED LOCATIONS TO BE DECIDED BY THE EXECUTING AGENCY. 14. VERTICAL WALL THICKNESS = 300mms BASE SLAB THICKNESS = 400mms BASE CUSHION THICKNESS = 150mms ho designdotas and idoas ontsined in thadrawang are roperyot MIS OP SHARMA "ASSOCIATES (ongnears nd etructral consultant) [No part thar of shall be for any ther work or project vite cosent of ma 8 Associates EXECUTION 02 CONSTRUCTION oF IALLAH PASSING ALONG ;REMATION GROUND SHASTRI NAGAR |AMMUWARD NO 22 INDER JAMMU SMART TY LIMITED ‘Superentending Engineor SEWERAGE and DRAINAGE “GENERAL NOTES FOR (CHANNEL CONSTRUCTION Drawn by: SUNIL sos no - 2209606 OPSASTR. 2209-STR- (A)