Diplomat Optimum
The hot water tank is fitted with our TWS* technique, which means
that the hot water is produced faster and at higher temperatures
than with traditional technique.
The pump utilises rock, surface ground, ground water or lake water
as its heat sources.
A++
A++
A++ energy class when the heat pump is part of an integrated system
A++ energy class when the heat pump is the sole heat generator
Energy class according to Eco-design Directive 811/2013
R E TA I L E R :
Thermia Heat Pumps reserves the right to make changes without further notice. 131018_DO_DDO_ENG
Auxiliary heater, 3 steps kW 3/6/9 3/6/9 3/6/9 3/6/9 3/6/9 3/6/9
Start current 1 A 15 9 10 12 14 20
Fuse A 169/104/105/166 104/165/206 164/165/206 164/165/206 164/205/256 204/205/256
Electrical data Main supply Volt 230 230 230 230 230 ***
1-N, ~50Hz Rated power, compressor kW 2.3 3.2 4.1 4.5 5.5 ***
Rated power, circulation pumps kW 0.1 0.1 0.1 0.3 0.3 ***
Auxiliary heater, 3 steps kW 1.5/3/4.5 1.5/3/4.5 1.5/3/4.5 1.5/3/4.5 1.5/3/4.5 ***
Start current 1 A 15 22 24 26 28 ***
Fuse A 204/255/326 254/325/406 324/405/506 324/405/506 324/405/506 ***
Performance COP 2 4.57 4.74 4.88 4.84 4.75 4.80
COP 3 4.09 4.04 4.34 4.24 4.20 4.19
Heating capacity 3 kW 4.09 5.33 7.51 9.40 11.0 16.8
Electrical power 3 kW 1.0 1.3 1.7 2.2 2.6 4.0
10
Energy class - system Floor heating (35°C)/Radiator (55°C) A++/A+ A++/A+ A++/A++ A++/A++ A+++/A++ A++/A++
11
Energy class - product Floor heating (35°C)/Radiator (55°C) A++/A+ A++/A+ A++/A++ A++/A++ A++/A++ A++/A++
Domestic hot water A A A A A A
Max/min temperature Cooling circuit °C 20/-10 20/-10 20/-10 20/-10 20/-10 20/-10
Heating circuit °C 60/20 60/20 60/20 60/20 60/20 60/20
Anti freeze media Ethanol + water solution with freezing point-17 ±2 °C 8
The measurements are performed on a limited number of heat pumps which 1) According to IEC61000. 10) When the heat pump is part of an integrated system.
can cause variations in the results. Tolerances in the measuring methods can 2) At B0W35 ∆10K warm side (excluding circulation pumps). According to Eco-design Directive 811/2013
also cause variations. 3) At B0W35 according to EN 14511 (including circulation pumps). 11) When the heat pump is the sole heat generator and the built-in controller is not
4) Heat pump with 3 kW auxiliary heater (1-N 1.5 kW). included. According to Eco-design Directive 811/2013.
* TWS = Patented heating technique for water heaters, developed by Thermia. 5) Heat pump with 6 kW auxiliary heater (1-N 3 kW). 12) The refrigerant circuit is hermetically sealed and subject to the F-gas directive.
**) Only Diplomat Duo Optimum. 6) Heat pump with 9 kW auxiliary heater (1-N 4.5 kW). Global Warming Potential (GWP) for R407C according to EC 517/2014 is 1774,
***) Not available in this version. 7) Sound power level measured according to EN ISO 3741 at BOW45 (EN 12102). giving a CO2 equivalent corresponding to 4: 1331 kg, 6: 2129kg, 8: 2395,
8) Always check local rules and regulations before using antifreeze. 10: 2572kg, 12: 2750kg, 16: 3548kg.
9) Fuse phase L1 (size 4 has 1-phase compressor).
Thermia Heat Pumps | Box 950 | SE- 671 29 Arvika | Tel. + 46 570 813 00 www.thermia.com