You are on page 1of 2
MEASUREMENT ‘Clotting | Viscosity Based (Mechanical) clot detection Chromogenic | by measurement of optical density (@t 405 nm) Immunology | by measurement ‘of optical density (et 540 nm) METHODOLOGIES 200 user definable tests for clotting, chromogenic and immunological assays PARAMETERS, Pr Arr Fibrinogen Thrombin Time Extrinsic pathway factors Intrinsic pathway factors ‘AntiXa (UFH, LMWH, Rivaroxaban..) Antilla -Dimers, Fibrin Monomers and Fibrin Degradation Products| Antithrombin Protein C Activated Protein C Resistance Protein S Lupus Anticoagulant We Microparticles Plasminogen, Antiplesmin and TAFI Calibrators Quality Controls SAMPLES. 215 sample tubes on board 5 position rack Tray with 15 racks/75 sarnpes STAT position Main tube sizes accepted including paediatrics ‘& micracontainers Continuous loading and unloading cof sample racks Cap piercing option Positive barcode identification ‘Automatic pre-diution and dition ‘of samples For further information, please contact: REAGENTS 0 positions for diferent sized vials (45 string postions) Rendom loading of reagents Positive barcode identification Temperature controlled Precaliration fr lots of reagents ‘Automatic pre-dilution of callrators ‘Automatic Quality Contr DISPOSABLE Roll of 1000 optical quality cuvettes with stainless ste! bal Unitary reaction cuvete (cuvette 1 test), FLUIDICS ‘Woshing solution on bosrd Connectable to 3 biological eluent treatment station HARDWARE* Processor | Intel Celeron M. 1.06 GHe Mernony| 10 een ard Disk | 160.6 nina Operating system | Windows Embedded | Standard 2009" Sereen Touch CD colour screen 22" Keyboard | Alphanumeric QWERTY or AZERTY type Storage | DVD+/-RW burner 4 USB ports minimum, CONNECTION "Network | RJ45 port (Ethernet 10/100Mbps) US 85282 | port Mono or Bidirectional (ASTM Protocol) DIMENSIONS Height | 1265 min (4938 in) ‘adi | 1220 mm (48.0 in) Depth | 805 mm (31.6 m) Weight | 238 hg (524.7 b) SPACE REQUIRED Height | 1875 min (73.8 in) ‘width | 2940 mm (115.7 in) Depth | 1300 mm (1.1 in) POWER SUPPLY Voltage and | 230V (108i), tolerances | 120V (10%) Frequency and | 50/60 Hz tolerance | (47 Hz to 63 He) Peak powers | 1.3 kW {Hor 230V/120) ROOM ENVIRONMENT Operating Room | 15°C 10 32°C temperature | (59°F 0 90°F) felaive uni | Between 20 and 80% without condensation ‘Average Thermal | 230.V ode Cuipat at ambient | 6824 BTU temperature of 20°C | 115 V model | 6147 BTUMh ‘Averoue Noise | 52 dB wile ‘Output operating Stago reserves the possi ody ths hardware by anys Har of sar Widows bedded Standd 2009 frank rc ros Corporation Digna Sago SA. {Snore BES 151409 ee et Sacto Arares Ssine 4

You might also like