DYNEX High Pressure Hydraulics

ENGINEERING
SPECIFICATIONS

D03 SERIES
8 gpm (30 L/min) Nominal
D03 Directional 15 gpm (57 L/min) Max
Control Valves 5 000 psi (350 bar) Rated Pressure
D03 valves operate at high pressure
and offer high flow capability in a very
compact size. Flows to 15 U.S. gpm
(57 L/min) are possible at pressures to
5000 psi (350 bar).
These are very efficient valves featuring
large flow passages for low pressure drop.
Typical pressure drop (open center
spool) is a low 98 psi at 8 U.S. gpm
(7 bar at 30 L/min) nominal flow.
Refer to pages 2 and 3 for a description
of spools and operators.

Mounting
Subplate, NFPA D03, NG6, ISO 4401-03.

Actuator Options
6100 Series: Manual Lever.
6500 Series: Direct Solenoid.
6800 Series: Hydraulic Piloted.
6900 Series: Air Piloted.

Rated Flow Table of Contents


Nominal: 8 U.S. gpm (30 L/min). All Models Internal Operators Page 2
Maximum: 15 U.S. gpm (57 L/min).
All Models Spool Descriptions Page 3
Rated Pressure All Models Mounting Page 3

5000 psi (350 bar). All Models Performance Page 4


6100 Series Manual Lever Operated Page 5
Tank Port Pressure (Maximum)
6500 Series Solenoid Actuated Page 5
Manual Actuated Models:
6800 Series Hydraulic Actuated Page 8
3000 psi (210 bar).
6900 Series Air Actuated Page 8
Solenoid Actuated Models:
Standard, 3000 psi (210 bar). All Models Model Code Page 9
Hydraulic and Air Actuated Models:
1500 psi (105 bar).

Response Time (Full Stroke)


Solenoid Energized:
AC, 12 ms; DC, 20 ms.
Spring Returned:
AC, 15 ms; DC, 20 ms.
INTERNAL OPERATORS Valve Operator Descriptions
The Valve Operator table shows Internal Operator Functions
available internal operators and the Operator Actuator,
most common spools. Refer to Typical Code Operation Spool Types Non-Actuated Actuated Function Symbol
Model Code on page 9 to specify A B

specific valve model. 0 or 1 P→B P→A


Lever + Single P T
A

Contact the Dynex Sales department for 1 Actuator, A B

availability of spool options not shown. Two Position


03 P→B P→A A

The function symbols in the table show P T

solenoid or lever actuated models as A B

0 or 1 P→A P→B
reference. Air and hydraulic actuators Lever + Single B
P T
are also available. 2 Actuator,
A B
Two Position
Flow pattern in the center position 03 P→A P→B B

or during crossover is determined P T

by the selected spool. Refer to Spool Detented in P→A A B

0 or 1 Actuated or
Descriptions on page 3. Double Positions P→B
B
P T
A

Actuator,
Detented in P→A A B

Flow Patterns 3
Two Position
03 Actuated or B A

Actuator “A” opens flow path (P→A). Positions P→B P T

Actuator “B” opens flow path (P→B). Lever Actuator, All


Detented in P→A A B

Actuated or
The exception are models with Code 6 Three Position Spools
Positions P→B P T
internal operators, which are centered A B
when actuated. Spring
03 P→A
Centered A

Spring-centered and spring-offset models P T

are spring-positioned unless actuated. 03 Spring


A B

P→B
Reverse Centered B

Detented Models (Solenoid Operated) A B


P T

Spring
Code 3 operators (two position 011 P→B
Single Actuator, Centered B

detented) hold the spool in the last 4


Two Position
P T
A B
actuated position. These valves can 011 Spring
P→A
be actuated momentarily (minimum Reverse Centered A
P T

electrical signal duration, 50 ms) to shift Spring


A B

and hold the spool in that position. 0, 1, 3 P→A


Centered P T
A

A B
“R” Option 0, 1, 3 Spring
P→B
Reverse Centered B
(Internal Operator Codes 4 & 6 Only) P T

Lever + Double P→A A B


Flow pattern can be altered with “R” 5 Actuator,
All Spring or
(Reverse Assembly) option. Refer to Spools Centered B A
Three Position P→B P T

Valve Operator Descriptions table for A B

flow pattern details. 03 P→B Centered A


P T

A B
03
P→A Centered
Reverse B

APPLICATION NOTES A B
P T

Single 011 P→A Centered


Standard Seals 6 Actuator, P T
B

All valves use Fluorocarbon (Viton®,


A B
Two Position 011
P→B Centered
Fluorel®, or equivalent) o-rings, providing Reverse A
P T

greater fluid compatibility and increased A B

temperature range performance. 0, 1, 3 P→B Centered A


P T

Fluid Recommendations 0, 1, 3
P→A Centered
A B

Reverse B

50 to 1500 SUS (7 to 323 cSt) viscosity; P T

-20° to 200° F (-29° to 93° C) Detented in P→A A B


Lever Operated, or
temperature range. 7 0 or 1 Actuated
Two Position
Positions P→B P T

Recommended Filtration  A & B represent the actuator(s), which can be Air, Hydraulic, or Solenoid.

Use filtration to provide fluid which


meets these ISO Code 4406 cleanliness
values: 19/17/14.

2
Spool Descriptions
Spool Types Spool Symbol Crossover Function Description of Spool Function
A B A B

0, (20) B A
Closed center spool. All ports blocked in center position.
P T P T
A B A B
Open center spool. All ports connected in center position. Allows fluid motors or
1, (21) B A cylinders to move when de-energized. Minimum shock during crossover.
P T P T
A B A B

3 B A
Pressure port blocked in center position. Both A and B ports connected to tank.
P T P T
A B A B
A and B ports pressurized in center position, tank port blocked. Used for a differential
4 B A
circuit with single rod cylinder. Prevents motor cavitating when decelerating. Reduces
P T P T
crossover shock.
A B A B

011 A B
Tandem center spool, as noted for Type 01 and 56 spools, but with open crossover.
P T P T
A B A B
Open center spool with port B blocked and port A open to pressure and tank in the
2 A B center position.
P T P T
A B A B
Open center spool with port A blocked and port B open to pressure and tank in the
2R A B center position.
P T P T
A B A B

32 B A
Pressure port blocked with port A blocked, port B connected to tank in center position.
P T P T
A B A B

32R B A
Pressure port blocked with port B blocked, port A connected to tank in center position.
P T P T
A B A B

36 Pressure port blocked in center position. A and B ports partially restricted and
B A
connected to tank.
P T P T
A B A B
Closed center spool. All ports blocked in the center position.
03 B A Tank port blocked in all positions.
P T P T

 A & B represent the actuator(s), which can be Air, Hydraulic, or Solenoid.


 Code 1 or 2 operators with Explosion Proof solenoids (120EP or 24EP only) use Type 20 or Type 21 spools. These spools provide the same function, but are not
interchangeable with Type 0 or Type 1 spools.

2.00
(50,8)
VALVE MOUNTING ∅.16 (4,1) 1.594
.16 (4,1) DEEP MINIMUM (40,49)
Valves can be mounted without LOCATING PIN HOLE 1.30 .19
removing nameplate. Mounting position (33,0) (4,8)
is unrestricted for all valves.
P
The mounting surface drawing shows the
minimum flush or raised surface required 1.22
for the NFPA D03, NG6, ISO 4401-03. 1.70
B A (30,99)
1.02 1.25
(43,2)
Port o-rings are included with all valves. .20 (25,9) (31,75)
(5,1) .61
Mounting bolts must be ordered 32 (15,5)
(0,80) T
separately: 10-24 UNC Threaded x 0.75
inch (19, 0), Grade 8 or better, four .0004/4.0
(0,010/102)
.03
required. Recommended mounting .50 (0,76)
(12,7) .25
torque is 65 lb-in (7,3 N•m). ∅.250 (6,35), 4 PORTS .85 (6,4)
(21,6)
Note: Installation drawing dimensions 1.19 NO. 10-24 UNC–2B THREADED
are shown in inches (millimeters in (30,2) .37 (9,4) DEEP, 4 MOUNTING HOLES
parentheses) and are nominal.
Minimum Mounting Surface

3
VALVE EFFICIENCY Pressure Drop (∆P) Curves
D03 valves provide exceptionally
low pressure drop, as shown in the
performance curves.

Determining Pressure Drop


The Pressure Drop (∆P) Curves show

bar
psi
typical resistance to flow for various
spool types. The Flow Curve Reference
table identifies the typical pressure drop
curve for desired spool and flow path.
If the valve has simultaneous flow
through it in more than one direction,
then the “Loop” pressure drop should be
determined to estimate total pressure
drop (∆P) through the valve.
To determine total “Loop” drop, the gpm L /min
individual pressure drops for both flow
paths (for example: P→A + B→T) must be  Curves are based on the use of 100 SUS (20 cSt) petroleum-based fluid at 120° F (50° C).
added together.
Flow Curve Reference
Spool Types
Flow
Path 0 20 1 21 3 4 011 2 2R 32 32R 36 03
P→A B B C D B C C C C B B B B
P→B B B C D B C C C C B B B B
A→T E E F F F E C C C E F G –
B→T E E F F F E C C C F E G –
P→T – – D D – – A A A – – – –
 See Spool Descriptions and Symbols on page 3 to determine which spool to select for valve application.

Typical Pressure Drop (∆P Example)

To determine the pressure drop (ΔP) for Spool Type “0”


From Flow Curve Reference table, cross reference:
Spool Type “0” with the Flow Path for P→A or P→B functions = (B curve)
Spool Type “0” with the Flow Path for A→T or B→T functions = (E curve)
From Pressure Drop (ΔP) Curves:
At 8 gpm: (B curve) = approx. 60 psi (P→A)
At 8 gpm: (E curve) = approx. 40 psi (B→T)

To determine total (for example: P→A + B→T):


Loop Pressure Drop = 60 psi + 40 psi = 100 psi

4
6100 SERIES MANUAL LEVER
OPERATED MODELS FULLY ACTUATED FULLY ACTUATED
HANDLE POSITION FOR P→A HANDLE POSITION FOR HANDLE POSITION FOR P→ B
CENTER FLOW FUNCTIONS 14.5° 14.5° FOR TYPE 0, 1, 3, 4, 03, 32,
FOR TYPE 0, 1, 3, 4, 03, 32
32R, 36 SPOOLS; P→B 32R, 36 SPOOLS; P→ A FOR
Manual models feature a hand lever that FOR TYPE 011, 2, 2R SPOOLS TYPE 011, 2, 2R SPOOLS
can be configured on either end of valve.
To specify lever orientation, refer to
Typical Model Code on page 9.
HANDLE POSITION
Most manual models are rated for FOR P→ B FOR
TYPE 0, 1, 3, 4, 03,
15 U.S. gpm (57 L/min) maximum. The 32, 32R, 36 SPOOLS;
P→ A FOR TYPE 6.00
exception is model 613011-D03 which 011, 2, 2R SPOOLS (152,4)
is rated for 13 U.S. gpm (49 L/min)
maximum. This model has a Code 3 2.34
(59,5)
internal operator (3 position, detented
2.49 .38 1.88
operation) with Type 011 spool (63,2) 1.38 (9,7) (47,8)
(35,1) GRIP
(tandem center).
.13 .52
Weight (Mass) ∅.125
(3,18)
LOCATING PIN 1.594
(3,2) (13,2)
.61
.27
(6,9)
1.250
(31,75)
(40,49) (15,5) 1.79
3.2 lb (1,5 kg). .92
(23,4)
(45,5)
.52 3.53 1.19 NO.10-24 UNC THREADED x
(13,2) (89,7) (30,1)
5.24 .75 (19,0) LONG MOUNTING BOLTS,
(133) 4 REQUIRED; TORQUE: 65 LB - IN (7,3 N•m)
5.89
(149,7)

6100 Series, Manual Lever Operated

6500 SERIES SOLENOID MODELS Flow Capacity Curves – Solenoid Models


Valve Flow Capacity 6000
400
Flow capacity depends on valve
actuator, internal operator and spool 5000 A 350

type. Refer to Typical Model Code on E


PRESSURE (psi)

300

PRESSURE (bar)
4000
page 9. B C D 250
3000
Curves show typical performance for 200

each spool type. The letters in the Flow 2000 150

Curve Reference table identify the 100


1000
appropriate curve. 50

0 0
0 2 4 6 8 10 12 14 16
0 10 20 30 40 50 60
FLOW (U.S. gpm - L/min)

 Curves are based on the use of 100 SUS (20 cSt) petroleum-based fluid at 120° F (50° C).

Flow Curve Reference


Spool Types
0 1 3 4 011 2 2R 32 32R 36 03
A A A A B E E C C D A

5
SOLENOID OPTIONS Solenoid Electrical Data
Models are available with standard AC Coil Resistance (Ohms)
or DC solenoids. Solenoid Types Volts Frequency (Hz) at 77º F (25º C) Power (Watts)
24AC 60 19.4 - 21.4 23
Electrical Connections AC Standard 115AC 60 444 - 492 23

Plug-In-Terminal Solenoids fit Deutsch 230AC 60 1823 - 1941 23
DT04-2P Connector or EN175301-803 / DC Standard
12DC – 4.56 - 5.04 30
DIN 43650 Form A (Hirschmann Type) 24DC – 18.24 - 20.16 30
Connector. 120AC 60 830.4 - 900.0 13
Explosion Proof
24DC – 44.3 - 46.1 13
Standard Solenoids  Information shown is for 60Hz models only. At other frequencies the coil characteristics must be revised.

Solenoids are easily removed without


manual wiring or opening the hydraulic
system for replacement. Coils can be ELECTRICAL CONNECTOR
1.55
(39,3)

rotated 360º for flexible installation. 1.55


(39,3)
TO FIT EN175301-803 / DIN 43650 FORM A
(HIRSCHMANN TYPE) CONNECTOR
1.05
(26,8) 2-PIN DEUTSCH
CONNECTOR
1.34
CSA/UL Recognized (34,1) 2.79
(70,8)
1.69
(42,9)

All Solenoid coils are printed with 1.80


(45,7) 1.65 1.67
(42,5)
the symbol: 1.33
(33,7)
(42)

(CSA and UL recognized component).


A.C. DIN CONNECTOR D.C. DIN CONNECTOR A.C. DEUTSCH CONNECTOR D.C. DEUTSCH CONNECTOR
COIL COIL COIL COIL

COIL RETAINING NUT


TORQUE: HAND TIGHT 1.55
(39,3)

Solenoid Model Dimensions 2.13 1.65


(54) (42)
∅1.78
Weight (Mass) (45,3)
2.34 2.49
(59,5) (63,2)
Single Solenoid: PUSH TO ACTIVATE 1.38
MANUAL OVERRIDE (35,1)
3.4 lb (1,5 kg).
SOLENOID TUBE
Double Solenoid: TORQUE TO 40 LB-FT
1.96
(49,8) .92
.13
(3,2) ∅.125
4.0 lb (1,8 kg). (54 N•m) ON TUBE FLATS 3.86
(98,1)
(23,4) (3,18)
(UNDERNEATH COIL) 3.53 .25
(89,7) (6,4)
7.39
(187,7)

6500 Series, Single Solenoid Models (A.C. DIN Connector Version Shown)

SOLENOID A FOR TYPE 0, 1, 3, 4, 03, 1.55 ELECTRICAL CONNECTOR TO FIT


32, 32R, 36 SPOOLS; (39,3) EN175301-803 / DIN 43650
1.15 SOLENOID B FOR TYPE 011, 2, 2R SPOOLS FORM A (HIRSCHMANN TYPE) CONNECTOR
(29,2)
SOLENOID B FOR TYPE 0, 1,
3, 4, 03, 32, 32R, 36 SPOOLS;
SOLENOID A FOR TYPE 011,
2, 2R SPOOLS
2.13 1.65
(54) (42)
2.49
(63,2)
2.34
.38 PUSH TO ACTIVATE (59,5)
(9,7) MANUAL OVERRIDE
GRIP SOLENOID TUBE
TORQUE TO 30 LB-FT 1.96
.27 (49,8) ∅.125 .13 .92 1.38
∅.125
1.79 (6,9) (41 N•m) ON TUBE FLATS (3,18) (3,2) (23,4) (35,1)
(3,18) (UNDERNEATH COIL)
LOCATING PIN (45,5) 3.86 3.53
(98,1) (89,7)
1.96 CLEARANCE TO 11.25
(49,8) REMOVE COIL (285,8)

6500 Series, Double Solenoid Models (A.C. DIN Connector Version Shown)

6
EXPLOSION PROOF Explosion Proof Solenoid Ratings
SOLENOID MODELS Governing
Location Standard Gas Ratings Dust Ratings
“EP” solenoids with Class I (Division 1) Group A, Class II & III (Division 1) Group
United States NEC 500
special enclosures B, C, D, T4 E, F, G, T4
are approved by UL Safety ratings in the US are governed under the National Electrical Code (NEC). There are two separate classification systems
and CSA for use in (NEC 500 and NEC 505). To ensure universal acceptance, MSA HAZ-LOC coils have been approved under both systems.

hazardous locations. United States NEC 505 Class I (Zone 1) AEx d IIC T4 Gb Class II (Zone 21) AEx tb IIIC T4 Db
Mandatory for Gulf of Mexico Class and Zone Rating. Most International markets require recognition under the
Conforms to ANSI/ISA STD 60079-31, UL International Electrotechnical Committee (IEC) Ex scheme.
STDS 1203, 50, 50E, 60079-0 & 60079-1. Canada CEC/CSA Ex d IIC T4 Gb (Zone 1) Ex tb IIIC T4 Db (Zone 21)
Certified to CAN/CSA STD C22.2 Nos. 30, Canadian safety ratings are regulated by the Canadian Electrical Code (CEC), closely following the US-NEC Standards.
25, 0.4, 0.5, 60079-0, 60079-1 & 60079-31. Similar to NEC 500, NEC 505 and ATEX Gas and Dust ratings.

II 2 G | EX d IIC T4 Gb II 2 D | EX tb IIIC T4 Db
Europe ATEX
(Zone 1) (Zone 21)
Similar to NEC 505 Gas and Dust ratings.

International IECEx Ex d IIC T4 Gb (Zone 1) Ex tb IIIC T4 Db (Zone 21)


Similar to ATEX Gas and Dust ratings.

 Consult Dynex Sales for Dust Rated solenoid availability.

Explosion Proof Solenoid Dimensions


Weight (Mass)
Single Solenoid: 8.3 lb (3,8 kg).
Double Solenoid: 14.0 lb (6,4 kg).

7.39 .25
.75 (187,7) (6,4)
(19)
HEX

3.02
(76,8)
2.79
(70,8)

2.36
(60)
CLEARANCE TO
REMOVE COIL
2.36
(60)

6500 Series, Single AC/DC “EP” Explosion Proof Solenoid Models

WIRE TAP 11.25


OPTIONAL SUPPORT (285,8)
BRACKET MOUNTING .75
LOCATION SUPPLEMENTAL (19)
5 MM THREAD GROUND SCREW HEX
.312 (8) HEX
2 MM COVER
.500-14 NPT ELECTRICAL
LOCK SCREW 3.02
CONNECTION
(76,8)
2.79
1.65 (70,8) 4.40
(42) (111,8)

PUSH TO ACTIVATE
MANUAL OVERRIDE
SOLENOID TUBE
TORQUE TO 2.36
2.00 (60)
30 LB-FT (41 N•m)
(50,8) ON TUBE FLATS COIL RETAINING NUT
(UNDERNEATH COIL) TORQUE: HAND TIGHT

6500 Series, Double AC/DC “EP” Explosion Proof Solenoid Models

7
6800 SERIES HYDRAULIC Minimum Pilot Pressure - Hydraulic Actuated Models
ACTUATED MODELS Pilot Pressure at:
The nominal flow capacity for most pilot 5 U.S. gpm (19 L/min) 8 U.S. gpm (30 L/min) 15 U.S. gpm (57 L/min)
operated valves is 15 U.S. gpm (57 L/min). Spool Types psi bar psi bar psi bar
Maximum flow for pilot operated valves 0 130 9,0 165 11,4 200 13,8
is dependent on pilot pressure. The table 1 150 10,3 165 11,4 420 29,0
shows the minimum pressure required to 3 145 10,0 165 11,4 180 12,4
shift the spool, for various flow capacities. 4 130 9,0 165 11,4 200 13,8
011, 2 or 2R 190 13,1 275 19,0 – –
Maximum Pilot Pressure 32 or 32R 150 10,3 200 13,8 – –
3000 psi (210 bar). 36 150 10,3 200 13,8 350 24,1
Required Volume (to shift spool full 03 130 9,0 165 11,4 200 13,8
stroke): 0.014 in3 (0,23 cm3).  The values listed are based on zero tank pressure. As tank back pressure increases above zero, more
pilot pressure may be required.
Hydraulic Actuated Dimensions  Higher flow rates may require an increased pilot pressure.

Overall length of single actuator PILOT A FOR TYPE 0, 1, 3, 4, 03, 32, 32R, 36 SPOOLS;
configuration (not shown) is PILOT B FOR TYPE 011, 2, 2R SPOOLS PILOT B FOR TYPE 0, 1, 3, 4,
5.25 inches (133,4 mm). 6.46
(164,1)
03, 32, 32R, 36, SPOOLS;
PILOT A FOR TYPE 011, 2, 2R SPOOLS
3.53 1.47
.88 (89,7) (37,3)
Weight (Mass) (22,4)
HEX
Single Actuator: 2.5 lb (1,1 kg).
2.49
Double Actuator: 2.8 lb (1,3 kg). .38
(63,2)
2.34
(9,7) (59,5)
GRIP
PILOT PORT (2)
.13 NO. 4 SAE
NO. 10-24 UNC THREADED x .27
.75 (19,0) LONG MOUNTING BOLTS, (3,2)
∅ .125 (3,18) 1.79 (9,6)
4 REQUIRED, TORQUE: 65 LB-IN (7,3 N•m) LOCATING PIN (45,5)

6800 Series, Double Hydraulic Piloted Models

6900 SERIES AIR Minimum Pilot Pressure - Air Actuated Models


ACTUATED MODELS Pilot Pressure at:
The nominal flow capacity for most pilot 5 U.S. gpm (19 L/min) 8 U.S. gpm (30 L/min) 15 U.S. gpm (57 L/min)
operated valves is 15 U.S. gpm (57 L/min). Spool Types psi bar psi bar psi bar
Maximum flow for pilot operated valves 0 25 1,7 28 1,9 33 2,3
is dependent on pilot pressure. The table 1 21 1,4 22 1,5 24 1,7
shows the minimum pressure required to 3 or 4 25 1,7 28 1,9 34 2,3
shift the spool, for various flow capacities. 011 23 1,6 40 2,8 – –
2 or 2R 23 1,6 40 2,8 – –
Maximum Pilot Pressure
32 or 32R 25 1,7 30 2,1 – –
200 psi (14 bar). 36 25 1,7 28 1,9 34 2,3
Required Volume (to shift spool full 03 25 1,7 28 1,9 33 2,3
stroke): 0.220 in3 (3,61 cm3).  The values listed are based on zero tank pressure. As tank back pressure increases above zero, more
pilot pressure may be required.
Air Actuated Dimensions  Higher flow rates may require an increased pilot pressure.

Overall length of single actuator


PILOT B FOR TYPE 0, 1, 3, 4,
configuration (not shown) is PILOT A FOR TYPE 0, 1, 3, 4, 03, 32, 32R, 36 SPOOLS;
PILOT B FOR TYPE 011, 2, 2R SPOOLS 03, 32, 32R, 36 SPOOLS;
5.56 inches (141,2 mm). 7.09
PILOT A FOR TYPE 011,
2, 2R SPOOLS
(180,1)
Weight (Mass) 3.53
(89,7)
1.78
(45,2) PILOT PORT (2) 1/8-27 NPT
Single Actuator: 2.3 lb (1,0 kg).
Double Actuator: 2.5 lb (1,1 kg).
2.49
(63,2)
.38 2.34
(9,7) (59,5)
GRIP
.13
NO. 10-24 UNC THREADED x (3,2) ∅ .125 (3,18) .27
.75 (19,0) LONG MOUNTING BOLTS, LOCATING PIN (6,9)
4 REQUIRED, TORQUE: 65 LB-IN (7,3 N•m) 1.79
.92 (45,5)
(23,4)

6900 Series, Double Air Piloted Models

8
TYPICAL MODEL CODE
6 1 1 0
– D03

115DA

R

A12 – E – 3 0

Valve Type Modification Number


Subplate Mounted
6
Directional Control
Design Number

Actuators
Seals
1 Lever Operated
No Code Fluorocarbon (Viton® or Fluorel®)
5 Solenoid Actuated
E EPR (Ethylene-Propylene Rubber)
8 Hydraulic Actuated
9 Air Actuated
Lever Position (Manual Models Only)
A12 12 o'clock positon, port "A" end
Internal Operators
A3 3 o'clock positon, port "A" end
Two Position: Spring Offset (P→B),
1 A6 6 o'clock positon, port "A" end
Actuated Position (P→A)
Two Position: Spring Offset (P→A), A9 9 o'clock positon, port "A" end
2
Actuated Position (P→B) B12 12 o'clock positon, port "B" end
Two Position: Detented; B3 3 o'clock positon, port "B" end
3
Three Position: Detented (Lever Operated Only)
B6 6 o'clock positon, port "B" end
Two Position: Spring Centered,
4 B9 9 o'clock positon, port "B" end
Actuated Position (P→A)➂
5 Three Position: Spring Centered
Two Position: Spring Offset (P→B), Reverse Assembly Option
6
Actuator Centered➃
Used with Internal Operators Codes 4 & 6 only.
7 Two Position: Detented (Lever Operated Only) R
Refer to Valve Operator Descriptions on page 2 for details.
 Only available with Type 0, 1, and 03 spools.
 Not available with Manual Lever valves.
➂ Spool Type 011 (tandem center) actuated Position P→B. Electrical Options
➃ Spool Type 011 (tandem center) spring offset P→A.
AC Solenoids Deutsch Connector:  DC Solenoids Deutsch Connector: 
115DA 115V/60Hz, 110V/50Hz 12DD 12VDC
Spool Types 230DA 230V/60Hz, 220/50Hz 24DD 24VDC
A B A B
24DA 24V/60Hz, 24V/50Hz
0, (20) 2
P T P T
AC Solenoids DIN Connector:  DC Solenoids DIN Connector: 
A B A B 115HA 115V/60Hz, 110V/50Hz 12HD 12VDC
1, (21) 2R 230HA 230V/60Hz, 220/50Hz 24HD 24VDC
P T P T
24HA 24V/60Hz, 24V/50Hz
A B A B
AC Explosion Proof:➂➃ DC Explosion Proof:➂➃
3 32
P T P T
120EP 120V/60Hz 24 EP 24VDC
A B A B  Fits Deutsch DT04-2P Connector.
 Fits EN175301-803 / DIN 43650 Form A (Hirschmann Type) Connector.
4 32R ➂ Junction box with 1/2 " NPT entry. Terminal strip connection.
P T P T
➃ Consult Dynex Sales for Dust Rated solenoid availability.
A B A B

011 36
P T P T
Valve Size
A B
D03 NFPA D03 (NG6, ISO 4401-03) Mounting Pattern
03
P T

 Code 1 or 2 operators with Explosion Proof solenoids (120EP


or 24EP only) use Type 20 or Type 21 spools. These spools
provide the same function, but are not interchangeable with
Type 0 or Type 1 spools.
 Not available with Type 3 Internal Operators (except Lever
Operated models).

9
Specifications shown were in effect when
printed. Since errors or omissions are possible,
contact your Sales representative or the Sales
department for the most current specifications
before ordering. Dynex reser ves the right
to discontinue products or change designs at
any time without incurring any obligation.

www.dynexhydraulics.com

USA Headquarters
USA Headquarters Power Units &Power Units & Systems
Systems European Sales European Sales
770 Capitol770 Capitol Drive
Drive 54 Nickerson Road
54 Nickerson Road Unit C5
Unit C5 Steel SteelLittle
Close, Close, EndLittle
Road,End Road,
Pewaukee, Pewaukee,
WI 53072 WI 53072 Ashland, MA 01721
Ashland, MA 01721 Eaton Socon,Eaton Socon, Huntingdon,
St Neots,
(262) 691-0300
Tel: +1 (262) 691-2222 (508) 881-5110
Tel: +1 (508) 881-5110 Cambs.
Cambs. PE19 8TT PE19
United 8TTKingdom
United Kingdom
FAX: 
FAX: +1 (262) 262-691-0312
691-0312 FAX: 508-881-6849
ashland@dynexhydraulics.com Tel:+44(0)(0)1480
Tel:+44 1480213980
213980 FAX:+44
FAX:+44(0)(0)1480
01480 405662
405662
E-mail: sales@dynexhydraulics.com
sales@dynexhydraulics.com E-mail: ashland@dynexhydraulics.com E-mail: sales@dynexhydraulics.co.uk
sales@dynexhydraulics.co.uk

Copyright © Dynex/Rivett Inc. Printed in U.S.A. Bulletin D03 – 11-24-21