Public health series/SK-E600A
Clinical Weighing Scales & Body Composition Analyzer Scales
Synchronous and quick
examinations in seconds
Body temperature and blood pressure
measured synchronously and quickly in
seconds, to assist outpatient triage.
Independent measurement of each item also
available.
Touch-free temperature
measurement, safe and convenient
Touch-free body temperature measurements
Touch-free operation to prevent cross-infection
of germs.
Safe and easy to use
Smart login, automatic file creation
Various login methods, such as ID card and QR
Code
Quickly identify the patient
‘Automatically upload HIS and create file
Doctors don't need to manually input data.
Main Function
8S
Height measure
,
* z
ody tempegre
— 3
Thera printing sox LO¥inby OR Code
ez it
EA =
Song Ohepiece sto!
& jl
Weight measurement e
@)
Height Weight BMI Body
Blood Blood
temperature oxygen PressurePublic health series/SK-E600A
Clinical Weighing Scales & Body Composition Analyzer Scales
Measuring system
Measuring range
Cee
Motherboard
‘Allowable eror
Measuring system
aM
Measuring range
‘Alowable eror
Degree of precision
Human body temperature measurement range
(Object temperature measurement mode
Accuracy
Power consumption
Measuring cistence
Auto power-off
‘Measuring renge
Measurement accuracy
Sereen
Transmission mode
Power supply
Operating temperature and humiity
‘Transportation & storage temperature and humisity
Operating atmospheric pressure
‘Transportation & stocage atmospheric pressure
(Overall dimensions
Host weight
‘Applicable circumference range of cut
Sensor
Wavelength
Measuring range
‘Maximum average optical output power
Measurement error
Pulee measurement error
Printing method
Printing paper width
Print span,
Resolution
Printing speed
Power raqurements
cpu
cpu
Memory
Operating system
Power input
Display interface
Display
Data output interface
Wirking humic range storage temperature range)
1D card reacer
OR cade scanner
Boxy temperature examination
10 tench esplay
Total power
Uitround
90.0 0 205m
20.50m
Resistance strain
‘Automatic smart calculation of BM
“140 500kg
s0.1kg
ore
32010425
Oto 109°
203°
120m
5to8em
approx. 185,
Pressure (20200) mmtig [0~to 40kPa]
Pulse rate 30 bean to 200 beats/min
Pressure within 22mm (20.267KPa)
Pose rate within 32%
LCD sereen
232 sefal powUss,
Power adapter (nput AC 100V to 240V, SOGOHE, ouput
DCI2V, 354)
‘SC to. 40°C, 15%RH to 80%RH
“20% 1 +850, DOW
804? to 106k
50KPa to 106kPa
(387.7mm (L) * 244.4mm (WW) * 340.2mm (H)
approx. 6.K9
‘em o42em
Duatvavelenath uminous diode
Redlight: 663m
Inrared ight 900m
35% 10 100%;
nw
Inge ane of 701 100% the measurement eres
20 to 250bpm The monitoring eros #25pm or #%2,
“whichever is the maximum
‘Thermal ing
58mm
48m
8 dotsimm (2034)
‘Max 100mmis (ne more than 25% of pint dots pet line)
C9 24v, 28
‘Super quad-core Cortex:A17 with frequeneies up to
1.8GHz
‘ARM Mali-T764 GPU, supports TE, ASTC, and AFBC
‘memory compression technology
DDR3 268, maximum support of 468
‘Android 5.1
12V, 3A,
OP interface, LVDS interface (single-channel, 6-bit
cual-channel,8-bit, 10-bit dual-channel), MII interface,
supports HOMI 2.0, supports a maximum resolution of
3,840 2,160
410.1neh, capacitive touch sereen, resolution: 4,280.x3
(RGB) x 800
LAN network interface, WHF and 46
SO 045% (10 to +800)
‘Second:generation ID card reader
Barcode and QR code
Inductive measurement
10,t2nch MIPI screen
40