You are on page 1of 3
KT15 - KT16S (50 Hz) ao" GENERATORS oa a GHADDAR Gensets ‘bola Sects Peed [Prime Rating | Stand-by Rating Voltage"! Frequency” =——KTIS® kT16s" 230/400 SoH 14.4 kVA 16.0 kVA “The above ratings represent the generating set capability guaranteed within +396 atthe reference conditions equivalent to those specified in ISO 8528/1 standard, 1.The applicable voltage range is 380V to Make & Model KUBOTA D1703-E2-BG {150 for sons apphestons For other liners & Arrangement 3- vertical inline See Bore & Stroke (mm) 87x94 2: Tha gveang st of ad seed ot Induction system Naturally aspirated : ne . hem — Combustion Indirect injection . KTS isthe prime power rating af the _generating set is where a variable load and Ode 4 stroke Unlimited hour usage are applied with an Compression ratio. 26 sree daar of oa Ne pme Cooling System Water coled rating over each 24-hour period, Noting that a 10% overload is permitted fort hourin Pipleceen 647 liters every Thou operation Lube il capacity liters Max A.KTUESe the standby power rating of Coolant capacity sslites the generating setls where a variable las Standard governor (Optional Isochronous Electronic ImiedtoanannsluageuptoS00hows# Engine Speed 1500 pm applieg with 300 hours of which may be Continuous runing Noting thst nooveriis _-*Fuel Consumption (L/H) @ 100%6Load 3.51 @50%load 176 permitted Fuel Consumption (U/H) @ 75% Load 2,64 @25%load 088 Radiator Cooling Air Flow (m3/s) 049 Emissions regulations For non-tegulated territories Gh! TEC) Cet ely Sas, The complete Generting Sets ) type-tesee according to 180 8528-8 ES Svcs cigs, -Treconol panel {ERY ented i500 ‘Sonate bert have P55 according IEC 0355 Exhaust temperature C (max) Max exhaust gas flow (m3/min) Max. allowed back pressure (kPa) 500 3.29 7 ‘The above performance data are valid as per the following specs: + Diesel Fue s accor 19 t0 852869 Class A? or equivalent + Lubricating ois according to Grade SAE 15W-40 API Cs, "The coolant should be 50% antifreeze and 50% fresh water. x= Alternator Technical Data Length 1500 mm_ Width 610 mm Height 1110 mm. 370 Kg Make &Model —_ Leroy Somer TALO40F Frequency /No.of poles S0H2/ 4? Winding pitch 23 Ingress protection P23, AVR model R120 Insulation class 4 Overspeed 2250 RPM. Terminals (Optional) 612) Voltage regulation 1% Excitation system SHUNT Coolantaairflow 0.06 m3/s www.ghaddar.com Head Quarters Facory-Ghase Sidon Lebanon Te 9617220000. Fax 961 7221754/223 322 FOO 110 Sidon. Ea inteaghadancomy Bet rane Tel 96) 1847770 Fe o96) 124775 {ne Reh otarCo F25 Harrah ee Zone, Pag Shariah UAETel 97965269177 Fa 697965269491 POO 4995 Sarah Nigers=2, Warehouse Road papa Lago il +234 7064909293 -Enal dmeghacearng com SnudAraba Rag Indust iy Yr Highway 2 827, Peto Rabigh Bg, Rabigh KSA Te #9668 3736545 Em padagh GENERATORS B: © EEreEZe Control Panel Specifications CGMP26OMK (0DSE60T0 MKI) pane isan ‘automatic start generating set panel of rmicoprocessor-based design whichis capable of interfacing with electronic engine through the can-bus J1939,Itisfully configurable by font fascia buttons and PC software as wel. If Mains voltage sto be monitored, DSE6O2OMKII can be offered Circuit Breaker Schneider or ABB, 3 Pole MCB (4 Pole available as Optional) KT14 - KT16S (50 Hz) Gensets Sects Kubota ——<_ ‘Sheet Fabrication Paint type Paint application Durability tests Compliance Degree of protection NCshearing & bending Heat-treated powder-coated Electrostatic corona spraying + IMPACT [EN 1S0 6272] + Salt spray resistance [ASTM B117-73] + Humidity Resistance (ASTM 02247] + Panelis compliant with (108528-8] + Clearance & Creepage (1E(60355-1] + Leakage curent & Dielectric strength [EC60355-1] + Protection against electric shock 1EC600 364-4-41] IPs + Crimping force up to 20KN Wire crimping + Accuracy of 0.1mm + Each crimping is checked by Komax CFA+ - Wires are coded by wire color and cross-section Wire coding Wires are coded by printed numbers - Wires are coded by printed function ofthe wire ees aie) bd SO Aaah aaa ree ‘Over /Under AC vatage High cil temperate Remote start ingut “Eurmy urge SA, 108, UL Gen ACVoltage: 3phVLL&VLN Lube olltenperature ver Under frequency High etousttenperture Emergency Sap baton feetpunp contol Gen Frequency. He huusttengernme Det Over caet Lows Cenmandlamysteecntad een Gencaret:3 phase Ege Beat ue Sha Loncoltpese Eten) hee -MsasT? Per RUA AREF Chap arcter oerk elle Weety eer 54s. Egy KM IR KBE — se WightagheTenpeatue ——_Lewalee Aube sam ie CSiader bei pres conta Low oil pressure ‘High winding temperature Standard CANbus 11939 ‘iate in Fuel Detection. Engine coolant temperature fuellevel Maintenance Alarm High Eeating temperature Preheat contr Battery DC Voltage Lube illevel Vightowsateyvotage Lone DcAtenaorvage Wingert ID Linas Mite? ste eptectn age Speeé Bevteresue id low cabt enpse pentaghows Note Thesis entatian nthe number of protections and meturement that an be ofered with GMP24OVK Other sypes of conl Panel Males canbe offered according a requed spereatons OSE 731020, 740/20, 8610 8610 and Othe Fe www.ghaddarcom ead Quarts Factory -Ghaseh ion Lebanon Tek 1961722000 Fax 9617221 754/223 222 POOR: 110 Sidon Une Ren tar Co. F2F Haran Fee Zone, hac Sharjah UAE=Tel 1979 65269917 Fax 4971 65269451 -POoe 4935) Sharh Noi oun Rnd App ags ie. 76 039 na anaghadegcom ae" GENERATORS Sa GHADDAR KT14 - KT16S (50 Hz) Kubota Gensets Tur ELL BTCD UCR cy Assembly: Gensets are assembled at Ghaddar Machinery Factory in compliance with 0 8528-8 standard Fabrication: = The engine/alternator assembly ests on skid with Anti-vibration mounting pads. ~The skid is made up of durable sheet metals and beams exceeding “Vibration & Torsion” Resistance Norms. -Askid mounted fuel tanks supplied with fuel gauge, filler cap, fuel inlet and outlet hoses. - The control panel enclosure is made up of metal sheet Paint: -The skid and control panel enclosure are painted wit heat-treated and power-coated electrostai corona spraying, - Paints passed durability tests conforming to international quality standards = Impact (EN 50 6272) + Salt Spray Resistance (ASTM B117-73) - Humidity Resistance (ASTM 2247) Works-Testing: - AllGensets are tested prir to dispatch Testis automatically generated and checked acording to 1508528 Test certificate issued foreach Genset Equipment: - Water cooled Radiator wth bet driven blower fan and full quarding - Electric starter with solenoid Relay ~ Battery Charging Alternator ~ Energized to run solenoid = Replaceable fuel, oil and ai filters ~ Heavy duty leads acd battery with matching capacity (Amps & CCA) - One loose supplied industrial exhaust silencer ~ 16 DB noise reduction eve - Integral Fuel Tank with 67 L capacity. Documentation: - User Manual for Operation, Installation and Maintenance guidance -Wring Diagram. Test Report. Maintenance Schedule = Catalogues for Engine, Alternator & AVR CCU ECL Manual & Automatic Transfer Switches, - Synchronizing & Totalizing Panels Fuel water separator “Water jacket heater -Oilheater - Fuel heater Battery heater ~ Anti-condensation Heater - hr Shut-off Valve = Oil Sampler = Pre-lube Oil Pump Five www ghaddar.cor Laban Tel-+961 7220000 Fax--9617221 754/323 222 POOR: 110 Sidon- = 2 FEE karanFree Zane Phar Shag UAE “Tel 971 6526999) Fa 497165269451 -POBoe 4935) Sharh rehouse Ros Apapa gor. el +204 706 #50933 eral dmeghadeang com

You might also like