Illustration 2 g01225334
Voltage ... 24 V
Note: Load the battery with a carbon pile 4C-4911 Battery Load Tester in order to get the maximum
alternator output.
The minimum full load current at 5000 rpm is the following value. ... 95 Amp
The minimum full load current at 2000 rpm is the following value. ... 28 Amp
Tighten the nut on the terminal to the following. ... 4.4 ± 1.0 N·m (39 ± 9 lb in)
Tighten the nut on the terminal to the following torque. ... 18.2 ± 2.4 N·m (13 ± 2 lb ft)
https://sis2.cat.com/#/print-preview/service/%257B%2522title%2522%253A%2522Alternator%2520(KENR5290-16)%2522%252C%2522formatte… 2/3
26/3/23, 14:09 SIS 2.0
(4) Tighten the shaft nut to the following torque. ... 127 ± 10 N·m (95 ± 7 lb ft)