COMPRESSORS
QOF 20, QOF 22, QOF 30
Instruction Manual
This manual contains important safety information and should be made available to
all personnel who operate and/or maintain this product. Carefully read this manual
before attempting to operate or perform maintenance on this equipment.
Manual No.
Quincy Compressor
Table of Contents
Stopping.............................................................................................................................79
Taking out of operation......................................................................................................79
Section VI - Maintenance
Preventive maintenance schedule......................................................................................80
Service kits..........................................................................................................................82
Disposal of used material...................................................................................................82
Section VII - Adjustments and servicing procedures
Air filter...............................................................................................................................83
Air cooler............................................................................................................................83
Drive motor........................................................................................................................84
Safety valve........................................................................................................................84
Belt set exchange and tensioning......................................................................................85
Cleaning the compressor element.....................................................................................85
Replacement of the outlet pipe.........................................................................................87
Dryer maintenance.............................................................................................................88
Section VIII - Problem solving........................................................................89
Section IX - Technical data
Electric cable size and fuses...............................................................................................91
Reference conditions and limitations.................................................................................97
Compressor data................................................................................................................98
Section X - Guidelines for inspection ..........................................................102
Section XI - PED (Pressure Equipment Directive) ........................................103
Section XII - Declaration of conformity........................................................104
Standard Terms and Conditions...................................................................106
Quincy Compressor
Section I - General Information
IMPORTANT!
Throughout this manual we have identified key hazards. The following symbols identify
the level of hazard seriousness:
DANGER! WARNING!
This symbol identifies immediate This symbol identifies hazards or unsafe
hazards which will result in severe practices which could result in personal
personal injury, death or substantial injury, death or substantial property
property damage. damage.
DANGER! CAUTION!
This symbol identifies life threatening Identifies hazards or unsafe practices
electrical voltage levels which will result which could result in minor personal
in severe personal injury or death. All injury or property damage.
electrical work must be performed by
a qualified electrician.
NOTICE!
CAUTION! Identifies important installation,
operation or maintenance information
This symbol identifies hot surfaces which is not hazard related.
which could result in personal injury or
property damage.
Quincy Compressor 1
Section I - General Information
Safety Precautions
Read this manual and follow all instructions • A properly sized pressure relief valve
prior to installing or operating the must be installed in the discharge
compressor. piping ahead (upstream) of any shutoff
valve (block valve), heat exchanger,
Listed below are some, but not all, safety
orifice or any potential blockage
precautions that must be observed with
point. Failure to install a pressure
compressors and compressed air systems.
relief valve could result in the rupturing
or explosion of some compressor
component.
WARNING! • Do not change the pressure setting of
the pressure relief valve, restrict the
Failure to follow any of these precautions function of the pressure relief valve, or
may result in severe personal injury, replace the pressure relief valve with
death, property damage and/or a plug. Over pressurization of system
compressor damage. or compressor components can occur,
resulting in death, severe personal
injury or property damage.
• Air from this compressor will cause
severe injury or death if used for • Never use plastic pipe, rubber hose,
breathing or food processing. Air or soldered joints in any part of the
used for these processes must compressed air system. Failure to
meet OSHA 29 CFR 1910.134 or ensure system compatibility with
FDA21XDE178.3570 regulations. compressor piping is dangerous.
• Disconnect and lockout all power • Never use a flammable or toxic solvent
supplies to the compressor plus any for cleaning the air filter or any parts.
remote controllers prior to servicing the
unit. • Do not remove any guards or cabinet
panels or attempt to service any
• Never assume it is safe to work on the compressor part while the compressor
compressor because it is not operating. is operating.
Many installations have automatic start/
stop controls and the compressor may • Do not operate the compressor at
start at any time. pressures in excess of its rating.
• This compressor is designed for use in • Observe control panel displays daily
the compression of normal atmospheric to ensure compressor is operating
air only. No other gases, vapors or properly.
fumes should be exposed to the
compressor intake, nor processed • Follow all maintenance procedures and
through the compressor. check all safety devices on schedule.
• Relieve all pressure internal to the • Never disconnect or tamper with the
compressor prior to servicing. Do not high air temperature (HAT) sensors.
depend on check valves to hold system
• Compressed air is dangerous, do not
pressure.
play with it.
2 Quincy Compressor
Section I - General Information
Quincy Compressor 3
Section I - General Information
Warranty
Quincy Compressor® Industrial Scroll Products
QOF (2-30 horsepower ONLY) Belt Drive Compressors
(Operating at 145 PSIG full load pressure or less)
Standard Warranty
Quincy Compressor (Seller) warrants products of its own manufacture against defects in
workmanship and materials under normal use and service, as follows:
Packaged Compressors - Twelve (12) months from date of start-up or eighteen (18) months
from date of shipment from the factory, whichever occurs first.
4 Quincy Compressor
Section II - Description
• General description
• Flow diagram
• Regulating system
• Electrical system
• Electric diagram
• Temperature protection
• Air dryer
General description
Introduction
QOF 20, QOF 22 and QOF 30 are stationary, oil free compressors.
Dependent on the model, the compressors have 3 or 4 electric motor driven compressor
modules, enclosed in a sound insulating canopy. The front door panel houses the controller
with graphical display and the emergency stop button. An electric cabinet with the electric
components is located behind the front panel.
The compressors can be delivered with or without integrated refrigerant air dryer.
QOF is the type designation of the compressor variant without integrated dryer. On QOF,
the compressed air of each compressor module flows via an individual check valve to a
common air cooler and leaves the compressor via the air outlet valve.
QOF with dryer compressors are QOF compressors provided with a refrigerant air dryer,
integrated in the bodywork.
The dryer removes moisture from the compressed air by cooling the air to near freezing
point and automatically draining the condensate.
Quincy Compressor 5
Section II - Description
6 Quincy Compressor
Section II - Description
Quincy Compressor 7
Section II - Description
Flow diagram
Flow diagram
8 Quincy Compressor
Section II - Description
Text on image
Air flow
Air is drawn through air filter (100) and is compressed by the compressor element (102)
of each compressor module. The compressed air is discharged via the check valve (104)
and a common air cooler (112).
On compressors without integrated dryer, the compressed air passes a water separator
(111) and flows to the outlet valve (121).
On standard compressors with an integrated air dryer, the compressed air flows through
a common refrigerant dryer (300) before reaching the outlet valve (121). For details on
the operation of the dryer, see section Refrigerant dryer.
Cooling
Each compressor element (102) is cooled by a radial fan (124), mounted on the drive
shaft of the compressor element. The cooling air is blown over the compressor element
via a duct.
A separate electric fan (130) provides cooling air for the common air cooler (112).
Condensate management
The water separator (111) on compressors without integrated dryer has an automatic
condensate outlet and a manual drain valve.
On compressors with integrated dryer, the dryer is equipped with a water trap with an
automatic condensate outlet and a manual drain valve.
Quincy Compressor 9
Section II - Description
Regulating system
The compressor is provided with an electronic controller module.
The controller performs following functions:
• Monitoring the pressure
For more details, please consult the sections on the controller further in this book.
Electrical system
Cubicle layout
10 Quincy Compressor
Section II - Description
Electric diagram
NOTICE!
• The electrical installation must correspond to the applicable codes.
• The mains supply and earthing lines must be of suitable size. See section Electric
cable size and fuses.
• The installation must be earthed and protected by fuses in each phase.
• An isolating switch must be installed near the compressor. Make sure that this switch
is open to isolate the compressor from the mains before carrying out any connection.
The complete electrical diagram is available in the electric cubicle of the compressor. For
connection of the supply wires, please see section Electrical connections.
Temperature protection
The compressor is equipped with an ambient temperature sensor. The sensor creates a
warning message on the controller if the ambient temperature rises above 40 °C (104 °F).
If the ambient temperature reaches 45 °C (113 °F), the compressor is stopped.
Quincy Compressor 11
Section II - Description
CAUTION!
When the compressor is stopped due to overheating, the compressor will not restart
until the failure is acknowledged and the compressor is restarted manually. See also
sections Shutdown warning and Shutdown.
Air dryer
Flow diagram
12 Quincy Compressor
Section II - Description
The dryers are equipped with an electronic condensate drain (EWD). The condensate
from the condensate trap accumulates in a collector. When the condensate reaches a
certain level, it is discharged through the drain outlet (1).
The condensate can also be drained by pressing the test button (2).
The drain filter can be cleaned by opening the manual drain valve (3), see section
Preventive maintenance schedule.
Quincy Compressor 13
Section III - Controller
• General
• Control panel
• Icons used
• Main screen
• Calling up menus
• Shutdown warning
• Shutdown
• Inputs menu
• Outputs menu
• Counters
• Control mode selection
• Service menu
• Setpoint menu
• Event history menu
• General settings menu
• Info menu
• Week timer menu
• Test menu
• User password menu
• Web server
• Programmable settings
General
Control panel
Introduction
The controller has following functions:
• Controlling the compressor
• Protecting the compressor
• Monitoring components subject to service
• Automatic restart after voltage failure (made inactive)
Automatic control of the compressor operation
The controller maintains the net pressure between programmable limits by automatically
starting and stopping one or more compressor modules. A number of programmable
settings, e.g. the starting and stopping pressures and the maximum allowed motor
14 Quincy Compressor
Section III - Controller
starting frequency and several other parameters are hereby taken into account.
The controller stops the compressor whenever possible to reduce the power
consumption and restarts it automatically when the net pressure decreases.
CAUTION!
A number of time based automatic start/stop commands can be programmed. Take
into account that a start command will be executed (if programmed and activated),
even after manually stopping the compressor.
Protecting the compressor
Shutdown
Several sensors are provided on the compressor. If one of the measured signals exceeds
the programmed shutdown level, the compressor will be stopped. This will be indicated
on display (1) and general alarm LED (2) will blink.
Remedy the trouble and reset the message. See also section Inputs menu.
CAUTION!
Before remedying, consult the applicable safety precautions.
Quincy Compressor 15
Section III - Controller
CAUTION!
If the function is activated and provided the regulator was in the automatic operation
mode, the compressor will automatically restart if the supply voltage to the module
is restored within the programmed time interval.
Control panel
16 Quincy Compressor
Section III - Controller
Icons used
Status icons
Motor running
Or
Network control
Quincy Compressor 17
Section III - Controller
Shutdown
Warning
Not valid
Input icons
Icon Description
Pressure
Temperature
Digital input
18 Quincy Compressor
Section III - Controller
Special protection
System icons
Icon Description
Compressor element (LP, HP, ...)
Dryer
Fan
Drain
Filter
Motor
Network problem
General alarm
Quincy Compressor 19
Section III - Controller
Menu icons
Icon Description
Inputs
Outputs
Counters
Test
Or
Settings
Service
20 Quincy Compressor
Section III - Controller
Network
Setpoint
Info
Navigation arrows
Icon Description
Up
Down
Quincy Compressor 21
Section III - Controller
Main screen
Control panel
22 Quincy Compressor
Section III - Controller
Text on image
Quincy Compressor 23
Section III - Controller
• Section D shows the Action buttons. Depending on the situation, these buttons are
used:
Designation Function
Menu To go to the menu
Modify To modify programmable settings
Reset To reset a timer or message
To activate an action button, highlight the button by using the Scroll keys and press the
Enter key.
To go back to the previous menu, press the Escape key.
Chart views
Instead of viewing values, it is also possible to view a graph of one of the input signals
(see section Inputs menu) in function of the time.
When Chart (High Resolution) is selected, the chart shows the variation of the selected
input (in this case the pressure) per minute. Also the instantaneous value is displayed.
The screen shows the last 4 minutes.
The switch button (icon) for selecting other screens is changed into a small Chart and is
highlighted (active).
24 Quincy Compressor
Section III - Controller
When the Chart (Medium Resolution) is selected, the chart shows the variation of the
selected input per hour. The screen shows the last 4 hours.
When the Chart (Low Resolution) is selected, the chart shows the variation of the
selected input per day. The screen shows the evolution over the last 10 days.
Selection of a main screen view
To change between the different screen layouts, select the far right icon in the control
icons line (see value lines display icon or chart display icon in section Icons used) and
press the Enter key. A screen similar to the one below opens:
Select the layout required and press the Enter key. See also section Inputs menu.
Quincy Compressor 25
Section III - Controller
Calling up menus
Control panel
26 Quincy Compressor
Section III - Controller
Text on image
(1) Menu
(2) Regulation
• The menu screen shows a number of icons. Each icon indicates a menu item. By
default, the Regulation icon is selected. The status bar shows the name of the menu that
corresponds with the selected icon.
• Use the Scroll keys to select the required icon (see further). Pressing the Escape key
returns to the Main screen.
Shutdown warning
Description
A shutdown warning will appear in the event of:
• Too high element temperature
• Too high ambient temperature
• Too high dew point temperature (on compressors with integrated refrigerant dryer)
High element temperature
When a compressor element temperature exceeds the warning level, the element
stops during a Minimum Stop Time . It will be restarted automatically after this time has
elapsed and if the temperature is below this limit.
As long as the element is stopped, an hourglass icon (1) replaces the element concerned
in the main screen:
Quincy Compressor 27
Section III - Controller
28 Quincy Compressor
Section III - Controller
Quincy Compressor 29
Section III - Controller
30 Quincy Compressor
Section III - Controller
Shutdown
Description
The compressor will shut down in case of:
• Too high ambient temperature
• Motor overload
• Outlet pressure sensor error
High ambient temperature
If the ambient temperature is above the factory set shutdown temperature (45 °C - 113
°F), the compressor will be stopped and a stop icon will be shown on the main screen of
the controller:
Quincy Compressor 31
Section III - Controller
Inputs menu
Menu icon, Inputs
Function
• To display the actual value of the measured data (analog inputs) and the status of the
digital inputs (e.g. emergency stop contact, motor overload relay, etc.).
• To select the digital input to be shown on the chart in the main screen.
Procedure
Starting from the Main screen,
• Move the cursor to the action button Menu and press the Enter key. Following screen
appears:
Text on image
(1) Menu
(2) Regulation
• Using the Scroll keys, move the cursor to the Inputs icon (see above, section Menu
icon).
• Press the Enter key. A screen similar to the one below appears:
Text on image
(1) Inputs
(2) Compressor outlet
32 Quincy Compressor
Section III - Controller
The first item in the list is highlighted. In this example, the Net Pressure is selected (chart
icon).
To change, press the Enter button again. A pop up window opens:
Press Enter again to remove this input from the chart. Another confirmation pop up
opens:
Quincy Compressor 33
Section III - Controller
Text on image
(1) Set As Main Chart Signal
34 Quincy Compressor
Section III - Controller
Outputs menu
Menu icon, Outputs
Function
To call up information regarding the actual status of some outputs such as the condition
of the Fan motor overload contact, the general warning contact, etc.
Procedure
Starting from the Main screen,
• Move the cursor to the action button Menu and press the Enter key. Following screen
appears:
Text on image
(1) Menu
(2) Regulation
• Using the Scroll keys, move the cursor to the outputs icon (see above).
• Press the Enter key. A screen similar to the one below appears:
Quincy Compressor 35
Section III - Controller
Counters
Menu icon, Counters
Function
To call up:
• The running hours
• The loaded hours
• The number of motor starts
• The number of hours that the regulator has been powered
• The number of load cycles
Procedure
Starting from the Main screen,
• Using the Scroll keys, move the cursor to the action button Menu and press the Enter
key. Following screen appears:
Text on image
(1) Menu
(2) Regulation
• Using the Scroll keys, move the cursor to the Counters icon (see above).
• Press the Enter key. Following screen appears:
36 Quincy Compressor
Section III - Controller
Text on image
(1) Counters
(2) Shutdowns element 2
(3) Load relay
(4) Fan starts
(5) Module hours
The screen shows a list of all counters with their actual readings.
Text on image
(1) Menu
• Next, use the scroll buttons to go to the control mode icon (2) and press the Enter
key (see section Icons used for the meaning of the icons):
Quincy Compressor 37
Section III - Controller
After selecting the required control mode, press the Enter key on the controller to
confirm your selection. The new control mode selection is now visible on the main
screen.
38 Quincy Compressor
Section III - Controller
Service menu
Menu icon, Service
Function
• To reset the service plans which are carried out.
• To check when the next service plans are to be carried out.
• To find out which service plans were carried out in the past.
• To modify the programmed service intervals.
Procedure
Starting from the Main screen,
• Move the cursor to the action button Menu and press the Enter key. Following screen
appears:
Text on image
(1) Menu
(2) Regulation
• Using the Scroll keys, move the cursor to the Service icon (see above, section Menu
icon).
• Press the Enter key. Following screen appears:
Quincy Compressor 39
Section III - Controller
Text on image
(1) Service
(2) Overview
(3) Service plan
(4) Next service
(5) History
• Scroll through the items to select the desired item and press the Enter key to see the
details as explained below.
Overview
Text on image
(1) Overview
(2) Running Hours
(3) Real Time (hours)
(4) Reset
Example for service level (A):
The figures at the left are the programmed service intervals. For Service interval A, the
programmed number of running hours is 500 hours (upper row) and the programmed
number of real time hours is 2190 hours, which corresponds to one year (second row).
This means that the controller will launch a service warning when either 500 running
hours or 2190 real hours are reached, whichever comes first. Note that the real time
hours counter keeps counting, also when the controller is not powered.
A new algorithm is implemented for a better protection of the compressor elements. The
running hours will be recalculated depending on the ambient temperature. A compressor
continuously running in an ambient temperature between 30 °C (86 °F) and 35 °C (95
°F) is working in harder conditions than an element running at 20 °C (68 °F). Therefore
a service done earlier (a time reduction of 30 % is applied in this temperature zone) will
protect the element in a better way. In the zone between 35 °C (95 °F) and 40 °C (104
°F), the time reduction is 60 %.
The figures within the bars are the number of hours to go till the next service
intervention. In the example above, the compressor was just started up, which means it
still has 500 running hours or 2187 hours to go before the next Service intervention.
Service plans
A number of service operations are grouped (called Level A, Level B, etc...). Each
40 Quincy Compressor
Section III - Controller
level stands for a number of service actions to be carried out at the time intervals
programmed in the controller.
When a service plan interval is reached, a message will appear on the screen.
After carrying out the service actions related to the indicated levels, the timers must be
reset.
From the Service menu above, select Service plan (3) and press Enter. Following screen
appears::
Text on image
(1) Service plan
(2) Level
(3) Running hours
(4) Real time hours
(5) Modify
Modifying a service plan
Dependant on the operating conditions, it can be necessary to modify the service
intervals. To do so, use the Scroll keys to select the value to be modified. A screen similar
to the one below appears:
Quincy Compressor 41
Section III - Controller
Modify the value as required, using the ↑ or ↓ scroll key and press the Enter key to
confirm.
Note: Running hours can be modified in steps of 100 hours, real time hours can be
modified in steps of 1 hour
Next Service
Text on image
(1) Next service
(2) Level
(3) Running hours
(4) Actual
In the example above, the A Service level is programmed at 500 running hours, of which
0 hours have passed.
History
The History screen shows a list of all service actions done in the past, sorted by date.
The date at the top is the most recent service action. To see the details of a completed
service action (e.g. Service level, Running hours or Real time hours), use the Scroll keys to
select the desired action and press the Enter key.
42 Quincy Compressor
Section III - Controller
Setpoint menu
Menu icon, Setpoint
Function
It is possible to program 2 different pressure bands. This menu is also used to select the
active pressure band.
Procedure
Starting from the Main screen,
• Move the cursor to the action button Menu and press the Enter key. Following screen
appears:
Text on image
(1) Menu
(2) Regulation
• Using the Scroll keys, move the cursor to the Setpoint icon (see above, section Menu
icon)
• Press the Enter key. Following screen appears:
Text on image
(1) Regulation
Quincy Compressor 43
Section III - Controller
• The first line of the screen is highlighted. Use the Scroll keys to highlight the setting
to be modified and press the Enter key. Following screen appears:
Text on image
(1) Regulation
(2) Stopping pressure
• The upper and lower limit of the setting is shown in grey, the actual setting is shown
in black. Use the ↑ or ↓ key of the Scroll keys to modify the settings as required and
press the Enter key to accept.
If necessary, change the other settings as required in the same way as described above.
44 Quincy Compressor
Section III - Controller
Function
To call up the last shutdown and last emergency stop data.
Procedure
Starting from the Main screen,
• Using the Scroll keys, move the cursor to the action button Menu and press the Enter
key. Following screen appears:
Text on image
(1) Menu
(2) Regulation
• Using the Scroll keys, move the cursor to the Event History icon (see above).
• Press the Enter key. The list of last shutdown and emergency stop cases is shown.
Quincy Compressor 45
Section III - Controller
Function
To display and modify a number of settings.
Procedure
Starting from the Main screen,
• Move the cursor to the action button Menu and press the Enter key. Following screen
appears:
Text on image
(1) Menu
(2) Regulation
• Using the Scroll keys, move the cursor to the Settings icon (see above)
• Press the Enter key. Following screen appears:
This screen shows again a number of icons. By default, the User Password icon is
selected. The status bar shows the description that corresponds with the selected icon.
Each icon covers one or more items , such as
• Access level
• Elements
• Dryer
46 Quincy Compressor
Section III - Controller
• Fan
• Filter(s)
• Motor/Starter
• General
• Automatic restart after voltage failure
• Network
• Regulation
• Remote
For adapting certain parameters, a password may be necessary.
Example: Selecting the General Settings icon gives the possibility to change e.g. the
language, the date, the date format, etc.:
Text on image
(1) General
(2) Language In Use
(3) Time
(4) Date
(5) Date Format
(6) Modify
• To modify, select the Modify button using the Scroll keys and press the Enter key.
• A screen similar to the one above is shown, the first item (Language) is highlighted.
Use the ↓ key of the Scroll keys to select the setting to be modified and press the
Enter key.
• A pop up screen appears. Use the ↑ or ↓ key to select the required value and press
the Enter key to confirm.
Quincy Compressor 47
Section III - Controller
Info menu
Menu icon, Info
Function
Shows the SPIRALAIR internet address.
Procedure
Starting from the Main screen,
• Move the cursor to the action button Menu and press the Enter key. Following screen
appears:
Text on image
(1) Menu
(2) Regulation
• Using the Scroll keys, move the cursor to the Info icon (see above, section Menu
icon).
• Press the Enter key. The internet address appears on the screen.
48 Quincy Compressor
Section III - Controller
Function
• To program time based start/stop commands for the compressor.
• To program time based changeover commands for the net pressure band.
• Four different week schemes can be programmed.
• A week cycle can be programmed, a week cycle is a sequence of 10 weeks. For each
week in the cycle, one of the four programmed week schemes can be chosen.
Notice!
Important remark:
You can select different timers on one day.(up to 8 actions). It is however not possible to
program 2 actions at the same time. The solution: leave at least 1 minute in between 2 actions.
Example: Start Compressor: 5.00 AM, Pressure Setpoint 2: 5.01 AM (or later).
Procedure
Starting from the Main screen,
• Move the cursor to the action button Menu and press the Enter key. Use the Scroll
buttons to select the Timer icon.
Text on image
(1) Menu
(2) Regulation
• Press the Enter key on the controller. Following screen appears:
Quincy Compressor 49
Section III - Controller
Text on image
(1) Week Timer
(2) Week Action Schemes
(3) Week Cycle
(4) Status
(5) Week Timer Inactive
(6) Remaining Running Time
The first item in this list is highlighted. Select the item to be adapted and press the Enter
key on the controller to modify.
Programming week schemes
• Select Week action schemes and press Enter. A new window opens. The first item
in the list is highlighted in red. Press the Enter key on the controller to modify Week
Action Scheme 1.
Text on image
(1) Week Action Schemes
(2) Week Action Schemes 1
(3) Week Action Schemes 2
(4) Week Action Schemes 3
(5) Week Action Schemes 4
50 Quincy Compressor
Section III - Controller
• A weekly list is shown. Monday is automatically selected and highlighted in red. Press
the Enter key on the controller to set an action for this day.
Text on image
(1) Week Action Scheme 1
(2) Monday
(3) Tuesday
(4) Wednesday
(5) Thursday
(6) Friday
(7) Saturday
(8) Sunday
• A new window opens. The Modify action button is selected. Press the enter button
on the controller to create an action.
Text on image
(1) Monday
(2) Modify
• A new popup window opens. Select an action from this list by using the Scroll keys on
the controller. When ready press the Enter key to confirm.
Quincy Compressor 51
Section III - Controller
Text on image
(1) Monday
(2) Actions
(3) Remove
(4) Start
(5) Stop
(6) Pressure Setpoint 1
(7) Modify
• A new window opens. The action is now visible in the first day of the week.
Text on image
(1) Monday
(2) Start
(3) Save
(4) Modify
• To adjust the time, use the Scroll keys on the controller and press the Enter key to
confirm.
52 Quincy Compressor
Section III - Controller
• A new pop up window opens. Use the ↑ or ↓ key of Scroll keys to modify the values
of the hours. Use the ← or → Scroll keys to go to the minutes.
Text on image
(1) Monday
(2) Time
(3) Save
(4) Modify
• Press the Escape key on the controller. The action button Modify is selected. Use the
Scroll keys to select the action Save.
Text on image
(1) Monday
(2) Start
(3) Save
Quincy Compressor 53
Section III - Controller
(4) Modify
• A new pop-up window opens. Use the Scroll keys on the controller to select the
correct actions. Press the Enter key to confirm.
Text on image
(1) Monday
(3) Are you sure?
(4) No
(5) Yes
(6) Save
(7) Modify
(7) Modify
Press the Escape key to leave this window.
• The action is shown below the day the action is planned.
Text on image
(1) Week Action Scheme 1
(2) Monday - Start
(3) Tuesday
(4) Wednesday
(5) Thursday
(6) Friday
54 Quincy Compressor
Section III - Controller
(7) Saturday
(8) Sunday
Press the Escape key on the controller to leave this screen.
Programming the week cycle
A week cycle is a sequence of 10 weeks. For each week in the cycle, one of the four
programmed week schemes can be chosen.
• Select Week Cycle from the main Week Timer menu list.
Text on image
(1) Week Timer
(2) Week Action Schemes
(3) Week Cycle
(4) Status
(5) Week Timer Inactive
(6) Remaining Running Time
• A list of 10 weeks is shown.
Text on image
(1) Week Cycle
(2) Week 1
(3) Week 2
Quincy Compressor 55
Section III - Controller
(4) Week 3
(5) Week 4
(6) Modify
Press the Enter key twice to modify the first week.
• A new window opens. Select the action, example: Week Action Scheme 1
Text on image
(1) Week Cycle
(2) Week 1
(3) Week Action Scheme 1
(4) Week Action Scheme 2
(5) Week Action Scheme 3
(6) Modify
• Check the status of the Week Timer
Use the Escape key on the controller to go back to the main Week Timer menu. Select
the status of the Week Timer.
Text on image
(1) Week Timer
(2) Week Action Schemes
(3) Week Cycle
(4) Status
56 Quincy Compressor
Section III - Controller
Text on image
(1) Week Timer
(2) Week
(3) Week Timer Inactive
(4) Week 1
• Press the Escape key on the controller to leave this window. The status shows that
week 1 is active.
Text on image
(1) Week Timer
(2) Week Action Schemes
(3) Week Cycle
(4) Status
(5) Remaining Running Time
• Press the Escape key on the controller to go to the main Week Timer menu. Select
Remaining Running Time from the list and press the Enter key on the controller to
Modify.
Quincy Compressor 57
Section III - Controller
• This timer is used when the week timer is set and for certain reasons the compressor
must continue working, for example, 1 hour, it can be set in this screen. This timer is
prior to the Week Timer action.
Text on image
(1) Week Timer
(2) Week Action Schemes
(3) Remaining Running Time
58 Quincy Compressor
Section III - Controller
Test menu
Menu icon, Test
or
Function
• To carry out a display test, i.e. to check whether the display and LED’s are still intact.
Procedure
Starting from the Main screen,
• Move the cursor to the action button Menu and press the Enter key (2). Following
screen appears:
• Using the scroll keys, move the cursor to the test icon (see above)
• Press the Enter key, following screen appears:
Text on image
(1) Test
(2) Safety Valve Test
(3) Not allowed
Quincy Compressor 59
Section III - Controller
Function
If the password option is activated, it is impossible for not authorized persons to modify
any setting.
Procedure
Starting from the Main screen,
• Move the cursor to the action button Menu and press the Enter key. Following screen
appears:
Text on image
(1) Menu
(2) Regulation
• Using the Scroll keys, select the Settings icon (see section General settings menu).
• Press the Enter key. Following screen appears:
60 Quincy Compressor
Section III - Controller
• Move the cursor to the Password icon (see above, section Menu icon)
• Select Modify, using the Scroll keys and press the Enter key. Next, modify the
password as required.
Web server
The controller has a built-in web server that allows direct connection to the company
network or to a dedicated PC via a local area network (LAN). This allows to consult
certain data and settings via a PC instead of on the display of the controller.
Getting started
Make sure you are logged in as administrator.
• Use the internal network card from your computer or a USB to LAN adapter (see
picture below).
Quincy Compressor 61
Section III - Controller
• Select the Local Area connection (1), which is connected to the controller.
62 Quincy Compressor
Section III - Controller
• Use the check box Internet Protocol (TCP/IP) (1) (see picture). To avoid conflicts,
uncheck other properties if they are checked. After selecting TCP/IP, click on the
Properties button (2) to change the settings.
Quincy Compressor 63
Section III - Controller
• Subnetmask 255.255.255.0
Click OK and close network connections.
Configuration of the web server
Configure the web interface (for Internet Explorer)
• Open Internet Explorer and click on Tools - Internet options (2).
• Click on the Connections tab (1) and then click on the LAN settings button (2).
• In the Proxy server Group box, click on the Advanced button (1).
64 Quincy Compressor
Section III - Controller
• In the Exceptions Group box, enter the IP address of your controller. Multiple IP
addresses can be given but they must be separated with semicolons (;).
Example: Suppose that you already added two IP addresses (192.168.100.1 and
192.168.100.2). Now you add 192.168.100.100 and separate the 3 IP addresses by
putting semicolons between them (1) (see picture).
Click OK (2) to close the window.
Quincy Compressor 65
Section III - Controller
66 Quincy Compressor
Section III - Controller
Compressor settings
All compressor settings can be displayed or hidden. Put a check mark in front of each
point of interest and it will be displayed. Only the machine status is fixed and can not be
removed from the main screen.
Analog inputs
Lists all current analog input values. The measurement units can be changed in the
preference button from the navigation menu.
Counters
Lists all current counter values from controller and compressor.
Info status
Machine status is always shown on the web interface.
Quincy Compressor 67
Section III - Controller
Digital inputs
Lists all Digital inputs and their status.
Digital outputs
Lists all Digital outputs and their status.
Special protections
Lists all special protections of the compressor.
Service plan
Displays all levels of the service plan and their status. This screen shot underneath only
shows the running hours. It is also possible to show the current status of the service
interval.
68 Quincy Compressor
Section III - Controller
Programmable settings
Compressors without built-in refrigeration dryer
Quincy Compressor 69
Section III - Controller
Parameters
Protections
Minimum setting Factory setting Maximum setting
Ambient temperature warn- °C 0 40 40
ing level
Ambient temperature warn- °F 32 104 104
ing level
Ambient temperature shut- °C 0 45 45
down level
Ambient temperature shut- °F 32 113 113
down level
70 Quincy Compressor
Section III - Controller
Service plan
The built-in service timers will give a Service warning message after their respective pre-
programmed time interval has elapsed.
Also see section Preventive maintenance schedule.
Consult your supplier if a timer setting has to be changed. The intervals must not exceed
the nominal intervals and must coincide logically. See section Service menu.
Terminology
Term Explanation
ARAVF Automatic Restart After Voltage Failure. See section General.
Power recovery Is the period within which the voltage must be restored to have an auto-
time matic restart. Is accessible if the automatic restart is activated. To activate
the automatic restart function, consult your supplier.
Restart delay This parameter allows to programme that not all compressors are restarted
at the same time after a power failure (ARAVF active).
Delay at shut- Is the time for which the signal must exist before the compressor is shut
down signal down. If it is required to program this setting to another value, consult your
supplier.
Minimum stop Once the compressor has automatically stopped, it will remain stopped for
time the minimum stop time, whatever happens with the net air pressure. Con-
sult your supplier if a setting lower than 20 seconds is required.
Starting / stop- The regulator does not accept inconsistent settings, e.g. if the stopping
ping pressure pressure is programmed at 7.0 bar(e) (101 psi(g)), the maximum limit for
the starting pressure changes to 6.9 bar(e) (100 psi(g)). The recommended
minimum pressure difference between starting and stopping is 0.6 bar (9
psi(g)).
Quincy Compressor 71
Section IV - Installation guidelines
• Dimension drawing
• Installation proposal
• Electrical connections
• Pictographs
Dimension drawing
The dimension drawings can be found on the CD, delivered with the compressor.
Hereby a list of commonly used terms with their translation:
Installation proposal
Outdoor/altitude operation
NOTICE!
If the compressor is installed outdoors or if the air inlet temperature can be below
0 °C (32 °F), precautions must be taken. In this case, and also if operating at high
altitude, consult your supplier.
72 Quincy Compressor
Section IV - Installation guidelines
Installation proposal
Reference Description
1 Minimum free area to be reserved for the compressor installation
2 Ventilation proposals
Procedure
1. Install the compressor on a level floor, suitable for taking the weight of the
compressor in a frost free and preferably low dust location.
2. Compressed air outlet valve.
3. Delivery pipe.
The pressure drop over the air delivery pipe can be calculated as follows:
Δp = (L x 450 x Qc1.85) / (d5 x P), with
d = inner diameter of the pipe in mm
Quincy Compressor 73
Section IV - Installation guidelines
74 Quincy Compressor
Section IV - Installation guidelines
Electrical connections
Attention
WARNING!
The electrical installation must correspond to the local codes. The mains supply
and earthing lines must be of suitable size.
The installation must be earthed and protected by fuses in each phase. An
isolating switch should be installed near the compressor.
Make sure that this switch is open to isolate the compressor from the mains before
carrying out any connection.
To preserve the protection degree of the electric cubicle and to protect its
components from dust from the environment, it is mandatory to use a proper
cable gland when connecting the supply cable to the compressor.
Supply cable
Consult section Electric cable size and fuses for the section of the power supply cable.
Connect the supply cable to terminals L1, L2 and L3 of terminal strip (1X0), connect
the neutral conductor to terminal (N) (if applicable) and the earthing conductor to the
earthing bolt (1X3).
Quincy Compressor 75
Section IV - Installation guidelines
Pictographs
Pictographs
Pictographs
Reference Description
1 Automatic condensate drain
2 Warning: before connecting compressor electrically, consult Instruction
book for motor rotation direction
3 Consult the specific instructions before greasing
4 Manual condensate drain
5 Torques for steel (Fe) or brass (CuZn) bolts
6 Switch off the voltage and depressurize the compressor before mainte-
nance or repair
7 Warning: voltage
8 Warning: hot surface
9 Rotation direction of fan
76 Quincy Compressor
Section V - Operating instructions
• Initial start-up
• Starting
• During operation
• Stopping
• Taking out of operation
Initial start-up
Safety
CAUTION!
The operator must apply all relevant Safety precautions.
Initial start-up procedure
1. Remove the red painted transport brackets (2).
2. Check the settings of the overload relays. See section Electric cable size and fuses.
3. Connect the compressor electrically. See section Electrical connections.
4. Close the condensate drain valve. See chapter Condensate management in section
Flow diagram.
5. Switch on the voltage. Start and stop the compressor. On 3-phase compressors,
check for correct direction of rotation (direction arrows are provided on the motors).
If the rotation direction is wrong, switch off the voltage and reverse two incoming
electric lines.
Quincy Compressor 77
Section V - Operating instructions
Starting
Procedure
1. Open the air outlet valve. See section Introduction for its location.
2. Switch on the voltage.
3. Close all manual condensate drain valves.
4. Press the start button (1). The compressor starts running and automatic operation
LED lights up.
5. The regulator will automatically stop and start the compressor modules in function
of the air pressure.
6. On compressors with integrated dryer, the nominal pressure dew point will be
reached after a few minutes.
NOTICE!
The number of starts is limited to 30 starts per hour. See also section Programmable
settings.
During operation
Procedure
1. If the automatic operation LED (3) is alight, the regulator is automatically
controlling the compressor modules (starting/stopping).
2. Check the readings on the display (1). In case of a warning or shutdown condition,
see section Problem solving or Event history menu.
78 Quincy Compressor
Section V - Operating instructions
Stopping
Procedure
Quincy Compressor 79
Section VI - Maintenance
CAUTION!
Before carrying out any maintenance, repair work or adjustments, proceed as follows:
• Stop the compressor.
• Switch off the voltage and open the isolating switch.
• Press the emergency stop button (S3).
• Close the air outlet valve.
• Depressurize the compressor by opening the manual drain valve(s).
The operator must apply all relevant Safety precautions during maintenance or repair.
Warranty - Product Liability
Use only authorized parts. Any damage or malfunction caused by the use of
unauthorized parts is not covered by Warranty or Product Liability.
General
When servicing, replace all removed gaskets, O-rings and washers.
Intervals
The local Customer Centre may overrule the specified maintenance schedule, especially
the service intervals, depending on the environmental and operating conditions of the
compressor.
NOTICE!
The longer interval checks must always include the shorter interval checks.
Preventive maintenance schedule
A number of service operations are grouped in plans called Service plans I, A, B or D.
See the table below. A message will appear on the controller display when reaching
the interval, indicating which Service plans are to be carried out. After servicing, the
regulator is to be reset. For detailed information, consult section Service menu.
80 Quincy Compressor
Section VI - Maintenance
Quincy Compressor 81
Section VI - Maintenance
Notes:
1. Maintenance must be done according the number of running hours or according the
running period, whichever comes first.
2. More frequently in a dusty environment.
3. Important note: Regreasing of the bearings of the compressor element must be
done with special grease, a special grease gun and according a specific procedure.
In high ambient conditions, the bearings must be greased more frequently: for
every 5 °C (9 °F) increase above 30 °C (86 °F), the maintenance interval should be
reduced with 30 %.
Contact your supplier for details.
Check more frequently if operating in a dusty atmosphere. Check for cleanness and
damage. Replace a dirty or damaged filter by a new one.
4. In extremely dry conditions (relative humidity below 15 %), the tip seals and dust
seals need to be replaced more frequently.
Service kits
Service kits
For overhauling and for preventive maintenance, a wide range of service kits is available.
Service kits comprise all parts required for servicing the component and offer the
benefits of genuine parts while keeping the maintenance budget low.
Consult the Spare Parts List for part numbers.
82 Quincy Compressor
Section VII - Adjustments and servicing procedures
• Air filter
• Air cooler
• Drive motor
• Safety valve
• Belt set exchange and tensioning
• Cleaning the compressor element
• Replacement of the outlet pipe
• Dryer maintenance
Air filter
Procedure
Air cooler
Cleaning
Keep the cooler clean to maintain cooling efficiency. If necessary, remove any dirt with a
fibre brush. Never use a wire brush or metal objects.
Next, clean by air jet in reverse direction of normal flow.
Quincy Compressor 83
Section VII - Adjustments and servicing procedures
Drive motor
Instructions
The motor bearings are greased for life and do not require special attention.
Keep the motor free from dust for optimal cooling.
Safety valve
CAUTION!
No adjustments are allowed. Never run the compressor without safety valve.
84 Quincy Compressor
Section VII - Adjustments and servicing procedures
CAUTION!
• Compressor element cooling channels can be hot when the compressor has just been
turned off.
• Do not clean the cooling channels with organic solvent since this will damage the
surface treatment.
The purpose of cleaning the cooling channels of a scroll element is to prevent the
cooling channels to silt up and as such reduce the cooling efficiency. A reduced cooling
efficiency can lead towards a premature compressor element failure.
Quincy Compressor 85
Section VII - Adjustments and servicing procedures
Procedure:
1. Stop the compressor and switch off the power.
2. Close the air outlet valve and depressurise the compressor.
3. Remove the fan duct:
• Unscrew the 3 bolts (1).
• Remove clip (2) (if applicable).
86 Quincy Compressor
Section VII - Adjustments and servicing procedures
Procedure
1. Stop the compressor, depressurize and switch off the voltage.
2. Loosen the coupling (3) while fixating the nipple (2) with a spanner.
Quincy Compressor 87
Section VII - Adjustments and servicing procedures
Dryer maintenance
(only applicable to compressors with refrigerant dryer)
Safety precautions
The dryer circuit contains refrigerant. When handling refrigerant, all applicable Safety
precautions during maintenance or repair must be observed. Specifically be aware of
following points:
• Contact of liquid refrigerant with the skin can cause freezing. Wear special gloves.
If contacted with the skin, the skin should be rinsed with water. On no account may
clothing be removed.
• Fluid refrigerant can also cause freezing of the eyes. Wear safety glasses.
• Avoid inhalation of refrigerant vapors. Check that the working area is adequately
ventilated.
Be aware that internal components of the dryer such as the pipes can reach a
temperature of up to 110˚C (230˚F). Therefore, wait until the dryer has cooled down
before removing the side panels.
Before starting any maintenance or repair work, switch off the voltage and close the air
outlet valve.
Local legislation may stipulate that:
• Work on the refrigerant circuit of the cooling dryer or on any equipment which
influences its function must be undertaken by an authorized control body.
• The installation should be checked once a year by an authorized control body.
General
The following remarks should be kept in mind:
• Keep the dryer clean.
• Brush or blow off the finned surface of condenser regularly.
Device settings
The regulating and safety devices are factory adjusted to obtain optimum performance
of the dryer. Do not alter the setting of any of the devices.
CAUTION!
Connecting pressure measuring devices in the refrigerant circuit can change the
amount of refrigerant in the system. This results in a less optimal working of the dryer.
88 Quincy Compressor
Section VIII - Problem solving
NOTICE!
Before carrying out any maintenance or repair, perform following steps:
• Stop the compressor and switch off the voltage.
• Open and lock the isolating switch to prevent an accidental start.
• Isolate the compressor by closing the outlet valve.
• Depressurize the system by opening the drain valve(s).
Compressor
Refrigerant dryer
For compressors with a built-in refrigerant dryer also:
Quincy Compressor 89
Section VIII - Problem solving
90 Quincy Compressor
Section IX - Technical data
Quincy Compressor 91
Section IX - Technical data
Q21/
Compre-
Max Max Q22/
ssor Itot (1) Itot (2) Q15
fuse (1) fuse (2) Q23/
type
Q24
QOF 22 IEC 50 Hz 230 V 64 A 80 A 69 A 80 A 23.3 A 0.38 A
QOF 22 IEC 60 Hz 380 V 40 A 50 A 44 A 50 A 14.5 A 0.26 A
QOF 22 IEC 50 Hz 400 V 37 A 50 A 40 A 50 A 13.4 A 0.22 A
400 V
QOF 22 IEC 50 Hz 37 A 50 A 44 A 50 A 13.4 A 0.22 A
+N
QOF 22 UL/cUL 60 Hz 200 V 76 A 90 A 84 A 100 A 25.0 A 0.74 A
QOF 22 UL/cUL 60 Hz 230 V 66 A 80 A 73 A 90 A 24.0 A 0.26 A
QOF 22 UL/cUL 60 Hz 460 V 33 A 40 A 37 A 45 A 12.0 A 0.43 A
QOF 22 UL/cUL 60 Hz 575 V 27 A 30 A 30 A 35 A 9.6 A 0.44 A
Q21/
Compre-
Max Max Q22/
ssor Itot (1) Itot (2) Q15
fuse (1) fuse (2) Q23/
type
Q24
QOF 30 IEC 50 Hz 230 V 85 A 100A 90 A 125 A 23.3 A 0.38 A
QOF 30 IEC 60 Hz 380 V 53 A 63 A 57 A 63 A 14.5 A 0.26 A
QOF 30 IEC 50 Hz 400 V 49 A 63 A 52 A 63 A 13.4 A 0.22 A
400 V
QOF 30 IEC 50 Hz 49 A 63 A 58 A 63 A 13.4 A 0.22 A
+N
QOF 30 UL/cUL 60 Hz 200 V 101 A 125 A 109 A 125 A 25.0 A 0.74 A
QOF 30 UL/cUL 60 Hz 230 V 88 A 110 A 94 A 125 A 24.0 A 0.26 A
QOF 30 UL/cUL 60 Hz 460 V 44 A 60 A 48 A 60 A 12.0 A 0.43 A
QOF 30 UL/cUL 60 Hz 575 V 35 A 40 A 38 A 40 A 9.6 A 0.44 A
Itot (1): maximum current in the supply lines at maximum load and nominal voltage for
compressors without integrated dryer.
Max fuse (1): maximum fuse size in case of compressors without integrated dryer.
Itot (2): maximum current in the supply lines at maximum load and nominal voltage for
compressors with integrated dryer.
Max fuse (2): maximum fuse size in case of compressors with integrated dryer.
IEC fuses: class gL/gG
UL fuses: class K5; CSA: HRC form II
92 Quincy Compressor
Section IX - Technical data
Possible configurations
There are 3 possible cabling layouts:
• (1): Single supply cables (for DOL variants, only K21 is used)
• (2): Parallel supply cables (for DOL variants, only K21 is used)
• (3) is only valid for Y-D versions
Cable sizing according IEC
The tables below indicate the current carrying capacities of cables for 3 commonly
used installation methods, calculated according to standard 60364-5-52 - electrical
installations of buildings part 5 - selection and erection equipment and section 52 -
current carrying capacities in wiring systems.
The allowed currents are valid for PVC insulated cables with three loaded copper
conductors (maximum conductor temperature 70 °C).
Maximum allowed current in function of the ambient temperature for installation method
B2
Ambient temperature
Cable
30 °C 40 °C 45 °C 50 °C 55 °C
section
4 mm² < 27 A < 23 A < 21 A < 19 A < 16 A
6 mm² < 34 A < 30 A < 27 A < 24 A < 21 A
10 mm² < 46 A < 40 A < 36 A < 33 A < 28 A
16 mm² < 62 A < 54 A < 49 A < 44 A < 38 A
25 mm² < 80 A < 70 A < 63 A < 57 A < 49 A
35 mm² < 99 A < 86 A < 78 A < 70 A < 60 A
50 mm² < 118 A < 103 A < 93 A < 84 A < 72 A
70 mm² < 149 A < 130 A < 118 A < 106 A < 91 A
95 mm² < 179 A < 156 A < 141 A < 127 A < 109 A
120 mm² < 206 A < 179 A < 163 A < 146 A < 126 A
Quincy Compressor 93
Section IX - Technical data
Maximum allowed current in function of the ambient temperature for installation method
C
Ambient temperature
Cable
30 °C 40 °C 45 °C 50 °C 55 °C
section
4 mm² < 32 A < 28 A < 25 A < 23 A < 20 A
6 mm² < 41 A < 36 A < 32 A < 29 A < 25 A
10 mm² < 57 A < 50 A < 45 A < 40 A < 35 A
16 mm² < 76 A < 66 A < 60 A < 54 A < 46 A
25 mm² < 96 A < 84 A < 76 A < 68 A < 59 A
35 mm² < 119 A < 104 A < 94 A < 84 A < 73 A
50 mm² < 144 A < 125 A < 114 A < 102 A < 88 A
70 mm² < 184 A < 160 A < 145 A < 131 A < 112 A
95 mm² < 223 A < 194 A < 176 A < 158 A < 136 A
120 mm² < 259 A < 225 A < 205 A < 184 A < 158 A
Maximum allowed current in function of the ambient temperature for installation method
F
Ambient temperature
Cable
30 °C 40 °C 45 °C 50 °C 55 °C
section
25 mm² < 110 A < 96 A < 87 A < 78 A < 67 A
35 mm² < 137 A < 119 A < 108 A < 97 A < 84 A
50 mm² < 167 A < 145 A < 132 A < 119 A < 102 A
70 mm² < 216 A < 188 A < 171 A < 153 A < 132 A
95 mm² < 264 A < 230 A < 209 A < 187 A < 161 A
120 mm² < 308 A < 268 A < 243 A < 219 A < 188 A
Calculation method for IEC:
• Single supply cables (3 phases + PE - configuration (1)):
• Add 10 % to the total current (Itot from the tables)
94 Quincy Compressor
Section IX - Technical data
Quincy Compressor 95
Section IX - Technical data
8 50 A
6 65 A
4 85 A
3 100 A
2 115 A
1 130 A
Correction factors
Always check the voltage drop over the cable (less than 5 % of the nominal voltage is
recommended).
Example of supply cable calculation: Itot = 28 A, maximum ambient temperature is 40°C,
recommended fuse = 40
• Single supply cables (3 phases + 1 PE - configuration (1)):
• I = 28 A + 25 % = 28 x 1.25 = 35 A
96 Quincy Compressor
Section IX - Technical data
Quincy Compressor 97
Section IX - Technical data
Compressor data
Notice!
All data specified below apply under reference conditions, see section Reference
conditions and limitations.
8 bar compressors, 50 Hz
98 Quincy Compressor
Section IX - Technical data
10 bar compressors, 50 Hz
Quincy Compressor 99
Section IX - Technical data
Guidelines
On the Declaration of Conformity / Declaration by the Manufacturer, the harmonised
and/or other standards that have been used for the design are shown and/or referred to.
The Declaration of Conformity / Declaration by the Manufacturer is part of the
documentation that is supplied with this compressor.
Local legal requirements and/or use outside the limits and/or conditions as specified by
the manufacturer may require other inspection periods as mentioned below.
Overall rating
The compressors conform to PED category I or smaller.
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________
____________________________________________________________________