VERTEX CALIBRATION W.L.L ees 3 g_ Tel 49144466 1126| Fax 19744017 2179 | Ema: ino@vertexcal com By 8 (pated wwvertexcalbration.com CALIBRATION CERTIFICATE Certificate Number: VCS2023-154 \VC-RF-M-46, REV. NO: 01, REVDATE: MARCH 2022 Customer Name : ADVANCE CONSTRUCTION TECHNOLOGY SERVICES (ACTS) Address Doha Qatar Delivery Date 9-Jan-2023, CSR Number ‘cR/30/001 Calibration Date: 8-Jan-2023 Date Received S-Jan-2023, Suggested Due Date : 7-lan-2024 Description Load Cell With Display Indicator Validity 2 Tyear Brand / Make Interface Manufacturing Received Condition : In Tolerance Model / Type 121 1BAY-25KN-TB / 9320-1 TEDS Returned Condition: in Tolerance Serial Number +1 513266A / 17026982 Calibration Status: Pass Equipment ID Number: N/A Location Vertex Lab Size / Range 2 25 kN Temperature 2 242°C Resolution/Least Count: 1 kN. Humidity 51.8 %RH Calibration Procedure: VC/CM/M/31 Page Number 2 1of2 DETAILS OF MASTER INSTRUMENTS USED FOR CALIBRATION DESCRIPTION ‘ASSET NUMBER BRAND/MAKE MODEL/TYPE DUEDATE TRACEABILITY NUMBER Load Cell \VER-CAL-LC-03, Moorehouse Psp i-dun-23 c1o1aaer 121 Barometric Pressure -VER-CAL-BAR-001 tech sp700 2A-Jun-23, 08-20-A.098837 Remarks: 1. Averages of minimum three readings are reported, 2. Suggested due date and test points were given based on customer requirements. 3. These results are obtained at the time of calibration 4. The user should determine the suitability of the instrument for its intended use. 5. Uncertainty of measurement at 95% confidence level by multiplying coverage factor k = 2. 6. Condition of instrument found satisfactory during receipt. 7. Our masters are directly calibrated through ISO/IEC 17025 accredited calibration lab having direct traceability with national / Intemational standard, 8. Vertex Calibration Laboratory is accredited in accordance with the recognized International Standard as per ISO/IEC 17025:2017. 9. UUC- Unit Under Calibration 10,Pass/ Fail criteria is decided by comparing the error of the unit under calibration and its associated by measurement uncertainty with the tolerance specified by the manufacturer / customer. ‘11-Accuracy, tolerance and acceptance criteria stated as per customer requierments. ‘12.Any hand written corrections (except @) or photocopies of the report invalidate this certificate. ‘1BResults reported outside the scope af accreditation are mark with asterisk (1 Calibrated By: — if |veriex, Rustum Tristan Jokico Ge Pate aS aa Mohideen Math Calibration Technician ETE Rohe Cater_| (QNQC Engineer Calration eee are esting due des wer submited/approve by the eutomer Any numberof factor may case an nstument to dt cut of tlerance before the net scheduled of ‘alorationRecabration cys shouldbe based frequency of sed envionment condition an catomers exabshed static accuracy The Ifematon on this apart peti ony to ‘he intranet cei ‘Tic ceiato may not be reproduce ther han nfl except ha pe wit apron fing boron, Thi eport sl not be vl i not companied with Veer Caton fiat. VERTEX CALIBRATION W.L.L aliens ee : eg Tel:#876 46.46 1126| Fax: +974 4017 2179 Emal : info@verexcal com Bp (yt Soe ‘wwwsertexcalbrationom CALIBRATION RESULT Certificate Number: VCS2023-154 Ye-RF-M46,REV.NO:01, REVDATE: MARCH 2022 Description Toad Call With Display Tndieate ‘CSR Number CSRBONOT Calibration Procedure : VC/CM/M/31 : Calioation Date + Ban-2023, Serial Number 5132664 / 1702692 Suggested Due Date TJan-2026 Equipment ID Numbe : N/A Model /Type 121 1BAY-25KN-TB / 9320-1 TEDS Brand / Make Interface Manufacturing Size/Range 2 25KN Temperature pare Location Vertex Lab Humidity S1.8%RH Page Number 2of2 Force Accuracy Nominal Load in kN er Reesing During ie Carationin kN average | Percentage Error Tolerance Estimated Uncertainty # Runt Run 2 Run3 Reading in kN ba KN kv ° 0.000 0.000 0.000 0.000 - 7 - - 5 4987 4991 4985 4988 261 0063 | PASS 0.0058 10 9979 9986 9977 9980 210 0063 PASS oot19 15 4965 497314878 tage 0.234 0.063 PASS 00216 20 19953 | 1996119965 19.960 0236 0.063 PASS 0.0317 25 24986 2498524981 24984 0.056 0.063 PASS 0.0420 "= End of Calibration = Where statements of conformity are made inthis report, the following decision rules are applied PASS - Results + expanded uncertainty within limits / specification FAIL- Results + expanded uncertainty exceeds limit / specification INDETERMINATE - Results + expanded uncertainty overlaps limit / specification Calibrated By: Fi Approved By: i if vertex, bes, + 1S ppd cb ls unin : Rustum Tristan Jokico L ¥ C.R.No: 125408, Doha « Qatar Mohideen Maajith Calibration Technician ne QA/QC Engineer "Thi eae yt be epoca ha in ul pt i pr wit apo of dng botany Taree shl nebo ot cope wth Vrs olin cl

You might also like