"ZEA DASHENG ZONGHENG Digital Gauge & Manifolds Operation Manual WK-6881H WK-6881L Single Manifold/High Side Single ManifoldiLow Side WK-6882 WK-6884 2 Valves Digital Manifold 4 Valves Digital Manifold DIGITAL GAUGE INTRODUCTION BSZH’ Digital gauges adopt advanced digital circuit and high accuracy pressure sensor. used for both high accuracy refrigerant pressure and vacuum pressure. 82 refrigerants build-in according to NIST standard refrigerants pressure and temperature relationship database.real-time test of pressure got relative temperature which can help you more convenient for refrigeration system installation or servicing. THANKS FOR USING OUR PRODUCTS! Features * Pressure and vacuum mode shift function * build-in 82 refrigerants according to U.S.A. NIST stardard refrigerants pressure and temperature relationship database. * Real-time vacuum pressure test and percent indicate * Low power indicate. Batteries life:30H. 9V. > Pressure units:KPa,Bar,Psi, Torr,Kg F/cm2,InHg,MmHg * Temperature units:°F, ‘C * Test range: Measurement of vacuum: - 101 Kpa ~ 0 Kpa Positive pressure: 0 Kpa ~ 6Mpa Refrigerant: — 101 Kpa ~ 4 Kpa Used For WK-688 1H, WK688 1L,6882,6884 * Resolution: 1Kpa * Accuracy: +0.5% * Overload: 100Bar, 10Mpa % Operating temp.: -20°C~60°C Digital Gauge Frame Drawing Peers Defanit Refrigerants Status vacuum status/positive pressure status Function introduction 1. LD. Refrigerants Select'+" ». Hold: fast select 2. Power On/Off 3. @). Press to"ZERO" 2. Hold 2Sec To Shift Pressure / Vacuum Mode 4. LCD Display 5. Pressure/Temperatures Units (2). Hold 2sec Background Ligt On/Off 6. @. Refrigerants Select'-" (2). Hold: fast select 7. Pressure sensor Single digital manifold vacuumize operation instruction: 1.press "ON/OFF" button to turn on the manifold. hold "UNIT" button 2 seconds to turn on back light. 2.hold "ZERO" button 2 seconds shift to vacuum mode "LIAL". 3.connect air-condition systerm,digital manifold and vacuum pump as shown in figure. 4.after open the digital manifold valve,press 'ZERO'button to zero cleaning. 5.vacuumize. note:according to vacuumize result of 13L cylinder, LCD display "UAL 97%", "LIFAIE98% " after 3~5 minutes vacuumized. higher percent means higher vacuum degree. 6.checking the LCD display pressure results, if pressure results are stable, that means there are no gas leak in refrigeration system and connections. if pressure results rising, that means somewhere is leaking in refrigeration system or connections. it should be maintained. 7.after vacuumize work finished, close manifold valve, remove vacuum pump, press "ON/OFF" to turn off the gauge. Vacuumize Refrigeration system Vacuum pump Single digital manifold refrigerant charging operation instruction: 1.press "ON/OFF" button to turn on the manifold and hold for 2 seconds to turn on back light. 2.press "Rt" or "R-" to select refrigerants. Note: hold "R+" or"R-" to fasten the selection. 3.press "UNIT" to select pressure and temperature unit. 4.connect cylinder, air-conditioin system and single digital manifold as shown in figure. 5.press "ZERO" button to zero cleaning 6. open the digital manifold valve, cylinder valve, starting refrigeration system in order. 7.after refrigerant charging finished, close cylinder valve,digital manifold valve and remove charging hoses. 8. press "ON/OFF" button, turn off the gauge. oS © Charging Refrigerant Refrigeration system 2 valve digital manifold operation instruction: 1. The Operation method of refrigeration system vacuumize 1.1.press "ON/OFF" button to turn on the low digital gauge(blue). hold "UNIT" button 2 seconds to turn on background light 2.Hold "ZERO" button 2 seconds to switch the vacuum mode "HAL" 3.Connect air-condition systerm, digital manifold and vacuum pump as shown in Fig 4.After open the manifold valve, press 'ZERO' button to zero cleaning. 5.vacuumize. note:according to vacuumize result of 13L cylinder, LCD display "UALS7 %""" LAL98 % " after 3~5 minutes vacuumized. higher percent means higher vacuum degree. 6.checking the LCD display pressure results, if pressure results are stable, that means there are no gas leak in refrigeration system and connections. if pressure results rising, that means somewhere is leaking in refrigeration system or connections. it should be maintained. 7.after vacuumize work finished, close the manifold valve, remove vacuum pump, press "ON/OFF" button to turn off gauges. operation finished. Vacuumize Vacuum pump 2. After vacuumized,charging refrigerant as followed: 1.Connect Cylinder, air-condition systerm and digital gauges as shown in figure. 2.Press "ON/OFF" button to turn on digital gauges(blue and red) hold "UNIT" button 2 seconds to turn on back light 3.Press "R+" or "RE-" button to select the corresponding refrigerant type,2 digital gauges select same refrigerant type Note:hold "R+" or "R-" to fasten the selection. 4.Press "UNIT" button to select pressure and temperature units. 5.Press 'ZERO' button to zero cleaning 6.Open the left valve of digital gauge (blue), open the cylinder valve, start the refrigerant system. 7.After charging refrigerant, close the cylinder valve. 8.Open the right valve of digital gauge(red) to test the refrigeration system pressure. 9.close the manifold valves(blue and red) if the refrigeration system works normally,stop the refrigeration system,press "ON/ OFF" button to turn off the digital gauge switch. operation finished. oe © Charging Refrigerant Refrigeration system 4 valve digital manifold operation instruction: 1. The Operation method of refrigeration system vacuumize: 1.1.press "ON/OFF" button to turn on the low digital gauge(blue). hold "UNIT" button 2 seconds to turn on background light 2.Hold "ZERO" button 2 seconds to switch the vacuum table mode “UR 3.Connect air-condition systerm, digital gauges and vacuum pump and cylinder as shown in Fig 4.After turned on the manifold, press 'ZERO' to zero cleaning. 5..vacuumize. note:according to vacuumize result of 13L cylinder, LCD display "URO 97%", "L1AL98% " after 3~5 minutes vacuumized. higher percent means higher vacuum degree. 6.checking the LCD display pressure results, if pressure results are stable, that means there are no gas leak in refrigeration system and connections. if pressure results rising, that means somewhere is leaking in refrigeration system or connections. it should be maintained. 7.after vacuumize work finished, close the digital gauges valve, remove vacuum pump, press "ON/OFF" button to turn off gauges. Vacuumize Refrigeration system ac Vacuum pump 2. After vacuumized,charging refrigerant as followed: 1.Connect Cylinder, air-condition systerm and digital gauges. 2.Press "ON/OFF" button to turn on digital gauges(blue and red). hold "UNIT" button 2 seconds to turn on background light 3.Press "Rt" or "RE-" button to select refrigerant,select same refrigerant for the 2 digital gauges. Note:hold "R+" or "R-" to fasten the selection 4.Press "UNIT" button select pressure and temperature units. 5.Press 'ZERO' to zero cleaning 6.open the digital manifold valves (blue and yellow "REF"), open the cylinder valve, operating refrigerant system. 7.After charging refrigerant,close the cylinder valve and yellow valve "REF". 8.Open the right valve of digital manifold (red), test the refrigeration system pressure. 9.close the manifold valves(blue and red) if the refrigeration system works normally,stop the refrigeration system,press "ON/ OFF" button to turn off the digital gauge switch. operation finished. TECHNICAL DESCRIPTION Digital Gauges can be used for the following refrigerants: Liq=Liquid, Vap=Vapor 1Mpa=10Bar=10.1972kg/cm2= 145.038 Psi WK-688H Porc R410A-LIP Parone R410A-VAP. R410B-LIP R410B-VAP. R41LA-LIP R4LLA-VAP R4LIB-LIP R411B-VAP. R412A-LIP R412A-VAP R413A-LIP R413A-VAP R414A-LIP R414A-VAP R414B-L1P, R414B-VAP. R41SA-LIP R4I5A-VAP R415B-LIP R415B-VAP. 1_| RI34A RIB4A 52_[ R416A-LIP R416A-VAP 12 | RI4 RI4 53 | R417A-LIP R417A-VAP 13° | RI4IB RI4IB 54_[ R418A-LIP 14 | R142B RI2B 55_|R419A-LIP R419A-VAP 15 | RIA RIGA 56_|_R420A-LIP R420-VAP_ 16 | RIS2A R170 57_[_ R421A-L1P R421 A-VAP 17_| R170 RIS2A 58_ | R421B-LIP R421B-VAP 1g | RI RQ 59 | R422A-LIP R422A-VAP 19 | R28 R28 60_| R422B-LIP R422B-VAP 20 | R22 R22 61 | R422C-LIP R422C-VAP. 21 R23. R23 62 R422D-LIP R422D-VAP 22 | R290 R290 63 | _R423A-LIP R423A-VAP 23 [R32 R32 64 | R424A-L1P R424-VAP. 24 | RAO A-LIQ R4QLA-VAP 65_| _R425A-LIP RA25A-VAP 25 | RA0IB-LIQ R401B-VAP 66 | R426A-LIP R426A-VAP 26 | R40IC-LIQ R40IC-VAP 67_|_ R427A-LIP R4Q7A-VAP 27_ | R402A-LIQ R402A-VAP 68 | R428A-LIP R4Q8A- VAP 28 | R402B-LIQ R402B-VAP. 69 | R50 R50 29 | R403A-LIQ R403A-VAP 70_|_R500-LIP R500-VAP_ 30_ | R403B-LIP R403B-VAP T1_ | RS0I-LIP RSO1-VAP. 31_ [| R404A-LIP R404A-VAP 72_|~ R502-LIP R502-VAP_ 32_[ R405A-LIP R405A-VAP 73_|_R503-LIP R503-VAP, 33__| R406A-LIP 74_|~ R504-LIP R504-VAP, 34 | R407A-LIP 75_|_RSQ7A-LIP RSO7A-VAP 35_|_R407B-LIP R407B-VAP 76 | _R508A-LIP R508A-VAP 36 | R407C-LIP R407C-VAP. 77_|RS08B-LIP R508B-VAP. 37_|_R407D-LIP R407D-VAP. 78_|_RS09A-LIP R509A-VAP 38 | R408A-L1P R408 A-VAP, 79_| R600 R600 39 | R409A-LIP R409A-VAP 80 | R6OOA R6OOA 40_[_ R409B-LIP R409B-VAP 8i_|_ R717 RUI7 ai [Rat RAL g2_[ R744 R744 ACCESORIES WK-6881H/6881L @.WK-6881 digital manifold: 1 unit (2).red and yellow charging hose: 1 pcs each. (3).AD-89 adapter:1 pcs @.9V battery: 1 pcs WK-6882 (D.WK-6882 digital manifold: 1 unit ().red/blue/yellow charging hose: 1 pcs each. @.AD-89 adapter:2 pcs @.9V battery: 1 pcs WK-6884 (D). WK-6884 digital manifold: 1 unit @).red/blue/yellow/black charging hose: 1 pcs each. @.AD-89 adapter:2 pcs (4.9V battery: 1 pcs

You might also like