CHISON. ~~
EBit 50
WWW.CHISON.COMErgonomic Design
| need a portable,light-weight ultrasound which is
easy to go,easy to diagnose,easy to operate with
sufficient measurement packages.
Independent angle 15°LED
(0° -30°tited )
« Lightweight (7.5kg /16.5Ibs)
Dual transducer ports ( Built-in )
«Probe holders
«Removable battery , 120 minutes in active mode
- Theft-proof lock
-Dediceted adapter Space
-Printer socket
-Aocessory box
-Trolley height adjustable
(Three levels available)Auto IMT
Automatically traces the infima, and measures
the thickness of the intima. This allows you to
measure the intima faster, more easily and
more accurately.
Q-image
These innovative algorthms have strengthened the
image enhancement results significantly.
Advanced chipset is used to ensure fast frame rate
Up to 18MHz High
Frequency Linear Probe
(Our high frequency linear probe proves unparalleled detail
resolution and superior contrast resolution with up to 18 MHz
imaging frequency
Super Needle
With Super Needle, clinicians can see needle
Inside tissue more clearly during medical
procedures. Needle angle up to £30CCA, ICA, ECA, B Mode Popitteal Artery and Vein Fingertip Vessie, C Mode
Fingertip Vessle, PW Mode Knee , 48 Mode Elbow Joint, 48 Modered tothe traltional dual-beam former on mi ~ ~
nd machines, the EBit60 uses qua
for ultrasound signal receiving. ,
+ Doubles the volume of signals received from traditional 1 it
methods, increasing image resolution and generating more i ii
accurate images ‘ i
+ Produces higher frame rates, ensuring better d iostic a 7 — a
Traditional Dsl Beam EBRE0 Quad Beam
confidence and efficiency, especially for m«
ing organs.
Elastography displays tissue stiffness in real time to
provide doctors with additional diagnostic information
when scanning organs like liver and breast
FHI is an innovative harm
ic imaging technology that uses
multip ving methods based on the
patients’ size and weight. This allows the EBit to maintait
Image resolution when imaging larger patients.
+ Traditional Tissue Harmonics and Phased Harmonics
compromise image quality and resolution when penet
increased,
+ Chison's FHI technology grea
and clinical confidence in larger, di
ion is
FHI OFF
gnostic abilities
ly improves dia
ult-to-image patients.
HIP Grat Gallbladder stone, B Mode
Pancreas, B/BC Mode Umbilical cord, C Mode Aorta Artery, PW ModeDiagnostic Confidence
=
&
ee
2
ea cae,
Ore her eas)Liver, B Mode
occ n
Derm e
Aorta Artery, C Mode
rte Ree eR umd
Primary flexor tendon , 28 Mode
Se ued
Pree Remade’Specifications
+B, 28, 4B, 8/M
CFM
PW
PD, DPD(Direction Power Doppler)
Duplex, Triplex
. Trapezoidal
= Chroma B /M/ PW
. Super Needle ( option )
. 2D steer
+ Auto IMT
HIP Graf
= DICOM (option )
Image Processing
Technologies
+ FHI
+Q-beam
+ Q-flow
- Q-image
+ X-contrast
«SRA
« Compound Image
20-8 suite AD-SOMHe —7.0-18 0MHatWRh FHI)
Convene GE Linear L7-E LmoarLi2-€
40-120MHe 40-15 0H so1saMHe
Transvaginal VE-E Transvaginal V7-E Trars-Reci LIR-E
CHISON Medical Technologies Co., Ltd.
Sates & Service Contact Address:
N06. Xehutuan ead. Xr Dstt. i Fang, china 214028,
TEL: v0s6510 85510503) 85910057 FAX 0085:510-95910728 EMAIL : pot@ticen com.cn
Comprehensive Applications
+ OB/GYN
- Urology
- Pediatric
+ Radiology
+ Internal Medicine
«Small Parts
+ General Imaging
- Vascular
«Intensive Care
« Emergency
-MSK
Accessories
- Footswitch
«Trolley
- Suitcase
. Video Printer
= PC Printer
soscure issue
thew probes ray POE
‘| i&
ae \¢@
206.0 sora so107h
MecSonmehIChe Meant NCEE Meo Cone MERE
ereanetenito rat ange ih cate nto rr ct
EBit $0-20171025