You are on page 1of 3

Load rating chart ATF 80-4 Serial-No.

:
Lifting capacities in metric tons according to DIN 15019 part 2 / ISO 4305 / BS 1757 ed. 1981, at telescopic boom
Counterweight 12,7 t
On outriggers, 360° working area
Work. Outrigger base 7,20 m Work.
radius radius
(m) Boom length (m) (m)

10.8 14.6 14.6 18.3 18.3 18.3 18.3 22.1 22.1 22.1
° ° ° ° ° ° ° ° ° °
Ð Ð Ð Ð Ð Ð Ð Ð Ð Ð
2.5 ### 80,0* 2.5
3.0 ### 73.0 ### 68.0 ### 38.0 ### 58.0 ### 38.0 ### 58.0 ### 26.0 ### 47.0 ### 29.0 ### 22.0 3.0
3.5 ### 63.9 ### 63.6 ### 36.3 ### 58.0 ### 36.8 ### 54.9 ### 24.9 ### 45.0 ### 27.7 ### 22.0 3.5
4.0 ### 56.1 ### 56.0 ### 34.6 ### 55.0 ### 35.6 ### 51.7 ### 23.8 ### 42.9 ### 26.5 ### 22.0 4.0
4.5 ### 49.6 ### 49.5 ### 32.9 ### 48.6 ### 34.4 ### 47.8 ### 22.7 ### 40.9 ### 25.2 ### 21.4 4.5
5.0 ### 44.3 ### 44.3 ### 31.1 ### 43.4 ### 33.2 ### 42.6 ### 21.6 ### 38.9 ### 24.0 ### 20.9 5.0
6.0 ### 36.3 ### 36.3 ### 27.8 ### 35.5 ### 30.9 ### 34.8 ### 19.4 ### 34.8 ### 21.5 ### 19.7 6.0
7.0 ### 30.6 ### 30.6 ### 25.1 ### 29.8 ### 27.5 ### 29.1 ### 17.3 ### 29.2 ### 19.0 ### 18.6 7.0
8.0 ### 26.2 ### 26.2 ### 22.9 ### 25.4 ### 24.8 ### 24.8 ### 15.6 ### 24.9 ### 17.0 ### 17.4 8.0
9.0 ### 22.8 ### 21.1 ### 22.1 ### 22.6 ### 21.4 ### 14.2 ### 21.5 ### 15.5 ### 15.9 9.0
10.0 ### 20.1 ### 19.6 ### 19.3 ### 20.7 ### 18.6 ### 13.0 ### 18.8 ### 14.1 ### 14.5 10.0
11.0 ### 17.2 ### 18.5 ### 16.4 ### 19.1 ### 15.6 ### 12.1 ### 15.9 ### 13.0 ### 13.4 11.0
12.0 ### 14.9 ### 16.2 ### 14.1 ### 16.7 ### 13.4 ### 11.2 ### 13.6 ### 12.0 ### 12.4 12.0
14.0 ### 10.7 ### 13.1 ### 10.0 ### 9.8 ### 10.2 ### 10.4 ### 10.8 14.0
16.0 ### 8.3 ### 10.6 ### 7.6 ### 8.7 ### 7.8 ### 9.2 ### 9.6 16.0
18.0 ### 6.0 ### 8.2 ### 8.6 18.0
20.0 ### 4.7 ### 7.4 ### 6.9 20.0
22.0 22.0
24.0 24.0
26.0 26.0
28.0 28.0
30.0 30.0
32.0 32.0
34.0 34.0
36.0 36.0
38.0 38.0
40.0 40.0
42.0 42.0
44.0 44.0
Telescoping sequence %
Tel. 1 0 0 0 50 0 100 0 100 0 0 Tel. 1
Tel. 2 0 50 0 50 0 0 0 50 0 0 Tel. 2
Tel. 3 0 0 0 0 0 0 0 0 0 0 Tel. 3
Tel. 4 0 0 0 0 50 0 0 0 100 50 Tel. 4
Tel. 5 0 0 50 0 50 0 100 0 50 100 Tel. 5
Code 0 XX 02 0 0 15 02 0 0 10 02 0 0 16 02 0 0 11 02 0 0 05 02 0 0 01 02 0 0 15 02 0 0 10 02 0 0 09 02 0 Code
* Over rear with superstructure pin engaged and additional equipment, Code 0 01 02 5
The operation manual and the notes to the load rating chart have to be observed !
09.11.2001 99707788096 page 1 of 3
Load rating chart ATF 80-4 Serial-No.:
Lifting capacities in metric tons according to DIN 15019 part 2 / ISO 4305 / BS 1757 ed. 1981, at telescopic boom
Counterweight 12,7 t
On outriggers, 360° working area
Work. Outrigger base 7,20 m Work.
radius radius
(m) Boom length (m) (m)

25.9 25.9 25.9 29.7 29.7 29.7 33.5 33.5 33.5 33.5
° ° ° ° ° ° ° ° ° °
Ð Ð Ð Ð Ð Ð Ð Ð Ð Ð
2.5 2.5
3.0 3.0
3.5 3.5
4.0 ### 34.1 ### 27.5 ### 19.5 4.0
4.5 ### 33.2 ### 26.6 ### 19.0 4.5
5.0 ### 32.4 ### 25.8 ### 18.4 ### 27.0 ### 21.0 ### 18.0 5.0
6.0 ### 30.6 ### 24.0 ### 17.2 ### 25.4 ### 20.0 ### 17.3 ### 21.0 ### 21.0 ### 19.0 ### 15.6 6.0
7.0 ### 28.0 ### 22.3 ### 16.1 ### 23.9 ### 19.0 ### 16.6 ### 20.0 ### 20.0 ### 18.2 ### 15.0 7.0
8.0 ### 25.0 ### 20.5 ### 15.0 ### 22.3 ### 17.9 ### 15.9 ### 19.1 ### 19.1 ### 17.4 ### 14.4 8.0
9.0 ### 21.6 ### 18.8 ### 13.8 ### 20.8 ### 16.9 ### 15.2 ### 18.1 ### 18.1 ### 16.6 ### 13.8 9.0
10.0 ### 18.9 ### 17.1 ### 12.7 ### 19.2 ### 15.9 ### 14.5 ### 17.1 ### 17.2 ### 15.8 ### 13.2 10.0
11.0 ### 16.1 ### 15.7 ### 11.8 ### 16.5 ### 14.7 ### 13.4 ### 16.1 ### 16.2 ### 15.1 ### 12.5 11.0
12.0 ### 13.8 ### 14.4 ### 10.8 ### 14.2 ### 13.4 ### 12.4 ### 14.7 ### 14.5 ### 14.3 ### 11.9 12.0
14.0 ### 10.4 ### 12.4 ### 9.3 ### 10.8 ### 11.6 ### 10.7 ### 11.2 ### 11.1 ### 12.7 ### 10.7 14.0
16.0 ### 8.0 ### 10.7 ### 8.2 ### 8.3 ### 10.1 ### 9.5 ### 8.8 ### 8.6 ### 10.3 ### 9.5 16.0
18.0 ### 6.2 ### 8.8 ### 7.3 ### 6.5 ### 8.9 ### 8.4 ### 7.0 ### 6.8 ### 8.4 ### 8.4 18.0
20.0 ### 4.8 ### 7.3 ### 6.5 ### 5.2 ### 7.5 ### 7.6 ### 5.6 ### 5.4 ### 7.0 ### 7.5 20.0
22.0 ### 3.7 ### 6.2 ### 5.9 ### 4.1 ### 6.4 ### 6.7 ### 4.5 ### 4.3 ### 5.8 ### 6.7 22.0
24.0 ### 3.2 ### 5.5 ### 5.8 ### 3.6 ### 3.4 ### 4.9 ### 5.8 24.0
26.0 ### 2.5 ### 4.7 ### 5.1 ### 2.9 ### 2.7 ### 4.2 ### 5.0 26.0
28.0 ### 2.3 ### 2.1 ### 3.6 ### 4.4 28.0
30.0 ### 1.7 ### 1.6 ### 3.0 ### 3.8 30.0
32.0 32.0
34.0 34.0
36.0 36.0
38.0 38.0
40.0 40.0
42.0 42.0
44.0 44.0
Telescoping sequence %
Tel. 1 100 0 0 100 0 0 100 100 0 0 Tel. 1
Tel. 2 100 0 0 100 0 0 100 100 100 0 Tel. 2
Tel. 3 0 100 0 50 100 50 50 100 100 100 Tel. 3
Tel. 4 0 50 100 0 100 100 50 0 50 100 Tel. 4
Tel. 5 0 50 100 0 50 100 0 0 50 100 Tel. 5
Code 0 04 02 0 0 11 02 0 0 01 02 0 0 14 02 0 0 10 02 0 0 08 02 0 0 13 02 0 0 03 02 0 0 11 02 0 0 01 02 0 Code

The operation manual and the notes to the load rating chart have to be observed !
09.11.2001 99707788096 page 2 of 3
Load rating chart ATF 80-4 Serial-No.:
Lifting capacities in metric tons according to DIN 15019 part 2 / ISO 4305 / BS 1757 ed. 1981,
at telescopic boom
Counterweight 12,7 t
On outriggers, 360° working area
Work. Outrigger base 7,20 m Work.
radius radius
(m) Boom length (m) (m)

37.3 37.3 37.3 41.0 41.0 41.0 44.8 44.8 48.5


° ° ° ° ° ° ° ° °
Ð Ð Ð Ð Ð Ð Ð Ð Ð
2.5 2.5
3.0 3.0
3.5 3.5
4.0 4.0
4.5 4.5
5.0 5.0
6.0 6.0
7.0 ### 16.0 ### 15.0 ### 13.0 ### 12.5 ### 12.8 ### 11.0 7.0
8.0 ### 15.4 ### 14.5 ### 12.7 ### 12.5 ### 12.8 ### 11.0 ### 10.0 ### 9.2 8.0
9.0 ### 14.8 ### 13.9 ### 12.4 ### 12.5 ### 12.8 ### 11.0 ### 10.0 ### 9.2 ### 8.6 9.0
10.0 ### 14.2 ### 13.4 ### 12.0 ### 12.1 ### 12.5 ### 10.7 ### 10.0 ### 9.2 ### 8.6 10.0
11.0 ### 13.6 ### 12.9 ### 11.7 ### 11.7 ### 12.1 ### 10.5 ### 9.8 ### 9.1 ### 8.6 11.0
12.0 ### 13.0 ### 12.4 ### 11.4 ### 11.3 ### 11.8 ### 10.2 ### 9.6 ### 9.0 ### 8.6 12.0
14.0 ### 11.5 ### 11.3 ### 10.8 ### 10.5 ### 11.1 ### 9.7 ### 9.1 ### 8.7 ### 8.3 14.0
16.0 ### 9.0 ### 10.3 ### 10.1 ### 9.4 ### 9.3 ### 9.2 ### 8.7 ### 8.5 ### 7.9 16.0
18.0 ### 7.2 ### 8.6 ### 9.1 ### 7.6 ### 7.5 ### 8.6 ### 7.8 ### 8.2 ### 7.6 18.0
20.0 ### 5.8 ### 7.2 ### 7.6 ### 6.2 ### 6.1 ### 7.4 ### 6.4 ### 7.0 ### 6.7 20.0
22.0 ### 4.7 ### 6.0 ### 6.5 ### 5.1 ### 5.0 ### 6.3 ### 5.3 ### 5.9 ### 5.6 22.0
24.0 ### 3.8 ### 5.1 ### 5.6 ### 4.2 ### 4.1 ### 5.4 ### 4.4 ### 5.0 ### 4.7 24.0
26.0 ### 3.1 ### 4.4 ### 4.8 ### 3.4 ### 3.3 ### 4.6 ### 3.6 ### 4.2 ### 3.9 26.0
28.0 ### 2.4 ### 3.7 ### 4.2 ### 2.8 ### 2.7 ### 4.0 ### 3.0 ### 3.6 ### 3.3 28.0
30.0 ### 1.9 ### 3.2 ### 3.6 ### 2.3 ### 2.2 ### 3.4 ### 2.5 ### 3.1 ### 2.8 30.0
32.0 ### 1.4 ### 2.7 ### 3.1 ### 1.8 ### 1.7 ### 3.0 ### 2.0 ### 2.6 ### 2.3 32.0
34.0 ### 1.0 ### 2.3 ### 2.7 ### 1.4 ### 1.3 ### 2.6 ### 1.6 ### 2.2 ### 1.9 34.0
36.0 ### 1.1 ### 1.0 ### 2.2 ### 1.3 ### 1.8 ### 1.5 36.0
38.0 ### 0.7 ### 0.6 ### 1.9 ### 1.0 ### 1.5 ### 1.2 38.0
40.0 ### 0.7 ### 1.2 ### 0.9 40.0
42.0 ### 1.0 ### 0.7 42.0
44.0 ### 0.5 44.0
Telescoping sequence %
Tel. 1 100 0 0 100 100 0 100 50 100 Tel. 1
Tel. 2 100 100 50 100 100 100 100 100 100 Tel. 2
Tel. 3 100 100 100 100 100 100 100 100 100 Tel. 3
Tel. 4 50 100 100 50 100 100 100 100 100 Tel. 4
Tel. 5 0 50 100 50 0 100 50 100 100 Tel. 5
Code 0 12 02 0 0 10 02 0 0 07 02 0 0 11 02 0 0 02 02 0 0 01 02 0 0 10 02 0 0 06 02 0 0 01 02 0 Code

The operation manual and the notes to the load rating chart have to be observed !
09.11.2001 99707788096 page 3 of 3