Professional Documents
Culture Documents
Advancing Your Network: ADVC Controller Range
Advancing Your Network: ADVC Controller Range
Physical specifications
Advancing Your Network
Controller weight
Cubicle height
COMPACT
30kg
730mm
ULTRA
34kg
960mm
ADVC Controller Range
Cubicle width 420mm 450mm
Cubicle depth 302mm 302mm
Cubicle material 304 stainless steel 316 stainless steel
Customer compartment size 70 x 270 x 200 70 x 270 x 200 &
[mm] 260 x 280 x 200
COMPACT/ULTRA
Battery
Battery type (sealed lead-acid) 2 x 12V DC
Battery capacity 7Ah
(12Ah option on ULTRA)
Battery hold up time with panel off and without 26 hours with 7Ah
communications devices or heater at 25°C (44 hours with 12Ah)
Capacity available for communications hold up time (Panel 20 hours
off, no heater or IOEX 13.8V TX: 2.1A, 15min, RX 320mA)
Battery recharge time
7Ah battery from new to 80% nominal capacity 9.5 hours
12Ah battery from new to 80% nominal capacity 13.5 hours
Battery replacement interval 5 years (Influenced by
environment)
Radio/modem
Radios or modems may be fitted for remote communications. Space, power and data
interfaces are provided within the control cubicle.
Radio/modem power supply voltage 5 - 15V DC
Radio/modem power supply current 3A cont, 8A peak
Radio/modem power supply shutdown time 1 - 1440mins
Radio/modem interface V23, RS232, RS485,
Ethernet
Control electronics
Continuous primary current 800A
Short time primary current 16kA for 3 secs, 2000:1 CT
Short time current recovery time 60 secs
Required auxiliary supply rating 100VA
Other
Earthing 10mm earth stud
Nu-Lec Industries Corporate office & USA office As standards, specifications and designs change from time to
factory Nu-Lec LLC time, please ask for confirmation of the information given in
Locked Bag 10, 80 Schneider Rd, c/- Square D services this publication.
Eagle Farm Business Centre, Eagle Farm, 2979 Pacific Drive
Qld 4009 Qld 4009 Suite E
Norcross, GA 30071
USA
ADVC2-1164
Measurement
flexVUE Interface (pictured right)
Voltage, current, and frequency measurement
A flexible interface, with 20 configurable status Sequence component monitoring (both V & I)
lamps and 12 configurable Quick Action Keys,
Total power (kW, kVA, kVAR) and power factor
allows you to check your switchgear’s status
instantly. Per phase power and power factor
Power quality toolkit:
Additional information and Operator Menus are
Real-time waveform capture
displayed on the 2 × 20 character LCD, and
Extensive harmonic analysis
Trip/Close buttons allow user switchgear control.
ADVC ULTRA with flexVUE Interface
Sag and surge monitoring
Supply outage monitoring
Ensuring Reliability
Extra Power Battery Backup flexVUE interface
Allowing natural airflow, the ventilated Up to 44 hours* battery hold up time without 20 × Status Lamps:
Auxiliary power, including
g an optional courtesy
Indicates protection and controller status
cubicles are made from hard wearing outlet, is easily accessed with a power supply unit power. 2 × 12V lead-acid batteries (at base
Logic & colour (Red, Green or Orange) are user
304 or 316 Stainless Steel. This, e. Transformers, breakers
at the base of the cubicle of cubicle) provide up to 5 years trouble free configurable for each lamp
combined with constant system health and terminals are availabble for auxiliary power operation. Both controllers offer 7Ah batteries, and 12 × Quick Action Keys (QAK):
connection, and all wiring
g is protected by a safe the ULTRA also offers optional 12Ah batteries for
Buttons to execute frequently used actions
monitoring and IP65 rated electronics IP20-rated removable covver. A silicone rain-shield longer hold up, and heater, for operation to -40ºC.
User configurable actions and LED indication
enclosure, ensure excellent reliability. also covers the miniaturee circuit breakers. * ADVC ULTRA with 12Ah Batteries. 26 Hrs with 7Ah Label Inserts to identify each Lamp & QAK