Orifice calculation for Bore size - Flange Taps - Gas

Customer: Seplat
Tag: FG to AG

Flow Rate 500,000.00 Standard Cubic Feet/Day


Differential Pressure 150.00 mbar
Operating Temperature 20.00 Deg C
Operating Pressure 8.00 bar (gauge)
Base Specific Gravity 0.66
Compressibility Factor:
Zf 0.96560

Pipe Diameter 3.826 Inches


Bore Diameter (approximate) 0.967 Inches
Beta (approximate) 0.25267

Note: Values for the beta ratio are approximate, typically within
2% - 5% for gases and steam
1% for liquids
The ASME MFC-3M 1989 equation is used in this program. However,
several equation factors are assumed and can directly affect the
calculation results
Coefficient of Thermal Expansion: 1.0
Discharge Coefficient: 0.6
Base Temperature: 60 Deg F (15.56 Deg C)
Base Pressure: 14.7 PSIA (101.3 kPa-A)
Pressure Tap Location: Flange Tap

Also, this program does not take into consideration two calculation
variables - the Reynolds Number correction and the expansion factor.

If it is necessary to have a closely specified beta ratio, differential


pressure, or flow rate, please consult your Daniel representative for
assistance

Daniel Division Headquarters Calgary, Alberta, Canada Swinton Grange, England Singapore
Houston, Texas, USA Tel:(403)279-1879 Tel:+44(0)1653-638300 Tel:+65-777-8211
Tel:(713)467-6000 Fax:(403)236-1337 Fax:+44(0)1653-600425 Fax:+65-770-8031
Fax:(713)827-3880

visit our web site at www.daniel.com 01 Jul 2022