You are on page 1of 3
INSPECTION WORKSHEET (IBLI Cedar Rapids, 1A Phone: 319-286-5831 Address: 500 15th Ave SW, Cedar Rapids, lowa 52404 Case Number: BLDC-011956-2021 Case Module: Permit Inspection Date: Mon Apr 17, 2023 Inspection Status: Partial Pass Inspector: Lough, Inspection Type: Rough-In Electrical Job Address: 501 4TH AVE SE Parcel Number: 142148900800000 Cedar Rapids, 1A, 52403 Contact Type Company Name Name Plumbing Contractor SCHRADER EXCAVATING & SCHRADER, SHANE GRADING CO Plumbing Contractor RICH PLUMBING INC OF IOWA Applicant LA PRES, KERRY Property Owner LLe, 5000 Contractor ‘TWG CONSTRUCTION LLC Mechanical Contractor FLEETWASH INC DBA WELKER WELKER, LUKE HEATING & COOLING Electrical Contractor NOVAK ELECTRIC, INC. Novak, Wendy Checklist Item Status General Review - General Review Passed 3rd floor area 3 ok Lough, C ‘apr 17, 2023 Page (1) INSPECTION WORKSHEET (IACB-063458-2023) Cedar Rapids, 1A Phone: 319-286-5831 Address: 500 15th Ave SW, Cedar Rapids, lowa 52404 Case Number: BLDC-011956-2021 Case Module: Permit Inspection Date: Mon Apr 17, 2023, Inspection Status: Partial Pass Inspector: Carson, Daryl Inspection Type: Above Ceiling Building Job Address: 501 4TH AVE SE Parcel Number: 1421489008000 Cedar Rapids, 1A, 52403, Contact Type Company Name Name Electrical Contractor NOVAK ELECTRIC, INC. Novak, Wendy Plumbing Contractor SCHRADER EXCAVATING & SCHRADER, SHANE GRADING CO Applicant LAPREES, KERRY Contractor ‘TWG CONSTRUCTION LLC Plumbing Contractor RICH PLUMBING INC OF IOWA Property Owner LLe, 5000 Mechanical Contractor FLEETWASH INC DBA WELKER WELKER, LUKE HEATING & COOLING Checklist Item Status General Review - General Review Failed STAIR 1 and area 3 stairwell 1) rock under stairs at lower level to compartmentalize for fire stopping 2) remove stair stringer spacer to allow 2 layers to be applied on walls of interior side of stairs 3rd and 2nd floor area 3 exterior walls ok Carson, Day ‘ape 17,2023, Page (1) INSPECTION WORKSHEET (IBLD-063572-2023) Cedar Rapids, 1A Phone: 319-286-5831 Addre: 500 15th Ave SW, Cedar Rapids, lowa 52404 Case Number: BLDC-011956-2021 Inspection Date: Tue Apr 18, 2023, Inspector: Pump, Lucas Case Module: Permit Inspection Status: Failed Inspection Type: Rough-In Framing Job Address: 501 4TH AVE SE Parcel Number: 142148900800000 Cedar Rapids, 1A, 52403, Contact Type Plumbing Contractor Contractor Applicant Property Owner Plumbing Contractor Electrical Contractor Mechanical Contractor Company Name Name SCHRADER EXCAVATING & SCHRADER, SHANE GRADING CO ‘TWG CONSTRUCTION LLC LA PREES, KERRY LLe, 5000 RICH PLUMBING INC OF IOWA NOVAK ELECTRIC, INC, Novak, Wendy FLEETWASH INC DBA WELKER, WELKER, LUKE HEATING & COOLING Checklist item General Review - General Review ‘rd Floor - Area 3: Status Failed +1) Firestopping needed at ceiling of concealed combustible space, plumbing dead spaces, space adjacent to elevator. 2) Plumbing water lines penetrations need fire stopped. “Ok to insulate Pump, Lucas ‘Apr 18, 2023 Paget)

You might also like