Exposing 10 Common Misunderstandings

about Penetrant Testing


We reveal common penetrant inspection
misperceptions we’ve seen in the field in recent years
By Cheri Stockhausen, Product Applications Manager

The liquid penetrant method of nondestructive testing has been used since the 1940’s. But
even after being used by generations of NDT professionals, there are still some common areas
of confusion or misunderstanding.

Here we set the record straight on 10 misperceptions we’ve seen in the field in recent years.

1. The highest sensitivity penetrant is the best penetrant for my


application
The best penetrant for an application is the one that finds the right indications with the least
amount of money and time. Sometimes this means not using the highest sensitivity penetrant.

While it is true that a higher sensitivity penetrant will produce indications for very small
discontinuities, a higher sensitivity penetrant will probably not give you the best inspection
results if you only need to find medium discontinuities since you will see far more indications
than are relevant to the inspection.

To start selecting a penetrant, review any governing specifications and work procedures for
required sensitivity levels.

Take into consideration the surface finish and configuration of the part.

A high sensitivity level fluorescent penetrant is appropriate for smooth, highly machined
surfaces. However, a high sensitivity level fluorescent penetrant may leave excessive
fluorescent background on a rough cast part, making inspection difficult.

A lower sensitivity fluorescent penetrant is a better choice for rough surfaces.

2. A penetrant indication is a discontinuity


A penetrant indication is the visual results or response of the penetrant test which must be
interpreted to determine its relevance.

Penetrant indications must be evaluated by a qualified inspector to determine if they are


nonrelevant or relevant.

Nonrelevant indications may be present on parts because of inherent surface roughness or


seams. Fingerprints or fibers may also cause nonrelevant indications.

Relevant indications are the result of a discontinuity, or interruption in the physical structure of
an object, and are evaluated according to acceptance criteria. After evaluation, the part is
accepted as is, reworked or discarded.

3. Water washable penetrants are water based


Some water washable penetrants are water based. However, this is not always the case. A
penetrant can be water washable and not contain water.

Water-washable penetrants contain surfactants which allow the penetrant to be easily removed
from the part surface with water rinsing, regardless of if they are water-based or oil-based.
4. Penetrants are only used on nonferrous metals
Penetrants can be used to inspect ferrous and nonferrous metals.

Penetrant inspection will find discontinuities open to the surface on ferrous and nonferrous
metals.

Penetrant testing should not be done on porous surfaces, as the pores will act as
discontinuities to trap penetrant and prevent accurate inspection.

5. Penetrant will be able to penetrate a discontinuity that


contains water
Penetrant cannot seep into a discontinuity if it is already filled with water or other liquid.

Likewise, penetrant will not displace or penetrate through paint, particulate, oil or grease.

This is one of the reasons why an important prerequisite for a valid penetrant inspection is to
start with properly cleaned and dried parts.

6. Tanks and an inspection booth are required for penetrant


inspection
Penetrant inspection is easy to adapt to different environments and job sites.

Penetrant inspection systems with stationary tanks and booths are commonly seen in
production environments. However, both fluorescent and visible dye penetrants are available in
aerosol cans and kits for convenience and portability.

Check out our Penetrant Process Guide for a visual reference


outlining each step in the various penetrant inspection methods
and to learn 5 tips for penetrant testing

7. Penetrant is all that is needed to perform a penetrant


inspection
At a minimum, penetrant and developer are required to perform a water washable penetrant
inspection.

Additional products such as cleaner/removers and emulsifiers are required for solvent
removable and post emulsifiable penetrant inspections.
8. Special lighting is required for penetrant inspection
Fluorescent penetrants do require inspection in a darkened area with specification compliant
UV lighting. The UV lights may be mounted or hand-held for flexibility and portability.

Visible dye penetrants only require adequate white light, typically 100 foot candles minimum,
for inspection.

9. Penetrant inspection should be the final check in a


manufacturing process
Penetrant inspection is useful immediately after any manufacturing process which is known to
cause discontinuities. This allows parts to be reworked or discarded earlier in the
manufacturing process, which saves time and cost.

Penetrant inspection may sometimes be performed more than once during the manufacture of
a part.

The placement of each penetrant inspection process should be optimized to locate


manufacturing-induced discontinuities and reduce the amount of scrap or rework done later in
the manufacturing process.

10. Penetrant inspection can take place at any point in the


manufacturing process
As discussed, it is important to perform penetrant inspection after manufacturing operations
likely to cause discontinuities open to the surface in parts.

However, care must be taken to perform penetrant inspection prior to mechanical operations
that will smear the metal surface. Machining operations such as shot blasting, peening or
grinding may close surface discontinuities, which can prevent subsequent penetrant
inspections from finding these discontinuities.

Penetrant inspection should take place before machining operations like shot blasting, peening
or grinding unless chemical etching can be used between these operations and the penetrant
testing to reliably expose the discontinuities.

Want to stay up on the latest NDT insights and articles from


Magnaflux? Subscribe to Magnaflux updates get fresh news
delivered to your inbox.

RELATED BLOG POSTS

What Do I Do If My Penetrant How to Do Visible Dye Penetrant


Freezes!? Testing [Video]
Discover what mixing or testing could be Watch an overview of the dye penetrant
required to return a penetrant to its testing method according to ASTM E1417,
original state once it has frozen including basic steps for NDT with an
AMS 2644 Type 2 penetrant.