The liquid penetrant method of nondestructive testing has been used since the 1940’s. But
even after being used by generations of NDT professionals, there are still some common areas
of confusion or misunderstanding.
Here we set the record straight on 10 misperceptions we’ve seen in the field in recent years.
While it is true that a higher sensitivity penetrant will produce indications for very small
discontinuities, a higher sensitivity penetrant will probably not give you the best inspection
results if you only need to find medium discontinuities since you will see far more indications
than are relevant to the inspection.
To start selecting a penetrant, review any governing specifications and work procedures for
required sensitivity levels.
Take into consideration the surface finish and configuration of the part.
A high sensitivity level fluorescent penetrant is appropriate for smooth, highly machined
surfaces. However, a high sensitivity level fluorescent penetrant may leave excessive
fluorescent background on a rough cast part, making inspection difficult.
Relevant indications are the result of a discontinuity, or interruption in the physical structure of
an object, and are evaluated according to acceptance criteria. After evaluation, the part is
accepted as is, reworked or discarded.
Water-washable penetrants contain surfactants which allow the penetrant to be easily removed
from the part surface with water rinsing, regardless of if they are water-based or oil-based.
4. Penetrants are only used on nonferrous metals
Penetrants can be used to inspect ferrous and nonferrous metals.
Penetrant inspection will find discontinuities open to the surface on ferrous and nonferrous
metals.
Penetrant testing should not be done on porous surfaces, as the pores will act as
discontinuities to trap penetrant and prevent accurate inspection.
Likewise, penetrant will not displace or penetrate through paint, particulate, oil or grease.
This is one of the reasons why an important prerequisite for a valid penetrant inspection is to
start with properly cleaned and dried parts.
Penetrant inspection systems with stationary tanks and booths are commonly seen in
production environments. However, both fluorescent and visible dye penetrants are available in
aerosol cans and kits for convenience and portability.
Additional products such as cleaner/removers and emulsifiers are required for solvent
removable and post emulsifiable penetrant inspections.
8. Special lighting is required for penetrant inspection
Fluorescent penetrants do require inspection in a darkened area with specification compliant
UV lighting. The UV lights may be mounted or hand-held for flexibility and portability.
Visible dye penetrants only require adequate white light, typically 100 foot candles minimum,
for inspection.
Penetrant inspection may sometimes be performed more than once during the manufacture of
a part.
However, care must be taken to perform penetrant inspection prior to mechanical operations
that will smear the metal surface. Machining operations such as shot blasting, peening or
grinding may close surface discontinuities, which can prevent subsequent penetrant
inspections from finding these discontinuities.
Penetrant inspection should take place before machining operations like shot blasting, peening
or grinding unless chemical etching can be used between these operations and the penetrant
testing to reliably expose the discontinuities.