P-4 P-3 P-2 P-1

15000

200 1500 200 7400 200 1500 200 3600 200


200

200
800x800 800x800 800x800 800x800 800x800 800x800 800x800 800x800
MH MH MH MH MH MH MH MH

1760
2000

FOG TANK FOG TANK

1000 1000

200
200

800x800 800x800
MH IO- TANK 2 MH IO- TANK 2

1760
AOP TANK AOP TANK
2000

FOG TANK FOG TANK

1000 1000

200
200

EQUALIZATION TANK EQUALIZATION TANK


800x800 800x800
10000

10000
1760
MH MH

AOP TANK AOP TANK


800x800 800x800
MH MH
2000

FOG TANK FOG TANK


1000 1000

200
200

1760

700
CONCRETE PAD
AOP TANK
1500

IO- TANK 1
1000

200
BAR SCREEN

3500
500

4700

1760
800x800 800x800 800x800 800x800 800x800 800x800
MH MH MH MH MH MH
1000

700
CONCRETE PAD
200

200
INFLUENT
300 1000 1050 1500 1050 1500 1050 1500 1050

10000
P-4 P-3 P-2 P-1

TOP VIEW TOP VIEW


STP CHAMBER & PIPING LAYOUT STP CHAMBER & PUMP ROOM LAYOUT
P-01
01 SCALE: NTS: MILLIMETERS:
P-01
02 SCALE: NTS: MILLIMETERS:

PROJECT TITLE: SANITARY ENGINEER: OWNER/DEVELOPER: CHECKED BY: SHEET CONTENT: SHEET NO:

AS SHOWN
J.N. WATER TREATMENT
IT SHALL BE UNLAWFUL FOR ANY
P-01
AND SUPPLY SERVICES PRC NO: PTR NO: DRAFTED BY: VACKZ
PERSON WITHOUT WRITTEN
CONSENT OF THE ARCHITECT, THE

LOCATION: PRC DATE: PTR DATE: ADDRESS: DATE:


AUTHOR OF SAID DOCUMENTS TO
DUPLICATE OR MAKE COPIES OF
THE SAID DOCUMENTS FOR THE
USE IN THE REPETITION OF
01 03
AND OTHER PROJECT OR BUILDING
TIN: PTR LOCATION: REVISION: WHETHER EXECUTED PARTLY OR IN WHOLE 762mm X 508mm

JUNE 27, 2022


300 800 7800 800 300

150
2550
3000
AOP TANK AOP TANK AOP TANK AOP TANK AOP TANK

300
200 1760 200 1760 200 1760 200 1760 200 1760 200

10000

SECTION V I E W - P-1
STP CHAMBER & PIPING LAYOUT
P-02
01 SCALE: NTS: MILLIMETERS:

4000 800 4100 800 300


150
2550
3000

IO - TANK 1 IO - TANK 2
300

200 4700 200 4700 200

10000

SECTION V I E W - P-2
STP CHAMBER & PIPING LAYOUT
P-02
02 SCALE: NTS: MILLIMETERS:

PROJECT TITLE: SANITARY ENGINEER: OWNER/DEVELOPER: CHECKED BY: SHEET CONTENT: SHEET NO:

AS SHOWN
J.N. WATER TREATMENT
IT SHALL BE UNLAWFUL FOR ANY
P-02
AND SUPPLY SERVICES PRC NO: PTR NO: DRAFTED BY: VACKZ
PERSON WITHOUT WRITTEN
CONSENT OF THE ARCHITECT, THE

LOCATION: PRC DATE: PTR DATE: ADDRESS: DATE:


AUTHOR OF SAID DOCUMENTS TO
DUPLICATE OR MAKE COPIES OF
THE SAID DOCUMENTS FOR THE
USE IN THE REPETITION OF
02 03
AND OTHER PROJECT OR BUILDING
TIN: PTR LOCATION: REVISION: WHETHER EXECUTED PARTLY OR IN WHOLE 762mm X 508mm

JUNE 27, 2022


300 800 7800 800 300

150
2550
3000
EQUALIZATION TANK

300
200 9600 200

10000

SECTION V I E W - P-3
STP CHAMBER & PIPING LAYOUT
P-02
03 SCALE: NTS: MILLIMETERS:

300 800 3400 800 1400 800 1400 800 300


150

INFLUENT
1550

BAR SCREEN
3000
1000

500

500

500
FOG TANK FOG TANK FOG TANK
300

200 1000 500 1500 200 2000 200 2000 200 2000 200

10000

SECTION V I E W - P-4
STP CHAMBER & PIPING LAYOUT
P-02
04 SCALE: NTS: MILLIMETERS:

PROJECT TITLE: SANITARY ENGINEER: OWNER/DEVELOPER: CHECKED BY: SHEET CONTENT: SHEET NO:

AS SHOWN
J.N. WATER TREATMENT
IT SHALL BE UNLAWFUL FOR ANY
P-03
AND SUPPLY SERVICES PRC NO: PTR NO: DRAFTED BY: VACKZ
PERSON WITHOUT WRITTEN
CONSENT OF THE ARCHITECT, THE

LOCATION: PRC DATE: PTR DATE: ADDRESS: DATE:


AUTHOR OF SAID DOCUMENTS TO
DUPLICATE OR MAKE COPIES OF
THE SAID DOCUMENTS FOR THE
USE IN THE REPETITION OF
03 03
AND OTHER PROJECT OR BUILDING
TIN: PTR LOCATION: REVISION: WHETHER EXECUTED PARTLY OR IN WHOLE 762mm X 508mm

JUNE 27, 2022