Abe
Compressed Air Safety Lights
Specification
ALLK-TL45
WWW.ALL-KMARINE.COM‘aL
sewnee
ALLK-TL45 is the new generation of high powered compressed air
driven lighting. The light is certified for use in zones 1 and 2 hazardous
areas. Common applications are in the Oil and Petrochemicals Industries,
for tank cleaning and pipeline inspections, offering a safer alternative to low
voltage lighting in dangerously wet conditions as well as where flammable
gases and vapours can accumulate in confined spaces
The housings of ALLK-TL45 are cast brass, a spark free material, and
the safety hook is also brass, but forged for extra strength. Most of external
parts are nickel plated. Internal components are of durable design making
the products suitable for use in the harshest industrial environments. A
clean dry air supply is a condition of certification and essential for the
efficient running of these lamps, otherwise contamination will deposit into
the inside of the lens, reducing illumination levels. Suitable air-line filters
can be supplied. Another mandatory requirement is the use of anti-static
hose, to prevent the generation of unsafe levels of static electricity.
The 24 volt 84 watt LED bulb is available. The life of LED bulb is more
than 30000hours. All items of spare paris including LED bulbs and
aiternative reflectors are readily available from stock
The lamps are routinely run in, tested and set to the necessary output
prior to despatch. The lamps are simple and easy to maintain. In-house
training on maintenance, setting and operation of air lamps is available.
WWW.ALL-KMARINE.COMTechnical Specification
Product raferenca:
{ire
ALLKTLAS
Product description
Compressed Air Safety Lights
Area of classification
(Gases)
Zones 1 and 2, Gas Groups IIA, IIB, 1IC
Ambient temperature “20°C to +60°C
Enclosure Nickel plated brass
Beam type Beam lamp
Light | Type LED
source: [Voits aay
‘Watts a4w
Output ca {8000 im
Lite > 30000 hrs
Power | Tyoe
Compressed air driven
source:
‘Air pressure 4080 bar
Consumption 03m" Fin
Ingress protection Per
Special certification ‘A.Gean dry a supply must be used
condi
Supply hose must be anti-static.
WWW.ALL-KMARINE.COMpe
thw ee
Please follow the below steps if you are going to change the bulb.
1, Release the blue cover of the groupware of the lighting source, move the lens
away then you will see and LED (yellow color).
2. There are two wires connected to the LED, one is yellow and the other is black.
‘The yellow wire is connected to the anode of the LED ( there is @ ‘+’ marked on the
LED), and the black wire is connected to the cathode of the LED (there is a
‘~ marked on the LED).
3. Release the wire from the old LED with an electric iron, and then release the four
‘screws from the lighting base, Then move the LED away.
4. Put the heat sink compound on the bottom of the new LED, and then put it on the
lighting base, fix it with the screw, and then weld the wire on the anode and the
cathode of the LED.
Note: Please don’t confuse the anode and cathode. Otherwise the lamp will not
work.
5. Cover the blue cover onto the light source.
WWW.ALL-KMARINE.COM