You are on page 1of 8
cobas off1 Software Chango Document Version 01-02 The Document of Software Change Notice 01-02 Model: cobas e 411 Version: 01-02 Date Aug. 07, 2007 UNdbachina = Z ! Y. Matsushima, Senior Engineer T. Suzuki, Seniér Engineer Life Science Software Systems Medical Systems Design 2™ Dep't Design Dep't Page 1or8 cobas e411 Software Change Document Version 01-02 CONTENTS 1 Dotails of cobas 0 411 Software Changes. 3 14 Revision Overview... 3 112 _ Outine of Revision. 3 2° Detail of changes... 4 2.4 Functions Update and improvements... 4 22 Bug and Problem Fixes... a 4 23 Hardware Related issues (already informed in 82-02) 4 2.4 — Wording/Term modification. n 4 28 Changes related to UI screens 4 2.8 Ondine HELP Information oe) 27 — Release Note... 5 28 SVP Version Information.. 6 2.9 _ Open Failure Reports 8 3 Contents of the install Ci 8 Page 20f8 ‘cobas 0411 Software Chango Document Version 01-02 1 Details of cobas e 411 Software Changes 1.1. Revision Overview 4.1.4 Instruments Affected: Serial No 0716-30 onward. 1.1.2 Effective Date: ‘Aug, 2007 1.2 Outline of Revision cobas ¢ 411 software was revised as follows. Version: 01-02 This version is created based on version C1-04 riser Program No. 7410850-C1-04 Program No. 7410850-01-02 Tolaifiles | Totalsize | Totalsum | Tolalfiles | Total size] Total sum [bytes] [bytes] 7,049,428 | 3696 3 7,049,428 3687 7 9,245,877 caté 7 9,245,811 cat Page 3of8 2 Detail of changes 2.1 Functions Update and Improvements NA <"> Startup screen was modified for commercial release. 2.2 Bug and Problem Fixes The following issue was implemented in 01-02 version, cobas e411 Software Change Document Version 07-02 2.3 Hardware Related issues (already informed In B2-02) PCICC front cover openiclose detection is realized and i’s active by default. Therefore, for not modified instruments, you will get an error message at reset movement and operation, etc. Please deactivate this function by deleting " in au¥SUSNNX file with a text editor like NotePad, ed "led t/au" 1d 1 <£2010.0ut sysClkRateSet 200 Dene #SipCoverNoCheck(); 41 ki 24 NIA Wording/Term modification 25 NA Changos related to UI screens 26 NA On-line HELP Information —> ed "lest 41 in System Overview screen (2) in Calibration: Install screen (8) in QC-Install screen (4) in Utlity-System screen 2) Buttons in Screens The following screen behavior related problems remain and to be fixed in the Upgrade software. (1) Data Review under the following conditions 4) "Operator level 2) Open other popup, like Filter and ‘comes back to this screen (2) Individual @C ‘After carrying out exclude , a confirmation popup still pops up when the shaded button is selected. Page Sof 8 cobas e411 Software Change Document Version 01-02 (3) QC Install Edit ‘Shaded button can be pressed and ‘a confirmation : "Some fields do not have an ceniry" pops up after assigning a test (for Non- RD control). ‘Shaded , buttons work under the following conditions. (Open Password Protection pop-up and comes back tots popup 2.8 SVP Version Information NIA (01-02 supports only auto backup function.) 2.9 Open Failure Reports ne mz G-e411-002 | Position assignment reset Final implementation of position ie assignment will be realized in the next ft version, so called “Upgrade SW". G-e417-003 | Delete calibration information Originally agreed to realize in so called : a “Upgrade SW". G-e411-005 | Adjustment results in data review | Automatic refresh of HV adjustment pop- t mixed up (during HV adjustment) | up will be realized in the next version, so Setkores oi called “Upgrade SW". G-e411-006 | Change in QC SD To be fixed in the next version, so called a “Upgrade SW". “G-6411-007- | QC selection interchanging To be fixed in the next version, so called “Upgrade SW". “G-e411-008 | Keyboard appears in help screen | The behavior is already recognized in the aes project of both sides. Final solutions should be discussed between RD/HHT. Page 6of8 cobas eff1 Software Change Document Version 01-02 G-0411-012 | Handling of Documentation and | To be fixed in the next version, so called | Printer setting “Upgrade SW" G-e411-014| QC points not plotting on the | Under investigation individual QC charts G-e411-016 | Delete calibration data Originally agreed to realize nso called “Upgrade SW”. Tentative solution should be discussed between RD/HHT. ‘QC level 1 not perform: Under investigation ‘Manual selection of a control Under investigation Page Tof8 cobas e411, Software Change Document Version 01-02 3 Contents of the install CD 1) cobas e 411 system software 2) Installer Page Bot

You might also like