0001:MAN-----> means service terminal is connected locally on computer unit.

-----
DMX UNITS

0001-MAN-----> means service terminal is connected remotely through NETACT. -----


DMX UNITS

0001-$ -------> CHORUS UNIT

E2K for Calls checking


__________________________

ZDDS:ICSU,0;
0000-MAN>ZLP:1,E2K
0000-MAN>1
0000-E2K>MCD:(WBTS NO),6;

===================================================================================
==============================================================

002D-E2K>CD:(WBTS NO),0,1; FOR DMCU IDENTIFYING

===================================================================================
===============================================================

HME HARDWARE MANAGEMENT

power shut down of Plug-in units-----> TO FIND THE RACK AND SHELF--ZWFI:PS;
________________________________

ZDDS;
0000-MAN>ZLP:H,HME
0000-MAN>H
0000-HME>DG:rack,subrack,ppa (2,2,C is Rack,Subrack,ppa detail) ALL SHOULD BE IN
HEX VALUE (ZWFI:PS;)

power shutdown executed


=====================
ZDDS;
0000-MAN>ZLP:H,HME
0000-MAN>H
0000-HME>DH:rack,subrack,ppa

Power feed executed


===================================================================================
===============================================================

power shut down of FAN TRAY


___________________________
ZDDS;
0000-MAN> ZLP:H,HME
0000-MAN>H
0000-HME>GA:rack,subrack,ppa

power shutdown of Fan tray executed


=================

ZDDS;
0000-MAN> ZLP:H,HME
0000-MAN>H
0000-HME>GB:rack,subrack,ppa

power feed of Fan tray executed


===================================================================================
=====================================================================

FAN ROTATION SPEED CHANGING


___________________________

ZDDS;
0000-MAN> ZLP:H,HME
0000-MAN>H

0000-HME>DJ:rack,subrack,ppa:level; DJ:1,1,A:1; DJ:1,2,A:1;

-level detials-------0 =fan off


1 =minimum
2 =normal
3 =full

===================================================================================
===========================================================================

RCB for Faulty Flag Clear


_______________________________

ZDDS;
0000-MAN>ZLP:2,RCB
0000-MAN>2
0000-RCB>TPP:NPGEP,3,C,FLTY; (if FLTY flag is set)

Faulty Flag Clear for DMCU units


________________________________
ZDDS;
0000-MAN>ZLP:2,RCB
0000-MAN>2
0000-RCB>TPP:DMCU,1,FULL,C,FLTY; (if FLTY flag is set)

TO SET ANY FAULTY FLAG


_______________________

ZDDS;
0000-MAN>ZLP:2,RCB
0000-MAN>2
0000-RCB>TPP:NPGEP,3,S,FLTY; (to set FLTY TAG in unit)

===================================================================================
============================================================================

TO TAKE BLACKBOX LOGS ON PARTICULAR UNIT(bblog)


_________________________________________

DDS:NPGEP,4:;

0061-$ loadext -l
0061-$ loadext bblog
0061-$ bblog man
0061-$ bblog -W

===================================================================================
===================================================================================
=

WBTS STATUS OF RNC WITHOUT OPENING ELEMENT MANAGER


___________________________________________________

ZDDS;
0000-MAN>ZLE:1,RUOSTEQX;
0000-MAN>1
0000-RUO>SA --------IT WILL SHOW ALL THE WBTS STATUS IN RNC WITHOUT OPENING
ELEMENT MANAGER.

===================================================================================
==================================================================================
TURNING ON TELNET CONNECTION IN MML COMMAND:

ZI2H:PROTOCOL=STTELNET;

IF TELNET IS NOT ENABLED PLS ENABLE THROUGH FOLLOWING COMMAND

ZI2T:TYPE=ST:IPV4STATE=ON,IPV4PORT=<port number>:IPV6STATE=OFF;

telnet <ip address of host name>:<port>;