Professional Documents
Culture Documents
Ebx 1
Ebx 1
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
==========================================================================
radioSettingsHelpers
==========================================================================
radioSettingsHelpers.frequencyMasksErrors
type:string
--------------------------------------------------------------------------
==========================================================================
encryption
==========================================================================
encryption.encryptionMode=AES_CTR
Encryption mode
type:uint32_t default:AES_CTR
options:["AES_CTR","AES_CCM"]
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.activeKey=Off
type:uint32_t default:Off
options:["Off","Key1","Key2","Key3","Key4",
"Key5","Key6","Key7","Key8","Key9",
"Key10","Key11","Key12","Key13","Key14",
"Key15","Key16"]
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key1=Key has not been set.
Manage Key1
USAGE - Key1=[128 or 256 key in hex]
example 128 bit key : Key1=1234567890abcdef1234567890abcdef
example 256 bit key :
Key1=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key1=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key2=Key has not been set.
Manage Key2
USAGE - Key2=[128 or 256 key in hex]
example 128 bit key : Key2=1234567890abcdef1234567890abcdef
example 256 bit key :
Key2=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key2=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key3=Key has not been set.
Manage Key3
USAGE - Key3=[128 or 256 key in hex]
example 128 bit key : Key3=1234567890abcdef1234567890abcdef
example 256 bit key :
Key3=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key3=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key4=Key has not been set.
Manage Key4
USAGE - Key4=[128 or 256 key in hex]
example 128 bit key : Key4=1234567890abcdef1234567890abcdef
example 256 bit key :
Key4=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key4=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key5=Key has not been set.
Manage Key5
USAGE - Key5=[128 or 256 key in hex]
example 128 bit key : Key5=1234567890abcdef1234567890abcdef
example 256 bit key :
Key5=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key5=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key6=Key has not been set.
Manage Key6
USAGE - Key6=[128 or 256 key in hex]
example 128 bit key : Key6=1234567890abcdef1234567890abcdef
example 256 bit key :
Key6=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key6=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key7=Key has not been set.
Manage Key7
USAGE - Key7=[128 or 256 key in hex]
example 128 bit key : Key7=1234567890abcdef1234567890abcdef
example 256 bit key :
Key7=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key7=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key8=Key has not been set.
Manage Key8
USAGE - Key8=[128 or 256 key in hex]
example 128 bit key : Key8=1234567890abcdef1234567890abcdef
example 256 bit key :
Key8=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key8=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key9=Key has not been set.
Manage Key9
USAGE - Key9=[128 or 256 key in hex]
example 128 bit key : Key9=1234567890abcdef1234567890abcdef
example 256 bit key :
Key9=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key9=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key10=Key has not been set.
Manage Key10
USAGE - Key10=[128 or 256 key in hex]
example 128 bit key : Key10=1234567890abcdef1234567890abcdef
example 256 bit key :
Key10=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key10=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key11=Key has not been set.
Manage Key11
USAGE - Key11=[128 or 256 key in hex]
example 128 bit key : Key11=1234567890abcdef1234567890abcdef
example 256 bit key :
Key11=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key11=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key12=Key has not been set.
Manage Key12
USAGE - Key12=[128 or 256 key in hex]
example 128 bit key : Key12=1234567890abcdef1234567890abcdef
example 256 bit key :
Key12=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key12=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key13=Key has not been set.
Manage Key13
USAGE - Key13=[128 or 256 key in hex]
example 128 bit key : Key13=1234567890abcdef1234567890abcdef
example 256 bit key :
Key13=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key13=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key14=Key has not been set.
Manage Key14
USAGE - Key14=[128 or 256 key in hex]
example 128 bit key : Key14=1234567890abcdef1234567890abcdef
example 256 bit key :
Key14=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key14=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key15=Key has not been set.
Manage Key15
USAGE - Key15=[128 or 256 key in hex]
example 128 bit key : Key15=1234567890abcdef1234567890abcdef
example 256 bit key :
Key15=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key15=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
encryption.Key16=Key has not been set.
Manage Key16
USAGE - Key16=[128 or 256 key in hex]
example 128 bit key : Key16=1234567890abcdef1234567890abcdef
example 256 bit key :
Key16=1234567890abcdef1234567890abcdef1234567890abcdef1234567890abcdef
example clear key : Key16=clear
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
==========================================================================
dataPath
==========================================================================
dataPath.compressionEnabled=true
type:bool default:true
** Savable Configuration Item **
--------------------------------------------------------------------------
dataPath.otaMaxFragmentSize=1000
type:uint32_t default:RATE_1_1
options:["RATE_1_1","RATE_7_8"]
** Savable Configuration Item **
--------------------------------------------------------------------------
dataPath.aggregateEnabled=false
type:bool default:false
** Savable Configuration Item **
--------------------------------------------------------------------------
dataPath.routeMinSignalMarginThresh=10
Setting this value too small such that normal traffic does not
keep the MAC table entry from expiring may generate excess
network traffic. It is recommended that this timeout is longer
than the polling rate on the network.
Entries will not use the new timeout value until they are updated
when a packet transfer.
==========================================================================
localDiagnostics
==========================================================================
localDiagnostics.signalLevel=-128
Signal Level
Signal Level in dBm of last RX packet. Shows -128 if no packet has
been received since the stats were cleared.
type:int
--------------------------------------------------------------------------
localDiagnostics.signalMargin=-29
Signal Margin
* The amount of link margin in dB the last received packet experienced.
type:int
--------------------------------------------------------------------------
localDiagnostics.NoiseLevel=-119
Noise Level
* The amount of link noise measured in dB before the last packet was
transmitted.
type:int
--------------------------------------------------------------------------
localDiagnostics.VSWR=35
VSWR
This value is proportional to the VSWR (Voltage Standing Wave
Ratio) measured from the last packet transmitted. The value
can range from 1 to 2 for an excellent match, 2 to 10 for a
good match and it will be > 100 for a poor match on the antenna
port. A value of 0 indicates the VSWR reading is not up to
date or cannot be determined.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.TxSuccess=100
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.TxAvailability=100
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RxSuccess=100
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.timestamp=3873
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioTx=2
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioRx=0
--------------------------------------------------------------------------
localDiagnostics.RadioReliableTx=0
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioReliableRx=0
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioRexmit=0
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioAckTx=0
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioNoAckTx=0
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioTimedOut=0
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioBadAckRx=0
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioTooLong=0
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioTooShort=0
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioBadSync=0
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioBadCRC=0
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioContentionDrop=0
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioSendingDrop=0
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioLLTx=1
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.RadioLLRx=0
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.cntSTX=76
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.cntETX=76
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.cntBadSync=0
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.cntBadBCC=0
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.interfaceDataTx=12
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.interfaceDataRx=0
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.interfaceBytesTx=4092
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.interfaceBytesRx=4006
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.resetsDetected=2
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.resetsSent=0
* For internal use only.
type:uint32_t
--------------------------------------------------------------------------
localDiagnostics.resetStats
Reset Statistics
* Reset localDiagnostic counters.
type:execute
options:["Now"]
--------------------------------------------------------------------------
localDiagnostics.getStats
Get Statistics
* Retrieve the localDiagnostics from the radio now.
--------------------------------------------------------------------------
localDiagnostics.monitoredNode=64206
Monitor Node
Set this parameter to the node id of a device to monitor the
signal level. Use the showNodeDiags command to view the
received signal level (RSSI) of this node.
--------------------------------------------------------------------------
localDiagnostics.showNodeDiags
--------------------------------------------------------------------------
localDiagnostics.MacTableShow
type:execute
--------------------------------------------------------------------------
localDiagnostics.MacTableClear
Clear the MAC to nodeId mapping table and force routes to be relearned.
type:execute
options:["Now"]
--------------------------------------------------------------------------
localDiagnostics.SupplyVoltage
Supply Voltage
The supply voltage to this radio in units of V.
Radios that do not support this measurement will report 0 V.
type:float
--------------------------------------------------------------------------
==========================================================================
config
==========================================================================
config.reset
type:execute
options:["Idle","Now","Reboot","Reset"]
--------------------------------------------------------------------------
config.factoryDefaults
type:execute
options:["Idle","Set"]
--------------------------------------------------------------------------
config.save
type:execute
options:["Now"]
--------------------------------------------------------------------------
config.restore
type:execute
options:["Now"]
--------------------------------------------------------------------------
config.licenseState
type:execute
--------------------------------------------------------------------------
==========================================================================
services
==========================================================================
services.timeOutCli=900
==========================================================================
network
==========================================================================
network.mac_address=00:1d:e3:01:04:a3
--------------------------------------------------------------------------
network.ip_address=192.168.111.100
type:address default:192.168.111.100
** Savable Configuration Item **
--------------------------------------------------------------------------
network.netmask=255.255.255.0
type:address default:255.255.255.0
** Savable Configuration Item **
--------------------------------------------------------------------------
network.gateway=192.168.111.1
type:address default:192.168.111.1
** Savable Configuration Item **
--------------------------------------------------------------------------
network.stpEnabled=false
type:bool default:false
** Savable Configuration Item **
--------------------------------------------------------------------------
network.txqueuelen=25
type:address default:8.8.8.8
** Savable Configuration Item **
--------------------------------------------------------------------------
network.nameserver_address2=8.8.4.4
type:bool default:false
** Savable Configuration Item **
--------------------------------------------------------------------------
network.arpFilterEnabled=false
type:bool default:false
** Savable Configuration Item **
--------------------------------------------------------------------------
network.vlanMgmt=0
==========================================================================
networkStats
==========================================================================
networkStats.rx_bytes=0
type:uint32_t
--------------------------------------------------------------------------
networkStats.rx_packets=0
Number of Ethernet packets received from the radio network.
type:uint32_t
--------------------------------------------------------------------------
networkStats.rx_dropped=0
Number of Ethernet packets received from the radio network that were dropped at
the Ethernet interface.
type:uint32_t
--------------------------------------------------------------------------
networkStats.rx_errors=0
Number of Ethernet packets received from the radio network that were had Ethernet
errors.
type:uint32_t
--------------------------------------------------------------------------
networkStats.tx_bytes=896
Number bytes of Ethernet packets received from the Ethernet port and sent over
the radio network.
type:uint32_t
--------------------------------------------------------------------------
networkStats.tx_packets=12
Number Ethernet packets received from the Ethernet port and sent over the radio
network.
type:uint32_t
--------------------------------------------------------------------------
networkStats.tx_dropped=0
Number Ethernet packets received from the Ethernet port but dropped because the
txqueue was full.
An increase of this counter may indicate that increasing the txqueuelen
parameter may improve
overall network performance.
type:uint32_t
--------------------------------------------------------------------------
networkStats.tx_errors=0
Number Ethernet packets received from the Ethernet port that were in error.
type:uint32_t
--------------------------------------------------------------------------
==========================================================================
ntp
==========================================================================
ntp.ntpReference=NETWORK_TIME_SERVER
Ntp is always running. This setting determines if the time corrections are
comming
from the local clock or if thay are comming over the network. If no server
address
is set then the reference will fallback to local clock,
type:uint32_t default:NETWORK_TIME_SERVER
options:["NETWORK_TIME_SERVER","REFCLK_LOCALCLOCK"]
** Savable Configuration Item **
--------------------------------------------------------------------------
ntp.ntpRestart
type:execute
options:["Now"]
--------------------------------------------------------------------------
ntp.ntpDate
Set the local time from other NTP servers on the network.
This command will set the local clock with the time from the NTP
servers specified in ntp_address1-ntp_address5. The server with
the best clock, as defined by the NTP protocol will be used.
type:execute
options:["Now"]
--------------------------------------------------------------------------
ntp.ntp_address1
Server to be used for syncing time. Use 0.0.0.0 to skip this server.
This can be a server such as time.nist.gov time1.google.com or it can be
the IP address of another radio in the network.
A common usecase is to have all of the endpoints and repeaters use
the IP address of the gateway radio then the entire network will stay
synced to the gateway time.
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
ntp.ntp_address2
Server to be used for syncing time. Use 0.0.0.0 to skip this server.
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
ntp.ntp_address3
Server to be used for syncing time. Use 0.0.0.0 to skip this server.
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
ntp.ntp_address4
Server to be used for syncing time. Use 0.0.0.0 to skip this server.
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
ntp.ntp_address5
Server to be used for syncing time. Use 0.0.0.0 to skip this server.
type:string
** Savable Configuration Item **
--------------------------------------------------------------------------
==========================================================================
Com1
==========================================================================
Com1.mode=RS232
type:uint32_t default:RS232
options:["RS232"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com1.handler=TerminalServer
type:uint32_t default:TerminalServer
options:["ModbusRTU","TerminalServer","Cli","ModbusPassthru","Trace",
"Setup","off"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com1.baudrate=115200
type:uint32_t default:115200
options:["1200","2400","4800","9600","14400",
"19200","38400","57600","115200","230400",
"460800","921600"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com1.databits=8
type:uint32_t default:8
options:["7","8"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com1.parity=None
type:uint32_t default:None
options:["None","Even","Odd"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com1.stopbits=1
type:uint32_t default:1
options:["1","2"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com1.duplex=Full
type:uint32_t default:Full
options:["Full"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com1.flowControl=Off
type:uint32_t default:Off
options:["Off","Hardware"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com1.delayBeforeSendMs=0
Com port will delay sending in Ms to allow the other side to switch from tx to rx
mode.
Com port will send a break signal for at least the number of microseconds
specified before sending the data.
type:uint32_t
--------------------------------------------------------------------------
Com1.RxBytes=0
type:uint32_t
--------------------------------------------------------------------------
Com1.ConnectionDrops=0
type:uint32_t
--------------------------------------------------------------------------
==========================================================================
Com2
==========================================================================
Com2.mode=RS232
type:uint32_t default:RS232
options:["RS232"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com2.handler=TerminalServer
type:uint32_t default:TerminalServer
options:["ModbusRTU","TerminalServer","Cli","ModbusPassthru","Trace",
"Setup","off"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com2.baudrate=115200
type:uint32_t default:115200
options:["1200","2400","4800","9600","14400",
"19200","38400","57600","115200","230400",
"460800","921600"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com2.databits=8
type:uint32_t default:8
options:["7","8"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com2.parity=None
type:uint32_t default:None
options:["None","Even","Odd"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com2.stopbits=1
type:uint32_t default:1
options:["1","2"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com2.duplex=Full
Com port is full or half duplex
type:uint32_t default:Full
options:["Full"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com2.flowControl=Off
type:uint32_t default:Off
options:["Off","Hardware"]
** Savable Configuration Item **
--------------------------------------------------------------------------
Com2.delayBeforeSendMs=0
Com port will delay sending in Ms to allow the other side to switch from tx to rx
mode.
Com port will send a break signal for at least the number of microseconds
specified before sending the data.
type:uint32_t
--------------------------------------------------------------------------
Com2.RxBytes=0
type:uint32_t
--------------------------------------------------------------------------
Com2.ConnectionDrops=0
type:uint32_t
--------------------------------------------------------------------------
==========================================================================
TerminalServerRelay
==========================================================================
TerminalServerRelay.termserv_relay_mapping=TERMSERV_RELAY_DISABLED
For the relay funtion to operate, COM1 must be assigned to port 5041,
and COM2 must be assigned to port 5042 on both the local and remote
terminal servers.
TERMSERV_RELAY_DISABLED
* Data forwarding between local and remote COM ports is disabled.
LOCAL_BOTH_COM_TO_REMOTE_BOTH_COM
* Data is forwarded between the local COM1 and remote COM1 ports.
* Data is forwarded between the local COM2 and remote COM2 ports.
LOCAL_COM1_TO_REMOTE_COM1
* Data is forwarded between the local COM1 and remote COM1 ports.
LOCAL_COM2_TO_REMOTE_COM2
* Data is forwarded between the local COM2 and remote COM2 ports.
LOCAL_BOTH_COM_TO_REMOTE_COM1
* Data is forwarded between the local COM1 and remote COM1 ports.
* Data is forwarded between the local COM2 and remote COM1 ports.
LOCAL_BOTH_COM_TO_REMOTE_COM2
* Data is forwarded between the local COM1 and remote COM2 ports.
* Data is forwarded between the local COM2 and remote COM2 ports.
LOCAL_COM1_TO_REMOTE_BOTH_COM
* Data is forwarded between the local COM1 and remote COM1 ports.
* Data is forwarded between the local COM1 and remote COM2 ports.
LOCAL_COM2_TO_REMOTE_BOTH_COM
* Data is forwarded between the local COM2 and remote COM1 ports.
* Data is forwarded between the local COM2 and remote COM2 ports.
type:uint32_t default:TERMSERV_RELAY_DISABLED
options:
["TERMSERV_RELAY_DISABLED","LOCAL_BOTH_COM_TO_REMOTE_BOTH_COM","LOCAL_COM1_TO_REMOT
E_COM1","LOCAL_COM2_TO_REMOTE_COM2","LOCAL_BOTH_COM_TO_REMOTE_COM1",
"LOCAL_BOTH_COM_TO_REMOTE_COM2","LOCAL_COM1_TO_REMOTE_BOTH_COM","LOCAL_COM2_TO_REMO
TE_BOTH_COM"]
** Savable Configuration Item **
--------------------------------------------------------------------------
TerminalServerRelay.remote_termserv_ip_address=0.0.0.0
type:address default:0.0.0.0
** Savable Configuration Item **
--------------------------------------------------------------------------
==========================================================================
date
==========================================================================
date.upTime=46
type:uint32_t
--------------------------------------------------------------------------
date.upTimeString=Uptime 0Days 00h:00m:46s
type:execute
--------------------------------------------------------------------------
date.dcAppUptime=Uptime 0Days 00h:00m:16s
--------------------------------------------------------------------------
date.dcAppStartTime=01/01/1970 01:04:19
type:uint32_t
--------------------------------------------------------------------------
date.time=3875
type:uint32_t
--------------------------------------------------------------------------
date.timeString=01/01/1970 01:04:35
type:execute
--------------------------------------------------------------------------
==========================================================================
snmp
==========================================================================
snmp.v1Enabled=false
SNMP V1 Enable/Disable
* true enables SNMP V1, false disables SNMP V1
type:bool default:false
** Savable Configuration Item **
--------------------------------------------------------------------------
snmp.v2cEnabled=false
type:bool default:false
** Savable Configuration Item **
--------------------------------------------------------------------------
snmp.v3Enabled=false
SNMP V3 Enable/Disable
* true enables SNMP V3, false disables SNMP V3
type:bool default:false
** Savable Configuration Item **
--------------------------------------------------------------------------
snmp.roCommunityName=public
type:string default:public
** Savable Configuration Item **
--------------------------------------------------------------------------
snmp.rwCommunityName=private
type:string default:private
** Savable Configuration Item **
--------------------------------------------------------------------------
snmp.snmpUser
This item manages the SNMP V3 users. These operations are supported:
Add User:
snmpUser add <username> <ReadOnly or ReadWrite> <MD5 or SHA> <Authentication
Passphrase> <AES or DES> <Encryption Passphrase>
Modify User:
snmpUser modify <username> <ReadOnly or ReadWrite> <MD5 or SHA> <Authentication
Passphrase> <AES or DES> <Encryption Passphrase>
Remove User:
snmpUser remove <username>
type:execute
--------------------------------------------------------------------------
==========================================================================
security
==========================================================================
security.enablePtpInterface=true
type:bool default:true
** Savable Configuration Item **
--------------------------------------------------------------------------
security.enableEthernetLogin=true
type:bool default:true
** Savable Configuration Item **
--------------------------------------------------------------------------
==========================================================================
runtimeEnvironment
==========================================================================
runtimeEnvironment.rteReset
type:execute
options:["Cancel","Hard"]
--------------------------------------------------------------------------
runtimeEnvironment.rteVersion=EB-X1122TP.16
This item provides the version number for the active developer
environment.
type:execute
--------------------------------------------------------------------------
runtimeEnvironment.rteTemplateVersion=EB-X1122TP.16
This item provides the version number for the developer environment
template.
type:execute
--------------------------------------------------------------------------
runtimeEnvironment.rteInstalledByAppsVersion=EB-X1122TB.66
This item provides the version number of the firmware that was
used to install the runtime developer environment.
type:execute
--------------------------------------------------------------------------
==========================================================================
Modbus
==========================================================================
Modbus.modbusDeviceId=1
type:uint32_t default:1
** Savable Configuration Item **
--------------------------------------------------------------------------
Modbus.modbusTcp=502
type:execute
--------------------------------------------------------------------------
Modbus.write
type:execute
--------------------------------------------------------------------------
Modbus.readCoils
type:execute
--------------------------------------------------------------------------
Modbus.writeCoils
type:execute
--------------------------------------------------------------------------
Modbus.modbusLayout
type:execute
--------------------------------------------------------------------------
==========================================================================
ioExCom
==========================================================================
ioExCom.ioExDeviceId=100