You are on page 1of 1

TECHNICAL SERVICE BULLETIN

BULLETIN NUMBER: D146/D147/D148/D149/D150 – 050 02/16/2016


APPLICABLE MODEL:
LANIER – MP C3003/MP C3503/MP C4503/MP C5503/MP C6003
RICOH – MP C3003/MP C3503/MP C4503/MP C5503/MP C6003
SAVIN - MP C3003/MP C3503/MP C4503/MP C5503/MP C6003

SUBJECT: SC866 OCCURS AFTER REPLACING THE CONTROLLER BOARD

SYMPTOM:
SC866 occurs and the SC cannot be resolved after replacing the Controller Board.

CAUSE:
The RAM-DIMM (P/N: 19070159) has become corrupted.

SOLUTION:
If the symptom occurs, replace the RAM-DIMM (P/N: 19070159).

GENERAL:

PART NUMBER DESCRIPTION QTY


19070159 RAM-DIMM 1

Copyright  2016 RICOH Americas Corporation. All rights reserved. Page 1 of 1