Professional Documents
Culture Documents
com
Luminaire Program
Outdoor
2014 / 2015
Light is OSRAM
Any manipulation of our products or packaging, including
but not limited to modification, reworking or restamping, is
prohibited and infringes our registered trademark rights.
Such modifications may impair the technical properties of
our products, destroy them or cause consequential damage
or injury, for which OSRAM cannot under any circumstances
be held responsible.
Luminaire Program
Outdoor
2014 / 2015
Light is OSRAM
0 Introduction | Innovation
OSRAM is light
OSRAM designs the future of light. We provide innovative, custom-designed
solutions for the complete spectrum of light, creating added value for
customers around the world. As the only globally active pure lighting
company, OSRAM has a pioneering role and set standards in the market for
light. OSRAM strives to improve quality of life with optimal products and
solutions for a wide variety of applications.
Our range includes vertically integrated products and With this philosophy in mind, we support the everyday lives
solutions along the complete value creation chain for light, of customers in a wide variety of settings: at home, in
ranging from light sources, including lamps, components public spaces, for work and leisure, for educational
and optical semiconductors, to ballasts, other lighting purposes and for safe, reliable mobility.
components and complete luminaires, light management
systems and lighting solutions, in addition to value-added OSRAM, Siteco and Traxon provide precisely the right
services. solutions for nearly all professional lighting requirements, in
turn optimally supporting people in all walks of life.
With the concept of “OSRAM is Light”, the company
provides lighting solutions for all areas of life together with
its flagship brands Siteco and Traxon Technologies.
0.1
Introduction | Innovation 0
0.2
0 Introduction | Innovation
Systematic efficiency
Innovative light enables design flexibility. A lighting system is efficient
when all components are optimally matched, and the result is reliable
functionality and maximum quality of light in an ideal ratio to energy
consumption and costs.
Efficiency is determined by various factors. OSRAM, Siteco control concepts for maximum visual comfort and also
and Traxon consistently place their trust in three letters for practical installation solutions that save time, are simple and
light sources that have triggered a technical revolution in the also highly convenient.
lighting industry: LED. It's only decades of experience,
profound knowledge and complex engineering that are LED luminaires are only able to exploit their complete
capable of exploiting its complete potential – to save efficiency potential when integrated into intelligent control
energy, to cut costs and greenhouse gas emissions and systems. LED lighting can be designed to be intelligent
also to raise the quality of light and visual comfort to the enough to individually respond to differing everyday
next level. situations and adapt according to requirements. Intelligent
light management is becoming an ever more important
LED requires an overall system precisely designed for this component of complete solutions, both for indoor and
technology in order to sustainably function: housings with outdoor applications.
optimal thermal management for long lifespans, light
0.3
Introduction | Innovation 0
0.4
0 Introduction | Online Tools
Siteco ® Lighting Tool Indoor cost effi ciency calculator Modario ® trunking configurator
The software program developed Which operating costs can be saved Plan comfortably, work successfully.
specifically for Siteco luminaires helps with new light? How is CO2 emmission With the Modario® trunking
to find all luminaires via the familiar reduced with LED technology, and how configurator, planning complex
catalogue structure as well as with quickly is your invest amortised? The trunking systems becomes a simple
individual characteristics. A special cost-efficiency calculator supplies all exercise, and the program supplies
feature is the simple and convenient the answers, with comparisons of ob- information concerning availability,
transfer of relevant data via drag and solete and new systems as well as the configurations and installation - simply,
drop to RELUX and DIALUX. download of PDF documentation. reliably and quickly.
The Modario® trunking configurator is
www.siteco.com/lighting- www.siteco.de/ connected directly to the electronic
calculation wirtschaftlichkeitsrechner-innen catalogue.
www.siteco.de/
lichtbandkonfi gurator
0.5
Introduction | Online Tools 0
Are there similar ranges of tasks to The up-to-date reference work for all indoor and outdoor luminaires, including all
specific requirements? How was the relevant data, ranging from product images and installation instructions to tender
solution created? texts and photometric data, as well as plug-ins for light calculation
Our online sample installations have software. Comprehensive, clear and user-friendly.
been calculated by lighting experts so A smart add-on is the Siteco rapid calculation tool as a random calculator for
that the specific solution is always initial quantity estimations.
optimal in terms of compliance with
standards, quality of light and system www.siteco.de/innenleuchten
efficiency. www.siteco.de/aussenleuchten
To be used as sources of inspiration or
for specific solutions. www.osram.de/innenleuchten
www.osram.de/aussenleuchten
www.siteco.com/sample-projects
0.6
0 Introduction | Applications
Individual solutions must prove themselves in practice for experts for transforming these demands into solutions.
the targeted lighting task at the end of the day, and Together we have a rich source of experience gained from
achieving this is with a dialogue between all project many
partners. The more heads used and the more knowledge, successfully implemented projects. When this source of
experience, creativity and passion brought into the knowledge flows together into a continuous dialogue
processes, the better is the result. Our customers are between experts, optimal solutions are created that are
experts for their specific requirements, and we're the ideal for the specific lighting tasks of customers.
0.7
Introduction | Applications 0
0.8
0 Introduction | Offi ce
0.9
Introduction | Offi ce 0
A pleasant atmosphere where employees feel at ease and Simultaneously though, ecological aspects also determine
precisely the right surroundings for productive work and offices of the future – increasing energy overheads and
individual needs are the tasks of office and management rents demand the efficient utilisation of space with flexible,
buildings. These also aim to supply an ideal environment for power-saving lighting solutions.
modern office people, functioning as globally networked
knowledge carriers. It's here that light plays a decisive role, This philosophy determines our coordinated and flexible
in both a functional and emotional sense. tools for lighting that simplify your daily work, achieving
greater motivation and concentration.
A small location and big ideas: creative and productive work After seeing the facade outside, visitors entering foyers and
takes place at desks, with tasks requiring both individuality reception areas gain a second highly important impression.
and teamwork as well as concentration and communication. Lighting in such applications is focused on a mix of
Lighting needs to supply optimal visual conditions, and decorative and functional factors, and the same applies for
especially if work is carried out on computer screens. Light corridors and connecting hallways as part of the central
in such applications should however also reflect modern infrastructure and as an important component of interior
office workers: innovative, intelligent and individual. design. The right light has a welcoming function and creates
atmosphere, but also ensures good orientation and
successful social aspects.
0.10
0 Introduction | Offi ce
Generous glass facades and bright rooms flooded with light with all its inherent benefits, making use of the physical laws
are often characteristic of modern office and management of absorption and refraction to perfectly illuminate rooms
buildings. And not without reason, because views to the and avoid excessive warmth and glare. “Hot” sunlight is
outside create a feeling of distance and a pleasant sense of reflected and only diffuse “cool” daylight is allowed to enter
space. Only with daylight do we see objects in their natural the space. In this way artificial light and daylight ideally
colours. Daylight also represents warmth, and in summer supplement each other. Energy consumption for artificial
months this can lead to uncomfortable room temperatures lighting and air-conditioning is reduced and room comfort is
and glare. Siteco daylight systems utilise natural sunlight improved.
0.11
Introduction | Offi ce 0
Variable workstations, variable room concepts and variable In the transition zone from outside into the interior and from
needs – flexibility and functionality are two essential daylight to artificial light, suitable lighting creates a gradation
characteristics for the illumination of desk workstations. between bright and dark that is easy on the eyes, and
On the one hand, standards must be complied with for sufficient brightness and good colour rendering contribute
illuminance levels and glare reduction, and on the other to greater visual comfort, orientation and safety. Lighting
hand individual needs are focused on, fulfilled with intelligent should however never have a monotonous look but should
sensor technology and control options. always appear balanced and dynamically accentuating.
The floorstanding luminaires of the Futurel® LED range emit LEDVANCE® downlights are available in four construction
light with high precision onto work surfaces thanks to sizes as highly diverse lighting tools that provide pleasant
special reflector technology, and with their purist designs general lighting in foyers, corridors and traffic zones. The
support open, transparent interior concepts. An integrated shadow gap, also a feature of the Lunis 2® downlight family,
presence and brightness sensor configured via Bluetooth allows them to blend ideally into sophisticated
transforms the luminaires into intelligent team players in surroundings.
office environments. Put simply: compact design and efficiency with high
performance.
0.12
0 Introduction | Industry
0.13
Introduction | Industry 0
Reliable light
for dependable processes
Innovative lighting solutions for industry
Storage, production and logistics. People, machines and At the same time though, companies have to keep a close
processes. All cogs must be perfectly coordinated if an eye on energy overheads.
industrial company is to functions successfully, and an What counts at the end of the day is total efficiency in terms
important precondition for this is the right light at the right of economic luminaires and components, simple installation
time, and in the right location. Employees need optimal and flexible utilisation, modular systems, light control and
visual conditions to work in a concentrated way and without upgrade options. We provide all of this from a single source,
errors, and to safely operate machines. giving success at the end of the day.
Semi-products, production equipment, materials and goods The right light for specific tasks – in the industrial production
stored logically, located simply and effectively and distributed sector this is all about people working safely with machines.
rapidly and reliably – industrial warehouse and logistics The size, form and processing speed of products is essen-
facilities are the precondition for the smooth production and tial for the lighting solution, and the following applies: the
sales of products and goods. Whether it's highbay racking finer and more small-scale the work, the more light must
or cold stores, the requirements demanded by storage perform, and with high reliability, in challenging ambient
facilities on lighting solutions are as diverse as the tasks. conditions, with variable hall utilisation, by day and by night.
0.14
0 Introduction | Industry
0.15
Introduction | Industry 0
Rooms with high humidity, wide temperature ranges, dust, Monsun® 2 LED was designed precisely for such demands.
splash or jet water must be equipped with especially Its sealed construction and dirt-repellent surface
resistant lighting systems, and these have to be compact, characteristics defy adverse surroundings.
tough and designed for economic and reliable operation The necessary flexibility in professional applications is
with a long lifespan. provided by a range of technical versions and features such
The ideal solution for such cases are damp-proof luminaires as emergency light or integration into the Modario® trunking
suitable for applications ranging from cold stores, laboratories system.
and logistics areas to manufacturing, parking garages and
canopied outdoor areas.
0.16
0 Introduction | Retail
0.17
Introduction | Retail 0
Premium goods, attractive prices and friendly service make We bathe your products in a very advantageous light, whether
customers loyal. Atmosphere and a sense of emotion are with colour-true general lighting, brilliant spotlights or efficient
becoming ever more important though for long-term success light management systems, and offer ideal lighting solutions
in the retail trade. People perceive 80% of their surroundings for any requirement and any sector. Efficient, flexible and
with their eyes, and lighting during shopping plays an essential individual, enabling you to achieve your success.
role: light creates atmosphere, arouses emotions, guides
attention to goods and also aids customer guidance.
Daily shopping achieves more enjoyment and desire with the The sound of a new motor, the smell of an untouched interior
right ambience, freshness and shopping experiences. LED and the feel of instruments is still far away, but the image,
luminaires score points in terms of energy efficiency, long expectations, emotions and sense of driving are already in
service life and long maintenance intervals – but also as an customers' heads. Showrooms are modern worlds of
example of a “green” technology with a modern experience, and LED lighting tools support these in a
image. contemporary and spectacular way.
Specialist outlets
Our light transforms shopping into experiences
0.18
0 Introduction | Retail
When setting accents, rendering colours appealingly, The Lunis ® SL-T spotlight is just such an all-rounder, and a
playing with light and shadow and bringing light to exactly specialist at the same time. A single luminaire with many
where it should be, smart, diverse solutions are needed for options: two light technologies (LED, HIT-CE), two mounting
special campaign surfaces, in service areas with counters options, three housing colours and a wide selection of filters
and cabinets or for high quality shop and boutique areas and reflectors – ideal lighting solutions are simply configured
with high levels of sophistication. Goods should be with Lunis® SL-T.
displayed to directly arouse desires and make offers
irresistible.
0.19
Introduction | Retail 0
Efficiency and fl exibility along the complete line Highly precise illumination
Modario ® trunking system with LED inserts Lunis 2 ® LED downlights
The food retail sector and specialist markets are complex Special offers, unusual goods and outstanding brands need
spaces with an array of technical lighting requirements. to be illuminated with special care. Good light
Good light is flexible and diverse enough to adapt well to emphasises the inherent quality of offers and supports the
changing demands, and especially flexible and diverse underlying message of brands and labels. The interaction
lighting tools are needed when outlets layouts are modified between the surfaces of goods and the light sources
or if time-limited campaigns are displayed. themselves is complex and can therefore only really be
The Modario® trunking system represents an especially solved with mature and photometrically outstanding
innovative and easily installed solution. Whether with lighting tools.
efficient T5 technology or innovative LED, with optical The diverse downlights of the Lunis® 2 LED family
inserts for general lighting or with spots for accent lighting, represent an excellent solution.
Modario® makes sure of optimal quality of light and at the Ranging from various wallwashers and photometrically finely
same time enables accents to be set. graded downlights to design-integrated sensor
modules, there is hardly any lighting requirement that
cannot be solved with these unusually precise lighting
instruments.
0.20
0 Introduction | Street/Urban
0.21
Introduction | Street/Urban 0
Safety in road traffic, attractiveness of the area and Completely new options have become apparent in all
protection of property: road lighting is an important and facets of lighting, including energy consumption,
necessary part of our infrastructure, but it is also a strain for maintenance levels, quality of light, control and design.
community budgets and for ecological balances. We purposefully design this future to enable local
Combining quality of light and energy efficiency is of authorities to make traffic routes safer, architectural areas
primary importance. The future will be determined by LED more appealing and energy balances more positive, with a
technology, and lighting was never as efficient, flexible and better quality of light.
innovative.
The main task of road lighting is apparently simple: to Light makes places attractive and contributes to the
ensure sufficient visual conditions for all road users. positive appearance of a town or district. During the day
Minimum levels are stipulated by standards (DIN EN 13201). luminaires set design accents, and at night their light
Road users should be able to identify changing situations as effects determine appearances. In addition to the
well as sudden occurrences quickly and clearly, and at functional task of illumination (DIN EN 13201), luminaires
distances in order to have enough time to respond. also achieve atmosphere and ambience. The lighting of
Technical road lighting with a high, functional quality of light urban environments increases the level of attraction and is
makes an active contribution to this. also able to enliven inner cities and promote business and
gastronomy.
0.22
0 Introduction | Street/Urban
Streetlight 10 LED
Page 2.25 + 3.9 + 4.35
0.23
Introduction | Street/Urban 0
More than 70% of road lighting in Europe is energetically Road lighting must be functional and comply with specific
obsolete, and hundreds of millions of euros could be saved. lighting tasks, but it can and should be representative in
A majority of these are lantern or mushroom-shaped certain areas such as pedestrian zones and public plazas,
luminaires for illuminating pedestrian paths, residential structuring the space and setting accents as well as contri-
streets and ancillary roads. Their looks are familiar and their buting to a pleasant atmosphere. And at night as well as
designs are classics, but in terms of energy efficiency and during the day. Lighting solutions are needed that not only
light quality they are from the last millennium. have convincing functionality but also outstanding design.
The LED modules 520 and 540 render lantern-shaped The DL® 20 LED impressively shows how high-performance
luminaires fit for the future in terms of energy and optics. LED technology can be combined with outstanding quality
They are suitable as LED retrofit solutions for refurbishing of light and excellent design. The luminaire is focused com-
luminaire heads fitted with standard lamps, and are ideal as pletely on reduction, optics and materiality – the essentials –
efficient new installations with low maintenance and low and in this way intelligently transfers the archetype of the
costs thanks to modern LED gear trays and integrated mushroom-shaped luminaire into the LED era. Good design
intelligence. LANTERN LED, CITY LIGHT LED, and after all is subordinated to specific tasks.
MUSHROOM LUMINAIRE LED have arrived in the future.
0.24
0 Introduction | Sports
0.25
Introduction | Sports 0
Sport is more than simply a competition for top results, goals We know that professional athletes need professional light
and victories. When the dynamism of play is transferred to to be able to achieve best performance, but the same is true
spectators then sport becomes a perceptible experience and for sports at grass-roots level.
an event. To achieve this, fans in rear spectator ranks must Whether indoors or outdoors, HDTV-compliant or low-cost
also be able to follow what is happening in a stadium. Light for local sports halls, our light gives you decisive
makes peak athletic performances visible, the clashing of advantages in all disciplines.
opposing teams and how sports equipment meets its target.
Hall sports depend on dynamics, drama and speed, and Sports in the open depends on rapidity, dynamics and
brief moments are decisive. Lighting determines whether highly exciting competition, and outside sports provide
you experience such moments or miss them. Ball-proof genuine experience.
solutions protect athletes and spectators, and the quality of And perhaps even more when nature plays its part: sun and
light and good colour rendering emphasise emotion and rain as well as heat and cold are permanent challenges. The
atmosphere, either on-site or on television. Flexibility for task of lighting is to ensure best possible visual conditions
different uses is provided by flexible and energy-efficient and maximum safety in adverse weather
lighting solutions featuring modular control options. conditions and in all seasons of the year, and to guarantee
perfect vision in a technical sense, because large sports
associations have very stringent demands in terms of light
quality and visual comfort.
0.26
0 Introduction | Sports
SiCOMPACT R3 MAXI
Page 5.55
0.27
Introduction | Sports 0
Maximum effi ciency at the highest levels The T16 highbay luminaire represents the ideal solution for
T16 highbay luminaire safety, quality of light and flexibility, and at any height. All
luminaire components are matched to achieve the sole re-
Safety for players and spectators in sports halls has sult of efficiency in terms of energy, service life, light control,
top priority, and highbay luminaires must comply with maintenance and installation. With a luminaire light output
DIN VDE 0710 Part 13. This certifies that luminaires have ratio of up to 93%, amortisation periods of approximately 1.5
been constructed to resist ball impact and can be mounted years are typical whenupgrading obsolete lighting systems.
safely, because balls flying from the playing surface up into
the roof are simply part of the game.
SiCOMPACT® FL MIDI S
Page 5.43
0.28
0 Introduction | Architecture and Objects
0.29
Introduction | Architecture and Objects 0
Emotional light
for lasting impressions
Innovative lighting solutions for architecture and objects
Light generates lasting impressions, enabling new perspec- The challenge with dynamic accent lighting is the individuality
tives, transforming the appearances of what is familiar and of the illuminated object and the vision of the designer. Each
creating spectacular moments. Architectural lighting is type of architecture has specific design challenges and its
becoming ever more a fixed part of marketing and art and own individual character. The path from vision to solution is a
also represents an entertainment factor. Architecture and creative process of intensive teamwork across all phases of
individual objects are transformed into experiences for the project, and we gladly support you in finding the
observers thanks to dynamic accent lighting, and light customised solution that renders your project truly unique.
arouses buildings to life and emphasises their special features.
Architecture and objects are transformed into projection Creating a peaceful and pleasant ambience or setting
surfaces thanks to light, and can be seen from afar without stimulating accents – the options for designing interiors with
effort. light are as unlimited as fantasy itself. From
Dynamic installations can contribute to creating urban shimmering walls and ceilings to illuminated balustrades and
landmarks and making town or city environments more backlit niches, flexible lighting solutions and intelligent
attractive. Solutions consider architectural situations and control systems supply light in a discreet way for
make light available so that it becomes a universal medium completely individual atmospheres in all types of rooms and
for communicating the inherent story of the object and its event locations.
creator.
0.30
0 Introduction | Architecture and Objects
Rendering architecture perceptible with light is not only a The Nano Liner Allegro AC XB is an extremely slender
challenge in terms of planning but also a technological lighting solution for outdoor applications with high
challenge. Tight mounting spaces, lack of space in corners performance and high energy efficiency. The linear system is
and niches and protrusions demand smart and flexible flicker-free, even with control using forward phase
solutions that provide high lumen output and yet blend control dimmers. Three white colour temperatures, RGB and
discretely and invisibly into the architectural context. dynamic white as well as four lengths and two beam angles
provide maximum design flexibility.
The Nano Liner Allegro AC XB is suitable for both planar
lighting as well as linear and indirect lighting, in fact
everywhere where efficient and space-saving solutions are
needed.
0.31
Introduction | Architecture and Objects 0
0.32
1 Facade and path luminaires | Overview
5m
CL LED Spotlight 10
Page 1.31
4m
3m
CL LED Wall
Page 1.13
2m
1m
1.1
Facade and path luminaires | Overview 1
6m
5m
4m
SiCOMPACT® R1 MINI
Page 1.35
3m
NOXLITE® HALOGEN
Page 1.29
1m
1.2
1 Facade and path luminaires | Overview
1.3
Facade and path luminaires | Overview 1
CL LED Ceiling CL LED Wall CL LED Linear CL LED Linear NOXLITE® LED NOXLITE®
Page 1.9 Page 1.13 Ceiling Wall CIRCULAR HALOGEN
Page 1.17 Page 1.21 Page 1.25 Page 1.29
AquaLED ® 2 CW 91 CW 96 CB 90 CB 95
Page 1.43 Page 1.51 Page 1.51 Page 1.55 Page 1.55
1.4
1 Facade and path luminaires | Product search
CL LED Ceiling CL LED Wall CL LED Linear CL LED Linear NOXLITE® LED NOXLITE®
Ceiling Wall CIRCULAR HALOGEN
HIT/HSE
TC-DEL/LEL
TC-D/DD/T
QT ¢
Place of ceiling ¢ ¢ ¢
installation
wall ¢ ¢ ¢ ¢
ground/mast
Installation surface-mounted ¢ ¢ ¢ ¢ ¢ ¢
method
recessed
Light distribution
1.5
Facade and path luminaires | Product search 1
¢/- ¢/-
¢ ¢ ¢
¢ ¢ ¢
¢ ¢ ¢
1.6
1 Facade and path luminaires | Product search
AquaLED ® 2 CW 91 CW 96 CB 90 CB 95 CL LED
Bollard
TC-DEL/LEL
Place of ceiling
installation
wall ¢ ¢
Installation surface-mounted ¢
method
recessed ¢ ¢ ¢ ¢ ¢
Light distribution
single-sided ¢
double-sided ¢
on all sides
asymmetric
symmetric
1.7
Facade and path luminaires | Product search 1
¢ ¢
-/¢/- -/¢/-
-/¢ -/¢
¢ ¢ ¢ ¢
¢ ¢ ¢ ¢
¢ ¢
¢ ¢ ¢ ¢
1.8
1 Facade and path luminaires | Surface-mounted luminaires
CL LED Ceiling
CL LED Ceiling 10 MINI | … MIDI are integral components of An outstanding feature of the luminaires is the purist, integra-
the facade and path luminaires of the CL LED series. The tive and simultaneously highly functional design. The diverse
surface-mounted ceiling luminaires feature a purist construc- configurations and variants offer a high level of flexibility for
tion design with a high level of workmanship: The luminaire design purposes in context with the architecture. Across all
housing is completely of diecast aluminum, and gaskets and individual luminaire types, the CL LED family features a
glass cover flush fit without joints to the housing. For the two standardized LED platform that ensures consistent quality,
length variations, two different light colors are available. performance and light color.
Features Electrics
— discreet, integral design for use in a wide diversity of ar- Luminaire wired ready for connection | with 3-pole
chitectural surroundings (iF product design award 2008) connection terminal, max. 2.5mm² | cable entry for cable
— one uniform LED platform with two different light colors D = 8.5…12mm
(warm white or neutral white) and good color rendering
(CRI > 80) reduces complexity and simultaneously in- Housing
creases the design unity Robust luminaire housing of extruded aluminum with
— long operating life for housing of high-quality, robust die- compact dimensions, housing surface with weather-resistant
cast aluminum and for the LED module (up to 50,000h) powder coating in Siteco® metallic gray (DB 702S) | pro-
— high-performance optics specifically developed for LED tection of glass edge due to housing design | cover of tough-
platform, with clean cut-off for the precise illumination of ened safety glass, fixed without visible screws | air-permeable
horizontal and vertical surfaces membrane for pressure equalization and condensation avoid-
ance | insulation class: I | protection rating: IP65
Lighting technology
Rotationally symmetric medium distribution
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
1.9
Facade and path luminaires | Surface-mounted luminaires 1
107
102
& &
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
1.10
1 Facade and path luminaires | Surface-mounted luminaires
170
102
& &
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
1.11
Facade and path luminaires | Surface-mounted luminaires 1
1.12
1 Facade and path luminaires | Surface-mounted luminaires
CL LED Wall
CL LED Wall 10 MINI | … MIDI | … MAXI are integral compo- An outstanding feature of the luminaires is the purist, inte-
nents of the facade and path luminaires of the CL LED series. grative and simultaneously highly functional design. The
The surface-mounted wall luminaires feature a purist con- diverse configurations and variants offer a high level of
struction design with a high level of workmanship: The hous- flexibility for design purposes in context with the architecture.
ing consists completely of diecast aluminum. The gaskets Across all individual luminaire types, the CL LED family fea-
and glass cover fit flush without joints. For the three length tures a standardized LED platform that ensures consistent
variations, two different light colors and differing accessories quality, performance and light color.
for various lighting tasks are available (MAXI).
Features
— discreet, integral design for use in a wide diversity of Electrics
architectural surroundings (iF product design award 2008) Luminaire wired ready for connection | with 3-pole
— one uniform LED platform with two different light colors connection terminal, max. 2.5mm² | cable entry for cable
(warm white or neutral white) and good color rendering D = 8.5…12mm | for accommodation of on-site cable
(CRI > 80) reduces complexity and simultaneously in- routing: wall mount can be rotated through 180°
creases the design unity
— long operating life for housing of high-quality, robust die- Housing
cast aluminum and for the LED module (up to 50,000h) Robust 2-part luminaire housing of extruded aluminum with
— high-performance optics specifically developed for LED compact dimensions, housing surface with weather-resistant
platform, with clean cut-off for the precise illumination of powder coating in Siteco® metallic gray (DB 702S) | protec-
horizontal and vertical surfaces tion of glass edge due to housing design | cover of tough-
— various light distribution patterns or light characteristics ened safety glass, fixed without visible screws | air-permeable
(colors) due to optical accessory covers increase design membrane for pressure equalization and condensation
flexibility (MAXI) avoidance | insulation class: I | protection rating: IP65
Lighting technology
Luminaire as downlight, uplight or with two-sided light
emission | rotationally symmetric medium distribution;
elliptical light distribution and color accenting via additional
filter discs (MAXI)
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
1.13
Facade and path luminaires | Surface-mounted luminaires 1
152
102
102
CL LED Wall 10 MINI
$$:
[/('.&5,ƁI1OP
Uplight and downlight for wall surface — housing of aluminum, powder-coated in
mounting Siteco® metallic gray (DB 702S); cover of
— light emission above or below; rotationally toughened safety glass, fits flush to
symmetric medium distribution; luminaire housing
with transparent cover — protection rating (lamp compartment): IP65
— LED operating electronics integrated in — insulation class: I
housing
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux
or power consumption can also change correspondingly. The latest values can be found in the photometric test report for the
specific products and in the current download files of the photometric planning data
& &
1.14
1 Facade and path luminaires | Surface-mounted luminaires
152
165
102
CL LED Wall 10 MIDI
$$:
[/('.&5,ƁI1OP
Uplight and downlight for wall surface — housing of aluminum, powder-coated in
mounting Siteco® metallic gray (DB 702S); cover of
— light emission above or below or above toughened safety glass, fits flush to
and below; rotationally symmetric housing
medium distribution; luminaire with — protection rating (lamp compartment): IP65
transparent cover — insulation class: I
— LED operating electronics integrated in
housing
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux
or power consumption can also change correspondingly. The latest values can be found in the photometric test report for the
FGNOP
specific products and in the current download files of the photometric planning data
& &
+P ÕP (PD[O[ (PO[
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
1.15
Facade and path luminaires | Surface-mounted luminaires 1
267
152
102
CL LED Wall 10 MAXI
$$:
[/('.&5,ƁI1OP
FGNOP Uplight and downlight for wall surface — housing of aluminum, powder-coated in
mounting Siteco® metallic gray (DB 702S); cover of
— light emission above or below or above toughened safety glass, fits flush to
and below; rotationally symmetric medium housing
distribution; luminaire with transparent — protection rating (lamp compartment): IP65
cover — insulation class: I
— LED operating electronics integrated in
housing
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or
power consumption can also change correspondingly. The latest values can be found in the photometric test report for the specific
products and in the current download files of the photometric planning data
,PD[FGNOPDWJ
& &
D [ [
D [ [
Light source Order no. Order no.
OSRAM Siteco
+P ÕP (PD[O[ (PO[ Light emission above
LED 3000 > 80 700 25 3.0 4050737462790 5AA530513W
LED 4000 > 80 700 25 3.0 4050737462813 5AA530513N
Light emission above and below
LED 3000 > 80 1100 35 3.1 4050737462714 5AA530523W
LED 4000 > 80 1100 35 3.1 4050737462738 5AA530523N
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
1.16
1 Facade and path luminaires | Surface-mounted luminaires
The linear systems CL LED Linear 60 and … 90 are integral An outstanding feature of the luminaires is the purist, integra-
components of the facade and path luminaires of the CL LED tive and simultaneously highly functional design. The diverse
series. The system for wall and ceiling surface mounting con- configurations and variants offer a high level of flexibility for
sists in each case of one basis module and a luminaire head design purposes in context with the architecture. Across all
of identical form and dimensions. Both components match individual luminaire types, the CL LED family features a stan-
perfectly to form a closed unit fixed by a robust but easy-to- dardized LED platform that ensures consistent quality, per-
operate spring catch system. Joints have become an ele- formance and light color.
ment of design that purposefully breaks up the smooth sur-
faces to give the luminaires a unique character. The striking
housing is constructed completely of diecast aluminum, and
gaskets and cover glass are fitted flush to the housing.
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
1.17
Facade and path luminaires | Surface-mounted luminaires 1
l1
132
126
l 60
Luminaire for ceiling surface mounting (DB 702S); cover of toughened safety
— with Fresnel optics for narrow or wide glass, fits flush to housing; luminaire head
symmetric light distribution fixed to housing via intelligent spring
— LED operating electronics integrated in catch system
housing — protection rating: IP65
— housing consisting of functional support — insulation class: I
and luminaire head, of aluminum,
powder-coated in Siteco® metallic gray
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux
FGNOP or power consumption can also change correspondingly. The latest values can be found in the photometric test report for the
specific products and in the current download files of the photometric planning data
,PD[FGNOPDWJ
& &
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
1.18
1 Facade and path luminaires | Surface-mounted luminaires
l1
132
126
l 60
Luminaire for ceiling surface mounting (DB 702S); cover of toughened safety
— with Fresnel optics for asymmetric light glass, fits flush to housing; luminaire head
distribution fixed to housing via intelligent spring
— LED operating electronics integrated in catch system
housing — protection rating: IP65
— housing consisting of functional support — insulation class: I
and luminaire head, of aluminum,
powder-coated in Siteco® metallic gray
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux
FGNOP or power consumption can also change correspondingly. The latest values can be found in the photometric test report for the
specific products and in the current download files of the photometric planning data
,PD[FGNOPDWJ
& &
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
1.19
Facade and path luminaires | Surface-mounted luminaires 1
1.20
1 Facade and path luminaires | Surface-mounted luminaires
The linear systems CL LED Linear 60 and … 90 are integral An outstanding feature of the luminaires is the purist, integra-
components of the facade and path luminaires of the CL LED tive and simultaneously highly functional design. The diverse
series. The system for wall and ceiling surface mounting con- configurations and variants offer a high level of flexibility for
sists in each case of a basis module and a luminaire head of design purposes in context with the architecture. Across all
identical form and dimensions. Both components match individual luminaire types, the CL LED family features a stan-
perfectly to form a closed unit fixed by a robust but easy-to- dardized LED platform that ensures consistent quality, per-
operate spring catch system. Joints have become an formance and light color.
element of design that purposefully break up the smooth sur-
faces to give the luminaires its unique character. The striking
housing is constructed completely of diecast aluminum, and
gaskets and cover glass are flush fitted to the housing.
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
1.21
Facade and path luminaires | Surface-mounted luminaires 1
l1
60
121
l 95
Uplight for wall surface mounting toughened safety glass, fits flush to
— light emission above; with Fresnel optics housing; luminaire head fixed to housing
for narrow or wide symmetric light via intelligent spring catch system; wall
distribution connection with Siteco® adjustment mod-
— LED operating electronics integrated in ule for compensation of wall unevenness
housing — protection rating: IP65
— housing consisting of functional support, — insulation class: I
luminaire head and wall mount module, of
aluminum, powder-coated in Siteco®
FGNOP metallic gray (DB 702S); cover of
,PD[FGNOPDWγ • luminaire assembled for continuous row arrangements and through-wiring
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux
or power consumption can also change correspondingly. The latest values can be found in the photometric test report for the
& & specific products and in the current download files of the photometric planning data
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
1.22
1 Facade and path luminaires | Surface-mounted luminaires
l1 95
121
l 60
Downlight for wall surface mounting toughened safety glass, fits flush to
— light emission below; with Fresnel optics housing; luminaire head fixed to housing
for narrow or wide symmetric light via intelligent spring catch system; wall
distribution connection with Siteco® adjustment mod-
— LED operating electronics integrated in ule for compensation of wall unevenness
housing — protection rating: IP65
— housing consisting of functional support, — insulation class: I
luminaire head and wall mount module, of
aluminum, powder-coated in Siteco®
FGNOP metallic gray (DB 702S); cover of
,PD[FGNOPDWJ • luminaire assembled for continuous row arrangements and through-wiring
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux
or power consumption can also change correspondingly. The latest values can be found in the photometric test report for the
& & specific products and in the current download files of the photometric planning data
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
1.23
Facade and path luminaires | Surface-mounted luminaires 1
l1
60
121
l 95
Uplight or downlight for wall surface metallic gray (DB 702S); cover of tough-
mounting ened safety glass, fits flush to housing;
— light emission above or below; with luminaire head fixed to housing via
Fresnel optics for asymmetric light intelligent spring catch system; wall
distribution connection with Siteco® adjustment mod-
— LED operating electronics integrated in ule for compensation of wall unevenness
housing — protection rating: IP65
— housing consisting of functional support, — insulation class: I
luminaire head and wall mount module, of
FGNOP aluminum, powder-coated in Siteco®
,PD[FGNOPDWJ • luminaire assembled for continuous row arrangements and through-wiring
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux
or power consumption can also change correspondingly. The latest values can be found in the photometric test report for the
& & specific products and in the current download files of the photometric planning data
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
1.24
1 Facade and path luminaires | Surface-mounted luminaires
Housing
Sheet steel housing, white coated; PVC cover with brushed
nickel ring | splash-proof (IP44) | rapid, simple mounting
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest specific values can be found with the product in the electronic catalog.
1.25
Facade and path luminaires | Surface-mounted luminaires 1
70
298
Luminaire for wall and ceiling surface — sheet steel housing, white coated
mounting — cover of PVC with brushed nickel ring
— with opal cover — protection rating: IP44
— diffuse distribution with indirect accent light — insulation class: II
— with ECG
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
1.26
1 Facade and path luminaires | Surface-mounted luminaires
70
298
Luminaire for wall and ceiling surface — sheet steel housing, white coated
mounting — cover of PVC with brushed nickel ring
— with opal cover — protection rating: IP44
— diffuse distribution with indirect accent light — insulation class: II
— with ECG, light sensor and motion sensor
— sensor concealed away from view in
housing
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
1.27
Facade and path luminaires | Surface-mounted luminaires 1
1.28
1 Facade and path luminaires | Surface-mounted luminaires
Housing
Aluminum housing, black | glass cover | insulation class: I;
protection rating: IP44
1.29
Facade and path luminaires | Surface-mounted luminaires 1
91 93
101 97
86
DUO
1x OSRAM HALOPIN G9 2700 > 80 33 0.5 4052899901599 0NA74411EB216
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
1.30
1 Facade and path luminaires | Spotlights
CL LED Spotlight
The CL LED Spotlight 10 is an integral component of the
facade and path luminaires of the CL LED series. It can be
deployed as a ground, wall or ceiling spot. In terms of con-
struction design, the luminaire is reduced to a minimum with
a high level of workmanship: the housing consists completely
of diecast aluminum. The gaskets and glass cover fit flush
without joints. The spotlights of the CL LED series can be
adapted to a wide spectrum of photometric tasks with two
different light colors and various accessories.
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
1.31
Facade and path luminaires | Spotlights 1
102 215
169
CL LED Spotlight 10
$$:
[/('.&5,ƁI1OP
FGNOP Spotlight for ground, wall and ceiling — housing of aluminum, powder-coated in
mounting Siteco® metallic gray (DB 702S), can be
— rotationally symmetric narrow distribution; rotated through 180° and tilted through
with transparent cover; elliptical light 90° via patented fixing system; cover of
distribution and color accenting via toughened safety glass, fits flush to
additional filter discs housing
— LED operating electronics integrated in — protection rating: IP65
housing — insulation class: I
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux
or power consumption can also change correspondingly. The latest values can be found in the photometric test report for the
specific products and in the current download files of the photometric planning data
,PD[FGNOPDWJ
& &
D [ [
D [ [
Light source Order no. Order no.
+P ÕP (PD[O[ (PO[ OSRAM Siteco
LED 3000 > 80 1250 25 3.1 4050737462370 5AA322503W
LED 4000 > 80 1400 25 3.1 4050737462332 5AA322503N
1.32
1 Facade and path luminaires | Spotlights
102 215
169
100
300
CL LED Spotlight 10
$$:(
with ground stake
[/('.&5,ƁI1OP
FGNOP
& &
D [ [
D [ [
1.33
Facade and path luminaires | Spotlights 1
Ribbed disc
for subsequent mounting in CL Wall 10 MAXI and CL LED Spotlight 10 | ribbed structure for
elliptical light distribution | combination with color filter disc possible via innovative lay-in system
for subsequent mounting in CL Wall 10 MAXI and CL LED Spotlight 10 | very intensive color
rendering due to improved filter characteristics with less heating up of glass (compared to
conventional filter glass) | for color accenting of facades and paths | color filter of toughened
safety glass | combination with ribbed disc possible via innovative lay-in system
Color filters
for subsequent mounting in CL Wall 10 MAXI and CL LED Spotlight 10 | for color accenting of
facades and paths | color filter of toughened safety glass | combination with ribbed disc
possible via innovative lay-in system
1.34
1 Facade and path luminaires | Projectors
SiCOMPACT® R1 MINI
The rotationally symmetrical distribution projectors of the distribution can be selected for various photometric tasks.
SiCOMPACT® R1 MINI family can be mounted to the ground, Special effects are achieved with various color and diffuser
to walls, to masts or cross arms with suitable accessories. discs.
Highly specular aluminum reflectors with narrow or wide light
Features Electrics
— small projector for spotlighting and illumination of Luminaire wired ready for connection | with 3-pole
buildings connection terminal, max. 2.5mm² | cable entry for cable
— compact diecast aluminum housing with narrow or wide D = 7…14mm; optional protective tubing for cable to projec-
light distribution tor | with integral ballast (CCG, with parallel power-factor cor-
— with pressure equalization port preventing condensation in rection), spacially separated from lamp compartment
housing
— high light output ratio with compact design Housing
— all electrical components integrated in housing Housing of diecast aluminum; mounting bracket of galva-
nized steel (SiCOMPACT® R1 MINI-S) or diecast aluminum
Lighting technology (SiCOMPACT® R1 MINI-ALU); all parts coated in Siteco®
Highly specular aluminum reflector with rotationally symmet- metallic gray (DB 702S) | luminaire cover of toughened safety
ric light distribution, narrow or wide; elliptical, diamond- glass | insulation class: I | protection rating: IP65
shaped or diffuse light distribution via supplementary filter
disc, color accenting possible via dichroic color filters
1.35
Facade and path luminaires | Projectors 1
264
165
222
SiCOMPACT® R1 MINI-S
1;(+6
[+,7 &(:FIOP
FGNOP Projector with mounting bracket for — with CCG, parallel power-factor
mounting to cross arm, supporting structure correction and ignitor
or ground stake — housing of diecast aluminum; mounting
— with aluminum reflector, highly specular, bracket of galvanized steel; Siteco®
rotationally symmetric narrow or wide metallic gray (DB 702S); cover of
distribution; with flat cover disc; modifi- toughened safety glass
cation of lighting characteristic and color — protection rating: IP65
accenting via additional filter discs — insulation class: I
,PD[FGNOPDWJ
1.36
1 Facade and path luminaires | Projectors
236
ø198
ø168
330
450
293
37
ø120
,PD[FGNOPDWJ
1.37
Facade and path luminaires | Projectors 1
for subsequent mounting | structured glass with supporting frame of aluminum, Siteco®
metallic gray (DB 702S)
Ribbed disc: ribbed structure for elliptical light distribution
Pyramid disc: pyramidal structure for diamond-shaped light distribution
Diffuser disc: irregular surface structure for diffuse light distribution
for retrofitting | very intensive color rendering due to improved filter characteristics with less
heating up of glass (compared to conventional filter glass) | for color accenting of facades and
paths | color filter of toughened safety glass; supporting frame of aluminum, Siteco® metallic
gray (DB 702S)
for retrofitting | for color accenting of facades and paths | color filter of toughened safety glass;
supporting frame of aluminum, Siteco® metallic gray (DB 702S)
Baffle ring
for glare limitation when viewed directly | galvanized, coated black (RAL 9005, matt)
1.38
1 Facade and path luminaires | Projectors
Protection tube
for protection of cable to the projector | plastic, black | screw fastening on luminaire side |
length l = 600mm; diameter: d i = 17mm
steel, galvanized
for mounting the projector to masts with spigot size da = 76 x 70mm or on ground stake |
mast mounting element of diecast aluminum, Siteco® metallic gray (DB 702S)
for mounting the mast mounting element to masts with mast spigot da = 60mm | reducer of
diecast aluminum
1.39
Facade and path luminaires | Projectors 1
Ground stake
for accommodation of mast mounting element for projectors | ground stake of galvanized
steel | height: h = 500mm; spigot size da x l = 76 x 73mm
for mounting two projectors | cross arm of steel, galvanized | for spigot size
da = 76 x 100mm; cross arm L x W = 500 x 120mm
Wall bracket
for mounting projector | wall bracket of diecast aluminum, Siteco® metallic gray (DB 702S)
flat cover panel, mounted in housing ring | cover of toughened safety glass; housing ring of
diecast aluminum, Siteco® metallic gray (DB 702S)
1.40
1 Facade and path luminaires | Projectors
Siteco Mirrortec®
The rotationally symmetric Siteco Mirrortec® projector is char- The compact projector is manufactured of high-quality die-
acterized by a high light output ratio and narrow light distri- cast aluminum for easy handling: the projector head and the
bution without light spill. This is made possible with precise electrical housing, which additionally functions as a wall sur-
optics: with the parallel beam version, the inverse lamp posi- face mounting module, are separately constructed but con-
tion controls the beam area of ± 2.5 degrees with such a nected via a rotating hinge. This enables the projector head
high precision that the projectors are suitable as projector to be variably adjusted and securely fixed with three screws.
systems for the Siteco Mirrortec® reflectors as well as for the
precise point illumination of towers and buildings.
Features Electrics
— patented light control with inverse mounting position and Projector wired ready for connection | with 3-pole connection
axial lamp arrangement for parallel light distribution terminal, max. 2.5mm² | cable entry for cable D = 6…12mm |
— simple, discreet design with parallel power-factor correction CCG, with ignitor
— can be used indoors and outdoors
— compact construction with diecast aluminum housing Housing
— optimized housing design: no shadows from base or Housing of diecast aluminum, metallic gray (RAL 9006) |
lampholder projector head and electrical housing with pan-and-tilt con-
— tool-free relamping nection; temperature-resistant cover panel | plated and an-
odized aluminum reflector | tool-free relamping via opening of
Lighting technology upper tube hood | insulation class: I | protection rating: IP65
Due to patented lighting technology with inverse mounting
position, the beam area is precisely defined:
— Version 1: parallel distribution optimized for point-shaped
illumination from larger distances, maximum light output
ratio and uniform illumination in ± 8° beam area | signifi-
cantly reduced light immission with less than 1.6% of
luminous flux outside of range ± 10°
— Version 2: wide light distribution for floodlighting
1.41
Facade and path luminaires | Projectors 1
743 427
288 130
494
374
Siteco Mirrortec® Projector 400
1:5*
[+,7:FIOP
FGNOP for surface mounting to vertical or horizontal — housing of diecast aluminum, metallic
surfaces gray (RAL 9006); reflector of plated and
— patented lighting technology with inverse anodized aluminum, matt exterior; cover
mounting position; aluminum reflector, of toughened safety glass
highly specular, parallel or diffuse distri- — protection rating: IP65
bution; with transparent cover — insulation class: I
— with CCG, parallel power-factor correc- — application area: indoors or outdoors
tion and ignitor
,PD[FGNOPDWJ
— recommended lamps with 400W: OSRAM HQI-BT 400W
Note on lamp selection: when specifying lamps, the permissible lamp burning position must be considered (specification by lamp
manufacturer)
1.42
1 Facade and path luminaires | Recessed luminaires
AquaLED® 2
The durable and reliable AquaLED® 2 LED ground recessed
luminaires are a low-cost and complete family solution for
illuminating building vicinities in a functional and creative way.
The range consists of four construction sizes: S, M, L and
XL.
Features with narrow (10°) or wide light distribution (36°) | with frosted
— high flexibility due to family concept with various construc- cover, versions L and XL additionally with transparent cover
tion sizes, lumen packages, light colors and light distribu-
tion patterns Electrics
— light creates atmosphere: versions available with warm Ground recessing system for simple installation | luminaire
white and neutral white light, and for versions S and M wired ready for connection | with pre-installed connection
with blue light cable with free wire ends, 2/3 x 1.5mm² | prepared for
— long lifespan due to efficient LED technology through-wiring | with ECG for 230V, additionally 24V for
— good price/performance ratio versions S and M
— optimized LED thermal management for a long service life
and low thermal build-up at the light emission aperture Housing
Housing of PC (S and M), of diecast aluminum (L and XL) |
Lighting technology cover frame of stainless steel (V4A) | cover of PC (S and M),
High flexibility due to versions with varying lumen packages: of toughened safety glass (L and XL) | ground recessing
S (60 lumens), M (130 lumens), L (450 lumens) and XL (1,300 housing of PC, color: white | trip-safe due to low surface
lumens) | variable 0…30° inclination angle with versions L installation height (5mm) | surface temperature: T ≤ 40°C |
and XL | light color warm white (3,000K) or neutral white protection rating: IP67 | please order ground recessing
(4,000K), versions S and M additionally with blue | versions S housing separately
and M with uniform, diffuse light distribution (100°), L and XL
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
1.43
Facade and path luminaires | Recessed luminaires 1
ø 100
3
130
AquaLED® 2 S and AquaLED 2 M
for ground recessing | white light
Circular luminaire for ground recessing — housing of PC; cover frame of stainless
— orientation light with very homogeneous steel (V4A); cover of PC; recessing
light emission, white light, extremely wide housing of PC, white
light distribution; with frosted cover — protection rating: IP67
— with ECG — insulation class: II
— for 230V — impact resistance: IK08
— surface temperature: T ≤ 40°C
AquaLED 2 M
LED 3000 > 80 130 2.8 0.2 4008321988836 0XA97271WD200
LED 4000 > 80 130 2.8 0.2 4008321988843 0XA97271ND200
Accessories
1.44
1 Facade and path luminaires | Recessed luminaires
ø 100
3
130
AquaLED® 2 S and AquaLED® 2 M
for ground recessing | blue light
Circular luminaire for ground recessing — housing of PC; cover frame of stainless
— orientation light with very homogeneous steel (V4A); cover of PC; recessing
light emission, blue light, extremely wide housing of PC, white
light distribution; with frosted cover — protection rating: IP67
— with ECG — insulation class: II
— for 230V — impact resistance: IK08
— surface temperature: T ≤ 40°C
AquaLED 2 M
LED Blue 8400 > 80 130 2.8 0.2 4008321988850 0XA97271BD200
Accessories
1.45
Facade and path luminaires | Recessed luminaires 1
ø 100
3
130
AquaLED® 2 S and AquaLED® 2 M
for ground recessing | white light
Circular luminaire for ground recessing — housing of PC; cover frame of stainless
— orientation light with very homogeneous steel (V4A); cover of PC; recessing
light emission, white light, extremely wide, housing of PC, white
diffuse light distribution; with opal cover — protection rating: IP67
— for separate ECG — insulation class: III
— for 24V — impact resistance: IK08
— surface temperature: T ≤ 40°C
AquaLED 2 M
LED 3000 > 80 130 2.8 0.2 without CG 4008321988805 0XA97201WD200
LED 4000 > 80 130 2.8 0.2 without CG 4008321988812 0XA97201ND200
Accessories
1.46
1 Facade and path luminaires | Recessed luminaires
ø 100
3
130
AquaLED® 2 S and AquaLED® 2 M
for ground recessing | blue light
Circular luminaire for ground recessing — housing of PC; cover frame of stainless
— orientation light with very homogeneous steel (V4A); cover of PC; recessing
light emission, blue light, extremely wide, housing of PC, white
diffuse light distribution; with frosted — protection rating: IP67
cover — insulation class: III
— for separate ECG — impact resistance: IK08
— for 24V — surface temperature: T ≤ 40°C
AquaLED 2 M
LED Blue 8400 > 80 130 2.8 0.2 without CG 4008321988829 0XA97201BD200
Accessories
1.47
Facade and path luminaires | Recessed luminaires 1
ø 164
ø 92
5
117
153
AquaLED® 2 L
for ground recessing | narrow or wide distribution | white light
Circular luminaire for ground recessing toughened safety glass; ground recessing
— narrow (10°) or wide (36°) light distribu- housing of PC, white
tion; with variable inclination angle — protection rating: IP67
0…30°; with transparent or frosted cover — insulation class: I
— with ECG — impact resistance: IK09
— for 230V — surface temperature: T ≤ 40°C
— housing of diecast aluminum; cover frame
of stainless steel (V4A); cover of
Accessories
1.48
1 Facade and path luminaires | Recessed luminaires
ø152
ø239
5
152
187
AquaLED® 2 XL
for ground recessing | narrow or wide distribution | white light
Circular luminaire for ground recessing toughened safety glass; ground recessing
— narrow (10°) or wide (36°) light distribu- housing of PC, white
tion; with variable inclination angle — protection rating: IP67
0…30°; with transparent or frosted cover — insulation class: I
— with ECG — impact resistance: IK09
— for 230V — surface temperature: T ≤ 40°C
— housing of diecast aluminum; cover frame
of stainless steel (V4A); cover of
Accessories
1.49
Facade and path luminaires | Recessed luminaires 1
1.50
1 Facade and path luminaires | Recessed luminaires
CW
The cuboid and cylindrical recessed wall luminaires of the accessory glasses. The luminaire cover for both luminaire
CW family with rectangular or circular light emission aper- types is opal safety glass (optional: transparent cover) with a
tures provide a symmetric light distribution. A silver-gray anti- cover ring of stainless steel or diecast aluminum.
glare screen enables direct, glare-limited light control. Special
color effects can be achieved with CW 91 with suitable color
Features Electrics
— recessed wall luminaire with circular or rectangular design Luminaire wired ready for connection | with 3-pole
with opal glass cover and stainless steel frame connection terminal, max. 2.5mm² | cable entry for cable
— CW 96: narrow optics with good, linear light effect D = 7…14mm (CW 91: can be optionally supplied with cable
— recessed casing and cover ring of stainless steel entry for 2 cables for 3x max. 1.5mm² through-wiring) |
— optional color glasses/transparent cover glass/anti-glare versions for compact fluorescent lamp with CCG, parallel
screen available power-factor correction
— optional through-wiring
Housing
Lighting technology Encapsulated housing of diecast aluminum; cover of temper-
Aluminum reflector, highly specular, symmetric light distribu- ature-resistant toughened safety glass, frame of stainless
tion; luminaire with opal cover of toughened safety glass steel or coated aluminum, silver-gray | insulation class: I |
(transparent cover by on-site replacement) protection rating: IP66
For CW 91: elliptical light distribution via supplementary filter Wall recessing frame of stainless steel, open at rear, with
disc, color accenting possible via dichroic color filters mounting frame of diecast aluminum
1.51
Facade and path luminaires | Recessed luminaires 1
ø 240 145 2
105
ø 225
CW 91
/$)$
for wall recessing
[7&':IOP
Circular luminaire for wall recessing — cover frame of stainless steel or diecast
— with aluminum reflector, highly specular, aluminum, silver-gray coated; cover of
symmetric light distribution; with opal safety glass; mounting frame of stainless
cover*; glare reduction and color accent- steel with mounting ring of diecast
ing via supplementary screen or filter aluminum, silver-gray coated
— versions for compact fluorescent lamps: — protection rating: IP66
with CCG, power-factor correction — insulation class: I
— housing of extruded aluminum
* opal cover can be replaced on site by transparent cover
FGNOP
,PD[FGNOPDWJ
& &
— please order transparent cover panel, color filters or screen separately if required
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
0RXQWLQJKHLJKWP7LOW
O[
Accessories (for details see page 1.58 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Color disc, dichroic, red 0.1 4039806210371 5NX90000XG03
Color disc, dichroic, yellow 0.1 4039806207432 5NX90000XG42
Color disc, dichroic, green 0.1 4039806207418 5NX90000XG02
Color disc, dichroic, blue 0.1 4039806207425 5NX90000XG04
Cover, transparent glass 1.0 4039806374011 5NX90000XG01
P
1.52
1 Facade and path luminaires | Recessed luminaires
259 140
105
67x242
84
2
CW 96
/$0
for wall recessing
[47 '(:IOP
Rectangular luminaire for wall recessing — housing of diecast aluminum; cover frame
— with aluminum reflector, highly specular, of stainless steel; mounting frame of
symmetric light distribution; depending stainless steel with mounting ring of
on version with screen for glare reduction; diecast aluminum, silver-gray coated
with opal safety glass cover — protection rating: IP66
— versions for compact fluorescent lamps: — insulation class: I
with CCG, with power-factor correction
,PD[FGNOPDWJ
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
/LFKWSXQNWKÓKHP1HLJXQJ
O[
P
1.53
Facade and path luminaires | Recessed luminaires 1
1.54
1 Facade and path luminaires | Recessed luminaires
CB
The cuboid and cylindrical ground recessed luminaires of the wallwashers. The application range is extended with an anti-
CB family with rectangular or circular light emission apertures glare screen (CB 90) and various dichroic color glasses for
and various reflector systems provide a narrow, medium or retrofitting. The solid ground recessed luminaires with stain-
wide light distribution. With an insert for asymmetric light dis- less steel recessed housing and toughened safety glass can
tribution (CB 95) and an angle of inclination adjustment to withstand driveover loads of up to 5,000 or 6,000kg.
10° (CB 90), the CB luminaires can also be used as
Features Electrics
— driveover load 5,000kg (CB 90) or 6,000kg (CB 95) Luminaire wired ready for connection | with pre-installed con-
— cover of toughened safety glass; optionally anti-slip nection cable with free wire ends, 3x 1.5mm², L = 1m, for
— minimal construction height of stainless steel frame connection of on-site connection socket | with CCG, parallel
— optional color glasses power-factor correction, gearbox in separate housing with
— ground recessing frame of stainless steel CB 90, with fixed wiring to luminaire head
— pre-assembled connection cable
Housing
Lighting technology Encapsulated housing of diecast aluminum; cover of temper-
Highly specular aluminum reflector; luminaire with transparent ature-resistant toughened safety glass, frame of stainless
cover of toughened safety glass (opal or transparent anti-slip steel or coated aluminum, silver-gray | maximum planar drive-
cover by replacing on-site); color accenting possible via di- over load: CB 90 up to 5,000kg; CB 95 up to 6,000kg | insu-
chroic color filters | CB 90 with extremely narrow, medium or lation class: I | protection rating: IP67 | ground recessing
wide light distribution, with 0…10° alignment adjustment of frame of stainless steel, open at rear, with mounting frame of
reflector system | CB 95 with asymmetric or symmetric light diecast aluminum
distribution
1.55
Facade and path luminaires | Recessed luminaires 1
ø240
380
>300
ø225
CB 90
1$065
for ground recessing
[+,7 &(:FIOP
FGNOP
Circular luminaire for ground recessing — housing of diecast aluminum; cover frame
— with aluminum reflector, highly specular, of stainless steel; cover of safety glass;
extremely narrow, narrow or medium light mounting frame of stainless steel with
distribution; with variable 0…10° lamp in- mounting ring of diecast aluminum,
clination angle; with transparent cover*; silver-gray coated
glare reduction and color accenting via — protection rating: IP67
supplementary screen or filter — insulation class: I
— versions for compact fluorescent lamps: — incl. pre-assembled connection cable,
with CCG, with power-factor correction L = 1m
* transparent cover can be replaced on site by slip-resistant cover or opal cover
,PD[FGNOPDWJ
narrow distribution
1x HIT | HIT-CE 35 W G12 8.2 4039806420176 5NA90011LB100R
1x HIT | HIT-CE 70 W G12 8.5 4039806205575 5NA90011MB100R
1x HIT | HIT-CE 150 W G12 9.1 4039806205643 5NA90011PB100R
1x TC-T 26 W GX24d-3 7.3 4039806246349 5LA90011LA100
medium distribution
1x HIT | HIT-CE 35 W G12 8.0 4039806420190 5NA90011LS100R
1x HIT | HIT-CE 70 W G12 8.5 4039806205612 5NA90011MS100R
1x HIT | HIT-CE 150 W G12 9.1 4039806205681 5NA90011PS100R
— please order opal or slip-resistant cover panel, color filter or screen separately if required
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
175
350
2
h1
h
>300
333x160
CB 95
1$1$
for ground recessing
[+,7 '(K:IOP
FGNOP
Rectangular luminaire for ground recessing mounting frame of stainless steel with
— with aluminum reflector, highly specular, mounting ring of diecast aluminum,
symmetric or asymmetric light distribu- silver-gray coated
tion; with transparent cover*; color ac- — protection rating: IP67
centing via supplementary filter disc — insulation class: I
— with CCG, with power-factor correction — incl. pre-assembled connection cable,
— housing of diecast aluminum; cover frame L = 1m
of stainless steel; cover of safety glass;
* transparent cover can be replaced on site by slip-resistant cover or opal cover
,PD[FGNOPDWJ
symmetric distribution
1x HIT-DE-CE | HST-DE 70 W RX7s 195 155 7.2 4039806205704 5NA95011NS100
1x HIT-DE-CE | HST-DE 150W RX7s-24 330 275 9.7 4039806205728 5NA95011PS100
— please order opal or slip-resistant cover panel or color filter separately if required
1.57
Facade and path luminaires | Recessed luminaires 1
for retrofitting in CW 91 and CB 90 | very intensive color rendering due to improved filter
characteristics with less heating up of glass (compared to conventional filter glass) | for color
accenting of facades and paths
Ring louver
for glare reduction | for retrofitting in CB 90 | for high-pressure lamps (HIT 35/70/150W)
For CW 91
Transparent | safety glass 4039806374011 5NX90000XG01
Opal | safety glass 4039806241092 5NX90000XG00
For CB 90
Transparent, anti-slip | safety glass 4039806223005 5NX90000XG00R
Transparent | safety glass 4039806374011 5NX90000XG01
Opal | safety glass 4039806241092 5NX90000XG00
1.58
1 Facade and path luminaires | Recessed luminaires
for retrofitting in CW 95 | very intensive color rendering due to improved filter characteristics
with less heating up of glass (compared to conventional filter glass) | for color accenting of
facades and paths
as replacement of series cover for CB 95 transparent, anti-slip due to partly roughed surface |
safety glass, pressure-resistant with surface loads | transparent | safety glass – opal | safety
glass
For CB 95
Transparent, anti-slip | safety glass 4039806223012 5NX95000XG00R
Transparent | safety glass 4039806374028 5NX95000XG01
Opal | safety glass 4039806241108 5NX95000XG00
1.59
Facade and path luminaires | Recessed luminaires 1
1.60
1 Facade and path luminaires | Bollards and pillars
CL LED Bollard
The CL LED Bollard 30 | … 60 | … 90 and … 120 are integral
components of the facade and path luminaires of the CL LED
series. The bollards consist of two components: a base with
integrated gear tray and the fully integrated LED light source,
and the housing with reflector in the various construction
sizes. The housing is completely of diecast aluminum, and
gaskets and PC cover panel fit flush without joints. Light dis-
tribution of the bollard is via a secondary system. This results
in highly homogeneous, harmonious and glare-free planar il-
lumination, optionally via one or two light emission apertures.
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
1.61
Facade and path luminaires | Bollards and pillars 1
ø125
134
356
CL LED Bollard 30
$$:
[/('.&5,ƁI1OP
Bollard for mounting on foundation or — aluminum housing, solid base with
planted section integrated gear tray; powder-coated in
— with one or two-sided light emission; with Siteco® metallic gray (DB 702S); cover of
secondary reflector system for glare-free impact-resistant PC
illumination; with transparent cover — protection rating: IP65
— LED operating electronics integrated in — insulation class: I
housing — impact resistance: IK10
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux
or power consumption can also change correspondingly. The latest values can be found in the photometric test report for the
specific products and in the current download files of the photometric planning data
,PD[FGNOPDWJ
& &
— please see the notes on the EU directive concerning energy labeling of electrical lamps and luminaires (EU) 874/2012 on page 9.15
0RXQWLQJKHLJKWP7LOW
O[
P
1.62
1 Facade and path luminaires | Bollards and pillars
ø125
134
682
CL LED Bollard 60
$$:
[/('.&5,ƁI1OP
Bollard for mounting on foundation or — aluminum housing, solid base with
planted section integrated gear tray; powder-coated in
— with one or two-sided light emission; with Siteco® metallic gray (DB 702S); cover of
secondary reflector system for glare-free impact-resistant PC
illumination; with transparent cover — protection rating: IP65
— LED operating electronics integrated in — insulation class: II
housing — impact resistance: IK10
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or
power consumption can also change correspondingly. The latest values can be found in the photometric test report for the specific
products and in the current download files of the photometric planning data
,PD[FGNOPDWJ
& &
0RXQWLQJKHLJKWP7LOW
O[
P
1.63
Facade and path luminaires | Bollards and pillars 1
ø125
134
880
CL LED Bollard 90
$$:
[/('.&5,ƁI1OP
Bollard for mounting on foundation or — aluminum housing, solid base with
planted section integrated gear tray; powder-coated in
— with one or two-sided light emission; with Siteco® metallic gray (DB 702S); cover of
secondary reflector system for glare-free impact-resistant PC
illumination; with transparent cover — protection rating: IP65
— LED operating electronics integrated in — insulation class: II
housing — impact resistance: IK10
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux
or power consumption can also change correspondingly. The latest values can be found in the photometric test report for the
specific products and in the current download files of the photometric planning data
,PD[FGNOPDWJ
& &
0RXQWLQJKHLJKWP7LOW
O[
P
1.64
1 Facade and path luminaires | Bollards and pillars
ø125
340
1207
CL LED Bollard 120
$$:
[/('.&5,ƁI1OP
Bollard for mounting on foundation or — aluminum housing, solid base with
planted section integrated gear tray; powder-coated in
— with one or two-sided light emission; with Siteco® metallic gray (DB 702S); cover of
secondary reflector system for glare-free impact-resistant PC
illumination; with transparent cover — protection rating: IP65
— LED operating electronics integrated in — insulation class: II
housing — impact resistance: IK10
• rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux
or power consumption can also change correspondingly. The latest values can be found in the photometric test report for the
specific products and in the current download files of the photometric planning data
,PD[FGNOPDWJ
& &
0RXQWLQJKHLJKWP7LOW
O[
P
1.65
Facade and path luminaires | Bollards and pillars 1
Planted section
for safe anchorage of bollard luminaire in various grounds | planted sections of steel,
galvanized | with suitable aperture ring for fixing luminaire
for 1 or 2 feeder cables to 4 x 10mm² or 3 cables to 4 x 6mm² | with one D01 fuse base with
E14 screw cap | housing of PC | IP43 | insulation class II
1.66
1 Facade and path luminaires | Bollards and pillars
The LED bollard and pillar luminaires of the CITY-LIGHT The LED Module 520 is equipped with microprocessor-
family can adapt to a wide variety of lighting tasks. With controlled LED operating electronics. This makes available a
intelligently graded construction sizes and a modern design series of functions. These have been combined into three
they blend harmoniously with their architectural surroundings. performance packages: “Basic”, “Plus” and “Premium”. All
make use of the outstanding property of LED light sources in
With the LED versions of this luminaire family, the classic reducing luminous flux without loss. These values are either
electrical insert has been replaced by the LED Module 520 factory-set (“Basic” package), can be individually set with the
especially developed by Siteco for this purpose. The modular Siteco® Service Box (“Plus” package) or centrally set via
construction ensures that forthcoming, more modern LED Street Light Control (“Premium” package). The “Plus” and
generations with higher performance levels can be upgraded “Premium” versions offer the widest spectrum of efficient
later with ease. control of LED luminaires according to requirements.
The glare-free, directed light distribution is achieved via a Most optical components and electrical inserts and the LED
precisely matched combination of high-performance LEDs, Module 520 for this luminaire family can be interchanged and
optical lens systems, highly specular reflectors and transpar- are identical to components of the lantern-design town and
ent luminaire enclosures. The LED Module 520 has symmet- park luminaires, enabling outstanding availability of replace-
ric or asymmetric light distribution and is available either with ment parts and the rapid, maintenance-friendly exchange of
warm white or neutral white color temperature. components for greater flexibility for design.
New:
LED town and parc luminaires with new LED Module 540
Ready for order: Q3/2014
Detailed information
www.siteco.com/LEDModule540
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
1.67
Facade and path luminaires | Bollards and pillars 1
1.68
1 Facade and path luminaires | Bollards and pillars
ø200
500
1200
CITY-LIGHT 120 LED
;$:6
Bollard | symmetric distribution
[/('.&5,ƁI1OP
— please order the 'bollard cable set' separately for configuration of the LED module, “Plus” version with the installed luminaire
— please order junction box separately
— please order planted section separately if required
0RXQWLQJKHLJKWP7LOW
O[
P
1.69
Facade and path luminaires | Bollards and pillars 1
ø200
500
1200
CITY-LIGHT 120 LED
;$:$
Bollard | asymmetric distribution
[/('.&5,ƁI1OP
— please order the 'bollard cable set' separately for configuration of the LED module, “Plus” version with the installed luminaire
— please order junction box separately
— please order planted section separately if required
OSRAM Siteco
Bollard cable set, L = 1m, for “Plus” version 0.3 4050737028866 5EA6Y00L05
Siteco® Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
Cable junction box 0.5 4039806199973 5NY70012XK
P
1.70
1 Facade and path luminaires | Bollards and pillars
ø200
600
1300
CITY-LIGHT 120 E LED
;$:6
Bollard | symmetric distribution
[/('.&5,ƁI1OP
— please order the 'bollard cable set' separately for configuration of the LED module, “Plus” version with the installed luminaire
— please order junction box separately
— please order planted section separately if required
0RXQWLQJKHLJKWP7LOW
O[
Accessories (for details see page 1.84 ff.)
P
1.71
Facade and path luminaires | Bollards and pillars 1
ø200
600
1300
CITY-LIGHT 120 E LED
;$:$
Bollard | asymmetric distribution
[/('.&5,ƁI1OP
— please order the 'bollard cable set' separately for configuration of the LED module, “Plus” version with the installed luminaire
— please order junction box separately
— please order planted section separately if required
OSRAM Siteco
Bollard cable set, L = 1m, for “Plus” version 0.3 4050737028866 5EA6Y00L05
Siteco® Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
Cable junction box 0.5 4039806199973 5NY70012XK
P
1.72
1 Facade and path luminaires | Bollards and pillars
ø200
500
1200
CITY-LIGHT 120
1$(061$;6
Bollard
[+6(://IOP
10
& &
/XPLQRXVLQWHQVLW\FODVV
Light source Order no. Order no.
DFFRUGLQJWR
(1* OSRAM Siteco
PMMA, transparent
1x HSE 50 W 1) E27 11.0 4039806348579 5NA528E1MS28
1x HSE 70 W E27 X 11.2 4039806348470 5NA528E1MR28
2x TC-LEL 18/24 W 2G11 11.0 4039806280367 5LA52822KS28
PMMA, frosted
1x HSE 50 W 1) E27 11.0 4039806348593 5NA528E1MS38
1x HSE 70 W E27 X 11.2 4039806348494 5NA528E1MR38
2x TC-LEL 18/24 W 2G11 11.0 4039806280381 5LA52822KS38
P
1.73
Facade and path luminaires | Bollards and pillars 1
ø200
600
1300
CITY-LIGHT 120 E
1$(061$;6
Bollard
[+6(://IOP
10
& &
/XPLQRXVLQWHQVLW\FODVV
Light source Order no. Order no.
DFFRUGLQJWR
(1* OSRAM Siteco
PMMA, transparent
1x HSE 50 W 1) E27 10.9 4039806348616 5NA528E1MS58
1x HSE 70 W E27 X 11.0 4039806348531 5NA528E1MR58
2x TC-LEL 18/24 W 2G11 10.8 4039806280404 5LA52822KS58
PMMA, frosted
1x HSE 50 W 1) E27 10.8 4039806348630 5NA528E1MS68
1x HSE 70 W E27 X 11.0 4039806348555 5NA528E1MR68
2x TC-LEL 18/24 W 2G11 10.8 4039806280428 5LA52822KS68
P
1.74
1 Facade and path luminaires | Bollards and pillars
ø20
500
2600
CITY-LIGHT 260 LED
;$:6
Pillar | symmetric distribution
[/('.&5,ƁI1OP
Pillar for mounting on foundation or planted differing control function for light
section management and monitoring*
— with white LEDs, symmetric distribution; — housing and canopy element of diecast
with light dispersing element for lumi- aluminum, Siteco® metallic gray
nance reduction; with transparent cover (DB 702S); cover of PMMA
— microprocessor-controlled LED operating — protection rating: IP54
electronics; depending on version with — insulation class: II
* all versions with temperature monitoring for protection of LEDs from thermal overload
• “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
FGNOP
• “Plus” version: with luminous flux constancy over complete service life | with integrated, programmable timer for luminous flux
reduction at two levels | settable luminous flux for max. operation and for both reduction levels | all parameters can be set
with the Service Box | on request: can be integrated via SDI into existing digital control systems and controlled from a central
control point | alternatively: luminous flux reduction via 230V control voltage
& & • “Premium” version: functional range as with “Plus” version, but for individual monitoring and control of the luminaire from a
central control point from any distance via LON PowerLine without supplementary control wire (instead of SDI)
/XPLQRXVLQWHQVLW\FODVV • Luminaire can be operated with factory pre-setting. The pre-setting with the “Plus” and “Premium” versions can be modified
DFFRUGLQJWR with the mounted or dismantled luminaire
(1*
— please order the 'pillar cable set' separately for configuration of the LED module, “Plus” version with the installed luminaire
— please order junction box separately
— please order planted section separately if required
0RXQWLQJKHLJKWP7LOW
O[
Accessories (for details see page 1.84 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Pillar cable set, L = 2m, for “Plus” version 0.6 4050737028897 5EA6Y00L06
Siteco® Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
Cable junction box 0.5 4039806199973 5NY70012XK
P
1.75
Facade and path luminaires | Bollards and pillars 1
ø20
500
2600
CITY-LIGHT 260 LED
;$:$
Pillar | asymmetric distribution
[/('.&5,ƁI1OP
Pillar for mounting on foundation or planted differing control function for light
section management and monitoring*
— with white LEDs, asymmetric distribution, — housing and canopy element of diecast
without light spill to the rear; with light aluminum, Siteco® metallic gray
dispersing element for luminance (DB 702S); cover of PMMA
reduction; with transparent cover — protection rating: IP54
— microprocessor-controlled LED operating — insulation class: II
electronics; depending on version with
* all versions with temperature monitoring for protection of LEDs from thermal overload
FGNOP • “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
• “Plus” version: with luminous flux constancy over complete service life | with integrated, programmable timer for luminous flux
reduction at two levels | settable luminous flux for max. operation and for both reduction levels | all parameters can be set
with the Service Box | on request: can be integrated via SDI into existing digital control systems and controlled from a central
& &
control point | alternatively: luminous flux reduction via 230V control voltage
• “Premium” version: functional range as with “Plus” version, but for individual monitoring and control of the luminaire from a
/XPLQRXVLQWHQVLW\FODVV central control point from any distance via LON PowerLine without supplementary control wire (instead of SDI)
DFFRUGLQJWR • Luminaire can be operated with factory pre-setting. The pre-setting with the “Plus” and “Premium” versions can be modified
(1 with the mounted or dismantled luminaire
— please order the 'pillar cable set' separately for configuration of the LED module, “Plus” version with the installed luminaire
— please order junction box separately
— please order planted section separately if required
Pillar cable set, L = 2m, for “Plus” version 0.6 4050737028897 5EA6Y00L06
Siteco® Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
Cable junction box 0.5 4039806199973 5NY70012XK
P
1.76
1 Facade and path luminaires | Bollards and pillars
ø200
600
2680
CITY-LIGHT 260 E LED
;$:6
Pillar | symmetric distribution
[/('.&5,ƁI1OP
Pillar for mounting on foundation or planted differing control function for light
section management and monitoring*
— with white LEDs, symmetric distribution; — housing and canopy element of diecast
with light dispersing element for lumi- aluminum, Siteco® metallic gray
nance reduction; with transparent cover (DB 702S); cover of PMMA
— microprocessor-controlled LED operating — protection rating: IP54
electronics; depending on version with — insulation class: II
* all versions with temperature monitoring for protection of LEDs from thermal overload
• “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
FGNOP
• “Plus” version: with luminous flux constancy over complete service life | with integrated, programmable timer for luminous flux
reduction at two levels | settable luminous flux for max. operation and for both reduction levels | all parameters can be set
with the Service Box | on request: can be integrated via SDI into existing digital control systems and controlled from a central
control point | alternatively: luminous flux reduction via 230V control voltage
& & • “Premium” version: functional range as with “Plus” version, but for individual monitoring and control of the luminaire from a
central control point from any distance via LON PowerLine without supplementary control wire (instead of SDI)
/XPLQRXVLQWHQVLW\FODVV • Luminaire can be operated with factory pre-setting. The pre-setting with the “Plus” and “Premium” versions can be modified
DFFRUGLQJWR with the mounted or dismantled luminaire
(1*
— please order the 'pillar cable set' separately for configuration of the LED module, “Plus” version with the installed luminaire
— please order junction box separately
— please order planted section separately if required
0RXQWLQJKHLJKWP7LOW
O[
Accessories (for details see page 1.84 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Pillar cable set, L = 2m, for “Plus” version 0.6 4050737028897 5EA6Y00L06
Siteco® Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
Cable junction box 0.5 4039806199973 5NY70012XK
P
1.77
Facade and path luminaires | Bollards and pillars 1
ø200
600
2680
CITY-LIGHT 260 E LED
;$:$
Pillar | asymmetric distribution
[/('.&5,ƁI1OP
Pillar for mounting on foundation or planted differing control function for light
section management and monitoring*
— with white LEDs, asymmetric distribution; — housing and canopy element of diecast
with light dispersing element for lumi- aluminum, Siteco® metallic gray
nance reduction; with transparent cover (DB 702S); cover of PMMA
— microprocessor-controlled LED operating — protection rating: IP54
electronics; depending on version with — insulation class: II
* all versions with temperature monitoring for protection of LEDs from thermal overload
• “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
FGNOP
• “Plus” version: with luminous flux constancy over complete service life | with integrated, programmable timer for luminous flux
reduction at two levels | settable luminous flux for max. operation and for both reduction levels | all parameters can be set
with the Service Box | on request: can be integrated via SDI into existing digital control systems and controlled from a central
control point | alternatively: luminous flux reduction via 230V control voltage
& & • “Premium” version: functional range as with “Plus” version, but for individual monitoring and control of the luminaire from a
central control point from any distance via LON PowerLine without supplementary control wire (instead of SDI)
/XPLQRXVLQWHQVLW\FODVV • Luminaire can be operated with factory pre-setting. The pre-setting with the “Plus” and “Premium” versions can be modified
DFFRUGLQJWR with the mounted or dismantled luminaire
(1
— please order the 'pillar cable set' separately for configuration of the LED module, “Plus” version with the installed luminaire
— please order junction box separately
— please order planted section separately if required
OSRAM Siteco
Pillar cable set, L = 2m, for “Plus” version 0.6 4050737028897 5EA6Y00L06
Siteco® Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
Cable junction box 0.5 4039806199973 5NY70012XK
P
1.78
1 Facade and path luminaires | Bollards and pillars
ø200
500
2600
700
600
CITY-LIGHT 260 D LED
;$:6'
Pillar | symmetric distribution, with supplementary light emission near to ground
[/('.&5,ƁI1OP
Pillar for mounting on foundation or planted differing control function for light
section management and monitoring*; secondary
— with white LEDs, symmetric distribution; light emission with ECG
with light dispersing element for lumi- — housing and canopy element of diecast
nance reduction; with transparent cover; aluminum, Siteco® metallic gray
with secondary light emission via opal (DB 702S); cover of PMMA
cover near to ground — protection rating: IP54
— microprocessor-controlled LED operating — insulation class: II
electronics; depending on version with
FGNOP
* all versions with temperature monitoring for protection of LEDs from thermal overload
• “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
• “Plus” version: with luminous flux constancy over complete service life | with integrated, programmable timer for luminous flux
& & reduction at two levels | settable luminous flux for max. operation and for both reduction levels | all parameters can be set
with the Service Box | on request: can be integrated via SDI into existing digital control systems and controlled from a central
/XPLQRXVLQWHQVLW\FODVV control point | alternatively: luminous flux reduction via 230V control voltage
DFFRUGLQJWR • “Premium” version: functional range as with “Plus” version, but for individual monitoring and control of the luminaire from a
central control point from any distance via LON PowerLine without supplementary control wire (instead of SDI)
(1*
• Luminaire can be operated with factory pre-setting. The pre-setting with the “Plus” and “Premium” versions can be modified
with the mounted or dismantled luminaire
Accessories (for details see page 1.84 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Pillar cable set, L = 2m, for “Plus” version 0.6 4050737028897 5EA6Y00L06
Siteco® Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P Cable junction box 0.5 4039806199973 5NY70012XK
1.79
Facade and path luminaires | Bollards and pillars 1
ø200
500
2600
700
600
CITY-LIGHT 260 D LED
;$:$'
Pillar | asymmetric distribution, with supplementary light emission near to ground
[/('.&5,ƁI1OP
Pillar for mounting on foundation or planted differing control function for light manage-
section ment and monitoring*; secondary light
— with white LEDs, asymmetric distribution, emission with ECG
without light emission to the rear; with — housing and canopy element of diecast
light dispersing element for luminance aluminum, Siteco® metallic gray
reduction; with transparent cover; with (DB 702S); cover of PMMA
secondary light emission via opal cover — protection rating: IP54
near to ground — insulation class: II
— microprocessor-controlled LED operating
FGNOP electronics; depending on version with
* all versions with temperature monitoring for protection of LEDs from thermal overload
• “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
& & • “Plus” version: with luminous flux constancy over complete service life | with integrated, programmable timer for luminous flux
reduction at two levels | settable luminous flux for max. operation and for both reduction levels | all parameters can be set
/XPLQRXVLQWHQVLW\FODVV with the Service Box | on request: can be integrated via SDI into existing digital control systems and controlled from a central
DFFRUGLQJWR control point | alternatively: luminous flux reduction via 230V control voltage
(1 • “Premium” version: functional range as with “Plus” version, but for individual monitoring and control of the luminaire from a
central control point from any distance via LON PowerLine without supplementary control wire (instead of SDI)
• Luminaire can be operated with factory pre-setting. The pre-setting with the “Plus” and “Premium” versions can be modified
with the mounted or dismantled luminaire
— please order the 'pillar cable set' separately for configuration of the LED module, “Plus” version with the installed luminaire
— please order junction box separately
— please order planted section separately if required
Mounting height 2.35m Tilt 0°
0RXQWLQJKHLJKWP7LOW
O[ Accessories (for details see page 1.84 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Pillar cable set, L = 2m, for “Plus” version 0.6 4050737028897 5EA6Y00L06
P
Siteco® Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
Cable junction box 0.5 4039806199973 5NY70012XK
1.80
1 Facade and path luminaires | Bollards and pillars
ø20
500
2600
CITY-LIGHT 260
1$(061$;6
Pillar
[+6(://IOP
Pillar for mounting on foundation or planted fan-shaped reflector with light distribution
section directed downwards
— open distribution, with transparent or — with CCG, power-factor correction, with
frosted cover depending on version; power reduction depending on version*
symmetric wide distribution via fan- — housing and canopy element of diecast
shaped reflector or shield, asymmetric aluminum, Siteco® metallic gray
wide distribution (with reduced light (DB 702S); cover of PMMA
emission to the rear) via fan-shaped — protection rating: IP54
reflector with shielding on building side; — insulation class: II
FGNOP
* power reduction via 230V control voltage
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
PMMA, transparent
1x HSE 50 W 1) E27 21.2 4039806350343 5NA529E1MS28
1x HSE 70 W E27 X 21.4 4039806350237 5NA529E1MR28
2x TC-LEL 18/24 W 2G11 21.2 4039806280565 5LA52922KS28
PMMA, frosted
1x HSE 50 W 1) E27 21.2 4039806350374 5NA529E1MS38
1x HSE 70 W E27 X 21.3 4039806350268 5NA529E1MR38
2x TC-LEL 18/24 W 2G11 21.1 4039806280596 5LA52922KS38
P
1.81
Facade and path luminaires | Bollards and pillars 1
ø200
600
2680
CITY-LIGHT 260 E
1$(061$;6
Pillar
[+6(://IOP
Pillar in cylindrical form for mounting on fan-shaped reflector with light distribution
foundation or planted section directed downwards
— open distribution, with transparent or — with CCG, power-factor correction, with
frosted cover depending on version; power reduction depending on version*
symmetric wide distribution via fan- — housing and canopy element of diecast
shaped reflector or shield, asymmetric aluminum, Siteco® metallic gray
wide distribution (with reduced light (DB 702S); cover of PMMA
emission to the rear) via fan-shaped — protection rating: IP54
reflector with shielding on building side; — insulation class: II
FGNOP
* power reduction via 230V control voltage
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
PMMA, transparent
1x HSE 50 W 1) E27 16.6 4039806350398 5NA529E1MS58
1x HSE 70 W E27 X 16.7 4039806350305 5NA529E1MR58
PMMA, frosted
1x HSE 50 W 1) E27 16.5 4039806350411 5NA529E1MS68
1x HSE 70 W E27 X 16.7 4039806350329 5NA529E1MR68
P
1.82
1 Facade and path luminaires | Bollards and pillars
ø200
500
2600
700
600
CITY-LIGHT 260 D
1$(06'1$;6
Pillar | with supplementary light emission near to ground
[+6(://IOP
Pillar for mounting on foundation or planted directed downwards; with secondary light
section emission via opal cover near to ground
— open distribution, with transparent or — with CCG, power-factor correction, with
frosted cover depending on version; power reduction* depending on version;
symmetric wide distribution via fan- secondary light emission with ECG
shaped reflector or shield, asymmetric — aluminum housing; glass-fiber-reinforced
wide distribution (with reduced light polyester canopy element; housing and
emission to the rear) via fan-shaped canopy in Siteco® metallic gray
reflector with shielding on building side; (DB 702S); cover of PMMA
FGNOP fan-shaped reflector with light distribution — protection rating: IP54
— insulation class: II
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR 10
(1*
P
1.83
Facade and path luminaires | Bollards and pillars 1
for parameterizing the operating electronics of all “Plus” version Siteco® LED road luminaires |
maximum energy efficiency via individual adaptation of lighting level, switching time and re-
duction level | setting of static colors and dynamic color sequences with suitable luminaires |
software* included with Service Box | with plug-in coupling for connecting Y-cable | plastic
housing; plug-in coupling with protection cap | IP54 | insulation class II
for wiring of junction box in mast to LED Module 520 (“Plus” version) in the mounted luminaire
| with 5-pole plug-in coupling for integration of Siteco® Service Box, for manual parameteriza-
tion of luminaire (e.g. luminous flux, timer etc.)
for 2 feeder cables to 5x 16mm² or 3 cables to 5x 10mm² | two D01 fuse bases with E14
screw caps | plastic housing, IP44 | insulation class II
— for further versions (connection options, fusing, protection rating) please see the "Accessories" section
1.84
1 Facade and path luminaires | Bollards and pillars
Planted section
for safe anchorage of bollard or pillar in foundation or concentrated ground | planted section
of steel, galvanized | with suitable aperture ring for fixing luminaire
Dimensions: da x h = 255 x 485mm
Optical enclosure
transparent | PMMA (LED modules provide best efficiency with luminaires with transparent
covers)
Fan-shaped reflector
for all lamp types (HSE, TC-LEL) | symmetric illumination | incl. anti-glare ring for covering
control gear block
for 2 feeder cables to 5x 16 mm² or 3 cables to 5x 10 mm² | two D01 fuse bases with E14
screw caps | plastic housing | IP44 | insulation class II
— for further versions (connection options, fusing, protection rating) please see the "Accessories" section
1.85
Facade and path luminaires | Bollards and pillars 1
Fan-shaped reflector
for high-pressure lamps (1x HSE 50/70/100W) | symmetric distribution, or asymmetric (with
shielding on building side) | incl. anti-glare ring for covering control gear block
Fan-shaped reflector
for compact fluorescent lamps (2x TC-LEL 18/24W) | symmetric distribution, or asymmetric
(with shielding on building side) | incl. anti-glare ring for covering control gear block
Lamp shield
for high-pressure lamps (1x HSE 50/70W) | symmetric illumination | incl. anti-glare ring for
covering control gear block
1.86
1 Facade and path luminaires | Bollards and pillars
Planted section
for safe anchorage of bollard or pillar in foundation or concentrated ground | planted section
of steel, galvanized | with suitable aperture ring for fixing luminaire
Dimensions: da x h = 255 x 485mm
Optical enclosure
1.87
Facade and path luminaires | Bollards and pillars 1
1.88
2 Town and park luminaires | Overview
18m
15m
12m
9m
6m
3m
DL® 10 LED DL® 20 LED DL® 500 MIDI LED CITY-LIGHT PLUS CITY-LIGHT LANTERN LED MUSHROOM
Page 2.9 Page 2.17 Page 2.31 LED ELEGANCE LED Page 2.39 LUMINAIRE LED
Page 2.39 Page 2.39 Page 2.39
2.1
Town and park luminaires | Overview 2
18m
15m
12m
9m
6m
3m
2.2
2 Town and park luminaires | Overview
2.3
Town and park luminaires | Overview 2
DL® 10 LED DL® 20 LED Streetlight 10 Streetlight 10 DL® 500 MIDI CITY-LIGHT CITY-LIGHT LANTERN LED
micro LED mini LED LED PLUS LED ELEGANCE LED
Page 2.9 Page 2.17 Page 2.25 Page 2.25 Page 2.31 Page 2.39 Page 2.39 Page 2.39
LED modules
FANTASiE DL® 500 MIDI DL® 500 MAXI CITY-LIGHT CITY-LIGHT LANTERN LANTERN LANTERN
PLUS ELEGANCE CLASSIC DELUXE
Page 2.85 Page 2.91 Page 2.91 Page 2.125 Page 2.125 Page 2.137 Page 2.137 Page 2.137
2.4
2 Town and park luminaires | Product search
Insulation class II II II II II I | II
Recommended mounting height (m) 4.5…6 4…6 3.5…5 4…6 4…6 3…5
Recommended applications
— prestigious squares ¢ ¢
— pedestrian zones ¢ ¢ ¢
— urban areas ¢ ¢ ¢
— cycle paths ¢ ¢ ¢
— recreation areas and parcs ¢ ¢
— main thoroughfares ¢ ¢
— through-roads and collection roads ¢ ¢ ¢ ¢ ¢
— residential roads and areas ¢ ¢ ¢ ¢ ¢
Installation method
— post-top mounting ¢ ¢ ¢ ¢ ¢ ¢
— side-entry mounting ¢ ¢ ¢
— catenary mounting
Type of mast/bracket
— for standard mast ¢ ¢ ¢ ¢ ¢
— for design mast ¢ ¢
— mast included
— for wall bracket ¢ ¢ ¢ ¢
Lighting technology
— asym. extremely wide distribution ¢ ¢ ¢
— asym. wide distribution ¢ ¢ ¢ ¢ ¢
— sym. wide distribution ¢ ¢
— open distribution ¢
— with shielding on building side ¢
2.5
Town and park luminaires | Product search 2
LED modules
LANTERN LED MUSHROOM SMALL LARGE LED Module 520 LED module LED module LED module
LUMINAIRE LED BELL LED BELL LED BELL DL® 300 for Bergmeister
luminaires
I | II I | II II II II II II II
¢ ¢ ¢
¢ ¢ ¢ ¢
¢ ¢ ¢ ¢
¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢
¢ ¢ ¢ ¢
¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢
¢ ¢ ¢ ¢
¢ ¢ ¢ ¢
¢ ¢ ¢ ¢
¢ ¢ ¢ ¢
¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢
¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢
¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢
¢ ¢ ¢ ¢ ¢ ¢ ¢ ¢
2.6
2 Town and park luminaires | Product search
FANTASiE DL® 500 MIDI DL® 500 MAXI CITY-LIGHT LANTERN MUSHROOM
PLUS LUMINAIRE
Light source
— HIT-CE/HIT-CE S-od/ HIT-CE-od -/¢/- ¢/-/- ¢/-/-
— HIE-CE/HIE-CE-P ¢/- ¢/- -/¢ -/¢ -/¢
— TE-LEL/TC-TEL ¢/- ¢/- ¢/- ¢/- ¢/-
— HST/HSE ¢/¢ ¢/¢ -/¢ -/¢ -/¢
Insulation class II II II I | II I | II I | II
Recommended mounting height (m) 4…6 4…6 6…8 3…5 3…5 3…5
Recommended applications
— prestigious squares
— pedestrian zones ¢ ¢
— urban areas ¢ ¢ ¢ ¢ ¢ ¢
— cycle paths ¢
— recreation areas and parcs ¢ ¢ ¢ ¢
— main thoroughfares ¢ ¢
— through-roads and collection roads ¢ ¢ ¢
— residential roads and areas ¢ ¢ ¢ ¢ ¢ ¢
Installation method
— post-top mounting ¢ ¢ ¢ ¢ ¢ ¢
— side-entry mounting ¢ ¢
— catenary mounting ¢ ¢
Type of mast/bracket
— for standard mast ¢ ¢ ¢ ¢ ¢ ¢
— for design mast
— mast included
— for wall bracket ¢ ¢ ¢ ¢ ¢ ¢
Lighting technology
— asym. extremely wide distribution ¢ ¢ ¢
— asym. wide distribution ¢ ¢ ¢ ¢ ¢ ¢
— sym. wide distribution ¢ ¢ ¢ ¢ ¢
— open distribution ¢ ¢ ¢
— with shielding on building side ¢ ¢ ¢
2.7
Town and park luminaires | Product search 2
¢/-/- ¢/-/-
II II II II II
¢ ¢ ¢
¢ ¢ ¢
¢ ¢ ¢
¢ ¢
¢ ¢ ¢ ¢ ¢
¢ ¢
¢ ¢ ¢ ¢
¢ ¢ ¢ ¢ ¢
¢ ¢ ¢
¢
¢
¢ ¢ ¢
¢ ¢
¢ ¢ ¢ ¢ ¢
¢ ¢ ¢ ¢ ¢
¢ ¢ ¢
¢ ¢ ¢
2.8
2 Town and park luminaires | LED luminaires
DL® 10 LED
The DL® 10 LED combines state-of-the-art technology with The optical system of the DL® 10 LED consists of a precisely
a visionary design, and brings together all the strengths of matched combination of white high-power LEDs, optical
LED technology into one system. Characteristic for the DL® lens systems, special reflectors and a transparent luminaire
10 LED is an organic, flowing form ascending from the mast cover. Microprocessor-controlled operating electronics are
spigot to the luminaire head. LED lighting technology allows an integral part of the LED technology used. With its control
completely new housing forms and low construction heights functions the luminaire can be operated even more efficient-
– a strength that has been consistently taken advantage of. ly and therefore with greater optimization of energy and
costs. The control functions make use of the outstanding
With its white high-power LEDs, the DL® 10 LED illuminates property of LED light sources in reducing luminous flux with-
streets, town squares and traffic routes in accordance with out loss. With the Siteco® Service Box these settings can be
relevant standards. In addition to the version with neutral simply parameterized for each light point. With the RGB
white LEDs there is also a version with a supplementary version, for each white LED reduction level an RGB color or
RGB LED optical waveguide system. This enables additive RGB sequence can be assigned. Setting of the specific
color mixing for the luminaire head, serving as an accenting color is carried out via the Service Box directly at the lumi-
element for architecture and atmosphere. naire. Dynamic color sequences can be programmed with a
supplementary software, and can be transferred to the lumi-
naire via the Service Box or transmitted via DALI/DMX to the
corresponding address.
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
2.9
Town and park luminaires | LED luminaires 2
2.10
2 Town and park luminaires | LED luminaires
655 580
865
650
Aw max=0,332 m²
Mast luminaire for post-top mounting — housing of cast aluminum, Siteco® metal-
— with white LEDs and matching optical lic gray (DB 702S); cover of PMMA,
system of lenses, reflectors and prisms, transparent, partially frosted
asymmetric light with homogeneous, — type of protection: IP65
extremely wide distribution; additionally — insulation class: II
with RGB LED optical waveguide system — mast spigot: da = 76mm x 125mm
with diffuse distribution for color mast spigot inner diameter: di ≥ 68mm
accentuation (suitable for design mast or standard
— microprocessor-controlled LED operating steel mast)
FGNOP electronics; with control functionality for — recommended mounting height:
light management and monitoring; with LPH = 4.5…6m
customer-specific RGB color control
& &
Control function for light management and monitoring of LEDs with white light:
/XPLQRXVLQWHQVLW\FODVV • luminous flux of LED factory-set to 60%; this maximum value can be modified by the Service Box on-site if required
DFFRUGLQJWR • all versions: with temperature monitoring for protection of LEDs from thermal overload, additionally with
(1* • “Plus” version: with luminous flux constancy over complete service life | with integrated, programmable timer for luminous flux
reduction at two levels | alternatively: luminous flux reduction via 230V control voltage
• “Premium” version: (implemented with supplementary luminaire controller in mast): functional range as with “Plus” version, but for
individual monitoring and control of the luminaire from a central control point via LON PowerLine
RGB color control:
• customer-specific, static color setting of both activation value and reduction value: manually programmable via Siteco® Service Box
at luminaire (without supplementary signal line outside of the mast)
• customer-specific variable color control: almost complete random control (via 2 supplementary signal wires in the luminaire cable)
Mounting height 6m
/LFKWSXQNWKÓKHP1HLJXQJ Tilt 0° Designation Wt. (kg) Order no. Order no.
O[
OSRAM Siteco
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
Luminaire controller, LON PowerLine protocol, installation in mast 0.7 4039806896407 5EA3CUD101
Scene controller, DMX 512, 48 DMX channels, 4 program memories 0.3 4039806510167 5LZ9091048
Scene controller, DMX 512, 144 DMX channels, 4 program memories 0.3 4039806510174 5LZ9091144
P
Signal converter, DMX 512/DALI, addressable 0.3 4039806902344 5LZ9092DLIA
2.11
Town and park luminaires | LED luminaires 2
655 580
865
650
Aw max=0,332 m²
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
Luminaire controller, LON PowerLine protocol, installation in mast 0.7 4039806896407 5EA3CUD101
P
2.12
2 Town and park luminaires | LED luminaires
for parameterizing the operating electronics of all “Plus” version Siteco® LED road
luminaires | maximum energy efficiency via individual adaptation of lighting level, switching
time and reduction level | setting of static colors and dynamic color sequences with suitable
luminaires | Service Box includes software* | with plug-in coupling for connecting
Y-cable | plastic housing; plug-in coupling with protection cap | IP54 | insulation class II
— incl. Y-cable for looping the Service Box into luminaire supply cable | incl. “workshop” cable set for parameterizing the
unmounted luminaire in the workshop; safety plug on one end
* adoption of complete color sequences and software updates possible via PC | incl. mini USB interface for connection to PC
www.siteco.com > Service > Downloads > Software > PC tools > Architainment Suite
Siteco® Architainment Suite is compatible for example with the following operating systems:
Microsoft Windows XP and Vista.
Luminaire controller
Siteco® Light Control (SLC) luminaire controller for installation in mast | for upgrading “Plus”
version DL® 10 LED luminaires to “Premium” versions | controlling of luminaire controller via
LON PowerLine; with pre-assembled cables for connection at cable junction box and at
ECG of luminaire | plastic housing, white | IP54 | insulation class II
DMX control
Central control system for complex, networked color mixing controls of a maximum of 144
channels
Scene controller
Siteco® Light Control scene controller for RGB color mixing of 48 or 144 DMX channels | 4
zero-potential push button inputs for calling up of saved sequences (4 program memories) |
RS232 interface for loading of created sequences | plastic housing, white | for DIN rail
(6 depth module) | IP20 | insulation class I incl. software for creating sequences
Designation Sub-unit (TE) Wt. (kg) Order no. OSRAM Order no. Siteco
cable for data transmission from PC (zero modem cable) not included in scope of supply
Signal converter
Siteco® Light Control signal converter for conversion of DMX signals to SDI signals (Siteco®
Digital Interface) | 4 separate SDI lines each with max. of 10 luminaires | group control of
luminaires possible | DMX start address entered directly at device | plastic housing, gray | for
DIN rail (6x sub-unit) | IP20 | insulation class I
Designation Sub-unit (TE) Wt. (kg) Order no. OSRAM Order no. Siteco
2.14
2 Town and park luminaires | LED luminaires
Design mast
Design mast
with offset spigot for flush-fitting connection of mast to luminaire | conical round mast | steel,
galvanized and powder-coated in Siteco® metallic gray (DB 702S) | junction box for 2 cables
to 5x 16mm² or 3 cables to 5x 10mm² | two D01 fuse-bases with E14 screw caps | plastic
housing | IP44 | insulation class II
Designation h (m) LPH (m) h1 (m) d (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
Cable junction box* Terminals L1, L2, L3, N, PE(N) 4039806199973 5NY70012XK
* see the accessories section for further versions (connection options, fusing, protection rating)
95
865
125
76
lph
h
400
600
350
h1
2.15
Town and park luminaires | LED luminaires 2
2.16
2 Town and park luminaires | LED luminaires
DL® 20 LED
The DL® 20 LED impressively demonstrates how innovative The town and park luminaire fulfills DIN EN 13201 for S and
technology can be combined with outstanding design to ME lighting classes so that standard-compliant road and
cast a bridge into the future. The DL® 20 LED is the consis- plaza lighting can be achieved with high energy efficiency
tent, state-of-the-art further development of the classic and a high design appeal. The LED luminaire can be individ-
lantern-design luminaire, but with the latest energy-efficient ually set according to needs via the microprocessor-con-
LED technology. trolled LED operating electronics for the performance
packages “Plus” (with Service Box) and “Premium” (with
Siteco® Light Control).
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
2.17
Town and park luminaires | LED luminaires 2
Features 1-pole for 230V control voltage for power reduction + 2-pole
— patented multiple light deflection with high-power LEDs for Siteco® Digital Interface (SDI)) | SDI for parameterizing of
— design with light colors possible: variants with warm luminaire with Siteco® Service Box (with integration of lumi-
white or neutral white light color naire into digital control system on request) | alternatively:
— combination of micro LED reflector of aluminized plastic, luminous flux reduction via 230V control voltage; control
luminaire reflector in MIRO® quality and high-quality white signal: USt = 230V → 100% luminous flux; USt = 0V →
glass approx. 50% luminous flux
— bi-component construction of ring with LED and arm
optimizes stock-keeping and shortens time needed for “Premium” performance package: (implemented with
installation supplementary luminaire controller in mast) | with 2-pole
— optimized thermal management: ballast in mast mounting connection terminal with free wire ends (control and moni-
element, luminaire housing acts as heat sink for the LED toring of luminaire from a central control center without
technology additional control wires; data transmission according to
— for standard mast, steel with spigot diameter 76mm and standardized LON protocol)
for the SM300 series design mast
— long system service life (up to 50,000h) Housing
2-part luminaire housing consisting of ring with LEDs and
Lighting technology arm | ring and arm of cast aluminum | flat optical cover of
Patented multiple light deflection via combination of micro toughened safety glass | high-quality, weather-resistant
LED reflector of aluminized plastic and luminaire reflector in coating in Siteco® metallic gray (DB 702S) | insulation class:
MIRO® quality and flat, reflection-reduced white glass cover, II | protection rating: IP66
with white high-power LEDs:
— version for uniform, symmetric wide light distribution Applications
— version for uniform, asymmetric wide light distribution — town squares and city centers
— version with cycle path optics for uniform, asymmetric — side streets, thoroughfares in communities
extremely wide light distribution — residential areas
— parks
Electrics — luminaire spacing 25…30m
Luminaire with electronic ballast and pre-assembled cable
for connection of luminaire in mast terminal box
2.18
2 Town and park luminaires | LED luminaires
0%
ø690
690
Aw=0,08 m²
10
— for “Premium” version: please order luminaire controller additionally to “Plus” version luminaire
— please order further SLC light management components separately if required
— luminaire including assembled connection cable; see accessories for suitable design masts
P
2.19
Town and park luminaires | LED luminaires 2
0%
ø690
690
Aw=0,08 m²
10
— for “Premium” version: please order luminaire controller additionally to “Plus” version luminaire
— please order further SLC light management components separately if required
— luminaire including assembled connection cable; see accessories for suitable design masts
P
2.20
2 Town and park luminaires | LED luminaires
0%
ø690
690
Aw=0,08 m²
10
— for “Premium” version: please order luminaire controller additionally to “Plus” version luminaire
— please order further SLC light management components separately if required
— luminaire including assembled connection cable; see accessories for suitable design masts
2.21
Town and park luminaires | LED luminaires 2
for parameterizing the operating electronics of all “Plus” version Siteco® LED road luminaires
| maximum energy efficiency via individual adaptation of lighting level, switching time and re-
duction level | setting of static colors and dynamic color sequences with suitable luminaires |
Service Box includes software* | with plug-in coupling for connecting Y-cable | plastic
housing; plug-in coupling with protection cap | IP54 | insulation class II
— incl. Y-cable for looping the Service Box into luminaire supply cable | incl. “workshop” cable set for parameterizing the
unmounted luminaire in the workshop; safety plug on one end
* software updates possible via PC | incl. mini USB interface for connection to PC
Luminaire controller
Siteco® Light Control (SLC) luminaire controller for installation in mast | for upgrading “Plus”
version Siteco® outdoor LED luminaires to “Premium” versions | controlling of luminaire con-
troller via LON PowerLine; with pre-assembled cables for connection at cable junction box
and at ECG of luminaire | plastic housing, white | IP54 | insulation class II
2.22
2 Town and park luminaires | LED luminaires
Design mast
Design mast
with offset spigot for flush-fitting connection of mast to luminaire | conical round mast | steel,
galvanized and powder-coated in Siteco® metallic gray (DB 702S) | junction box for 2 cables
to 5x 16mm² or 3 cables to 5x 10mm² | two D01 fuse-bases with E14 screw caps | plastic
housing | IP44 | insulation class II
Designation h (m) LPH (m) h1 (m) d (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
Cable junction box* Terminals L1, L2, L3, N, PE(N) 4039806199973 5NY70012XK
* see the accessories section for further versions (connection options, fusing, protection rating)
95
125
690
76
h
400
600
350
h1
2.23
Town and park luminaires | LED luminaires 2
2.24
2 Town and park luminaires | LED luminaires
Streetlight 10 LED
The Streetlight 10 LED is the standard for an LED outdoor The microprocessor-controlled LED operating electronics
luminaire designed completely according to the factors of make available an especially high level of efficiency potential.
efficiency and lighting effect. A purist, functional design Luminous flux can be individually set according to needs
comes together with high-power LEDs and outstanding with the performance packages “Plus” (with Siteco® Service
photometrics. As such, the Streetlight 10 LED eminently Box) and “Premium” (with Street Light Control).
complies with the requirements of DIN EN 13201 for all S
and M lighting classes. The Streetlight 10 LED is available in The mechanical concept of the luminaire is also future-fit.
construction sizes mini and midi with either one or two LED Both the optical module and the gear tray can be simply and
modules in each case. In addition to the highly precise road rapidly replaced. This means upgrading to future, higher-
optics used in both construction sizes, there is also an performance LED modules is easily implemented. This
optical module for the lighting of cycle paths (recommended: solution enables a sustainable and future-oriented use of the
mini) and a solution for pedestrian crossings (recommended: high-quality luminaire housing.
midi).
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
2.25
Town and park luminaires | LED luminaires 2
2.26
2 Town and park luminaires | LED luminaires
0% 0°
481 177
46
231
Aw=0,04 m²
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast fl ange according to spigot diameter separately
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0° Mandatory accessories (for details see page 2.30)
O[
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Mast flange, spigot size: 42mm 0.4 4050737115726 5XA59000XM4
Mast flange, spigot size: 60mm 0.5 4050737115702 5XA59000XM2
P
Mast flange, spigot size: 76mm 0.6 4050737101484 5XA59000XM1
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.9 4050737028828 5EA6Y00L03
2.27 Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
Town and park luminaires | LED luminaires 2
0% 0°
619 170
45
137
Aw=0,07 m²
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast fl ange according to spigot diameter separately
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0° Mandatory accessories (for details see page 2.30)
O[
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Mast flange, spigot size: 42mm 0.4 4050737115726 5XA59000XM4
Mast flange, spigot size: 60mm 0.5 4050737115702 5XA59000XM2
P
Mast flange, spigot size: 76mm 0.6 4050737101484 5XA59000XM1
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.9 4050737028828 5EA6Y00L03
Mast cable set, L = 6m, for “Plus” version 0.9 4050737056098 5EA6Y00L08
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
2 Town and park luminaires | LED luminaires
0% 0°
619 170
45
137
Aw=0,1 m²
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast fl ange according to spigot diameter separately
P
2.29
Town and park luminaires | LED luminaires 2
Mast flange
for mounting the Streetlight 10 LED as post-top or side-entry luminaire by rotating the mast
flange | luminaire inclination set via mast flange (0°, 5°, 10°, 15°) | various mast flanges for
differing mast spigot diameters | mast flange of diecast aluminum, light gray (RAL 7035)
— mast fl ange not included in luminaire scope of supply; please order mast fl ange separately according to mast spigot
diameter
da
Mounting information for post-top mounting
l
Mast spigot: da x l = 76 x 100mm (luminaire mounting possible with mast flange type 76)
da x l = 60 x 100mm (luminaire mounting possible with mast flange type 60)
Mast spigot: da x l = 60 x 100mm (luminaire mounting possible with mast flange type 60)
da x l = 42 x 100mm (luminaire mounting possible with mast flange type 42)
2.30
2 Town and park luminaires | LED luminaires
The DL® 500 MIDI LED enables existing installations to be the microprocessor-controlled LED operating electronics
expanded with a high level of energy efficiency so that the with the “Plus” (with Service Box) and “Premium” (with
familiar visual and harmonious appearance of the installation Street Light Control) performance packages.
is kept. Of course the DL® 500 MIDI design classic, thanks
to state-of-the-art LED technology and precisely matched With Siteco® gear tray technology, the LED module of the
optical systems, can also be planned and installed for new new DL® 500 LED luminaires is replaceable. This means
installations according to DIN EN 13201. The LED module upgrading to future, higher-performance LED modules is
can also be individually set according to requirements via easily implemented.
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
2.31
Town and park luminaires | LED luminaires 2
2.32
2 Town and park luminaires | LED luminaires
0%
800
188
350
ø100
ø500
Aw=0,20 m²
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
0RXQWLQJKHLJKWP7LOW
— please order mast reducer separately if required
O[
Accessories (for details see page 2.36 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Mast cable set, L = 6m, for “Plus” version 0.9 4050737056098 5EA6Y00L08
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.33
Town and park luminaires | LED luminaires 2
0%
1150
188
700
ø100
ø500
Aw=0,20 m²
Mast luminaire with supporting structure for (DB 702S); supporting structure elements
post-top mounting of V4A; cover of toughened safety glass
— with white LEDs with lens, asymmetric — type of protection: IP65
wide distribution; with flat, structured and — insulation class: II
reflection-reduced cover — mast spigot: da = 76 x 100mm
— microprocessor-controlled LED operating — recommended mounting height:
electronics; depending on version with LPH = 4…6m
differing control function for light — mast connection for twin arrangement
management and monitoring on request
FGNOP — housing and mast connection of diecast
aluminum, Siteco® metallic gray
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
0RXQWLQJKHLJKWP7LOW
O[
P
2.34
2 Town and park luminaires | LED luminaires
0%
620
188
ø80
ø500
Aw=0,20 m²
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
0RXQWLQJKHLJKWP7LOW
O[
P
2.35
Town and park luminaires | LED luminaires 2
for parameterizing the operating electronics of all “Plus” version Siteco® LED road luminaires
| maximum energy efficiency via individual adaptation of lighting level, switching time and re-
duction level | setting of static colors and dynamic color sequences with suitable luminaires |
Service Box includes software* | with plug-in coupling for connecting Y-cable | plastic
housing; plug-in coupling with protection cap | IP54 | insulation class II
— incl. Y-cable for looping the Service Box into luminaire supply cable | incl. “workshop” cable set for parameterizing the
unmounted luminaire in the workshop; safety plug on one end
* adoption of complete color sequences and software updates possible via PC | incl. mini USB interface for connection to PC
for wiring of junction box in mast to luminaire, with “Plus” version | with 5-pole plug-in
coupling for integration of Siteco® Service Box, for manual parameterization of luminaire
(e.g. luminous flux, timer etc.)
2.36
2 Town and park luminaires | LED luminaires
for mounting DL® 500 …- M | … -T | … -A luminaire to mast with spigot size da = 60mm
(post-top) or spigot size da = 42mm (side-entry) | reducer of diecast aluminum
Optical enclosure
For detailed information about intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires, see Chapter 6 are specified in Chapter 7
2.37
Town and park luminaires | LED luminaires 2
2.38
2 Town and park luminaires | LED luminaires
The LED luminaires of the CITY-LIGHT, LANTERN and The LED Module 520 is equipped with microprocessor-con-
MUSHROOM LUMINAIRE families interpret the form of the trolled LED operating electronics. This makes available a se-
classic lanterns into a new and contemporary type. The re- ries of functions. These have been combined into three per-
sult is an installation-friendly, modularly designed luminaire formance packages: “Basic”, “Plus” and “Premium”. All make
with an elegant, transparent impression and state-of-the-art, use of the outstanding property of LED light sources in re-
efficient lighting technology. ducing luminous flux without loss. These values are either
factory-set (“Basic” version), can be individually set with the
With the LED versions of these luminaire families the classic Siteco® Service Box (“Plus” version) or centrally set via
electrical insert has been replaced by the LED Module 520 Street Light Control (“Premium” version). The “Plus” and
especially developed by Siteco for this purpose. The modu- “Premium” versions offer the widest spectrum of efficient
lar construction ensures that later, more modern and higher- control of LED luminaires according to requirements.
performance LED generations can be retrofitted and used
with ease. The glare-free, directed light distribution is All optical components as well as the electrical inserts and
achieved via a precisely matched combination of high-per- the LED Module 520 for the town and park luminaires
formance LEDs, optical lens systems, highly specular reflec- MUSHROOM LUMINAIRE, LANTERN, LANTERN CLASSIC,
tors and transparent luminaire enclosures. The LED Module LANTERN DELUXE, CITY-LIGHT PLUS and CITY-LIGHT
520 has symmetric or asymmetric light distribution and is ELEGANCE can be interchanged thanks to outstanding
available either with warm white or neutral white color tem- availability of replacement parts and the rapid, maintenance-
perature. friendly exchange of components, allowing greater flexibility
for design.
New:
LED town and parc luminaires with new LED Module 540
Ready for order: Q3/2014
Detailed information:
www.siteco.com/LEDModule540
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
2.39
Town and park luminaires | LED luminaires 2
Housing Applications
Self-centering mast mounting element of diecast aluminum; — town centers
glass-fiber-reinforced polyester canopy element; housing — parks
and canopy with weather-resistant coating in Siteco® metal- — residential streets and collection roads
lic gray (DB 702S); canopy underside in white, functions as — residential areas
reflector; supporting elements of aluminum | cover of im- — luminaire spacing 25…30m
pact-resistant, UV-stabilized PMMA, transparent | insulation
class: II | protection rating: IP54
Electrics
Cover opened without tools | LED module and all electric
components as removable unit
2.40
2 Town and park luminaires | LED luminaires
ø750
590
Aw=0,15 m²
ø185
ø280
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
OSRAM Siteco
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.41
Town and park luminaires | LED luminaires 2
ø750
590
Aw=0,15 m²
ø185
ø280
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
OSRAM Siteco
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.42
2 Town and park luminaires | LED luminaires
ø750
675
Aw=0,15 m²
ø185
ø280
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0° Designation Wt. (kg) Order no. Order no.
O[
OSRAM Siteco
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.43
Town and park luminaires | LED luminaires 2
ø750
675
Aw=0,15 m²
ø185
ø280
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0° Designation Wt. (kg) Order no. Order no.
O[
OSRAM Siteco
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.44
2 Town and park luminaires | LED luminaires
ø750
583
320
Aw=0,16 m²
ø185
Luminaire for post-top mounting or canopy element; all parts in Siteco® me-
mounting to wall arm tallic gray (DB 702S), canopy underside
— with white LEDs, symmetric distribution; in white; cover of PMMA
with light dispersing element for lumi- — type of protection: IP54
nance reduction; with transparent cover — insulation class: II
— microprocessor-controlled LED operating — mast spigot: da = 76 x 70mm
electronics; depending on version with (with reducer: da = 60mm)
differing control function for light — recommended mounting height:
management and monitoring LPH = 3…5m
FGNOP — mast mounting element of diecast alu-
minum; glass-fiber-reinforced polyester
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0° Designation Wt. (kg) Order no. Order no.
O[
OSRAM Siteco
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.45
Town and park luminaires | LED luminaires 2
ø750
583
320
Aw=0,16 m²
ø185
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0° Designation Wt. (kg) Order no. Order no.
O[
OSRAM Siteco
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.46
2 Town and park luminaires | LED luminaires
ø750
596
Aw=0,16 m²
ø185
ø270
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0° Designation Wt. (kg) Order no. Order no.
O[
OSRAM Siteco
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.47
Town and park luminaires | LED luminaires 2
ø750
596
Aw=0,16 m²
ø185
ø270
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.48
2 Town and park luminaires | LED luminaires
ø750
596
Aw=0,16 m²
ø185
ø270
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0° Designation Wt. (kg) Order no. Order no.
O[
OSRAM Siteco
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.49
Town and park luminaires | LED luminaires 2
ø750
596
Aw=0,16 m²
ø185
ø270
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.50
2 Town and park luminaires | LED luminaires
ø650
586
Aw=0,14 m²
ø185
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0° Designation Wt. (kg) Order no. Order no.
O[
OSRAM Siteco
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.51
Town and park luminaires | LED luminaires 2
ø650
586
Aw=0,14 m²
ø185
10
— please order the “mast cable set” separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0° Designation Wt. (kg) Order no. Order no.
O[
OSRAM Siteco
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
2.52
2 Town and park luminaires | LED luminaires
The LED Module 520 is the simple solution for the energy- set with the Siteco® Service Box (“Plus” version) or centrally
efficient and sustainable refurbishment of technically obso- set via Street Light Control (“Premium” version). The “Plus”
lete road luminaires with modern, cost-optimized and CO2- and “Premium” versions offer the widest spectrum of effi-
optimized LED lighting technology. The LED Module 520 cient control and monitoring of LED luminaires according to
replaces the gear tray with conventional lighting technology requirements.
for the luminaires CITY-LIGHT PLUS, CITY-LIGHT ELEGANCE,
LANTERN, LANTERN CLASSIC, LANTERN DELUXE, “Basic” performance package:
MUSHROOM LUMINAIRE, CITY-LIGHT BOLLARD 120 and temperature monitoring for protection of LEDs from thermal
120 E as well as CITY-LIGHT PILLAR 260, 260 E and 260 D. overload | luminous flux reduction via 230V control voltage
The modular construction ensures that later, more modern
and higher-performance LED generations can be retrofitted “Plus” performance package:
and used with ease. For taking complete advantage of the luminous flux constancy over complete service life | with in-
performance potential of the LED Module 520, we recom- tegrated, programmable timer for luminous flux reduction at
mend combining it with a transparent luminaire cover when two levels | settable luminous flux for max. operation and for
refurbishing obsolete systems. both reduction levels | all parameters set with the Siteco®
Service Box | can be additionally integrated via SDI into ex-
The LED Module 520 based on the Siteco® gear tray tech- isting digital control systems and controllable from a central
nology has symmetric or asymmetric light distribution and is control point | temperature monitoring for protection of LEDs
available either with warm white or neutral white color tem- from thermal overload | alternatively: luminous flux reduction
perature. It consists of a precisely matched combination of via 230V control voltage
high-performance LEDs, optical lens systems, highly specu-
lar reflectors and microprocessor-controlled LED operating “Premium” performance package:
electronics. This in turn makes available a series of addition- Street Light Control: for individual monitoring and control of
al functions. These functions have been combined into three the luminaire from a central control point from any distance
different performance packages: “Basic”, “Plus” and “Premi- via LON PowerLine without supplementary control wire
um”. All make use of the outstanding property of LED light (instead of SDI) | further functional spectrum as with “Plus”
sources in reducing luminous flux without loss. These values variant
are either factory-set (“Basic” version), can be individually
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
2.53
Town and park luminaires | LED luminaires 2
2.54
2 Town and park luminaires | LED luminaires
158
150
172
512
LED Module 520
symmetric distribution | insulation class II
LED Module 520 gear tray for refurbishment differing control function for light
of the CITY-LIGHT, LANTERN and management and monitoring
MUSHROOM LUMINAIRE families, — outer housing of sheet steel, metallic
CITY-LIGHT 120 bollards and CITY-LIGHT gray (RAL 9006); heat sink of extruded
260 pillars to modern, economic LED aluminum; reflector of high-performance
technology polymer, highly specular vaporized
— with white LEDs, symmetric distribution; — protection rating: as luminaire
with light dispersing element for lumi- — insulation class: II
nance reduction; for luminaires with — LED modules operate most efficiently
transparent cover with luminaires with transparent cover | a
— microprocessor-controlled LED operating new mast mounting element is required
electronics; depending on version with for luminaires with mast mounting
element with plastic cap
Control function for light management and monitoring:
• all versions with temperature monitoring for protection of LEDs from thermal overload
• LED module, “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
• LED module, “Plus” version: with luminous flux constancy over complete service life | with integrated, programmable timer for
luminous flux reduction at two levels | settable luminous flux for max. operation and for both reduction levels | all parameters can be
set with the Siteco® Service Box | on request: can be integrated via SDI into existing digital control systems and controlled from a
central control point | alternatively: luminous flux reduction via 230V control voltage
• LED module, “Premium” version: functional range as with “Plus” version, but for individual monitoring and control of the luminaire
from a central control point from any distance via LON PowerLine without supplementary control wire (instead of SDI)
• LED module can be operated with factory pre-setting. The pre-setting with the “Plus” and “Premium” versions can be modified with
the mounted or dismantled luminaire
10
— please order transparent luminaire cover and mast mounting element separately if required
— please order the “mast cable set”, “bollard cable set” or “pillar cable set” separately if required for confi guration of the
LED module in the “Plus” version with the mounted luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
2.55
Town and park luminaires | LED luminaires 2
2.56
2 Town and park luminaires | LED luminaires
158
150
172
512
LED Module 520
asymmetric distribution | insulation class II
LED Module 520 gear tray for refurbishment differing control function for light
of the CITY-LIGHT, LANTERN and management and monitoring
MUSHROOM LUMINAIRE families, — outer housing of sheet steel, metallic
CITY-LIGHT 120 bollards and CITY-LIGHT gray (RAL 9006); heat sink of extruded
260 pillars to modern, economic LED aluminum; reflector of high-performance
technology polymer, highly specular vaporized
— with white LEDs, asymmetric distribution, — protection rating: as luminaire
without light emission into the rear area; — insulation class: II
with light dispersing element for lumi- — LED modules operate most efficiently
nance reduction; for luminaires with with luminaires with transparent cover | a
transparent cover new mast mounting element is required
— microprocessor-controlled LED operating for luminaires with mast mounting
electronics; depending on version with element with plastic cap
Control function for light management and monitoring:
• all versions with temperature monitoring for protection of LEDs from thermal overload
• LED module, “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
• LED module, “Plus” version: with luminous flux constancy over complete service life | with integrated, programmable timer for
luminous flux reduction at two levels | settable luminous flux for max. operation and for both reduction levels | all parameters can be
set with the Siteco® Service Box | on request: can be integrated via SDI into existing digital control systems and controlled from a
central control point | alternatively: luminous flux reduction via 230V control voltage
• LED module, “Premium” version: functional range as with “Plus” version, but for individual monitoring and control of the luminaire
from a central control point from any distance via LON PowerLine without supplementary control wire (instead of SDI)
• LED module can be operated with factory pre-setting. The pre-setting with the “Plus” and “Premium” versions can be modified with
the mounted or dismantled luminaire
10
— please order transparent luminaire cover and mast mounting element separately if required
— please order the “mast cable set”, “bollard cable set” or “pillar cable set” separately if required for confi guration of the
LED module in the “Plus” version with the mounted luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast reducer separately if required
2.57
Town and park luminaires | LED luminaires 2
2.58
2 Town and park luminaires | LED luminaires
for parameterizing the operating electronics of all “Plus” version Siteco® LED road luminaires
| maximum energy efficiency via individual adaptation of lighting level, switching time and re-
duction level | setting of static colors and dynamic color sequences with suitable luminaires |
Service Box includes software* | with plug-in coupling for connecting Y-cable | plastic
housing; plug-in coupling with protection cap | IP54 | insulation class II
— incl. Y-cable for looping the Service Box into luminaire supply cable | incl. “workshop” cable set for parameterizing the
unmounted luminaire in the workshop; safety plug on one end
* adoption of complete color sequences and software updates possible via PC | incl. mini USB interface for connection to PC
for wiring of junction box in mast to LED Module 520, with “Plus” version in the mounted
luminaire | with 5-pole plug-in coupling for integration of Siteco® Service Box, for manual
parameterization of luminaire (e.g. luminous flux, timer etc.)
2.59
Town and park luminaires | LED luminaires 2
Optical enclosure
transparent | PMMA
(LED modules offer the best efficiency with luminaires with transparent covers)
MUSHROOM LUMINAIRE
LANTERN
LANTERN CLASSIC
LANTERN DELUXE
Cover for
CITY-LIGHT PLUS | … ELEGANCE 1.4 4039806059666 5NA54900XG
CITY-LIGHT 120 | … 120 E | …260 | … 260 E | … 260 D 1.4 4039806059666 5NA54900XG
LANTERN | …CLASSIC | … DELUXE 1.4 4039806180513 5NC54700XG
MUSHROOM LUMINAIRE 1.4 4039806179296 5LA53220XG
2.60
2 Town and park luminaires | LED luminaires
of diecast aluminum, Siteco® metallic gray (DB 702S)* (a new mast mounting element is
required for luminaires with mast mounting element with plastic cap)
for mounting the luminaire* to masts with spigot size da = 60mm | reducer of diecast aluminum
* for all versions of CITY-LIGHT, LANTERN and MUSHROOM LUMINAIRE from year of construction 2002 (luminaire fixing with 1
fixing screw)
2.61
Town and park luminaires | LED luminaires 2
2.62
2 Town and park luminaires | LED luminaires
A classic, decorative design, simultaneously better light, and installations with their low effort and simple handling. And
with outstanding optics and significantly lower costs. The without compromises, because concealed in the BELL LED
LED variant of the BELL is the future-fit solution for is the only slightly modified module of the highly efficient
decorative lighting tasks in outdoor areas. LED road luminaire, the Streetlight 10 from Siteco.
Two construction sizes, several control variants and various Thanks to Siteco® gear tray technology, the LED module of
covers make it the flexible all-rounder for all applications. the BELL LED is replaceable. This means upgrading to
future, higher-performance LED modules is easily imple-
The BELL LED and the special BELL LED module are ideally mented.
suited for the modernizing or expanding of existing
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
2.63
Town and park luminaires | LED luminaires 2
2.64
2 Town and park luminaires | LED luminaires
410
575
Aw=0,10 m²
ø430
SMALL BELL LED
;$$$
[/('.&5,ƁI1OP
with transparent cover
Luminaire can be operated with factory pre-setting. Pre-setting with the “Plus” version can be modified with the dismantled luminaire,
and with the “Premium” version it can be modified with the mounted or dismantled luminaire
10
— please order SLC light management components for the “Premium” version separately if required
— please order shielding on building side separately if required
— please order curved mast extension or wall bracket separately
— luminaire color: Siteco ® metallic gray (DB 702S) as standard
— further RAL colors and DB color tones on request
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.65
Town and park luminaires | LED luminaires 2
2.66
2 Town and park luminaires | LED luminaires
410
575
Aw=0,10 m²
ø430
Luminaire can be operated with factory pre-setting. Pre-setting with the “Plus” version can be modified with the dismantled luminaire,
and with the “Premium” version it can be modified with the mounted or dismantled luminaire
10
— please order SLC light management components for the “Premium” version separately if required
— please order shielding on building side separately if required
— please order curved mast extension or wall bracket separately
— luminaire color: Siteco ® metallic gray (DB 702S) as standard
— further RAL colors and DB color tones on request
Mounting height 4m
0RXQWLQJKHLJKWP7LOW
Tilt 0°
O[
P
2.67
Town and park luminaires | LED luminaires 2
2.68
2 Town and park luminaires | LED luminaires
500
695
Aw=0,15 m²
ø530
LARGE BELL LED
;$$$
[/('.&5,ƁI1OP
with transparent cover
Luminaire can be operated with factory pre-setting. Pre-setting with the “Plus” version can be modified with the dismantled luminaire,
and with the “Premium” version it can be modified with the mounted or dismantled luminaire
10
— please order SLC light management components for the “Premium” version separately if required
— please order shielding on building side separately if required
— please order curved mast extension or wall bracket separately
— luminaire color: Siteco ® metallic gray (DB 702S) as standard
— further RAL colors and DB color tones on request
Mounting height 5m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.69
Town and park luminaires | LED luminaires 2
2.70
2 Town and park luminaires | LED luminaires
500
695
Aw=0,15 m²
ø530
Luminaire can be operated with factory pre-setting. Pre-setting with the “Plus” version can be modified with the dismantled luminaire,
and with the “Premium” version it can be modified with the mounted or dismantled luminaire
10
— please order SLC light management components for the “Premium” version separately if required
— please order shielding on building side separately if required
— please order curved mast extension or wall bracket separately
— luminaire color: Siteco ® metallic gray (DB 702S) as standard
— further RAL colors and DB color tones on request
Mounting height 5m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.71
Town and park luminaires | LED luminaires 2
2.72
2 Town and park luminaires | LED luminaires
Shielding for building side LARGE BELL LED 0.1 4050737087955 5NA15600XB1
Shielding for building side SMALL BELL LED 0.1 4050737087979 5NA15700XB1
Mast mounting element with clamp | twin fixing to mast, fixing with grub screws | steel,
galvanized and coated, Siteco® metallic gray (DB 702S)* | suitable for cylindrical masts
Designation Mast spigot: da (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
* luminaire color Siteco® metallic gray (DB 702S) as standard | for luminaire color black (RAL 9005), please replace number “8” at the
end of the order number with “1”; for light gray (RAL 7035), use number “5”. Corresponding OSRAM order number on request.
a1 a2
200
c
da da
a1 a2 c
SMALL BELL: 5NY157… 445 445 829
LARGE BELL 5NY156… 595 595 1040
2.73
Town and park luminaires | LED luminaires 2
Mast mounting element with ball element | fixing to mast via internal expanding clamp
without visible screws | steel, galvanized and coated, Siteco ® metallic gray (DB 702S)* |
suitable for conical and cylindrical masts
Designation Mast spigot: da (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
* luminaire color Siteco® metallic gray (DB 702S) as standard | for luminaire color black (RAL 9005), please replace number “8” at the
end of the order number with “1”; for light gray (RAL 7035), use number “5”. Corresponding OSRAM order number on request.
a1 a2
c
b
a1 a2 b c
SMALL BELL: 5NY157… 360 460 436 829
LARGE BELL 5NY156… 500 610 500 1040
2.74
2 Town and park luminaires | LED luminaires
Mast mounting element with ball element | fixing to mast via grub screws below ball;
guidance via tube supports entering into mast | steel, galvanized and coated, Siteco®
metallic gray (DB 702S)* | suitable for conical and cylindrical masts
Designation Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
* luminaire color Siteco® metallic gray (DB 702S) as standard | for luminaire color black (RAL 9005), please replace number “8” at the
end of the order number with “1”; for light gray (RAL 7035), use number “5”. Corresponding OSRAM order number on request.
360 500
725
850
450
4 65
115
3xM10. 120°
200
3xM10. 120°
da
da
Wall arm
Designation No. of brackets Wt. (kg) Order no. OSRAM Order no. Siteco
* luminaire color Siteco® metallic gray (DB 702S) as standard | for luminaire color black (RAL 9005), please replace number “8” at the
end of the order number with “1”; for light gray (RAL 7035), use number “5”. Corresponding OSRAM order number on request.
610 820
829
ø9
430
1040
93
ø42
500
120
ø11
ø203
ø60
ø272
93
120
For detailed information about intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires, see Chapter 6 are specified in Chapter 7
2.75
Town and park luminaires | LED luminaires 2
for parameterizing the operating electronics of all “Plus” version Siteco® LED road luminaires
| maximum energy efficiency via individual adaptation of lighting level, switching time and re-
duction level | setting of static colors and dynamic color sequences with suitable luminaires |
Service Box includes software* | with plug-in coupling for connecting Y-cable | plastic
housing; plug-in coupling with protection cap | IP54 | insulation class II
— incl. Y-cable for looping the Service Box into luminaire supply cable | incl. “workshop” cable set for parameterizing the
unmounted luminaire in the workshop; safety plug on one end
* adoption of complete color sequences and software updates possible via PC | incl. mini USB interface for connection to PC
2.76
2 Town and park luminaires | LED luminaires
LED gear tray for LARGE and SMALL BELL LED for replacement or upgrading with contin-
ued use of cover | with white LEDs with reflectors for homogeneous, asymmetric wide light
distribution | microprocessor-controlled LED operating electronics; depending on version
with differing control function for light management and monitoring
Optical cover
Designation Inner diameter di Wt. (kg) Order no. OSRAM Order no. Siteco
For detailed information about intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires, see Chapter 6 are specified in Chapter 7
2.77
Town and park luminaires | LED luminaires 2
236
ø358
LED module incl. optical enclosure for up- — microprocessor-controlled LED operating
grading existing luminaires with conventional electronics; depending on version with
lamps differing control function for light
— with white LEDs with reflectors, asym- management and monitoring
metric light with homogeneous, wide — cover of PMMA
distribution; additional reduction of light — protection rating: as luminaire
emission into the rear area due to shield- — insulation class: II
ing on building side; with transparent or — recommended mounting height:
stippled cover LPH = 3.5…5m
Control function for light management and monitoring:
• all versions: with temperature monitoring for protection of LEDs from thermal overload, additionally with
• “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
• “Plus” version: with luminous flux constancy over complete service life | with integrated, programmable timer for luminous flux
reduction at two levels | alternatively: luminous flux reduction via 230V control voltage
Luminaire can be operated with factory pre-setting. The pre-setting with the “Plus” version can be modified with the dismantled
luminaire.
10
Stippled diffuser
LED 3000 > 80 1225 18 18 9 2.3 Basic 4050737072456 5XA1571E1A2
LED 3000 > 80 1055 15 18 9 2.3 Plus 4050737072470 5XA1571E1B2
LED 4700 > 70 1600 18 18 9 2.3 Basic 4050737072371 5XA1571A1A2
LED 4700 > 70 1400 15 18 9 2.3 Plus 4050737072401 5XA1571A1B2
2.78
2 Town and park luminaires | LED luminaires
272
ø440
LED module incl. optical enclosure for up- — microprocessor-controlled LED operating
grading existing luminaires with conventional electronics; depending on version with
lamps differing control function for light
— with white LEDs with reflectors, asymme- management and monitoring
tric light with homogeneous, wide — cover of PMMA
distribution; additional reduction of light — protection rating: as luminaire
emission into the rear area due to shiel- — insulation class: II
ding on building side; with transparent or — recommended mounting height:
stippled cover LPH = 4…6m
Control function for light management and monitoring:
• all versions: with temperature monitoring for protection of LEDs from thermal overload, additionally with
• “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
• “Plus” version: with luminous flux constancy over complete service life | with integrated, programmable timer for luminous flux
reduction at two levels | alternatively: luminous flux reduction via 230V control voltage
Luminaire can be operated with factory pre-setting. The pre-setting with the “Plus” version can be modified with the dismantled
luminaire.
10
Stippled diffuser
LED 3000 > 80 2440 37 37 18 4.2 Basic 4050737072302 5XA1561E1A2
LED 3000 > 80 2150 32 37 18 4.1 Plus 4050737072319 5XA1561E1B2
LED 4700 > 70 3215 37 37 18 3.1 Basic 4050737072128 5XA1561A1A2
LED 4700 > 70 2870 32 37 18 3.1 Plus 4050737072234 5XA1561A1B2
2.79
Town and park luminaires | LED luminaires 2
2.80
2 Town and park luminaires | LED luminaires
The DL® 300 LED module is the simple solution for the ener- ple handling. And without compromises, because concealed
gy-efficient and sustainable refurbishment of technically ob- in the LED module is the only slightly modified module of the
solete luminaires with modern, cost-optimized and CO2-opti- efficient Streetlight 10 road luminaire from Siteco. Due to
mized LED lighting technology. It replaces gear trays with Siteco® gear tray technology, upgrading to future, higher-
conventional lighting technology and the covers of lumi- performance LED modules is easily implemented.
naires DL® 300, DL® 302, DL® 304 and DL® 308.
The LED module is available optionally with warm white or
The special DL® 300 LED module is ideally suited for the neutral white light color.
modernizing of existing installations with low effort and sim-
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
2.81
Town and park luminaires | LED luminaires 2
Features Electrics
— LED module including optical cover for especially fast, Luminaire opened without tools | LED module and all electric
simple modernization of existing systems while maintain- components on removable gear tray
ing the uniform appearance
— for standardized lighting according to DIN EN 13201, for “Basic” performance package: LED module with 3-pole
wide luminaire spacing with uniform illumination of the connection terminal, max. 2.5mm² (2-pole for mains supply
road + 1-pole for 230V control voltage for power reduction) |
— LED operating electronics with wide range of functions control signal: USt = 230V → 100% luminous flux; USt = 0V →
for efficient control of luminous flux approx. 50% luminous flux
— minimized energy input with optimal lighting results due
to use of efficient electronic control gear Housing
— highly simple mounting and maintenance: modular gear DL® 300 LED module incl. optical enclosure for upgrading
tray concept, can be simply replaced for upgrading ver- existing luminaires with conventional lamps | PMMA lumi-
sions with conventional lamps to LED or upgrading LED naire cover, transparent or stippled, with bayonet catch |
versions to future, more efficient LED generations insulation class: II | protection rating: identical with the
— long system service life (up to 50,000h) protection rating of the existing luminaire
2.82
2 Town and park luminaires | LED luminaires
272
ø440
LED module incl. optical enclosure for up- — microprocessor-controlled LED operating
grading existing luminaires with conventional electronics
lamps from the DL® 300, DL® 302, DL® 304 — cover of PMMA
and DL® 308 product families — protection rating: as luminaire
— with white LEDs with reflectors, for ho- — insulation class: II
mogeneous, asymmetric wide light distri- — recommended mounting height:
bution; with transparent or stippled cover LPH = 3.5…5m
Control function for light management and monitoring:
• all versions: with temperature monitoring for protection of LEDs from thermal overload, additionally with
• “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
Stippled diffuser
LED 3000 > 80 1225 18 18 9 2.3 Basic 4050737072593 5XA5661E1A2
LED 4700 > 70 1600 18 18 9 2.3 Basic 4050737072555 5XA5661A1A2
2.83
Town and park luminaires | LED luminaires 2
2.84
2 Town and park luminaires | Mast and catenary luminaires
FANTASiE
FANTASiE luminaires are characterized by the formally With the radial faceted reflector and flat cover panel together
matched units of mast mounting element and circular with modern HIT-CE lamps, FANTASiE achieves extremely
luminaire canopy, and their extremely minimized form. Three high system light output ratios with minimized light spill.
stainless steel rods rise up from the mast mounting element An extremely wide distribution configuration with a cycle
to support the circular luminaire canopy. This surrounds the path reflector is available specifically for the lighting of cycle
efficient optics consisting of an efficient radial faceted paths.
reflector and a transparent diffuser or flat cover panel.
Features Electrics
— high potential for saving energy compared to Luminaire with pre-assembled 6m cable for connection of
conventional lantern-design luminaires luminaire in mast terminal box | 2-core supply cable (version
— minimization of stray light immission with use of flat cover with power reduction: 2-core + 1-core for 230V control volt-
panel age) | electrical module with bayonet catch, accessible with-
— ideal for the refurbishment of obsolete systems with use out tools for maintenance purposes; relamping without tools
of standard masts with 76 mm spigot size
— optimized light distribution for illuminating town squares Housing
and for street lighting Housing of glass-fiber-reinforced polyester; diecast alu-
— robust, diecast aluminum mast mounting element minum mast mounting element; all parts with high-quality
— high system light output ratios via radial faceted optics or weather-resistant coating in Siteco® metallic gray (DB 702S)
cycle path reflector for wide luminaire spacing with | supporting elements of V4A steel | housing with bayonet
homogeneous illuminance catch, can be opened without tools for maintenance work |
— tool-free relamping for simple opening of lamp insulation class: II | protection rating: IP65
compartment via rotary catch
— extremely weather-resistant coating Applications
— incl. 6m connection cable — town centers
— parks
Lighting technology — residential areas
Luminaires with flat cover without emission of stray light | — residential streets and collection roads
high system light output ratios via radial faceted optics or — cycle paths
cycle path reflector | radial faceted optics with asymmetric
wide light distribution | reflector unit for cycle paths, asym-
metric extremely wide distribution | optical enclosure as flat
cover panel or diffuser
2.85
Town and park luminaires | Mast and catenary luminaires 2
0%
ø 800
Multiwatt
1162
439
Aw=0,14 m²
FANTASiE
1$(073 with radial faceted optics | with flat cover panel
[+6(://IOP
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
1x TC-TEL 26/32 W GX24q-3/-4 9.8 Multi 4039806908599 5LA31271TS08P
1x HST | HSE | HIT-CE/S-od 70 W 1) E27 16.1 CCG 4039806596611 5NA312E1MT08P
1x HST | HSE 70 W E27 X 16.3 CCG 4039806596635 5NA312E1MT18P
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.86
2 Town and park luminaires | Mast and catenary luminaires
ø 800
1162
439
Aw=0,14 m²
FANTASiE
1$(07
with radial faceted optics | with diffuser
[+6(://IOP
10
& &
/XPLQRXVLQWHQVLW\FODVV
Light source Order no. Order no.
DFFRUGLQJWR
(1* OSRAM Siteco
1x HST | HSE 70 W 1) E27 8.7 CCG 4039806248510 5NA312E1MT08
1x HST | HSE 70 W E27 X 16.3 CCG 4039806248534 5NA312E1MT18
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.87
Town and park luminaires | Mast and catenary luminaires 2
0%
ø 800
1162
439
Aw=0,14 m²
FANTASiE
1$(053
extremely wide distribution for cycle paths | with flat cover panel
[+67 0)://IOP
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
1x HST 70 W E27 X 11.7 CCG 4039806596598 5NA312E1MR18P
1x HST | HIT-CE/S-od 70 W 1) E27 15.8 CCG 4039806596574 5NA312E1MR08P
Mounting height 6m
0RXQWLQJKHLJKWP7LOW
Tilt 0°
O[
P
2.88
2 Town and park luminaires | Mast and catenary luminaires
ø 800
1162
439
Aw=0,14 m²
FANTASiE
1$(05 extremely wide distribution for cycle paths | with diffuser
[+67 0)://IOP
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
1x HST 70 W 1) E27 15.8 CCG 4039806248473 5NA312E1MR08
1x HST 70 W E27 X 16.0 CCG 4039806248497 5NA312E1MR18
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.89
Town and park luminaires | Mast and catenary luminaires 2
for mounting the luminaire to masts with spigot size da = 60mm | reducer of diecast aluminum
da Mounting information
2.90
2 Town and park luminaires | Mast and catenary luminaires
DL® 500
The DL® 500 outdoor luminaire in two construction sizes of specific lighting requirements. Despite its robust
(MIDI, MAXI) for mast or catenary mounting is characterized construction and high IP65 protection rating, the DL® 500
by a modern design, high-quality materials (luminaire hous- luminaire is easy to handle: The lamp cover is opened down-
ing of diecast aluminum) and excellent workmanship. The wards by releasing two robust twist-lock catches. A further
optical system consists of a high-performance radial faceted twist-lock catch secures the gear tray with lamp socket and
reflector and high-grade luminaire cover. This is available lamp that can also be folded downwards. This cuts off the
either as a transparent PMMA diffuser or as a flat cover of power supply; maintenance and control work as well as gear
toughened safety glass designed for maximum light spill re- tray replacement can be carried out without danger. The
duction. The highly efficient optics, combined with HSE/HST efficient radial faceted reflector for extremely wide, asym-
or HIT-CE lamps, allow implementation of wide luminaire metric light distribution can be variably positioned: it can be
distances with homogeneous illumination. The DL® 500 cat- adjusted via simple pushing in the horizontal plane, thus
enary luminaires are equipped either with a symmetrical re- allowing it to be precisely matched to the specific lighting
flector (MAXI) or radial faceted optics (MIDI) for the fulfillment task at hand.
2.91
Town and park luminaires | Mast and catenary luminaires 2
Features Electrics
— family character via two construction sizes with various Cover can be opened without tools and hinged downwards;
lamp possibilities automatic all-pole power disconnection when hinged down-
— luminaire with side-entry, post-top or catenary mounting wards | tool-free relamping | all electric components mount-
with uniform design appearance, for all applications ed on removable gear tray; connection via plug-in coupling |
within a town luminaire wired ready for connection, with 2-pole terminal,
— efficient radial faceted optics for wide luminaire spacing max. 2.5mm² (version with reducing circuit: 2-pole + 1-pole
with highly homogeneous illuminance for 230V control wire, max. 1.5mm²) | optionally with efficient
— radial faceted optics with flat cover panel for minimized electronic control gear (ECG) and Street Light Control (SLC)
light spill light management components (SLC: central control and
— tool-free relamping and gear tray replacement monitoring of intelligent light points) or with CCG with
— minimized energy input with optimal lighting result due to parallel p.f. correction | power reduction: USt = 230V →
use of efficient electronic control gear and Street Light 100% luminous flux; USt = 0V → 50% luminous flux (with
Control (SLC) light management components start in power reduction mode: 100% mode initially for
— all electric components mounted on removable gear tray; approx. 6min.)
gear tray opened without tools and hinged downwards;
automatic all-pole power disconnection when hinged Housing
downwards Luminaire housing and mast mounting of diecast aluminum |
— extremely weather-resistant coating supporting elements of V4A stainless steel | peripheral
EPDM seal in the housing profile | luminaire cover either flat
Lighting technology cover panel of toughened safety glass or enclosure of
Extremely wide light distribution and high uniformity via PMMA | can be opened without tools and hinged down-
highly efficient radial faceted optics | variable light-band de- wards | high-quality weather-resistant coating in Siteco®
flection via adjustable optics | high level of system efficiency metallic gray (DB 702S) | insulation class: II | protection
via optimized light distribution and large luminaire spacings | rating: IP65
optical enclosure is either flat cover panel of toughened
safety glass for minimized light immission, or transparent Applications
diffuser (PMMA) — residential streets and collection roads
— residential areas
— main roads
2.92
2 Town and park luminaires | Mast and catenary luminaires
0%
800
188
350
ø100
ø500
Aw=0,20 m²
Mast luminaire for post-top mounting (DB 702S); cover of toughened safety
— with radial faceted optics, asymmetric glass
wide distribution; with flat cover — type of protection: IP65
— modern electronic control gear (ECG); — insulation class: II
depending on version either with inter- — mast spigot: da = 76 x 100mm
face for dimming luminaire (for external (with reducer: da = 60mm)
SLC luminaire controller in mast) or with — recommended mounting height:
FGNOP
SLC luminaire controller (in luminaire) LPH = 4…6m
— housing and mast connection of diecast — mast connection for twin arrangement
aluminum, Siteco® metallic gray on request
& &
SLC luminaire controller:
/LFKWVWÁUNHNODVVHQDFK • for brightness control of lamps (according to specifications of lamp manufacturer) without supplementary signal line
• SLC luminaire controller in luminaire: control without supplementary signal line via LON PowerLine
(1*
• external SLC luminaire controller (in mast): control without supplementary signal line outside of mast, depending on version via
LON PowerLine or via audio frequency ripple control
• supplementary SLC light management components are required for customer-specific light control and evaluation of signals
regarding operational condition of luminaires and lamps
10
P
2.93
Town and park luminaires | Mast and catenary luminaires 2
0%
800
188
350
ø100
ø500
Aw=0,20 m²
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
1x HIE-CE 35 W E27 13.8 CCG 4039806908001 5NA247E1HT0MS08
1x HST | HSE 50 W 1) E27 14.1 CCG 4039806316356 5NA247E1MT0MS08
1x HST | HSE 70 W E27 X 14.0 CCG 4039806316578 5NA247E1MT1MS08
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.94
2 Town and park luminaires | Mast and catenary luminaires
800
188
280
350
ø100
ø500
Aw=0,20 m²
10
& &
/XPLQRXVLQWHQVLW\FODVV
Light source Order no. Order no.
DFFRUGLQJWR
(1* OSRAM Siteco
1x HST | HSE 50 W 1) E27 13.7 CCG 4039806316387 5NA247E1MT0MW08
1x HST | HSE 70 W E27 X 13.6 CCG 4039806316608 5NA247E1MT1MW08
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.95
Town and park luminaires | Mast and catenary luminaires 2
0%
1150
188
700
ø100
ø500
Aw=0,20 m²
Mast luminaire with supporting structure for (DB 702S); supporting structure elements
post-top mounting of V4A; cover of toughened safety glass
— with radial faceted optics, asymmetric — type of protection: IP65
wide distribution; with flat cover — insulation class: II
— modern electronic control gear (ECG); — mast spigot: da = 76 x 100mm
depending on version either with inter- — recommended mounting height:
face for dimming luminaire (for external LPH = 4…6m
SLC luminaire controller in mast) or with — mast connection for twin arrangement
FGNOP SLC luminaire controller (in luminaire) on request
— housing and mast connection of diecast
aluminum, Siteco® metallic gray
& &
SLC luminaire controller:
/XPLQRXVLQWHQVLW\FODVV • for brightness control of lamps (according to specifications of lamp manufacturer) without supplementary signal line
DFFRUGLQJWR • SLC luminaire controller in luminaire: control without supplementary signal line via LON PowerLine
(1* • external SLC luminaire controller (in mast): control without supplementary signal line outside of mast, depending on version via
LON PowerLine or via audio frequency ripple control
• supplementary SLC light management components are required for customer-specific light control and evaluation of signals
regarding operational condition of luminaires and lamps
10
P
2.96
2 Town and park luminaires | Mast and catenary luminaires
0%
1150
188
700
ø100
ø500
Aw=0,20 m²
Mast luminaire with supporting structure for (DB 702S); supporting structure elements
post-top mounting of V4A; cover of toughened safety glass
— with radial faceted optics, asymmetric — type of protection: IP65
wide distribution; with flat cover — insulation class: II
— with CCG, power-factor-corrected, with — mast spigot: da = 76 x 100mm
power reduction via 230V control voltage — recommended mounting height:
depending on version LPH = 4…6m
— housing and mast connection of diecast — mast connection for twin arrangement
FGNOP aluminum, Siteco® metallic gray on request
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
1x HIE-CE 35 W E27 14.7 CCG 4039806908025 5NA247E1HT0TS08
1x HST | HSE 50 W 1) E27 15.0 CCG 4039806316431 5NA247E1MT0TS08
1x HST | HSE 70 W E27 X 14.9 CCG 4039806316653 5NA247E1MT1TS08
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.97
Town and park luminaires | Mast and catenary luminaires 2
1150
188
280
700
ø100
ø500
Aw=0,20 m²
Mast luminaire with supporting structure for (DB 702S); supporting structure elements
post-top mounting of V4A; PMMA cover
— with radial faceted optics, asymmetric — type of protection: IP65
wide distribution; with diffuser — insulation class: II
— with CCG, power-factor-corrected, with — mast spigot: da = 76 x 100mm
power reduction via 230V control voltage — recommended mounting height:
depending on version LPH = 4…6m
— housing and mast connection of diecast — mast connection for twin arrangement
FGNOP aluminum, Siteco® metallic gray on request
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
1x HST | HSE 50 W 1) E27 14.6 CCG 4039806316462 5NA247E1MT0TW08
1x HST | HSE 70 W E27 X 14.5 CCG 4039806316684 5NA247E1MT1TW08
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.98
2 Town and park luminaires | Mast and catenary luminaires
0%
620
188
ø80
ø500
Aw=0,20 m²
10
P
2.99
Town and park luminaires | Mast and catenary luminaires 2
0%
620
188
ø80
ø500
Aw=0,20 m²
DL® 500 MIDI-A
1$(07$6
[+67 0)://IOP
for side-entry mounting | with radial faceted optics | with cover panel | with CCG
& &
Light source Order no. Order no.
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
OSRAM Siteco
(1* 1x HIE-CE 35 W E27 10.8 CCG 4039806907981 5NA247E1HT0AS08
1x HST | HSE 50 W 1) E27 11.1 CCG 4039806316271 5NA247E1MT0AS08
1x HST | HSE 70 W E27 X 11.0 CCG 4039806316493 5NA247E1MT1AS08
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.100
2 Town and park luminaires | Mast and catenary luminaires
620
188
280
ø80
ø500
Aw=0,20 m²
10
& &
/XPLQRXVLQWHQVLW\FODVV
Light source Order no. Order no.
DFFRUGLQJWR
(1* OSRAM Siteco
1x HST | HSE 50 W 1) E27 10.7 CCG 4039806316288 5NA247E1MT0AW08
1x HST | HSE 70 W E27 X 10.6 CCG 4039806316509 5NA247E1MT1AW08
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.101
Town and park luminaires | Mast and catenary luminaires 2
0%
208
ø500
Aw=0,15 m²
10
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.102
2 Town and park luminaires | Mast and catenary luminaires
0%
208
ø500
Aw=0,15 m²
10
& &
/XPLQRXVLQWHQVLW\FODVV
Light source Order no. Order no.
DFFRUGLQJWR
(1* OSRAM Siteco
1x HIE-CE 35 W E27 10.2 CCG 4039806908018 5NA247E1HT0SS08
1x HST | HSE 50 W 1) E27 8.8 CCG 4039806316417 5NA247E1MT0SS08
1x HST | HSE 70 W E27 X 10.6 CCG 4039806316639 5NA247E1MT1SS08
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.103
Town and park luminaires | Mast and catenary luminaires 2
208
300
ø500
Aw=0,20 m²
& &
Light source Order no. Order no.
/XPLQRXVLQWHQVLW\FODVV
OSRAM Siteco
DFFRUGLQJWR
(1* 1x HST | HSE 50 W 1) E27 8.3 CCG 4039806316424 5NA247E1MT0SW08
1x HST | HSE 70 W E27 X 10.2 CCG 4039806316646 5NA247E1MT1SW08
Mounting height 4.5m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.104
2 Town and park luminaires | Mast and catenary luminaires
0%
237
ø500
Aw=0,15 m²
Catenary luminaire for mounting via plug-in — housing (with integrated plug-in coupling)
coupling of diecast aluminum, Siteco® metallic
— with radial faceted optics, asymmetric gray (DB 702S); cover of toughened
wide distribution; with flat cover safety glass
— with plug-in coupling for automatic — type of protection: IP65
all-pole power disconnection when — insulation class: II
luminaire is hinged downwards — suspension: plug-in coupling integrated
— modern electronic control gear (ECG); within housing
FGNOP depending on version either with inter- — recommended mounting height:
face for dimming of luminaire or with SLC LPH = 4…6m
luminaire controller (in luminaire)
& &
SLC luminaire controller:
/XPLQRXVLQWHQVLW\FODVV • for brightness control of lamps (according to specifications of lamp manufacturer) without supplementary signal line
DFFRUGLQJWR • SLC luminaire controller in luminaire: control without supplementary signal line via LON PowerLine
(1* • supplementary SLC light management components are required for customer-specific light control and evaluation of signals
regarding operational condition of luminaires and lamps
10
P
2.105
Town and park luminaires | Mast and catenary luminaires 2
0%
237
ø500
Aw=0,15 m²
Catenary luminaire for mounting via plug-in — housing (with integrated plug-in coupling)
coupling of diecast aluminum, Siteco® metallic
— with radial faceted optics, asymmetric gray (DB 702S); cover of toughened
wide distribution; with flat cover safety glass
— with plug-in coupling for automatic all- — type of protection: IP65
pole power disconnection when lumi- — insulation class: II
naire is hinged downwards — suspension: plug-in coupling integrated
— with CCG, power-factor-corrected, with within housing
FGNOP power reduction via 230V control voltage — recommended mounting height:
depending on version LPH = 4…6m
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
1x HIE-CE 35 W E27 11.0 CCG 4050737067124 5NA247E1HT0CS08
1x HST | HSE 50 W 1) E27 10.7 CCG 4050737067155 5NA247E1MT0CS08
1x HST | HSE 70 W E27 X 14.6 CCG 4050737067193 5NA247E1MT1CS08
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.106
2 Town and park luminaires | Mast and catenary luminaires
237
326
ø500
Aw=0,20 m²
— with radial faceted optics, asymmetric gray (DB 702S); cover of toughened
wide distribution; with diffuser safety glass
— with plug-in coupling for automatic — type of protection: IP65
all-pole power disconnection when — insulation class: II
luminaire is hinged downwards — suspension: plug-in coupling integrated
— with CCG, power-factor-corrected, with within housing
power reduction via 230V control voltage — recommended mounting height:
depending on version LPH = 4…6m
FGNOP — housing (with integrated plug-in coupling)
of diecast aluminum, Siteco® metallic
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
1x HST | HSE 50 W 1) E27 10.2 CCG 4050737067162 5NA247E1MT0CW08
1x HST | HSE 70 W E27 X 14.1 CCG 4050737067209 5NA247E1MT1CW08
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.107
Town and park luminaires | Mast and catenary luminaires 2
0%
900
210
370
ø100
ø600
Aw=0,28 m²
& &
SLC luminaire controller:
/XPLQRXVLQWHQVLW\FODVV • for brightness control of lamps (according to specifications of lamp manufacturer) without supplementary signal line
DFFRUGLQJWR • SLC luminaire controller in luminaire: control without supplementary signal line via LON PowerLine
(1* • external SLC luminaire controller (in mast): control without supplementary signal line outside of mast, depending on version
via LON PowerLine or via audio frequency ripple control
• supplementary SLC light management components are required for customer-specific light control and evaluation of signals
regarding operational condition of luminaires and lamps
10
Mast-installed controller, LON PowerLine protocol 1.0 4039806896414 5EA3CUE
Mast-installed controller, LON PowerLine and ripple control protocol 0.6 4039806896384 5EA3CLE
Mast-installed controller, ripple control protocol 0.2 4039806896391 5EA3CRE
P
2.108
2 Town and park luminaires | Mast and catenary luminaires
0%
900
210
370
ø100
ø600
Aw=0,28 m²
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
1x HST | HSE 100 W E40 X 17.0 CCG 4039806313324 5NA246E1NT1MS08
1x HST | HSE 150 W E40 X 17.4 CCG 4039806313775 5NA246E1PT1MS08
1x HST | HSE 250 W E40 17.6 CCG 4039806313997 5NA246E1ST0MS08
1x HST | HSE | HIT-CE 100 W 1) E40 16.9 CCG 4039806313102 5NA246E1NT0MS08
1x HST | HSE | HIT-CE 150 W 1) E40 16.9 CCG 4039806313553 5NA246E1PT0MS08
1x HSE 50 W 2) E27 16.4 CCG 4039806312662 5NA246E1MT0MS08
1x HSE 70 W E27 X 16.1 CCG 4039806312884 5NA246E1MT1MS08
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is additionally required
2) ballast with 2x power tapping 50/70W
— please order mast reducer separately if required
Mounting height 6m
0RXQWLQJKHLJKWP7LOW
Tilt 0°
O[
P
2.109
Town and park luminaires | Mast and catenary luminaires 2
900
210
330
370
ø100
ø600
Aw=0,28 m²
10
& &
/XPLQRXVLQWHQVLW\FODVV
Light source Order no. Order no.
DFFRUGLQJWR
(1* OSRAM Siteco
1x HST | HSE 100 W E40 15.9 CCG 4039806313133 5NA246E1NT0MW08
1x HST | HSE 100 W E40 X 16.1 CCG 4039806313355 5NA246E1NT1MW08
1x HST | HSE 150 W E40 15.9 CCG 4039806313584 5NA246E1PT0MW08
1x HST | HSE 150 W E40 X 16.5 CCG 4039806313805 5NA246E1PT1MW08
1x HST | HSE 250 W E40 16.7 CCG 4039806314024 5NA246E1ST0MW08
1x HSE 50 W 1) E27 15.4 CCG 4039806312693 5NA246E1MT0MW08
1x HSE 70 W E27 X 15.1 CCG 4039806312914 5NA246E1MT1MW08
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.110
2 Town and park luminaires | Mast and catenary luminaires
0%
1250
210
720
ø100
ø600
Aw=0,28 m²
Mast luminaire with supporting structure for (DB 702S); supporting structure elements
post-top mounting of V4A; cover of toughened safety glass
— with radial faceted optics, asymmetric — type of protection: IP65
wide distribution; with flat cover — insulation class: II
— modern electronic control gear (ECG); — mast spigot: da = 76 x 100mm
depending on version either with inter- — recommended mounting height:
face for dimming luminaire (for external LPH = 6…8m
SLC luminaire controller in mast) or with — mast connection for twin arrangement
FGNOP SLC luminaire controller (in luminaire) on request
— housing and mast connection of diecast
aluminum, Siteco® metallic gray
& &
SLC luminaire controller:
/XPLQRXVLQWHQVLW\FODVV • for brightness control of lamps (according to specifications of lamp manufacturer) without supplementary signal line
DFFRUGLQJWR • SLC luminaire controller in luminaire: control without supplementary signal line via LON PowerLine
(1* • external SLC luminaire controller (in mast): control without supplementary signal line outside of mast, depending on version via
LON PowerLine or via audio frequency ripple control
• supplementary SLC light management components are required for customer-specific light control and evaluation of signals
regarding operational condition of luminaires and lamps
10
Mast-installed controller, LON PowerLine and ripple control protocol 0.6 4039806896384 5EA3CLE
Mast-installed controller, ripple control protocol 0.2 4039806896391 5EA3CRE
P
2.111
Town and park luminaires | Mast and catenary luminaires 2
0%
1250
210
720
ø100
ø600
Aw=0,28 m²
/XPLQRXVLQWHQVLW\FODVV 10
DFFRUGLQJWR
(1*
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is additionally required
2) ballast with 2x power tapping 50/70W
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.112
2 Town and park luminaires | Mast and catenary luminaires
1250
210
330
720
ø100
ø600
Aw=0,28 m²
Mast luminaire with supporting structure for (DB 702S); supporting structure elements
post-top mounting of V4A; PMMA cover
— with radial faceted optics, asymmetric — type of protection: IP65
wide distribution; with diffuser — insulation class: II
— with CCG, power-factor-corrected, with — mast spigot: da = 76 x 100mm
power reduction via 230V control voltage — recommended mounting height:
depending on version LPH = 6…8m
— housing and mast connection of diecast — mast connection for twin arrangement
FGNOP aluminum, Siteco® metallic gray on request
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
1x HST | HSE 100 W E40 16.9 CCG 4039806313218 5NA246E1NT0TW08
1x HST | HSE 100 W E40 X 17.1 CCG 4039806313430 5NA246E1NT1TW08
1x HST | HSE 150 W E40 16.9 CCG 4039806313669 5NA246E1PT0TW08
1x HST | HSE 150 W E40 X 17.5 CCG 4039806313881 5NA246E1PT1TW08
1x HST | HSE 250 W E40 17.7 CCG 4039806314109 5NA246E1ST0TW08
1x HSE 50 W 1) E27 16.4 CCG 4039806312778 5NA246E1MT0TW08
1x HSE 70 W E27 X 16.2 CCG 4039806312990 5NA246E1MT1TW08
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.113
Town and park luminaires | Mast and catenary luminaires 2
0%
720
210
ø80
ø600
Aw=0,28 m²
10
Mast-installed controller, LON PowerLine and ripple control protocol 0.6 4039806896384 5EA3CLE
Mast-installed controller, ripple control protocol 0.2 4039806896391 5EA3CRE
P
2.114
2 Town and park luminaires | Mast and catenary luminaires
0%
720
210
ø80
ø600
Aw=0,28 m²
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
1x HST | HSE 100 W E40 X 14.8 CCG 4039806313249 5NA246E1NT1AS08
1x HST | HSE 150 W E40 X 15.2 CCG 4039806313690 5NA246E1PT1AS08
1x HST | HSE 250 W E40 15.4 CCG 4039806313911 5NA246E1ST0AS08
1x HST | HSE | HIT-CE 100 W 1) E40 14.7 CCG 4039806313027 5NA246E1NT0AS08
1x HST | HSE | HIT-CE 150 W 1) E40 14.7 CCG 4039806313461 5NA246E1PT0AS08
1x HSE 50 W 2) E27 14.2 CCG 4039806312587 5NA246E1MT0AS08
1x HSE 70 W E27 X 13.9 CCG 4039806312808 5NA246E1MT1AS08
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is additionally required
2) ballast with 2x power tapping 50/70W
— please order mast reducer separately if required
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.115
Town and park luminaires | Mast and catenary luminaires 2
720
210
330
ø80
ø600
Aw=0,28 m²
10
& &
/XPLQRXVLQWHQVLW\FODVV
Light source Order no. Order no.
DFFRUGLQJWR
(1* OSRAM Siteco
1x HST | HSE 100 W E40 13.7 CCG 4039806313034 5NA246E1NT0AW08
1x HST | HSE 100 W E40 X 13.9 CCG 4039806313256 5NA246E1NT1AW08
1x HST | HSE 150 W E40 13.7 CCG 4039806313478 5NA246E1PT0AW08
1x HST | HSE 150 W E40 X 14.3 CCG 4039806313706 5NA246E1PT1AW08
1x HST | HSE 250 W E40 14.5 CCG 4039806313928 5NA246E1ST0AW08
1x HSE 50 W 1) E27 13.2 CCG 4039806312594 5NA246E1MT0AW08
1x HSE 70 W E27 X 12.9 CCG 4039806312815 5NA246E1MT1AW08
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.116
2 Town and park luminaires | Mast and catenary luminaires
0%
229
ø600
Aw=0,21 m²
P
2.117
Town and park luminaires | Mast and catenary luminaires 2
0%
229
ø600
Aw=0,21 m²
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
1x HST 100 W E40 X 14.5 CCG 4039806585967 5NA246E1NT1SR08
1x HST 150 W E40 X 15.9 CCG 4039806586094 5NA246E1PT1SR08
1x HST | HIT-CE 100 W 1) E40 14.8 CCG 4039806585936 5NA246E1NT0SR08
1x HST | HIT-CE 150 W 1) E40 16.7 CCG 4039806586070 5NA246E1PT0SR08
1x HST | HIT-CE 250 W 1) E40 16.1 CCG 4039806866073 5NA246E1ST0SR08
1x HSE 50 W E27 14.0 CCG 4039806585745 5NA246E1JT0SR08
1x HSE 70 W 2) E27 11.8 CCG 4039806585806 5NA246E1MT0SR08
1x HSE 70 W E27 X 13.6 CCG 4039806585837 5NA246E1MT1SR08
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is additionally required
2) ballast with 2x power tapping 50/70W
— please order wire suspension separately
P
2.118
2 Town and park luminaires | Mast and catenary luminaires
0%
260
ø600
Aw=0,21 m²
Catenary luminaire for mounting via plug-in — housing (with integrated plug-in coupling)
coupling of diecast aluminum, Siteco® metallic
— with specular reflector, symmetric wide gray (DB 702S); cover of toughened
distribution; with flat cover safety glass
— with plug-in coupling for automatic — type of protection: IP65
all-pole power disconnection when — insulation class: II
luminaire is hinged downwards — suspension: plug-in coupling integrated
— modern electronic control gear (ECG); within housing
FGNOP depending on version either with inter- — recommended mounting height:
face for dimming of luminaire or with SLC LPH = 6…8m
luminaire controller (in luminaire)
& &
SLC luminaire controller:
/XPLQRXVLQWHQVLW\FODVV • for brightness control of lamps (according to specifications of lamp manufacturer) without supplementary signal line
DFFRUGLQJWR • SLC luminaire controller in luminaire: control without supplementary signal line via LON PowerLine
(1* • supplementary SLC light management components are required for customer-specific light control and evaluation of signals
regarding operational condition of luminaires and lamps
P
2.119
Town and park luminaires | Mast and catenary luminaires 2
0%
260
ø600
Aw=0,21 m²
Catenary luminaire for mounting via plug-in — housing (with integrated plug-in coupling)
coupling of diecast aluminum, Siteco® metallic
— with specular reflector, symmetric wide gray (DB 702S); cover of toughened
distribution; with flat cover safety glass
— with plug-in coupling for automatic all- — type of protection: IP65
pole power disconnection when lumi- — insulation class: II
naire is hinged downwards — suspension: plug-in coupling integrated
— with CCG, power-factor-corrected, with within housing
FGNOP power reduction via 230V control voltage — recommended mounting height:
depending on version LPH = 6…8m
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
1x HST 100 W E40 X 14.8 CCG 4050737067698 5NA246E1NT1CR08
1x HST 150 W E40 X 16.2 CCG 4050737067827 5NA246E1PT1CR08
1x HST | HIT-CE 100 W 1) E40 14.8 CCG 4050737067629 5NA246E1NT0CR08
1x HST | HIT-CE 150 W 1) E40 16.2 CCG 4050737067759 5NA246E1PT0CR08
1x HST | HIT-CE 250 W E40 15.6 CCG 4050737067896 5NA246E1ST0CR08
1x HSE 50 W E27 14.0 CCG 4050737067438 5NA246E1JT0CR08
1x HSE 70 W 2) E27 12.3 CCG 4050737067483 5NA246E1MT0CR08
1x HSE 70 W E27 X 12.2 CCG 4050737067551 5NA246E1MT1CR08
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is additionally required
2) ballast with 2x power tapping 50/70W
— please order wire suspension with plug-in coupling separately
— the specifi ed luminaires can only be used in combination with the wire suspension specifi ed below
P
2.120
2 Town and park luminaires | Mast and catenary luminaires
for mounting DL® 500 …- M | … -T | … -A luminaire to mast with spigot size da = 60mm
(post-top) or spigot size da = 42mm (side-entry) | reducer of diecast aluminum
l DL® 500 … -A
Mast spigot: da x l = 60 x 100mm (luminaire mounting possible without reducer)
da
2.121
Town and park luminaires | Mast and catenary luminaires 2
Luminaire can be swiveled in one axis | without electrics | suspension of cast aluminum,
Siteco® metallic gray (DB 702S) | suitable for cable d = 5…12mm
72
36°
33
R½
Luminaire can be swiveled/rotated in two axes | without electrics | suspension of cast alumi-
num, Siteco® metallic gray (DB 702S); V4A mounting bracket | suitable for cable d = 5…12mm
350
90
24°
R½
60
360°
2.122
2 Town and park luminaires | Mast and catenary luminaires
Luminaire can be swiveled/rotated in two axes | with 2x M20 side cable entry for cable
diameter d = 7…13mm; prepared for through-wiring; with 4-pole connection terminal, max.
2.5mm² | mains disconnection when luminaire is hinged downwards via inner connector |
housing of cast aluminum, Siteco® metallic gray (DB 702S); mounting bracket of V4A |
protection rating: IP65 | insulation class: II | suitable for cable da = 5…12mm
350
126
24°
360°
Diffuser for
DL 500 MIDI 0.4 4039806087577 5NA24700XW
DL 500 MAXI 0.5 4039806087553 5NA24600XW
1) for HIT-CE-od lamp configuration (non-printed or part-printed light emission aperture: 213 x 260mm)
2) for all lamp configurations except HIT-CE-od (non-printed or part-printed light emission aperture: 253 x 298mm)
3) non-printed or part-printed light emission aperture: 346 x 322mm
For detailed information about intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires, see Chapter 6 are specified in Chapter 7
2.123
Town and park luminaires | Mast and catenary luminaires 2
2.124
2 Town and park luminaires | Mast and catenary luminaires
CITY-LIGHT
The post-top luminaires of the CITY-LIGHT family interpret Thanks to the exchangeable electrical insert, the luminaire
the form of the classic lanterns into a new and contempo- can be equipped with various HIE-CE, HSE and TC-LEL
rary type. The result is an installation-friendly, modular lumi- lamps or with the LED Module 520.
naire with elegant, transparent looks and modern lighting
technology. The light emission aperture above the canopy Most optical components and electrical inserts and the LED
sets a special accent to create an interesting night effect. Module 520 for this luminaire family can be interchanged
and are identical to components of the other luminaire rang-
The luminaire consists of two different upper housing parts es LANTERN, LANTERN CLASSIC, LANTERN DELUXE,
(PLUS, ELEGANCE), with the white underside of the canopy MUSHROOM LUMINAIRE, CITY-LIGHT BOLLARD 120 and
serving as reflector. Two various housing canopies complete 120E and the CITY-LIGHT PILLAR 260, enabling outstand-
the construction. In addition, optical enclosures of transpar- ing availability of replacement parts and the rapid, mainte-
ent or frosted PMMA, various fan-shaped reflectors and a nance-friendly exchange of individual components along
shield are available for various light distribution patterns. with greater design flexibility.
New:
LED town and parc luminaires with new LED Module 540
Ready for order: Q3/2014
Detailed information:
www.siteco.com/LEDModule540
2.125
Town and park luminaires | Mast and catenary luminaires 2
Features Electrics
— as CITY-LIGHT LED also with energy-efficient LED Cover opened without tools | luminaire insert with all electric
technology components as removable unit | luminaire insert with 2-pole
— many applications possible thanks to timeless design, connection terminal (version with reducing circuit: 2-pole +
various reflectors and suitable mast and wall brackets 1-pole for 230V control wire), max. 2.5mm² | power
— very good night effect via additional light emission above reduction: USt = 230V → 100% luminous flux; USt = 0V →
canopy 50% luminous flux (with start in power reduction mode:
— optionally with attractive optical enclosure of PMMA, 100% mode initially for approx. 6min.)
frosted or transparent
— especially installation-friendly with self-centering mast Housing
mounting element (one-point mast connection) Self-centering mast mounting element of diecast aluminum;
— modular construction enables simplified replacement of glass-fiber-reinforced polyester canopy element; housing
parts; electrical block identical with that of LANTERN and and canopy with weather-resistant coating in Siteco® metal-
MUSHROOM LUMINAIRE lic gray (DB 702S); canopy underside in white, functions as
— tool-free relamping and access to electrical control reflector; supporting elements of aluminum | cover of im-
components pact-resistant, UV-stabilized PMMA, transparent or frosted |
— extremely weather-resistant coating in Siteco® metallic insulation class: I or II | protection rating: IP54
gray (DB 702S)
Applications
Lighting technology — town centers
open distribution luminaire with transparent or frosted — parks
cover | the lighting characteristic is defined via fan-shaped — residential areas
reflectors or shields: — residential streets and collection roads
— rotationally symmetrical wide distribution with fan-shaped
reflector
— asymmetric wide distribution with shielding on building
side
— rotationally symmetrical wide distribution with extremely
reduced luminance in the horizontal plane via shield
— canopy underside in white, functions as reflector
2.126
2 Town and park luminaires | Mast and catenary luminaires
ø750
590
Aw=0,15 m²
ø185
ø280
/XPLQRXVLQWHQVLW\FODVV 10
DFFRUGLQJWR
(1
P
2.127
Town and park luminaires | Mast and catenary luminaires 2
ø750
590
Aw=0,15 m²
ø185
ø280
P
2.128
2 Town and park luminaires | Mast and catenary luminaires
2.129
Town and park luminaires | Mast and catenary luminaires 2
ø750
675
Aw=0,15 m²
ø185
ø280
P
2.130
2 Town and park luminaires | Mast and catenary luminaires
2.131
Town and park luminaires | Mast and catenary luminaires 2
ø750
675
Aw=0,15 m²
ø185
ø280
2.132
2 Town and park luminaires | Mast and catenary luminaires
for high-pressure lamps (1x HSE 50/70W or 1x HIE-CE-P 35/70W) | symmetric distribution |
incl. anti-glare ring for covering control gear block
Special reflector shield for min. light immission 0.5 4039806498687 5NA52600XS01
[+6(:φOP
& &
/LFKWVWÁUNHNODVVHQDFK
(1*
Fan-shaped reflector
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[+6(:φOP [+6(:φOP
/LFKWVWÁUNHNODVVHQDFK /LFKWVWÁUNHNODVVHQDFK
(1 (1
2.133
Town and park luminaires | Mast and catenary luminaires 2
Lamp shield
for high-pressure lamps (1x HSE 50/70W or 1x HIE-CE-P 35/70W) | symmetric distribution |
incl. anti-glare ring for covering control gear block
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[+6(://φOP
& &
/LFKWVWÁUNHNODVVHQDFK
(1*
Fan-shaped reflector
for compact fluorescent lamps (2x TC-LEL 18/24W) | symmetric or asymmetric distribution
(with shielding on building side) | incl. anti-glare ring for covering control gear block
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[7&/(/:φOP [7&/(/:φOP
/LFKWVWÁUNHNODVVHQDFK /LFKWVWÁUNHNODVVHQDFK
(1* (1
2.134
2 Town and park luminaires | Mast and catenary luminaires
for mounting the luminaire* to masts with spigot size da = 60mm | reducer of diecast aluminum
* for all versions of CITY-LIGHT, LANTERN and MUSHROOM LUMINAIRE from year of construction 2002 (luminaire fixing with 1 fixing
screw)
da Mounting information
Optical enclosure
For detailed information about intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires, see Chapter 6 are specified in Chapter 7
2.135
Town and park luminaires | Mast and catenary luminaires 2
2.136
2 Town and park luminaires | Mast and catenary luminaires
LANTERN
The post-top luminaires of the LANTERN family reinterpret Thanks to the exchangeable electrical insert, the luminaire
the form of the classic mushroom luminaire. The result is an can be equipped with various HIE-CE, HSE and TC-LEL
installation-friendly, modular luminaire with an elegant, lamps or with the LED Module 520.
transparent appearance and modern lighting technology.
Most optical components and electrical inserts and the LED
With its daylight effect, it blends discreetly in with modern ar- Module 520 for this luminaire family can be interchanged
chitecture but also successfully with historical surroundings. and are identical to components of the other luminaire rang-
The luminaire consists of a canopy that can be combined es CITY-LIGHT PLUS, CITY-LIGHT ELEGANCE, MUSH-
either with one of the two housings (DELUXE, CLASSIC) or ROOM LUMINAIRE, CITY-LIGHT BOLLARD 120 and 120E
singly with one of the two transparent or pearled covers of and the CITY-LIGHT PILLAR 260, enabling outstanding
PMMA. In addition, various fan-shaped reflectors and a availability of replacement parts and the rapid, maintenance-
shield are available for various light distribution patterns. friendly exchange of individual components along with
greater design flexibility.
New:
LED town and parc luminaires with new LED Module 540
Ready for order: Q3/2014
Detailed information:
www.siteco.com/LEDModule540
2.137
Town and park luminaires | Mast and catenary luminaires 2
Features Electrics
— many applications possible (town squares, service roads, Cover opened without tools | luminaire insert with all electric
collection roads) thanks to various reflectors and suitable components as removable unit | luminaire insert with 2-pole
mast and wall brackets connection terminal (version with reducing circuit: 2-pole +
— application-adapted day and night-time effect with 1-pole for 230V control wire), max. 2.5mm² | power reduc-
varying optical enclosures or versions with additional tion: USt = 230V → 100% luminous flux; USt = 0V → 50%
steel supporting elements luminous flux (with start in power reduction mode: 100%
— especially installation-friendly with self-centering mast mode initially for approx. 6min.)
mounting element and one-point mast connection
— modular construction enables simplified replacement of Housing
parts; electrical block identical with that of CITY-LIGHT Self-centering mast mounting element of diecast aluminum;
and MUSHROOM LUMINAIRE glass-fiber-reinforced polyester canopy element; housing
— modification of light distribution via simple reflector and canopy with weather-resistant coating in Siteco® metal-
replacement lic gray (DB 702S); canopy underside in white, functions as
— tool-free relamping and access to electrical control reflector | cover of impact-resistant, UV-stabilized PMMA,
components transparent or pearled | insulation class: I or II | protection
— as LANTERN LED also with energy-efficient LED rating: IP54
technology
— extremely weather-resistant coating in Siteco® metallic Applications
gray (DB 702S) — town centers
— parks
Lighting technology — residential areas
open distribution luminaire with transparent or pearled — residential streets and collection roads
cover | the lighting characteristic is defined via fan-shaped
reflectors or shields:
— rotationally symmetrical wide distribution with fan-shaped
reflector
— asymmetric wide distribution with shielding on building
side
— rotationally symmetrical wide distribution with extremely
reduced luminance in the horizontal plane via shield
— canopy underside in white, functions as reflector
2.138
2 Town and park luminaires | Mast and catenary luminaires
ø750
583
320
Aw=0,16 m²
ø185
LANTERN
1$(061$;6
with transparent cover
[+6(://IOP
/XPLQRXVLQWHQVLW\FODVV 10
DFFRUGLQJWR
(1*
P
2.139
Town and park luminaires | Mast and catenary luminaires 2
ø750
583
320
Aw=0,16 m²
ø185
LANTERN
1$(05
with pearl cover
[+6(://IOP
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
Insulation class I (protective earthing)
2x TC-LEL 18/24 W 2G11 11.2 CCG 4039806278388 5LA52422KF18
1x HSE 50 W 1) E27 11.5 CCG 4039806441874 5NA524E1MF18
2x HSE 50 W E27 13.2 CCG 4039806332509 5NA524E2MF18
1x HSE 70 W E27 X 11.6 CCG 4039806332288 5NA524E1MR18
1x HSE 100 W E40 12.0 CCG 4039806332387 5NA524E1NF18
1x HSE 100 W E40 X 12.1 CCG 4039806332417 5NA524E1NR18
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Shielding on building side, asymmetric distribution, for 1x HME | HSE 0.5 4039806059284 5NA53200XB
P
Asymmetric reflector, asymmetric distribution, for 1x HME | HSE 0.5 4039806059482 5NA54701XS
Asymmetric reflector, asymmetric wide distribution, for 2x HME | HSE 0.6 4039806059505 5NA54702XS
2.140
2 Town and park luminaires | Mast and catenary luminaires
ø750
596
Aw=0,16 m²
ø185
ø270
10
& &
/XPLQRXVLQWHQVLW\FODVV
Light source Order no. Order no.
DFFRUGLQJWR
(1 OSRAM Siteco
Insulation class I (protective earthing)
1x HSE 50 W 1) E27 16.4 CCG 4039806340672 5NA526E1MF48
2x HSE 50 W 1) E27 18.1 CCG 4039806341396 5NA526E2MF48
1x HSE 70 W E27 X 16.5 CCG 4039806340795 5NA526E1MR48
1x HSE 100 W E40 16.9 CCG 4039806341037 5NA526E1NF48
1x HSE 100 W E40 X 17.0 CCG 4039806341150 5NA526E1NR48
Mandatory accessories (for details see page 2.144 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Shielding on building side, asymmetric distribution, for 1x HME | HSE 0.5 4039806059284 5NA53200XB
P
Asymmetric reflector, asymmetric distribution, for 1x HME | HSE 0.5 4039806059482 5NA54701XS
Asymmetric reflector, asymmetric wide distribution, for 2x HME | HSE 0.6 4039806059505 5NA54702XS
2.141
Town and park luminaires | Mast and catenary luminaires 2
ø750
596
Aw=0,16 m²
ø185
ø270
P
2.142
2 Town and park luminaires | Mast and catenary luminaires
2.143
Town and park luminaires | Mast and catenary luminaires 2
Special reflector shield for minimized light immission for transparent cover
for high-pressure lamps (1x HSE 50/70W or 1x HIE-CE-P 35/70W) | symmetric distribution |
incl. anti-glare ring for covering control gear block
Special reflector shield for min. light immission 0.5 4039806498670 5NA52400XS
[+6(:φOP
& &
/LFKWVWÁUNHNODVVHQDFK
(1*
for high-pressure lamps (1x HSE 50/70/100W or 1x HIE-CE-P 35/70W) | symmetric distri-
bution or asymmetric distribution (with shielding on building side) | incl. anti-glare ring for
covering control gear block
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[+6(:φOP [+6(:φOP
/LFKWVWÁUNHNODVVHQDFK /LFKWVWÁUNHNODVVHQDFK
(1* (1
2.144
2 Town and park luminaires | Mast and catenary luminaires
for high-pressure lamps (1x HSE 50/70W or 1x HIE-CE-P 35/70W) | symmetric distribution |
incl. anti-glare ring for covering control gear block
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[+6(:φOP
& &
/LFKWVWÁUNHNODVVHQDFK
(1*
for high-pressure lamps (1x HSE 50/70/100W or 2x HSE 50/70W) | asymmetric distribution
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[+6(:φOP [+6(:φOP
/LFKWVWÁUNHNODVVHQDFK /LFKWVWÁUNHNODVVHQDFK
(1 (1
2.145
Town and park luminaires | Mast and catenary luminaires 2
for high-pressure lamps or compact fluorescent lamps (1x HSE 50/70W or 2x TC-LEL
18/24W) | asymmetric distribution
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[+6(:φOP
& &
/LFKWVWÁUNHNODVVHQDFK
(1
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
Fan-shaped reflector
for TC lamps F6 0.4 4039806072207 5NA52005XS
for TC lamps with shielding on building side F6H 0.4 4039806072221 5NA52005XS1
[7&/(/:φOP [7&/(/:φOP
/LFKWVWÁUNHNODVVHQDFK /LFKWVWÁUNHNODVVHQDFK
(1* (1
2.146
2 Town and park luminaires | Mast and catenary luminaires
for mounting the luminaire* to masts with spigot size da = 60mm | reducer of diecast aluminum
* for all versions of CITY-LIGHT, LANTERN and MUSHROOM LUMINAIRE from year of construction 2002 (luminaire fixing with 1 fixing
screw)
da Mounting information
Optical cover
For detailed information about intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires, see Chapter 6 are specified in Chapter 7
2.147
Town and park luminaires | Mast and catenary luminaires 2
2.148
2 Town and park luminaires | Mast and catenary luminaires
MUSHROOM LUMINAIRE
The classic MUSHROOM LUMINAIRE has been carefully Most optical components and electrical inserts and the LED
and consistently developed under consideration of its spe- Module 520 for this luminaire family can be interchanged
cial, original luminaire form. The result is an installation- and are identical to components of the other luminaire rang-
friendly, modular luminaire with an elegant, classic appear- es CITY-LIGHT PLUS, CITY-LIGHT ELEGANCE, LANTERN,
ance and modern lighting technology. LANTERN CLASSIC, LANTERN DELUXE, CITY-LIGHT
BOLLARD 120 and 120E and the CITY-LIGHT PILLAR 260,
The MUSHROOM LUMINAIRE consists of a housing canopy 260E and 260D, enabling outstanding availability of replace-
combined with transparent, frosted or opal plastic covers. ment parts and the rapid, maintenance-friendly exchange of
In addition, various fan-shaped reflectors and a shield are individual components along with greater design flexibility.
available for various light distribution patterns. With the
exchangeable electrical insert, the luminaire can be
equipped with various HIE-CE, HSE and TC-LEL lamps or
with the LED Module 520.
New:
LED town and parc luminaires with new LED Module 540
Ready for order: Q3/2014
Detailed information:
www.siteco.com/LEDModule540
2.149
Town and park luminaires | Mast and catenary luminaires 2
Features Electrics
— many applications possible (town squares, service roads, Cover opened without tools | luminaire insert with all electric
collection roads) thanks to various reflectors and suitable components as removable unit | luminaire insert with 2-pole
mast and wall brackets connection terminal (version with reducing circuit: 2-pole +
— classic design with formal autonomy 1-pole for 230V control wire), max. 2.5mm² | power reduc-
— situation-adapted day and night-time effect via three tion: USt = 230V → 100% luminous flux; USt = 0V → 50%
different covers: transparent, frosted or opal luminous flux (with start in power reduction mode: 100%
— especially installation-friendly via self-centering mast mode initially for approx. 6min.)
mounting element and one-point mast connection
— modular construction enables simplified replacement of Housing
parts; electrical block identical with that of CITY-LIGHT Self-centering mast mounting element of diecast aluminum;
and LANTERN glass-fiber-reinforced polyester canopy element; housing
— tool-free relamping and access to electrical control and canopy with weather-resistant coating in Siteco® metal-
components lic gray (DB 702S); canopy underside in white, functions as
— as MUSHROOM LUMINAIRE LED also with energy- reflector | cover of impact-resistant PMMA, transparent,
efficient LED technology frosted or opal | insulation class: II | protection rating: IP54
2.150
2 Town and park luminaires | Mast and catenary luminaires
ø650
586
Aw=0,14 m²
ø185
— please order fan-shaped refl ector or shade separately
— luminaire color Siteco ® metallic gray (DB 702S) as standard | for luminaire color black (RAL 9005), please replace number
“8” at the end of the order number with “1”; for light gray (RAL 7035), use number “5”. Corresponding OSRAM order
P number on request.
ø650
586
Aw=0,14 m²
ø185
1) ballast with 2x power tapping 50/70W
— please order fan-shaped refl ector or shade separately
— luminaire color Siteco ® metallic gray (DB 702S) as standard | for luminaire color black (RAL 9005), please replace number
“8” at the end of the order number with “1”; for light gray (RAL 7035), use number “5”. Corresponding OSRAM order
number on request.
P
2.152
2 Town and park luminaires | Mast and catenary luminaires
2.153
Town and park luminaires | Mast and catenary luminaires 2
ø650
586
Aw=0,14 m²
ø185
MUSHROOM LUMINAIRE
1$(0)
[+6(://IOP
with opal cover
Mandatory accessories (for details see page 2.155 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
P
Shielding on building side, asymmetric distribution, for 1x HME | HSE 0.5 4039806059284 5NA53200XB
2.154
2 Town and park luminaires | Mast and catenary luminaires
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[+6(:φOP [+6(:φOP
/LFKWVWÁUNHNODVVHQDFK /LFKWVWÁUNHNODVVHQDFK
(1* (1
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[+6(:φOP
& &
/LFKWVWÁUNHNODVVHQDFK
(1*
2.155
Town and park luminaires | Mast and catenary luminaires 2
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[+6(:φOP
& &
/LFKWVWÁUNHNODVVHQDFK
(1
for compact fluorescent lamps (2x TC-LEL 18/24W) | symmetric or asymmetric distribution
(with shielding on building side) | incl. anti-glare ring for covering control gear block
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[7&/(/:φOP [7&/(/:φOP
/LFKWVWÁUNHNODVVHQDFK /LFKWVWÁUNHNODVVHQDFK
(1* (1*
2.156
2 Town and park luminaires | Mast and catenary luminaires
for mounting the luminaire* to masts with spigot size da = 60mm | reducer of diecast aluminum
* for all versions of CITY-LIGHT, LANTERN and MUSHROOM LUMINAIRE from year of construction 2002 (luminaire fixing with 1 fixing
screw)
da Mounting information
Optical cover
For detailed information about intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires, see Chapter 6 are specified in Chapter 7
2.157
Town and park luminaires | Mast and catenary luminaires 2
2.158
2 Town and park luminaires | Mast and catenary luminaires
BELL
The BELL luminaires are characterized by an organic, In addition, various reflectors such as pagoda reflectors, fan-
curved and elegant form. As such, they blend harmoniously shaped reflectors and radial faceted optics are available for
into various architectural surroundings ranging from modern various light distribution patterns. An extremely wide distri-
cities to heritage structures. The installation-friendly, modu- bution configuration with a cycle path reflector is available
lar luminaire with modern lighting technology is a suitable specifically for the lighting of cycle paths. All components
alternative to the classic post-top luminaire. The luminaire can be interchanged thanks to outstanding availability of
consists of a housing in two construction sizes, and can be replacement parts and the rapid, maintenance-friendly ex-
combined with a semi-spherical cover of PMMA, transpar- change of components, allowing greater flexibility for design.
ent or stippled.
2.159
Town and park luminaires | Mast and catenary luminaires 2
Features Electrics
— family character via two construction sizes Electrical insert as complete unit including all electrical com-
— different day and night-time effects via various diffuser ponents | luminaire insert with 2-pole connection terminal
versions (version with reducing circuit: 2-pole + 1-pole for 230V con-
— flexible lighting technology via various reflector inserts, trol wire), max. 2.5mm² | power reduction: USt = 230V →
rotationally symmetric or asymmetric, optionally with 100% luminous flux; USt = 0V → 50% luminous flux (with
shielding on building side start in power reduction mode: 100% mode initially for
— bayonet catch allows rapid mounting of BELL to curved approx. 6min.) | tool-free relamping
mast extension
— tool-free relamping Housing
— multiple arrangement possible Glass-fiber reinforced polyester housing with integral bayo-
net connection; curved mast extension; luminaire-specific
Lighting technology Siteco® curved mast extension, steel, galvanized; housing
optical versions via combinations of cover and reflector and curved mast extension with weather-resistant coating in
insert for suspended or side-mounted lamps Siteco® metallic gray (DB 702S) | housing underside in white,
— pendant lamp: open distribution; rotationally symmetric functions as reflector | all-round, air-permeable wool-felt
wide distribution via fan-shaped reflector or pagoda re- gasket in housing profile | PMMA luminaire cover in two
flector, and asymmetric wide distribution (with shielding versions, with bayonet catch | insulation class: II | protection
on building side) via fan-shaped reflector or asymmetric rating: IP54
reflector
— side-mounted lamp: asymmetric extremely wide Applications
distribution — parks
— transparent or stippled optical enclosure — residential areas
— with reflector unit for cycle paths, asymmetric extremely — residential streets and collection roads
wide distribution — cycle paths
— all reflector inserts inserted without tools
2.160
2 Town and park luminaires | Mast and catenary luminaires
410
575
Aw=0,10 m²
ø430
Luminaire for suspended mounting on corrected, with power reduction via 230V
curved mast extension or wall bracket control voltage depending on version
— open distribution, with transparent cover; — luminaire housing of glass-fiber-rein-
symmetric wide distribution via fan- forced polyester; Siteco® metallic gray
shaped reflector or pagoda reflector, (DB 702S); cover of PMMA
asymmetric wide distribution (with re- — type of protection: IP54
duced light emission into the rear area) — insulation class: II
via fan-shaped reflector with shielding on — luminaire suitable for curved mast exten-
building side or via asymmetric reflector; sion with single or twin arrangements
FGNOP fan-shaped reflector and pagoda and wall bracket with bayonet catch
reflector with light distribution directed — recommended mounting height:
downwards; with CCG, power-factor- LPH = 3.5…5m
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
P
2.161
Town and park luminaires | Mast and catenary luminaires 2
410
575
Aw=0,10 m²
ø430
Mandatory accessories (for details see page 2.168 ff.)
0RXQWLQJKHLJKWP7LOW
O[
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Bell arc, inline, 1-arm, spigot size: 60mm 6.6 4039806215215 5NY15711XX08
Bell arc, inline, 1-arm, spigot size: 76mm 7.5 4039806215451 5NY15721XX08
Bell arc, inline, 2-arm, spigot size: 76mm 13.3 4039806370747 5NY15722XX08
Bell arc, offset, 1-arm, spigot size: 60mm 5.4 4039806215055 5NY15711XA08
Bell arc, offset, 1-arm, spigot size: 76mm 6.3 4039806215291 5NY15721XA08
Bell arc, offset, 2-arm, spigot size: 76mm 9.3 4039806215536 5NY15722XA08
Bell arc, standard, 1-arm, spigot size: 60mm 5.1 4039806215130 5NY15711XF08
Bell arc, standard, 1-arm, spigot size: 76mm 4.9 4039806215376 5NY15721XF08
P
Wall bracket, 1-arm 6.3 4039806214898 5NY15701XW08
2.162
2 Town and park luminaires | Mast and catenary luminaires
410
575
Aw=0,10 m²
ø430
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
Stippled diffuser
1x HST 50 W 1) E27 6.6 CCG with thermal protection 4039806295422 5NA157E1ME208
1x HST 70 W E27 X 7.0 CCG with thermal protection 4039806295484 5NA157E1MF208
Transparent diffuser
1x HST 50 W 1) E27 6.7 CCG with thermal protection 4039806295392 5NA157E1ME108
1x HST 70 W E27 X 7.1 CCG with thermal protection 4039806295453 5NA157E1MF108
Bell arc, offset, 1-arm, spigot size: 76mm 6.3 4039806215291 5NY15721XA08
Bell arc, offset, 2-arm, spigot size: 76mm 9.3 4039806215536 5NY15722XA08
Bell arc, standard, 1-arm, spigot size: 60mm 5.1 4039806215130 5NY15711XF08
P
Bell arc, standard, 1-arm, spigot size: 76mm 4.9 4039806215376 5NY15721XF08
Wall bracket, 1-arm 6.3 4039806214898 5NY15701XW08
2.163
Town and park luminaires | Mast and catenary luminaires 2
500
695
Aw=0,15 m²
ø530
Mounting height 4m Tilt 0°
Designation Wt. (kg) Order no. Order no.
0RXQWLQJKHLJKWP7LOW
O[
OSRAM Siteco
Asymmetric reflector, asymmetric extremely wide distribution, for 1x HME | HSE 0.3 4039806456571 5NA14000XS7
Pagoda reflector, symmetric wide distribution, for 1x HME | HSE 0.3 4039806055217 5NA14000XS2
Pagoda reflector, asymmetric wide distribution, for 1x HME | HSE 0.5 4039806055231 5NA14000XS21
Fan-shaped reflector, symmetric wide distribution, for 1x TC-LEL 0.5 4039806055255 5NA14000XS3
P
Fan-shaped reflector, asymmetric wide distribution, for 1x TC-LEL 0.9 4039806055279 5NA14000XS31
Fan-shaped reflector, symmetric wide distribution, for 1/2x TC-LEL 1.0 4039806055293 5NA14000XS4
Fan-shaped reflector, asymmetric wide distribution, for 1/2x TC-LEL 1.0 4039806055316 5NA14000XS41
Shielding on building side, asymmetric distribution, for 1x HME | HSE 0.1 4039806055132 5NA14000XB0
2 Town and park luminaires | Mast and catenary luminaires
500
695
Aw=0,15 m²
ø530
Mandatory accessories (for details see page 2.168 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Asymmetric reflector, asymmetric extremely wide distribution, for 1x HME | HSE 0.3 4039806456571 5NA14000XS7
Pagoda reflector, symmetric wide distribution, for 1x HME | HSE 0.3 4039806055217 5NA14000XS2
Pagoda reflector, asymmetric wide distribution, for 1x HME | HSE 0.5 4039806055231 5NA14000XS21
Fan-shaped reflector, symmetric wide distribution, for 1x TC-LEL 0.5 4039806055255 5NA14000XS3
Fan-shaped reflector, asymmetric wide distribution, for 1x TC-LEL 0.9 4039806055279 5NA14000XS31
P
Fan-shaped reflector, symmetric wide distribution, for 1/2x TC-LEL 1.0 4039806055293 5NA14000XS4
Fan-shaped reflector, asymmetric wide distribution, for 1/2x TC-LEL 1.0 4039806055316 5NA14000XS41
2.165 Shielding on building side, asymmetric distribution, for 1x HME | HSE 0.1 4039806055132 5NA14000XB0
Town and park luminaires | Mast and catenary luminaires 2
500
695
Aw=0,15 m²
ø530
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
Stippled diffuser
1x HST | HSE 50 W 1) E27 9.1 CCG with thermal protection 4039806293800 5NA156E1ML208
1x HST | HSE 70 W E27 X 9.2 CCG with thermal protection 4039806293749 5NA156E1MK208
1x HSE 100 W E40 X 10.0 CCG with thermal protection 4039806293893 5NA156E1NK208
1x HSE 100 W E40 9.7 CCG with thermal protection 4039806293954 5NA156E1NL208
Transparent diffuser
1x HST | HSE 50 W 1) E27 9.3 CCG with thermal protection 4039806293770 5NA156E1ML108
1x HST | HSE 70 W E27 X 9.3 CCG with thermal protection 4039806293718 5NA156E1MK108
1x HSE 100 W E40 X 10.1 CCG with thermal protection 4039806293862 5NA156E1NK108
1x HSE 100 W E40 9.8 CCG with thermal protection 4039806293923 5NA156E1NL108
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0° Mandatory accessories (for details see page 2.168 ff.)
O[
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Bell arc, inline, 1-arm, spigot size: 76…89mm 12.8 4039806214737 5NY15621XX08
Bell arc, inline, 2-arm, spigot size: 76…89mm 23.2 4039806370624 5NY15622XX08
P
Bell arc, offset, 1-arm, spigot size: 76mm 10.3 4039806214577 5NY15621XA08
Bell arc, offset, 2-arm, spigot size: 76mm 13.5 4039806214812 5NY15622XA08
Bell arc, standard, 1-arm, spigot size: 76mm 9.6 4039806214652 5NY15621XF08
Wall bracket, 1-arm 13.0 4039806214416 5NY15601XW08
2 Town and park luminaires | Mast and catenary luminaires
500
695
Aw=0,15 m²
ø530
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
Stippled diffuser
1x HST 50 W 1) E27 8.3 CCG with thermal protection 4039806293626 5NA156E1ME208
1x HST 70 W E27 X 8.7 CCG with thermal protection 4039806293688 5NA156E1MF208
Transparent diffuser
1x HST 50 W 1) E27 8.4 CCG with thermal protection 4039806293596 5NA156E1ME108
1x HST 70 W E27 X 8.8 CCG with thermal protection 4039806293657 5NA156E1MF108
P
2.167
Town and park luminaires | Mast and catenary luminaires 2
Pagoda reflector
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[+6(:φOP [+6(:φOP
/LFKWVWÁUNHNODVVHQDFK /LFKWVWÁUNHNODVVHQDFK
(1* (1*
Asymmetric reflector
for high-pressure lamp (1x HSE 50/70W) | asymmetric distribution; adjustable shielding
direction
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[+6(:φOP
& &
/LFKWVWÁUNHNODVVHQDFK
(1*
2.168
2 Town and park luminaires | Mast and catenary luminaires
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
for compact fluorescent lamps (2x TC-LEL 18W) | symmetric or asymmetric distribution
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[7&/(/:φOP [7&/(/:φOP
/LFKWVWÁUNHNODVVHQDFK /LFKWVWÁUNHNODVVHQDFK
(1* (1*
2.169
Town and park luminaires | Mast and catenary luminaires 2
for compact fluorescent lamps (2x TC-LEL 18/24W) | symmetric or asymmetric distribution
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[7&/(/:φOP [7&/(/:φOP
/LFKWVWÁUNHNODVVHQDFK /LFKWVWÁUNHNODVVHQDFK
(1* (1*
Mast mounting element with clamp | twin fixing to mast, fixing with grub screws | steel,
galvanized and coated, Siteco® metallic gray (DB 702S)* | suitable for cylindrical masts
Designation Mast spigot: da (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
* luminaire color Siteco® metallic gray (DB 702S) as standard | for luminaire color black (RAL 9005), please replace number “8” at the
end of the order number with “1” (further RAL and DB colors on request)
a1 a2
200
c
da da
a1 a2 c
SMALL BELL: 5NY157… 445 445 829
LARGE BELL 5NY156… 595 595 1040 2.170
2 Town and park luminaires | Mast and catenary luminaires
Mast mounting element with ball element | fixing to mast via internal expanding clamp
without visible screws | steel, galvanized and coated, Siteco ® metallic gray (DB 702S)* |
suitable for conical and cylindrical masts
Designation Mast spigot: da (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
* luminaire color Siteco® metallic gray (DB 702S) as standard | for luminaire color black (RAL 9005), please replace number “8” at the
end of the order number with “1”; for light gray (RAL 7035), use number “5”. Corresponding OSRAM order number on request.
a1 a2
c
b
a1 a2 b c
SMALL BELL: 5NY157… 360 460 436 829
LARGE BELL 5NY156… 500 610 500 1040
2.171
Town and park luminaires | Mast and catenary luminaires 2
Mast mounting element with ball element | fixing to mast via grub screws below ball;
guidance via tube supports entering into mast | steel, galvanized and coated, Siteco®
metallic gray (DB 702S)* | suitable for conical and cylindrical masts
Designation Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
* luminaire color Siteco® metallic gray (DB 702S) as standard | for luminaire color black (RAL 9005), please replace number “8” at the
end of the order number with “1”; for light gray (RAL 7035), use number “5”. Corresponding OSRAM order number on request.
360 500
725
850
450
4 65
115
3xM10. 120°
200
3xM10. 120°
da
da
Wall arm
Designation No. of brackets Wt. (kg) Order no. OSRAM Order no. Siteco
* luminaire color Siteco® metallic gray (DB 702S) as standard | for luminaire color black (RAL 9005), please replace number “8” at the
end of the order number with “1”; for light gray (RAL 7035), use number “5”. Corresponding OSRAM order number on request.
610 820
829
ø9
430
1040
93
ø42
500
120
ø11
ø203
ø60
ø272
93
120
For detailed information about intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires, see Chapter 6 are specified in Chapter 7
2.172
2 Town and park luminaires | Mast and catenary luminaires
Optical cover
Designation Inner diameter di Wt. (kg) Order no. OSRAM Order no. Siteco
2.173
Town and park luminaires | Mast and catenary luminaires 2
2.174
2 Town and park luminaires | Secondary refl ector luminaires
SWDISC®
The SWDISC® luminaires with Siteco Mirrortec® system are Characteristic of the Siteco Mirrortec® SWDISC® luminaire is
based upon the principle of secondary reflection. With this the light, floating appearance of the projector head and
special lighting technology, a lumen package from a projec- circular luminaire canopy. This serves as a supporting
tor is emitted to a deflection reflector, is then split into many element for the integrated 3D faceted reflector that accord-
brilliant light points by this and is precisely cast onto the ing to specification creates either symmetric or asymmetric
area to be illuminated. The reflector facets effect highly effi- light distribution. With the SWDISC ® 1 version, projector and
cient light point resolution to create glare-free, harmonious canopy reflector are fixed to the mast with straight connec-
light distribution. tion elements.
Features Electrics
— glare-free lighting with optimized light output ratio via Luminaire with pre-assembled 6m cable for connection of
innovative Siteco Mirrortec® secondary reflector luminaire in mast terminal box | projector module with
technology with efficient secondary reflector and bayonet catch, accessible without tools for maintenance
extremely narrow beam primary reflector purposes and relamping
— handcrafted mast connection
— optimized light distribution for illuminating town squares Housing
and for street lighting Mast and support arms of steel; canopy of aluminum with
— tool-free relamping via bayonet catch for simple opening integrated secondary reflector; projector housing of glass-fi-
of lamp compartment ber-reinforced polyester; all parts with weather-resistant
— extremely weather-resistant coating coating in Siteco® metallic gray (DB 702S) | projector with
flat cover of toughened safety glass | mast included in scope
Lighting technology of supply | insulation class: II | protection rating: IP65
reflector system with primary and secondary reflector for
system-optimized, symmetric or asymmetric light distribu- Applications
tion | for glare-free, uniform illumination — plazas
— town centers
— parks
2.175
Town and park luminaires | Secondary refl ector luminaires 2
980
ø76 ø730
910
5670
lph
615
1650
400
600
Aw=0,14 m²
800
ø133
symmetric distribution
1x HIT-CE 70W G12 25.0 4039806378866 5NA266E1MS0A108
1x HIT-CE 150W G12 27.0 4039806378880 5NA266E1PS0A108
— weight specifi cation: weight of secondary refl ector unit and supporting elements; weight of mast: approx. 60kg
Mounting
Lichtpunkthöhe 6 mheight
Neigung 0° 6m Tilt 0°
2.176
2 Town and park luminaires | Secondary refl ector luminaires
GALAXSiE
The GALAXSiE luminaires with Siteco Mirrortec ® system are Characteristic for GALAXSiE is the purist construction of the
based upon the principle of secondary reflection. With this matched unit of projector head and circular luminaire
special lighting technology, a lumen package from a projec- canopy. This serves as a supporting element for the inte-
tor is emitted to a deflection reflector, is then split into many grated 3D faceted reflector that according to specification
brilliant light points by this and precisely cast onto the area creates either symmetric or asymmetric light distribution.
to be illuminated. The reflector facets effect highly efficient
light point resolution to create glare-free, harmonious light
distribution.
Features Electrics
— glare-free lighting with optimized light output ratio via Luminaire with pre-assembled 6m cable for connection of
innovative Siteco Mirrortec® secondary reflector technol- luminaire in mast terminal box | projector module with bayo-
ogy with efficient secondary reflector and extremely net catch, accessible without tools for maintenance purpos-
narrow beam primary reflector es and relamping
— optimized light distribution for illuminating town squares
and for street lighting Housing
— highly efficient optics for wide luminaire spacing with Diecast aluminum mast mounting element; canopy of alu-
highly uniform illuminance minum with integrated secondary reflector; projector housing
— luminaire for standard mast with mast spigot 76mm; of glass-fiber-reinforced polyester; all parts with weather-resis-
therefore ideally suited for refurbishments tant coating in Siteco® metallic gray (DB 702S); metallic gray
— tool-free relamping via bayonet catch for simple opening (RAL 9006) canopy underside acts as a supplementary
of lamp compartment reflector surface | supporting elements of V4A | projector with
— extremely weather-resistant coating flat cover of toughened safety glass | insulation class: II |
— robust, diecast aluminum mast mounting element protection rating: IP65
— including assembled 6m connection cable
Applications
Lighting technology — plazas
Reflector system with primary and secondary reflector for — town centers
system-optimized, symmetric or asymmetric light distribution — parks
| for glare-free, uniform illumination — residential areas
2.177
Town and park luminaires | Secondary refl ector luminaires 2
ø 800
1075
525
Aw=0,14 m²
GALAXSiE
1$(0$
[+,7 &(:FIOP
Mast luminaire for post-top mounting (DB 702S); supporting elements of
— with Siteco Mirrortec® technology; with stainless steel; projector with toughened
round canopy with integrated reflector, safety glass cover
symmetric or asymmetric wide distribution — type of protection: IP65
— projector with CCG, with parallel p.f. — insulation class: II
correction — mast spigot: da = 76 x 100mm
— projector housing of glass-fiber-rein- (with reducer: da = 60mm)
forced polyester, canopy and mast — recommended mounting height:
mounting element of aluminum, all parts LPH = 4…6m
coated in Siteco® metallic gray — luminaire includes pre-installed
FGNOP connection cable
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
asymmetric distribution
1x HIT-CE 70 W G12 13.1 CCG 4039806248558 5NA314E1MA08
1x HIT-CE 150 W G12 13.0 CCG 4039806248596 5NA314E1PA08
symmetric distribution
1x HIT-CE 70 W G12 13.6 CCG 4039806248572 5NA314E1MS08
1x HIT-CE 150 W G12 13.5 CCG 4039806248619 5NA314E1PS08
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
2.178
2 Town and park luminaires | Secondary refl ector luminaires
for mounting the luminaire to masts with spigot size da = 60mm | reducer of diecast aluminum
da Mounting information
For detailed information about intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires, see Chapter 6 are specified in Chapter 7
2.179
Town and park luminaires | Secondary refl ector luminaires 2
2.180
2 Town and park luminaires | Heritage luminaires
TEKTUS
The luminaires of the TEKTUS family unite modern lighting a manufactory. The installation-friendly, modularly designed
technology with a classic appearance and exclusive materi- TEKTUS is available in two construction sizes (MIDI/MAXI)
als. Their form is reminiscent of historical examples, but in- and can be combined with a semi-spherical enclosure of
terpreted with a modern appeal. In this way, TEKTUS lumi- PMMA, transparent or stippled. When equipped with a
naires during the day are able to blend outstandingly with pagoda reflector, zonal, rotationally symmetrical light
historical urban architecture, but are also successful as part distribution is emitted. Optional shielding on the building
of modern city ensembles. side reduces light spill to the facade.
Features Electrics
— uniform appearance under different deployment Electrical insert as complete unit including all electrical com-
conditions with two construction sizes with identical design ponents and accommodation of reflectors | luminaire insert
— high-quality workmanship thanks to handcrafting with 2-pole connection terminal (version with reducing cir-
— luminaire housing and supporting elements of cuit: 2-pole + 1-pole for 230V control wire), max. 2.5mm² |
weather-resistant bronze power reduction: USt = 230V → 100% luminous flux; USt = 0V
— application-adapted day and night-time effect via various → 50% luminous flux (with start in power reduction mode:
luminaire covers 100% mode initially for approx. 6min.)
— tool-free opening of lamp compartment via bayonet catch
for simple relamping Housing
— also available with multiple arrangement or as wall Insulation class: II | protection rating: IP44 | luminaire
luminaire housing and supporting elements of bronze | natural bronze
surface, dark burnished | formally matched design masts |
Lighting technology PMMA luminaire cover
Optical versions via combinations of cover and reflector
insert: open distribution or rotationally symmetric wide Applications
distribution, also with shielding on building side | transparent — plazas
or stippled optical enclosure — town centers
— parks
— residential areas
2.181
Town and park luminaires | Heritage luminaires 2
760
241
638
ø280
ø500
Aw=0,14 m²
Mast luminaire for post-top mounting via — luminaire housing and support elements
integrated support bracket of bronze, dark burnished; cover of
— open distribution, with transparent or PMMA
stippled cover; asymmetric wide distribu- — type of protection: IP44
tion (with reduced light emission into the — insulation class: II
rear area) via pagoda reflector; pagoda — recommended mounting height:
reflector with light distribution directed LPH = 3…4.5m
downwards — suitable for design mast; mast
— with CCG, with parallel p.f. correction connection for twin arrangement or wall
FGNOP bracket on request
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1 Light source Order no. Order no.
OSRAM Siteco
Stippled
1x HSE 50 W 1) E27 25.3 CCG with thermal protection 4039806317582 5NA264E1MF26
Transparent
1x HSE 50 W 1) E27 25.4 CCG with thermal protection 4039806317575 5NA264E1MF16
P
2.182
2 Town and park luminaires | Heritage luminaires
810
254
655
390
710
Aw=0,16 m²
Mast luminaire for post-top mounting via — luminaire housing and support elements
integrated support bracket of bronze, dark burnished; cover of
— open distribution, with transparent or PMMA
stippled cover; symmetric wide distribu- — type of protection: IP44
tion or asymmetric wide distribution (with — insulation class: II
reduced light emission into the rear area) — recommended mounting height:
via pagoda reflector; pagoda reflector LPH = 4…6m
with light distribution directed downwards — suitable for design mast; mast
— with CCG, power-factor-corrected, de- connection for twin arrangement or wall
FGNOP pending on version with power reduction bracket on request
via 230V control voltage or with ECG
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
Stippled
1x HSE 50 W 1) E27 28.4 CCG with thermal protection 4039806317322 5NA263E1MA26
1x HSE 70 W E27 X 28.6 CCG with thermal protection 4039806317360 5NA263E1MB26
transparent
1x HSE 50 W 1) E27 28.6 CCG with thermal protection 4039806317315 5NA263E1MA16
1x HSE 70 W E27 X 28.7 CCG with thermal protection 4039806317346 5NA263E1MB16
P
2.183
Town and park luminaires | Heritage luminaires 2
Luminaire, supporting elements and mast mounting element with TEKTUS form one unit |
luminaires with brackets for multiple arrangements are available on request
a2
Luminaire, supporting elements and mast mounting element with TEKTUS form one unit |
luminaires with brackets for wall mounting are available on request
a1
h
2.184
2 Town and park luminaires | Heritage luminaires
Design mast
with offset spigot for flush-fitting connection of mast to mast mounting element of the
luminaire | cylindrically offset mast | steel, galvanized and powder-coated in bronze
Designation h1 (m) LPH (m) Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
400
600
2.185
Town and park luminaires | Heritage luminaires 2
Pagoda reflector
for high-pressure lamp (1x HSE 50/70W) | for TEKTUS MIDI: asymmetric distribution |
for TEKTUS MAXI: symmetric or asymmetric distribution
Designation Type Wt. (kg) Order no. OSRAM Order no. Siteco
[+6(:φOP [+6(:φOP
/LFKWVWÁUNHNODVVHQDFK /LFKWVWÁUNHNODVVHQDFK
(1* (1*
2.186
2 Town and park luminaires | Heritage luminaires
Optical cover
Designation Inner diameter di Wt. (kg) Order no. OSRAM Order no. Siteco
2.187
Town and park luminaires | Heritage luminaires 2
2.188
3 Road luminaires | Overview
21m
18m
15m
12m
9m
6m
3m
SQ 200 SQ 100 SQ 50 LED | Page 3.21 SR 200 SR 100 SR 50 LED | Page 3.27
Page 3.45 Page 3.45 SQ 50 | Page 3.45 Page 3.59 Page 3.59 SR 50 | Page 3.59
3.1
Road luminaires | Overview 3
21m
18m
15m
12m
9m
6m
3m
Streetlight 10 micro LED | Page 3.9 ST 50 | Page 3.79 SiCOMPACT® A2 MINI LED | Page 3.33 SiSTELLAR ® MAXI
Streetlight 10 mini LED | Page 3.9 ST 100 | Page 3.79 SiCOMPACT® A2 MIDI LED | Page 3.33 Page 3.91
Streetlight 10 midi LED | Page 3.9 SiCOMPACT® A2 MIDI | Page 3.85
3.2
3 Road luminaires | Overview
3.3
Road luminaires | Overview 3
Mast luminaires
Page 3.45 Page 3.45 Page 3.45 Page 3.59 Page 3.59 Page 3.59 Page 3.79 Page 3.79
SiCOMPACT® SiSTELLAR ®
A2 MIDI MAXI
Page 3.85 Page 3.91
3.4
3 Road luminaires | Product search
Insulation class II II II II II II
Recommended mounting height (m) 3.5…5 4…6 6…10 4…6 4…6 3…6
Recommended applications
— urban areas
— pedestrian crossings ¢
— cycle paths ¢ ¢
— crossing areas | wide-area lighting ¢ ¢ ¢
— parking spaces ¢ ¢ ¢ ¢ ¢ ¢
— multi-lane roads | motorways ¢
— main thoroughfares ¢ ¢
— through-roads and collection roads ¢ ¢ ¢ ¢
— residential streets | side streets ¢ ¢ ¢ ¢ ¢
— facade lighting ¢
Installation method
— post-top mounting ¢ ¢ ¢ ¢ ¢ ¢
— side-entry mounting | ¢ ¢ ¢ ¢ ¢
wall outlet (pipe connection)
— cross arm | supporting structure ¢
— platform | ground mounting
— wall surface mounting ¢
— ceiling surface mounting
Lighting technology
— asym. extremely wide distribution ¢
— asym. wide distribution ¢ ¢ ¢ ¢ ¢ ¢
— asym. right | left distribution ¢
— variably adjustable reflector
— shielding on building side
— shielding on street side
3.5
Road luminaires | Product search 3
SiCOMPACT®
A2 MIDI LED
IP66
6…10
¢
¢
0% 0°
3.6
3 Road luminaires | Product search
Mast luminaires
Light source
— HIT-CE/HIT-CE S-od/ HIT-CE-od ¢/¢/- ¢ ¢/-/- ¢/-/-
— HIE-CE/HIE-CE-P -/¢ -/¢
— TE-LEL/TC-TEL ¢/-
— HST/HSE ¢/¢ ¢/¢ ¢/¢ ¢/- ¢/¢
Insulation class II II II II I | II
Recommended mounting height (m) 4…6 | 6…10 | 8…12 4…6 | 6…10 | 8…12 4…6 | 6…10 6…10 10…16
Recommended applications
— urban areas
— pedestrian crossings ¢ ¢ ¢
— cycle paths ¢ ¢
— crossing areas | wide-area lighting ¢ ¢ ¢ ¢ ¢
— parking spaces ¢ ¢ ¢ ¢ ¢
— multi-lane roads | motorways ¢ ¢ ¢ ¢ ¢
— main thoroughfares ¢ ¢ ¢ ¢ ¢
— through-roads and collection roads ¢ ¢ ¢ ¢
— residential streets | side streets ¢ ¢ ¢ ¢
— facade lighting
Installation method
— post-top mounting ¢ ¢ ¢ ¢ ¢
— side-entry mounting | ¢ ¢ ¢
wall outlet (pipe connection)
— cross arm | supporting structure
— platform | ground mounting
— wall surface mounting ¢
— ceiling surface mounting
Lighting technology
— asym. extremely wide distribution ¢
— asym. wide distribution ¢ ¢ ¢ ¢ ¢
— asym. right | left distribution ¢ ¢
— variably adjustable reflector ¢ ¢ ¢
— shielding on building side ¢ ¢
— shielding on street side ¢ ¢
3.7
Road luminaires | Product search 3
3.8
3 Road luminaires | Mast luminaires
Streetlight 10 LED
The Streetlight 10 LED sets standards for outdoor LED The microprocessor-controlled LED operating electronics
luminaires developed completely for efficiency and light make available a high level of efficiency potential. Luminous
effects. A purist, functional design is combined with high- flux can be individually set according to needs with the
power LEDs and outstanding lighting technology. As such, performance packages “Plus” (with Siteco® Service Box)
the Streetlight 10 LED eminently complies with the require- and “Premium” (with Street Light Control).
ments of DIN EN 13201 for all S and M lighting classes. The
Streetlight 10 LED is available in three construction sizes: The mechanical concept of the luminaire is also future-fit.
micro, mini and midi, each with one or two LED modules. Both the optical module and the gear tray can be simply and
In addition to the highly precise road optics used in both rapidly replaced. This means upgrading to future, higher-
construction sizes, there is also an optical module for the performance, LED modules is easily implemented. This
lighting of cycle paths (mini) and a solution for pedestrian solution enables a sustainable and future-oriented use of
crossings (midi). the high-quality luminaire housing.
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
3.9
Road luminaires | Mast luminaires 3
3.10
3 Road luminaires | Mast luminaires
0% 0°
481 177
46
231
Aw=0,04 m²
10
— please order the 'mast cable set' separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast fl ange according to spigot diameter separately
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
0% 0°
619 170
45
137
Aw=0,07 m²
10
— please order the 'mast cable set' separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast fl ange according to spigot diameter separately
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
Mandatory accessories (for details see page 3.19 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Mast flange, spigot size: 42mm 0.4 4050737115726 5XA59000XM4
P
Mast flange, spigot size: 60mm 0.5 4050737115702 5XA59000XM2
Mast flange, spigot size: 76mm 0.6 4050737101484 5XA59000XM1
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.9 4050737028828 5EA6Y00L03
Mast cable set, L = 6m, for “Plus” version 0.9 4050737056098 5EA6Y00L08
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
3 Road luminaires | Mast luminaires
0% 0°
619 170
45
137
Aw=0,1 m²
10
— please order the 'mast cable set' separately for confi guration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
— please order mast fl ange according to spigot diameter separately
P
3.13
Road luminaires | Mast luminaires 3
3.14
3 Road luminaires | Mast luminaires
0% 0°
800 386
68
168
Aw=0,07 m²
10
— please order the 'mast cable set' separately for confi guration of the “Plus” version with installed luminaire
Mounting height 8m
0RXQWLQJKHLJKWP7LOW
Tilt 0°
O[
— please order SLC light management components for the “Premium” version separately if required
— please order mast fl ange according to spigot diameter separately
P
3.15
Road luminaires | Mast luminaires 3
3.16
3 Road luminaires | Mast luminaires
0% 0°
800 386
68
168
Aw=0,07 m²
10
3.17
Road luminaires | Mast luminaires 3
3.18
3 Road luminaires | Mast luminaires
For parameterizing the operating electronics of all “Plus” version Siteco® LED road
luminaires | maximum energy efficiency via individual adaptation of lighting level, switching
time and reduction level | setting of static colors and dynamic color sequences with suitable
luminaires | software* included with Service Box | with plug-in coupling for connecting
Y-cable | plastic housing; plug-in coupling with protection cap IP54 | insulation class II
— incl. Y-cable for looping the Service Box into luminaire supply cable | incl. 'workshop' cable set for parameterizing the
unmounted luminaire in the workshop; safety plug at one end
* adoption of complete color sequences and software updates possible via PC | incl. mini USB interface for connection to PC
For wiring of junction box in mast to the luminaire, with “Plus” version | with 5-pole plug
coupling for integrating Siteco® Service Box for manual luminaire configuration (e.g. lumino-
us flux, timer etc.)
Detailed information for intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires: chapter 6 are specified in chapter 7
3.19
Road luminaires | Mast luminaires 3
Mast flange
For installing Streetlight 10 LED as post-top or side-entry luminaire via twisting of mast
flange | luminaire inclination set via mast flange (0°, 5°, 10°, 15°) | various mast flanges for
differing mast spigot diameters | mast flange of diecast aluminum, light gray (RAL 7035)
Streetlight 10 midi
Mast flange, spigot size: 42mm 4050737035482 5XA58100XM4
Mast flange, spigot size: 60mm 4050737035468 5XA58100XM2
Mast flange, spigot size: 76mm 4050737035444 5XA58100XM1
— mast fl ange not included in luminaire delivery; please order mast fl ange separately according to mast spigot diameter
Mast spigot: da x l = 76 x 100mm (luminaire mounting possible with mast flange type 76)
da x l = 60 x 100mm (luminaire mounting possible with mast flange type 60)
Mast spigot: da x l = 60 x 100mm (luminaire mounting possible with mast flange type 60)
da x l = 42 x 100mm (luminaire mounting possible with mast flange type 42)
Detailed information for intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires: chapter 6 are specified in chapter 7
3.20
3 Road luminaires | Mast luminaires
SQ 50 LED
The SQ 50 LED road luminaire has been designed to The LED luminaire can be individually set according to
modernize existing installations with high energy efficiency needs via the microprocessor-controlled LED operating
and to supply standard-compliant lighting for new instal- electronics with the performance packages “Plus” (with
lations. The familiar, contemporary and functional housing Siteco® Service Box) and “Premium” (with Street Light
accommodates a gear tray with state-of-the-art LED Control).
technology and precisely matched optical systems.
Thanks to the Siteco® gear tray technology, the LED module
This principle ensures that with the supplementing of exis- of the SQ 50 LED luminaires is replaceable, and an upgrade
ting systems with efficient SQ 50 LED light points, the har- to future, higher-performance LED modules is thus easily
monious overall appearance of the installation is maintained. implemented.
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
3.21
Road luminaires | Mast luminaires 3
3.22
3 Road luminaires | Mast luminaires
0%
568 444
189
Aw=0,084 m²
SQ 50 LED
;$$1$*
for post-top or side-entry mounting | asymmetric distribution
[/('.&5,ƁI1OP
Mast luminaire for universal post-top or aluminum canopy (RAL 9007); cover
side-entry mounting of toughened safety glass (TSG)
— with white LEDs with lens, asymmetric — type of protection: IP66
wide distribution; with flat, structured and — insulation class: II
reflection-reduced white glass cover — mast spigot with post-top mounting:
— microprocessor-controlled LED operating da = 60/76 x 100mm
electronics; depending on version with — mast spigot with side-entry mounting:
differing control function for light da = 42/60 x 120mm
management and monitoring — recommended mounting height:
FGNOP — housing of diecast aluminum; metallic LPH = 4…6m
gray aluminum frame (RAL 9006), gray
& &
Control function for light management and monitoring:
/XPLQRXVLQWHQVLW\FODVV • all versions: with temperature monitoring for protection of LEDs from thermal overload, additionally with
DFFRUGLQJWR • “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
(1* • “Plus” version: with luminous flux constancy over complete service life | with integrated, programmable timer for luminous flux
reduction at two levels | alternatively: luminous flux reduction via 230V control voltage
• “Premium” version: functional range as with “Plus” version, but for individual monitoring and control of the luminaire from a central
control point via LON PowerLine
Accessories (for details see page 3.24 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Mast cable set, L = 4m, for “Plus” version 0.7 4050737028804 5EA6Y00L02
Mast cable set, L = 5m, for “Plus” version 0.7 4050737028828 5EA6Y00L03
Mast cable set, L = 6m, for “Plus” version 0.9 4050737056098 5EA6Y00L08
Siteco Service Box, for “Plus” version 1.7 4039806998927 5EA6TEF01
P
3.23
Road luminaires | Mast luminaires 3
For parameterizing the operating electronics of all “Plus” version Siteco® LED road
luminaires | maximum energy efficiency via individual adaptation of lighting level, switching
time and reduction level | setting of static colors and dynamic color sequences with suitable
luminaires | software* included with Service Box | with plug-in coupling for connecting
Y-cable | plastic housing; plug-in coupling with protection cap IP54 | insulation class II
— incl. Y-cable for looping the Service Box into luminaire supply cable | incl. 'workshop' cable set for parameterizing the
unmounted luminaire in the workshop; safety plug at one end
* adoption of complete color sequences and software updates possible via PC | incl. mini USB interface for connection to PC
For wiring of junction box in mast to the luminaire, with “Plus” version | with 5-pole plug
coupling for integrating Siteco® Service Box for manual luminaire configuration (e.g. lumino-
us flux, timer etc.)
Detailed information for intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires: chapter 6 are specified in chapter 7
3.24
3 Road luminaires | Mast luminaires
l
Mounting information for side-entry mounting
da
da x l = 42 x 135mm
l
* mast diameter with stepped offset mast : dM ≤ 7600
Detailed information for intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires: chapter 6 are specified in chapter 7
3.25
Road luminaires | Mast luminaires 3
3.26
3 Road luminaires | Mast luminaires
SR 50 LED
The SR 50 LED with its functional and classic road luminaire The luminaires of the SR family are suitable for a wide variety
design is especially suitable for the expansion of existing of tasks in technical road lighting. Equipped with state-
systems with efficient LED technology. Systems can be de- of-the-art lighting technology and precise optics, they offer
signed with wide luminaire spacing in compliance with DIN outstanding solutions in relation to energy efficiency, lumi-
EN 13201. The microprocessor-controlled LED operating naire spacing and service life. Despite their robust construc-
electronics enable further savings. The luminous flux of the tion and high protection rating (IP65), the SR luminaires are
luminaire can be individually set according to needs with the easy to handle: a central rotary catch on the luminaire under-
performance packages “Plus” (with Siteco® Service Box) side secures the optical enclosure. The optical enclosure
and “Premium” (with Street Light Control). can be opened downwards by rotating the catch through
180 degrees. Thanks to the Siteco® gear tray technology,
the LED module of the new SR 50 LED luminaires is replace-
able, and an upgrade to future, higher-performance LED
modules is thus easily implemented.
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
3.27
Road luminaires | Mast luminaires 3
3.28
3 Road luminaires | Mast luminaires
0% 0°
606 288
178
197
Aw=0,10 m²
SR 50 LED
;$$1$
for post-top or side-entry mounting | asymmetric distribution
[/('.&5,ƁI1OP
P
3.29
Road luminaires | Mast luminaires 3
3.30
3 Road luminaires | Mast luminaires
For parameterizing the operating electronics of all “Plus” version Siteco® LED road
luminaires | maximum energy efficiency via individual adaptation of lighting level, switching
time and reduction level | setting of static colors and dynamic color sequences with suitable
luminaires | software* included with Service Box | with plug-in coupling for connecting
Y-cable | plastic housing; plug-in coupling with protection cap IP54 | insulation class II
— incl. Y-cable for looping the Service Box into luminaire supply cable | incl. 'workshop' cable set for parameterizing the
unmounted luminaire in the workshop; safety plug at one end
* adoption of complete color sequences and software updates possible via PC | incl. mini USB interface for connection to PC
For wiring of junction box in mast to the luminaire, with “Plus” version | with 5-pole plug
coupling for integrating Siteco® Service Box for manual luminaire configuration (e.g. lumino-
us flux, timer etc.)
3.31
Road luminaires | Mast luminaires 3
Mast flange
For installing SR luminaire as post-top or side-entry luminaire via twisting of mast flange |
luminaire inclination set via mast flange (0°, 3°, 8°, 15°) | various mast flanges for differing
mast spigot diameters | mast flange of diecast aluminum, light gray (RAL 7035)
— mast fl ange not included in luminaire delivery; please order mast fl ange separately according to mast spigot diameter
Typ 76 Typ 60
da
l
Detailed information for intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires: chapter 6 are specified in chapter 7
3.32
3 Road luminaires | Mast luminaires
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
3.33
Road luminaires | Mast luminaires 3
Electrics Applications
Luminaire wired ready for connection | cable entry for cables — town square, road and path lighting
D = 6…12mm — general wide-area lighting and building illumination
— security lighting for industrial facilities
SiCOMPACT® A2 MINI LED: (insulation class II) with 3-pole — in indoor areas: can also be used as uplight
connection terminal, max. 2.5mm² (2-pole for mains supply — for large light-point spacing of 25…32m
+ 1-pole for 230V control voltage for power reduction) |
cable entry for cables D = 6…12mm
3.34
3 Road luminaires | Mast luminaires
687
355
250
40
0% 0°
444
95
Aw=0,03 m²
189
SiCOMPACT® A2 MINI LED
;$/1$
1<;$ for mast bracket, fixing at rear
[/('.&5,ƁI1OP
Luminaire for mounting to mast via mast — housing with rear fixing of diecast
bracket aluminum, Siteco® metallic gray (DB
— with white LEDs with lens, asymmetric 702S); cover of toughened safety glass
wide distribution; with flat, structured — type of protection: IP66
cover — insulation class: II
— microprocessor-controlled LED operating — recommended mounting height:
electronics LPH = 3…6m
Control function for light management and monitoring:
• all versions: with temperature monitoring for protection of LEDs from thermal overload, additionally with
FGNOP • “Basic” version: with luminous flux reduction via 230V control voltage | no luminous flux constancy
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
LED 5000 > 80 2180 41 4.3 Basic 4050737012766 5XA7577LNA208
Mounting height 4m
0RXQWLQJKHLJKWP7LOW
Tilt 0°
O[
P
3.35
Road luminaires | Mast luminaires 3
355
198
250
0% 0°
88
95
409
Aw=0,03 m²
Control function for light management and monitoring:
• LED module, “Basic”: with temperature monitoring for protection of LEDs from thermal overload | with power reduction via 230V
FGNOP control voltage
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
LED 5000 > 80 2180 41 4.3 Basic 4050737012766 5XA7577LNA208
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.36
3 Road luminaires | Mast luminaires
40
0% 0°
51 51
261
276
250
355
95
196
Aw=0,03 m²
Luminaire with mounting bracket for Siteco® metallic gray (DB 702S); cover
mounting to walls, ceilings or cross-arms of toughened safety glass
— with white LEDs with lens, asymmetric — type of protection: IP66
wide distribution; with flat, structured — insulation class: II
cover — adjustment range: 10…350°
— microprocessor-controlled LED operating (indoor installations: 0…360°)
electronics
— housing of diecast aluminum; bracket of
galvanized steel; housing and bracket in
FGNOP
Control function for light management and monitoring:
• LED module, “Basic”: with temperature monitoring for protection of LEDs from thermal overload | with power reduction via 230V
control voltage
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.37
Road luminaires | Mast luminaires 3
998
565
420
60
0% 0°
501
155
Aw=0,08 m²
246
SiCOMPACT® A2 MIDI LED
;$%17
1<;$ for mast bracket, fixing at rear
[/('.&5,ƁI1OP
Luminaire for mounting to mast via mast — housing with rear fixing of diecast
bracket aluminum, Siteco® metallic gray (DB
— with white LEDs with lens, asymmetric 702S); cover of toughened safety glass
wide distribution; with flat, structured — type of protection: IP66
cover — insulation class: I
— microprocessor-controlled LED operating — recommended mounting height:
electronics LPH = 6…10m
Mounting height 8m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.38
3 Road luminaires | Mast luminaires
565
420
0% 0°
155
153
Aw=0,08 m²
678
Mounting height 8m
0RXQWLQJKHLJKWP7LOW
Tilt 0°
O[
P
3.39
Road luminaires | Mast luminaires 3
565
0% 0°
102
230
465
420 155
348
Aw=0,08 m²
50
& &
/XPLQRXVLQWHQVLW\FODVV
Light source Order no. Order no.
DFFRUGLQJWR
(1* OSRAM Siteco
LED 5000 > 80 6600 98 15.3 ECG 4050737019666 5XA7587BNT008
Mounting height 6m
0RXQWLQJKHLJKWP7LOW
Tilt 0°
O[
P
3.40
3 Road luminaires | Mast luminaires
Mast mounting element with single or multiple bracket | galvanized steel, coated Siteco®
metallic gray (DB 702S) | with 5NY75701XA …: mast mounting element of aluminum
Designation Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
da Mounting information
Mast spigot: da x l
l
a1 a2 a3 a4
b
c
da da da da
3.41
Road luminaires | Mast luminaires 3
Mast mounting element multiple bracket | galvanized steel, coated Siteco® metallic gray
(DB 702S) | multiple bracket replaces the luminaire mounting bracket, luminaire connection
to the fixing points of the mounting bracket | adjustment of luminaire in 5° steps
Designation Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
da Mounting information
Mast spigot: da x l
l
a2 a3 a4
c
d2 d3 d4
3.42
3 Road luminaires | Mast luminaires
Wall adapter
Wall flange, cover and adapter of galvanized steel, coated in Siteco® metallic gray (DB 702S)
| wall flange via supplementary cover without visible screws
cover panel
for SiCOMPACT A2 MINI LED 4050737042442 5XA75700XG08
for SiCOMPACT A2 MIDI LED 4050737040134 5XA75800XG08
3.43
Road luminaires | Mast luminaires 3
3.44
3 Road luminaires | Mast luminaires
SQ luminaires
The SQ luminaires with three construction sizes (SQ 50, the right light. If the luminaire is equipped with a module for
SQ 100 and SQ 200) represent a flexible luminaire family for instant hot re-ignition then special security and monitoring
the technical road lighting sector. The three variants enable applications are possible.
the design of a uniform, overall road appearance with the
simultaneous solving of many varied lighting tasks. All SQ Despite their robust construction and high protection rating
luminaires feature high-quality workmanship with diecast (IP66), the SQ luminaires are easy to handle: by pulling the
aluminum and an elegant appearance. The functional lumi- lever catch the luminaire cover is opened upwards. The
naire form is designed to minimize the effects of wind. mechanism cuts off the power supply; maintenance and
Equipped with modern lighting technology and precise control work as well as gear tray replacement can be carried
optics, they offer outstanding solutions in relation to energy out without danger. The variability of the efficient radial
efficiency, luminaire spacing and light quality. Different opti- facetted reflector is also practical, with the reflector optimally
cal enclosures (flat/convex covers or diffusers) and various splitting the light point for wide asymmetric glare-free light.
lamp configurations illuminate a wide spectrum of roads with
3.45
Road luminaires | Mast luminaires 3
Features Housing
— high-quality, durable housing material of diecast aluminum Two-part luminaire housing consisting of frame and canopy
— three construction sizes for a wide spectrum of (can be opened upwards) | frame, mast clamping plate,
applications canopy and easy-access one-hand lever catch of diecast
— IP65 protection rating for lamp compartment and control aluminum with extremely weather-resistant coating: metallic
gear compartment gray aluminum frame (RAL 9006), gray aluminum canopy
— high-quality four-level sealing system with air-permeable (RAL 9007) | all-round bi-component EPDM sealing with
membrane for optimal pressure equalization labyrinth function | flat or convex luminaire cover of tough-
— flat cover panel for minimal glare and increased ened safety glass or diffuser of PMMA or PC | pivotable mast
protection against vandalism clamping plate flush-integrated in frame, for post-top and
— future-fit Vario gear tray technology side-entry mounting; 0° inclination with post-top mounting,
— individually settable optics via radial facetted reflector with offset mast spigot with side-entry mounting | pressure
(for T and E lamps) equalization system with air-permeable membrane for con-
— high luminaire light output ratios densation avoidance in the housing | insulation class: II |
— electrical unit replaced without tools protection rating: IP66 for complete luminaire
— convenient one-hand lever catch
— universal fixing system via pivotable mast clamping plate Applications
— luminaires with flat cover have low light immission;
Lighting technology especially suitable for immission-minimized lighting
Wide light distribution and high uniformity due to highly installations
efficient radial facetted optics | variable light-band deflection — SQ 50 suitable for residential areas, ancillary roads,
via adjustable optics | high level of system efficiency in watt residential streets and collection roads
ratings up to 400W with system-optimized light distribution — SQ 100 suitable for collecting roads, through-roads and
and wide luminaire spacing | optical enclosure is either flat main thoroughfares
cover panel of toughened safety glass for minimized light im- — SQ 200 suitable for main thoroughfares, expressways
mission, or transparent enclosure (PMMA), shielding on and motorways
house — SQ 100 and SQ 200 with special reflector unit for
or street side for luminaire with diffuser via optional supple- pedestrian crossings
mentary shield — SQ 50 and SQ 100 with extremely wide distribution
reflector unit for cycle paths
SQ 100 and SQ 200 with reflector unit for pedestrian
crossings, asymmetric left or right-sided distribution
Electrics
Canopy opened without tools, can be folded upwards; with
automatic all-pole power disconnection | tool-free relamping
| all electric components mounted on removable gear tray;
connection via plug-in coupling | luminaire wired ready for
connection with 2-pole terminal, max. 2.5mm² (version with
reducing circuit: 2-pole + 1-pole for 230V control wire, max.
1,5mm²) | optionally with efficient electronic control gear
(ECG) and Street Light Control (SLC) light management
components (SLC: central control and monitoring of intelli-
gent light points) or with CCG with parallel p.f. correction |
special versions also available with power-factor-corrected
CCG and ignition device for instant hot re-ignition | power
reduction: USt = 230V → 100% luminous flux;
USt = 0V → 50% luminous flux (with start in power reduction
mode: 100% mode initially for approx. 6min.)
3.46
3 Road luminaires | Mast luminaires
0%
568 444
189
Aw=0,084 m²
SQ 50
1$07*
with radial facetted optics | with flat cover panel | dimmable with ECG
[+67 0)://IOP
Mast luminaire for universal post-top or aluminum canopy (RAL 9007); cover
side-entry mounting of toughened safety glass (TSG)
— with radial facetted optics, asymmetric — type of protection: IP66
wide distribution; with flat cover — insulation class: II
— electronic control gear (ECG); according — mast spigot with post-top mounting:
to version either with interface for da = 60/76 x 100mm
dimming of luminaire (for external SLC — mast spigot with side-entry mounting:
luminaire controller in mast) or with SLC da = 42/60 x 120mm
luminaire controller (in luminaire) — recommended mounting height:
FGNOP — housing of diecast aluminum; metallic LPH = 4…6m
gray aluminum frame (RAL 9006), gray
— please order SLC luminaire controller and SLC light management components separately if required
P
3.47
Road luminaires | Mast luminaires 3
0%
568 444
189
Aw=0,084 m²
SQ 50
1$(07*
with radial facetted optics | with flat cover panel | with ECG or CCG
[+67 0)://IOP
Mast luminaire for universal post-top or aluminum canopy (RAL 9007); cover
side-entry mounting of toughened safety glass (TSG)
— with radial facetted optics, asymmetric — type of protection: IP66
wide distribution; with flat cover — insulation class: II
— with ECG or CCG, parallel p.f. corrected, — mast spigot with post-top mounting:
with power reduction according da = 60/76 x 100mm
to version — mast spigot with side-entry mounting:
— housing of diecast aluminum; metallic da = 42/60 x 120mm
gray aluminum frame (RAL 9006), gray — recommended mounting height:
FGNOP LPH = 4…6m
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
1x HST | HIT-CE/S-od 70 W 2) E27 9.8 CCG 4039806553737 5NA557E1MT0G
1x HST | HSE 50 W E27 9.6 CCG 4039806553607 5NA557E1JT0G
1x HST | HSE 70 W E27 X 10.0 CCG 4039806553829 5NA557E1MT1G
1x HST | HSE 150 W E40 X 11.3 CCG 4039806553904 5NA557E1PT1G
1x HST | HSE HIT-CE 100 W 1) E40 10.2 CCG 4039806553867 5NA557E1NT0G
1x HST | HSE HIT-CE 150 W 1) E40 11.3 CCG 4039806553881 5NA557E1PT0G
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is required
2) ballast with 2x power tapping 50/70W
Mounting height 6m
/LFKWSXQNWKÓKHP1HLJXQJ Tilt 0°
O[
P
3.48
3 Road luminaires | Mast luminaires
568 444
218
Aw=0,095 m²
SQ 50
1$(074
[+67 0)://IOP
with radial facetted optics | with convex cover | with CCG
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
1x HST HIT-CE/S-od 70 W 1) E27 8.8 CCG 4039806553744 5NA557E1MT0Q
1x HST HSE 70 W E27 X 10.0 CCG 4039806553836 5NA557E1MT1Q
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.49
Road luminaires | Mast luminaires 3
0%
688 467
191
Aw=0,11 m²
SQ 100
1$17&
with radial facetted optics | with flat cover panel | dimmable with ECG
[+67 0)://IOP
Mast luminaire for universal post-top or aluminum canopy (RAL 9007); cover
side-entry mounting of toughened safety glass (TSG)
— with radial facetted optics, asymmetric — type of protection: IP66
wide distribution; with flat cover — insulation class: II
— electronic control gear (ECG); according — mast spigot with post-top mounting:
to version either with interface for da = 60/76 x 100mm
dimming of luminaire (for external SLC — mast spigot with side-entry mounting:
luminaire controller in mast) or with SLC da = 42/60 x 120mm
luminaire controller (in luminaire) — recommended mounting height:
FGNOP — housing of diecast aluminum; metallic LPH = 6…10m
gray aluminum frame (RAL 9006), gray
— please order SLC luminaire controller and SLC light management components separately if required
— always observe socket position with use of HST/HSE lamps (see installation instructions)
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0° Accessories (for details see page 3.57 ff.)
O[
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Luminaire controller, LON PowerLine protocol, for installation in mast 0.6 4039806896414 5EA3CUE
Mounting bracket, for installation in mast or to mounting rail 0.2 4039806904263 5EA0Y00B01
P
3.50
3 Road luminaires | Mast luminaires
0%
688 467
191
Aw=0,11 m²
SQ 100
1$(17&
with radial facetted optics | with flat cover panel | with CCG
[+67 0)://IOP
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
1x HST 50 W 2) E27 12.1 CCG 4039806393296 5NA558E1MT0C236
1x HST 70 W E27 X 10.8 CCG 4039806397911 5NA558E1MT1C236
1x HST 100 W E40 X 12.8 CCG 4039806397973 5NA558E1NT1C236
1x HST 150 W E40 X 14.2 CCG 4039806398055 5NA558E1PT1C236
1x HST | HIT-CE 100 W 1) E40 12.7 CCG 4039806397959 5NA558E1NT0C236
1x HST | HIT-CE 150 W 1) E40 13.2 CCG 4039806398017 5NA558E1PT0C236
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is required
2) ballast with 2x power tapping 50/70W
— always observe socket position with use of HST/HSE lamps (see installation instructions)
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.51
Road luminaires | Mast luminaires 3
688 467
241
Aw=0,12 m²
SQ 100
1$(17& with radial facetted optics | with convex cover | with CCG
[+67 0)://IOP
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
1x HST | HSE | HIT-CE 100 W 1) E40 13.3 CCG 4039806429483 5NA558E1NT0C436
1x HST | HSE | HIT-CE 150 W 1) E40 14.0 CCG 4039806429506 5NA558E1PT0C436
1x HST | HSE 100 W E40 X 13.3 CCG 4039806429490 5NA558E1NT1C436
1x HST | HSE 150 W E40 X 12.6 CCG 4039806429544 5NA558E1PT1C436
1x HST | HSE 50 W2) E27 11.2 CCG 4039806418470 5NA558E1MT0C436
1x HST | HSE 70 W E27 X 13.0 CCG 4039806429476 5NA558E1MT1C436
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is required
2) ballast with 2x power tapping 50/70W
— HIT-CE-od lamps on request
Mounting height 8m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.52
3 Road luminaires | Mast luminaires
0%
688 467
191
Aw=0,11 m²
SQ 100
1$(35& single-sided asymmetric distribution, for pedestrian crossings | with flat cover panel |
[+67 0)://IOP
with CCG
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
asymmetric, left
1x HST | HIT-CE 150 W E40 14.7 CCG 4039806525925 5NA558E1PL0C236
asymmetric, right
1x HST | HIT-CE 150 W E40 14.7 CCG 4039806525949 5NA558E1PR0C236
— always observe socket position with use of HST/HSE lamps (see installation instructions)
0RXQWLQJKHLJKWP7LOW
O[
P
3.53
Road luminaires | Mast luminaires 3
0%
845 490
198
Aw=0,15 m²
SQ 200
1$37& with radial facetted optics | with flat cover panel | dimmable with ECG
[+67 0)://IOP
— please order SLC luminaire controller and SLC light management components separately if required
Mounting height 8m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.54
3 Road luminaires | Mast luminaires
0%
845 490
198
Aw=0,15 m²
SQ 200
1$(67&
with radial facetted optics | with flat cover panel | with CCG
[+67 0)://IOP
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
1x HST 150 W E40 X 16.3 CCG 4039806249883 5NA559E1PT1C236
1x HST 250 W E40 X 16.1 CCG 4039806249999 5NA559E1ST1C236
1x HST 400 W E40 18.6 CCG 4039806250001 5NA559E1TT0C236
1x HST 400 W E40 X 19.2 CCG 4039806250018 5NA559E1TT1C236
2x HST 50 W 2) E27 15.2 CCG 4039806251442 5NA559E2MT0C236
1x HST | HIT-CE 150 W 1) E40 17.0 CCG 4039806249869 5NA559E1PT0C236
1x HST | HIT-CE 250 W E40 16.0 CCG 4039806249968 5NA559E1ST0C236
2x HST | HIT-CE 100 W 1) E40 17.6 CCG 4039806251466 5NA559E2NT0C236
1x HSE 150 W E40 16.0 CCG 4039806249814 5NA559E1PE0C236
1x HSE 150 W E40 X 16.5 CCG 4039806249838 5NA559E1PE1C236
1x HSE 250 W E40 17.5 CCG 4039806249906 5NA559E1SE0C236
1x HSE 250 W E40 X 17.5 CCG 4039806249920 5NA559E1SE1C236
1x HSE 400 W E40 18.8 CCG 4039806251374 5NA559E1TE0C236
1x HSE 400 W E40 X 19.3 CCG 4039806251381 5NA559E1TE1C236
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is required
2) ballast with 2x power tapping 50/70W
Mounting height 12m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.55
Road luminaires | Mast luminaires 3
845 490
312
Aw=0,20 m²
SQ 200
1$(75&
single-sided asymmetric distribution, for pedestrian crossings | with diffuser |
[+67 0)://IOP
with CCG
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
asymmetric, left, diffuser, PC, with CCG with thermal protection, pf-corrected
1x HST 400 W E40 845 490 18.7 CCG 4039806454485 5NA559E1TL0C336
asymmetric, right, diffuser, PC, with CCG with thermal protection, pf-corrected
1x HST 400 W E40 845 490 18.7 CCG 4039806454508 5NA559E1TR0C336
Mounting height 14m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.56
3 Road luminaires | Mast luminaires
Supplementary shield
For luminaires with plastic diffuser (PMMA or PC) | shielding on building side or road side |
inner mounting
Socket adapter
For use of HIT-CE-P with E27 base in luminaires with E40 socket
da x l = 48 x 120mm
dM
da x l = 42 x 135mm
l * mast diameter with stepped offset mast: dM ≤ 7600
Detailed information for intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires: chapter 6 are specified in chapter 7
3.57
Road luminaires | Mast luminaires 3
Convex cover
Diffuser
PMMA or PC
PMMA
for SQ 50 0.5 4039806553416 5NA55700XW
for SQ 100 0.6 4039806400727 5NA55800XW
for SQ 200 0.7 4039806253743 5NA55900XW
PC
for SQ 50 0.5 4039806553423 5NA55710XW
for SQ 100 0.6 4039806400864 5NA55810XW
for SQ 200 0.7 4039806374080 5NA55910XW
Detailed information for intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires: chapter 6 are specified in chapter 7
3.58
3 Road luminaires | Mast luminaires
SR luminaires
The modern luminaires of the SR family are suitable for a Despite their robust construction and high protection rating
wide variety of tasks in technical road lighting. Equipped (IP65), the SR luminaires are easy to handle: a central rotary
with modern lighting technology and precise optics, they catch on the luminaire underside secures the lamp cover
offer outstanding solutions in relation to energy efficiency, and gear tray. The lamp cover can be opened downwards
luminaire spacing and service life. Three construction sizes, by rotating the catch through 180 degrees. A further setting
two optical enclosures (flat cover panel, convex diffuser) and unlocks the gear tray with lamp socket and lamp that can
various lamp configurations for differing light distribution also be hinged downwards. The mechanism cuts off the
characteristics and light output ratios are available. If the power supply; maintenance and control work as well as
luminaire is equipped with a module for instant hot re- tool-free gear tray replacement can be carried out without
ignition then special security and monitoring applications danger. The maintenance of the efficient radial facetted
are possible. reflector is also practical, the reflector optimally splitting the
light point for wide asymmetric glare-free light: it can be
adjusted via simple pushing in the horizontal plane, thus
allowing it to be precisely matched to the specific lighting
task at hand.
3.59
Road luminaires | Mast luminaires 3
Features Housing
— three construction sizes for a wide spectrum of Luminaire housing, supporting frame and mast flange of
applications diecast aluminum, light gray (RAL 7035) | peripheral EPDM
— IP65 protection rating for lamp compartment and control seal in the housing profile | mast flange in 4 sizes for various
gear compartment mast diameters, for post-top or side-entry mounting, for lu-
— high-quality sealing system with air-permeable membra- minaire inclination 0°, 3°, 8° or 15° | central rotary catch
ne for optimal pressure equalization opens optical enclosure and control gear compartment | flat
— flat cover panel for minimal glare and increased optical enclosure of toughened safety glass with frame of
protection against vandalism glass-fiber-reinforced polyester or diffuser of PMMA or PC |
— individually settable lighting technology via radial pressure equalization system with air-permeable membrane
facetted optics for condensation avoidance in the housing | insulation class:
— high luminaire light output ratios II | protection rating: IP65
— electrical unit replaced without tools
— central rotary catch Applications
— adjustable inclination (0°, 3°, 8°, 15°) — luminaires with flat cover have low light immission;
especially suitable for immission-minimized lighting
Lighting technology installations
Wide light distribution and high uniformity due to highly — SR 50 suitable for residential areas, ancillary roads,
efficient radial facetted optics | variable light-band deflection residential streets and collection roads
via adjustable optics | high level of system efficiency in watt — SR 100 suitable for collecting roads, through-roads and
ratings up to 400W with system-optimized light distribution main thoroughfares
and wide luminaire spacing | optical enclosure is either flat — SR 200 suitable for main thoroughfares, expressways
cover panel of toughened safety glass for minimized light im- and motorways
mission, or transparent enclosure — SR 100 and SR 200 with special reflector unit for
pedestrian crossings
SR 50 and SR 100 as special version for German Railways — SR 50 with extremely wide distribution reflector unit for
cycle paths
SR 100 and SR 200 with reflector unit for pedestrian
crossings, asymmetric left or right-sided distribution
Electrics
Canopy and control gear compartment opened without
tools, can be folded upwards; with automatic all-pole power
disconnection when folding down the control gear compart-
ment | tool-free relamping | all electric components mounted
on removable gear tray; connection via plug-in coupling |
luminaire wired ready for connection with 2-pole terminal,
max. 2.5mm² (version with reducing circuit: 2-pole + 1-pole
for 230V control wire, max. 1,5mm²) | optionally with efficient
electronic control gear (ECG) and Street Light Control (SLC)
light management components (SLC: central control and
monitoring of intelligent light points) or with CCG with
parallel p.f. correction | special versions also available with
power-factor-corrected CCG and ignition device for instant
hot re-ignition | power reduction: USt = 230V → 100% lumi-
nous flux; USt = 0V → 50% luminous flux (with start in power
reduction mode: 100% mode initially for approx. 6min.)
3.60
3 Road luminaires | Mast luminaires
0% 0°
606 288
178
197
Aw=0,10 m²
SR 50
1$06 with radial facetted optics | with flat cover panel | dimmable with ECG
[+,7 &(6RG:FIOP
Mast mounting element, 3-fold, cast aluminum, spigot size: 76mm 6.5 4039806350480 5NA55103MA76
P
3.61
Road luminaires | Mast luminaires 3
0% 0°
606 288
178
197
Aw=0,10 m²
SR 50
1$(06 with radial facetted optics | with flat cover panel | with ECG or CCG
[+67 0)://IOP
/XPLQRXVLQWHQVLW\FODVV 10
DFFRUGLQJWR
(1*
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is required
2) ballast with 2x power tapping 50/70W
— please order mast fl ange according to spigot diameter separately
Mast mounting element, 2-fold, cast aluminum, spigot size: 76mm 5.3 4039806350473 5NA55102MA76
Mast mounting element, 3-fold, cast aluminum, spigot size: 76mm 6.5 4039806350480 5NA55103MA76
P
3.62
3 Road luminaires | Mast luminaires
606 288
178
238
Aw=0,11 m²
1$(06
SR 50
[+67 0)://IOP with radial facetted optics | with diffuser | with CCG
Mast luminaire for post-top or side-entry — mast spigot with post-top mounting:
mounting via mast flange da = 60 x 100mm, da = 76 x 130mm
— with radial facetted optics, asymmetric — mast spigot with side-entry mounting:
wide distribution; with diffuser da = 42/48/60 x 100mm
— with CCG, parallel p.f. corrected, with — recommended mounting height:
power reduction according to version LPH = 4…6m
— housing, supporting frame and mast — luminaire can be mounted via mast
flange of diecast aluminum; all parts light flange at inclination angles 0°, 3°, 8° or 15°
gray (RAL 7035); cover of PMMA
FGNOP — type of protection: IP65
— insulation class: II
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
P
3.63
Road luminaires | Mast luminaires 3
606 288
178
238
Aw=0,11 m²
SR 50
1$(05
extremely wide distribution for cycle paths | with diffuser | with CCG
[+67 0)://IOP
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1
Light source Order no. Order no.
OSRAM Siteco
1x HST 50 W 1) E27 10.0 CCG 4039806422743 5NA551E1MR01
1x HST 70 W 1) E27 X 7.3 CCG 4039806422750 5NA551E1MR11
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.64
3 Road luminaires | Mast luminaires
0% 0°
807 358
198
216
Aw=0,16 m²
SR 100
1$27
[+,7 &(6RG:F
with radial facetted optics | with flat cover panel | dimmable with ECG
IOP
Mast luminaire for post-top or side-entry — type of protection: IP65
mounting via mast flange — insulation class: II
— with radial facetted optics, asymmetric — mast spigot with post-top mounting:
wide distribution; with flat cover da = 60 x 100mm, da = 76 x 130mm
— electronic control gear (ECG); according — mast spigot with side-entry mounting:
to version either with interface for da = 42/48/60 x 100mm
dimming of luminaire (for external SLC — recommended mounting height:
luminaire controller in mast) or with SLC LPH = 6…10m
luminaire controller (in luminaire) — luminaire can be mounted via mast
— housing, supporting frame and mast flange at inclination angles 0°, 3°, 8°
FGNOP
flange of diecast aluminum; frame for or 15°
glass cover of GRP; all parts light gray
& & (RAL 7035); cover of toughened safety
glass
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR SLC luminaire controller:
(1* • for brightness control of lamps (according to specifications of lamp manufacturer) without supplementary signal line
• SLC luminaire controller in the luminaire: control via LON PowerLine without supplementary signal line
• external SLC luminaire controller (in mast): control without supplementary signal line outside of mast, according to specification
via LON-PowerLine or via audio frequency ripple control
• supplementary SLC light management components are required for customer-specific light control and
evaluation of signals regarding operational condition of luminaires and lamps
Mounting height 8m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.65
Road luminaires | Mast luminaires 3
3.66
3 Road luminaires | Mast luminaires
0% 0°
807 358
198
216
Aw=0,16 m²
SR 100
1$17
with radial facetted optics | with flat cover panel | with ECG or CCG
[+67 0)://IOP
/XPLQRXVLQWHQVLW\FODVV 10
DFFRUGLQJWR
(1*
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is required
— please order mast fl ange according to spigot diameter separately
Mast mounting element, 2-fold, cast aluminum, spigot size: 76mm 5.3 4039806350473 5NA55102MA76
Mast mounting element, 3-fold, cast aluminum, spigot size: 76mm 6.5 4039806350480 5NA55103MA76
P
3.67
Road luminaires | Mast luminaires 3
807 358
198
300
Aw=0,18 m²
SR 100
1$(37
with radial facetted optics | with diffuser | with CCG
[+67 0)://IOP
Mast luminaire for post-top or side-entry — mast spigot with post-top mounting:
mounting via mast flange da = 60 x 100mm, da = 76 x 130mm
— with radial facetted optics, asymmetric — mast spigot with side-entry mounting:
wide distribution; with diffuser da = 42/48/60 x 100mm
— with CCG, parallel p.f. corrected, with — recommended mounting height:
power reduction according to version LPH = 6…10m
— housing, supporting frame and mast — luminaire can be mounted via mast
flange of diecast aluminum; all parts light flange at inclination angles 0°, 3°, 8°
gray (RAL 7035); cover of PMMA or PC or 15°
FGNOP — type of protection: IP65
— insulation class: II
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
Diffuser, PMMA, with CCG with thermal protection, pf-corrected
1x HST 100 W E40 13.6 CCG 4039806420596 5NA552E1NT01
1x HST 100 W E40 X 13.8 CCG 4039806420619 5NA552E1NT11
1x HST 150 W E40 14.0 CCG 4039806419231 5NA552E1PT01
1x HST 150 W E40 X 14.5 CCG 4039806419996 5NA552E1PT11
1x HST | HSE 50 W 1) E27 13.4 CCG 4039806420534 5NA552E1MS01
1x HST | HSE 70 W E27 X 13.4 CCG 4039806420541 5NA552E1MS11
1x HSE 100 W E40 11.0 CCG 4039806420572 5NA552E1NE01
1x HSE 100 W E40 X 11.0 CCG 4039806420589 5NA552E1NE11
1x HSE 150 W E40 14.2 CCG 4039806420626 5NA552E1PE01
1x HSE 150 W E40 X 14.5 CCG 4039806420633 5NA552E1PE11
P
3.68
3 Road luminaires | Mast luminaires
3.69
Road luminaires | Mast luminaires 3
807 358
198
300
Aw=0,18 m²
SR 100
1$(37)5
single-sided asymmetric distribution for pedestrian crossings | with diffuser | with CCG
[+67 0)://IOP
Mast luminaire for post-top or side-entry — mast spigot with post-top mounting:
mounting via mast flange da = 60 x 100mm, da = 76 x 130mm
— with reflector unit for pedestrian — mast spigot with side-entry mounting:
crossings, asymmetric left or right-sided da = 42/48/60 x 100mm
distribution; with diffuser — recommended mounting height:
— with CCG, with parallel p.f. correction LPH = 6…10m
— housing, supporting frame and mast — luminaire can be mounted via mast
flange of diecast aluminum; all parts light flange at inclination angles 0°, 3°, 8°
gray (RAL 7035); cover of PMMA or 15°
FGNOP — type of protection: IP65
— insulation class: II
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
asymmetric, left
1x HST 150 W E40 12.5 CCG 4039806517999 5NA552E1PT01FL
asymmetric, right
1x HST 150 W E40 12.5 CCG 4039806518002 5NA552E1PT01FR
P
3.70
3 Road luminaires | Mast luminaires
0% 0°
870 358
198
216
Aw=0,18 m²
SR 200
1$37
with radial facetted optics | with flat cover panel | dimmable with ECG
[+67 0)://IOP
Mounting height 8m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.71
Road luminaires | Mast luminaires 3
3.72
3 Road luminaires | Mast luminaires
0% 0°
870 358
198
216
Aw=0,18 m²
SR 200
1$37 with radial facetted optics | with flat cover panel | with ECG
[+67 0)://IOP
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is required
— please order mast fl ange according to spigot diameter separately
— please order SLC luminaire controller and SLC light management components separately if required
Mounting height 8m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.73
Road luminaires | Mast luminaires 3
870 358
198
300
Aw=0,20 m²
SR 200
1$(67 with radial facetted or bowl reflector optics | with diffuser | with CCG
[+67 0)://IOP
/XPLQRXVLQWHQVLW\FODVV 10
DFFRUGLQJWR
(1*
PC diffuser material
1x HSE 400 W E40 17.4 CCG 4039806421333 5NA553E1TE03
1x HST 400 W E40 17.4 CCG 4039806251343 5NA553E1TT03
1x HSE 400 W E40 X 14.5 CCG 4039806421340 5NA553E1TE13
1x HST 400 W E40 X 14.5 CCG 4039806421364 5NA553E1TT13
Mounting height 12m
0RXQWLQJKHLJKWP7LOW Tilt 0° Designation Wt. (kg) Order no. Order no.
O[
OSRAM Siteco
Mast flange, light gray (RAL 7035), aluminum, diecast, spigot size: 48mm 0.5 4039806060464 5NA55100XM3
Mast flange, light gray (RAL 7035), aluminum, diecast, spigot size: 60mm 0.6 4039806060440 5NA55100XM2
Mast flange, light gray (RAL 7035), aluminum, diecast, spigot size: 76mm 0.8 4039806060426 5NA55100XM1
Mast mounting element, 2-fold, cast aluminum, spigot size: 76mm 5.3 4039806350473 5NA55102MA76
P
Mast mounting element, 3-fold, cast aluminum, spigot size: 76mm 6.5 4039806350480 5NA55103MA76
3.74
3 Road luminaires | Mast luminaires
870 358
198
300
Aw=0,20 m²
SR 200
1$(67)/
single-sided asymmetric distribution for pedestrian crossings | with diffuser | with CCG
[+67 0)://IOP
Mast luminaire for post-top or side-entry — mast spigot with post-top mounting:
mounting via mast flange da = 60 x 100mm, da = 76 x 130mm
— with reflector unit for pedestrian — mast spigot with side-entry mounting:
crossings, asymmetric left or right-sided da = 42/48/60 x 100mm
distribution; with diffuser — recommended mounting height:
— with CCG, with parallel p.f. correction LPH = 8…12m
— housing, supporting frame and mast — luminaire can be mounted via mast
flange of diecast aluminum; all parts light flange at inclination angles 0°, 3°, 8°
gray (RAL 7035); cover of PMMA or PC or 15°
FGNOP — type of protection: IP65
— insulation class: II
& &
10
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
asymmetric left
Diffuser, PMMA, with CCG with thermal protection, pf-corrected
1x HST 150 W E40 13.5 CCG 4039806372253 5NA553E1PT01FL
1x HST 250 W E40 18.9 CCG 4039806372291 5NA553E1ST01FL
asymmetrisch rechts
Diffuser, PMMA, with CCG with thermal protection, pf-corrected
1x HST 150 W E40 13.5 CCG 4039806372260 5NA553E1PT01FR
1x HST 250 W E40 18.9 CCG 4039806372307 5NA553E1ST01FR
Mounting height 10m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
Mandatory accessories (for details see page 3.76 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Mast flange, light gray (RAL 7035), aluminum, diecast, spigot size: 48mm 0.5 4039806060464 5NA55100XM3
P
Mast flange, light gray (RAL 7035), aluminum, diecast, spigot size: 60mm 0.6 4039806060440 5NA55100XM2
Mast flange, light gray (RAL 7035), aluminum, diecast, spigot size: 76mm 0.8 4039806060426 5NA55100XM1
Mast mounting element, 2-fold, cast aluminum, spigot size: 76mm 5.3 4039806350473 5NA55102MA76
3.75 Mast mounting element, 3-fold, cast aluminum, spigot size: 76mm 6.5 4039806350480 5NA55103MA76
Road luminaires | Mast luminaires 3
Mast flange
For installing SR luminaire as post-top or side-entry luminaire via twisting of mast flange |
luminaire inclination set via mast flange (0°, 3°, 8°, 15°) | various mast flanges for differing
mast spigot diameters | mast flange of diecast aluminum, light gray (RAL 7035)
— Mast fl ange not included in luminaire delivery; please order mast fl ange separately according to mast spigot diameter
da Typ 76 Typ 60
l
For SR luminaire installation with twin or triple mounting | luminaire inclination set via mast
flange (0°, 3°, 8°, 15°) | mast flange of sandcast aluminum, light gray (RAL 7035) mast spigot:
da x L = 76 x 130mm
3.76
3 Road luminaires | Mast luminaires
Socket adapter
For use of HIT-CE-P with E27 base in luminaires with E40 socket
Frame of GRP, light gray (RAL 7035); cover of toughened safety glass diffuser cover,
transparent | PMMA or PC
PMMA diffuser
for SR 50 0.3 4039806613080 5NA55100XW
for SR 100 0.3 4039806613097 5NA55200XW
for SR 200 0.3 4039806070067 5NA55300XW
PC diffuser
for SR 50 0.4 4039806070111 5NA55110XW
for SR 100 0.4 4039806613103 5NA55210XW
for SR 200 0.4 4039806070081 5NA55310XW
For detailed information about intelligent control Masts, brackets and special mounting accessories
of Siteco® luminaires, see chapter 6 are specified in chapter 7
3.77
Road luminaires | Mast luminaires 3
3.78
3 Road luminaires | Mast luminaires
ST luminaires
Modern road luminaire with housing of glass fibre reinforced
plastic with functional design and innovative technology.
Equipped with state-of-the-art lighting technology and
precise optics, they offer outstanding solutions in relation to
energy efficiency, luminaire spacing, light quality and service
life. A homogeneous road appearance can be designed due
to various construction sizes and two optical enclosures (flat
cover panel, convex enclosure) and various lamping options
for differing light distribution characteristics, and at the same
time a wide spectrum of lighting tasks are fulfilled
Features Housing
— lightweight, glass-fibre reinforced polyester housing Luminaire cover of glass fibre reinforced plastic, light grey
— high IP65 protection rating for lamp compartment and (RAL 7035); supporting frame and mast clamping element of
control gear compartment diecast aluminium, aluminium grey (RAL 9007) | peripheral
— maintenance-friendly; opened via rotary catch EPDM seal in the housing profile | central rotary catch opens
— high performance facetted optic optical enclosure and control gear compartment | luminaire
— high quality sealing system cover either flat cover of toughened safety glass, with frame
— universal mounting clamp for post-top and side-entry of diecast aluminium or enclosure of PMMA | integrated
mounting clamp element for post-top and side-entry mounting; 0°, 2°
— 2° or 8° inclination with post-top mounting or 8° inclination with with post-top mounting, with offset
mast spigot with side-entry mounting | pressure equalisation
Lighting technology system with air-permeable membrane for condensation
Wide light distribution and high uniformity due to highly avoidance in the housing | insulation class: II | Protection
efficient radial facetted optics | variable light-band deflection rating: IP65 for complete luminaire (dustproof and water-jet
via adjustable optics | high level of system efficiency in watt proof)
ratings to 400W with system-optimised light distribution and
wide luminaire spacing | optical enclosure is either flat cover Applications
panel of toughened safety glass for minimised light immis- — luminaires with flat cover have low light immission;
sion, or transparent enclosure (PMMA) especially suitable for lighting installations with minimal
immission
Electrics — ST 50 suitable for residential areas, ancillary roads,
Cover for lamp and control gear compartment opened with- residential and collection roads
out tools, can be hinged downwards | tool-free relamping | — ST 100 suitable for collecting roads, through-roads and
all electric components mounted on removable gear tray; main thoroughfares
connection via plug-in coupling, with automatic power dis-
connection with removal of gear tray | luminaire wired ready
for connection, with 2-pole terminal, max. 2.5mm² (version
with reducing circuit: 2-pole + 1-pole for 230V control wire,
max. 1.5mm²) | with CCG, with parallel p.f. correction |
according to version with power reduction; power reduction:
USt = 230V → 100% luminous flux; USt = 0V → 50% lumi-
nous flux (with start in power reduction mode: 100% mode
initially for approx. 6mins.)
3.79
Road luminaires | Mast luminaires 3
0%
616 290
174
Aw=0,08 m²
ST 50
1$(06
with radial facetted optics | with flat cover panel
[+67 0)://IOP
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
1x HST | HSE 50 W 1) E27 7.0 CCG 4039806521224 5NA392E1MS02
1x HST | HSE 70 W E27 X 7.2 CCG 4039806521262 5NA392E1MS12
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.80
3 Road luminaires | Mast luminaires
616 290
224
Aw=0,10 m²
ST 50
1$(06
with radial facetted optics | with diffuser
[+67 0)://IOP
10
& &
/XPLQRXVLQWHQVLW\FODVV
Light source Order no. Order no.
DFFRUGLQJWR
(1* OSRAM Siteco
1x HST | HSE 50 W 1) E27 6.6 CCG 4039806521200 5NA392E1MS01
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.81
Road luminaires | Mast luminaires 3
0%
746 290
194
Aw=0,12 m²
ST 100
1$(37
with radial facetted optics | with flat cover panel
[+67 0)://IOP
10
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
1x HST | HSE 150 W E40 X 10.4 CCG 4039806625274 5NA393E1PT12
1x HST | HSE 250 W E40 10.2 CCG 4039806625335 5NA393E1ST02
1x HST | HSE 250 W E40 X 10.9 CCG 4039806625359 5NA393E1ST12
1x HST | HSE | HIT-CE 150 W 1) E40 9.7 CCG 4039806625243 5NA393E1PT02
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is required
Mounting height 8m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.82
3 Road luminaires | Mast luminaires
746 290
270
Aw=0,15 m²
ST 100
1$(37
with radial facetted optics | with diffuser
[+67 0)://IOP
10
& &
/XPLQRXVLQWHQVLW\FODVV
Light source Order no. Order no.
DFFRUGLQJWR
(1* OSRAM Siteco
1x HST | HSE | HIT-CE-P 150 W 1) E40 8.3 CCG 4039806625236 5NA393E1PT01
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is required
Mounting height 8m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
3.83
Road luminaires | Mast luminaires 3
l1
PMMA enclosure
for ST 50 4039806265838 5NA39200XW1
for ST 100 4039806265890 5NA39300XW1
3.84
3 Road luminaires | Mast luminaires
SiCOMPACT® A2 MIDI
The floodlights of the SiCOMPACT® A2 MIDI family become the SiCOMPACT® A2 MIDI floodlight complies with the EU
technical road luminaires via special optics for road traffic, guidelines for Dark Sky criteria. Various lamp wattages are
emitting wide light distribution with low stray light and a high available for various photometric tasks.
level of visual comfort. They can be used as mast or wall
luminaires with use of special connections. There is no light
immission (0%) due to horizontal alignment, meaning that
Features Housing
— pressure equalization port with air-permeable membrane Housing of of diecast aluminum with rear housing connec-
prevents build-up of condensation in housing tion for mast and wall adapter; wall and mast adapter of
— low windage area galvanized steel; all parts coated in Siteco® metallic gray (DB
— luminaire cover of safety glass with all-round silicone 702S) | all-round silicone gasket in housing profile | cover of
sealing; IP66 protection rating flat, toughened safety glass | pressure equalization system
— asymmetrical light distribution limits glare and stray light with air-permeable membrane for condensation avoidance
— Siteco® Savelight components for greater safety, higher in the housing | insulation class: I | protection rating: IP66
energy savings, longer lamp service life and lower main-
tenance costs Applications
— mast adapter as 1, 2, 3 or 4-fold bracket — residential streets
— trunk roads
Lighting technology — through-roads
Asymmetric wide light distribution for standard-compliant — main roads
lighting according to DIN EN 13201 | no light spill to upper
hemisphere (light immission 0%) via flat cover and horizontal
alignment of light emission surface
Electrics
Luminaire wired ready for connection | with 3-pole
connection terminal, max. 2.5mm² | cable entry for cable
D = 6…12mm | with power-factor-corrected CCG
3.85
Road luminaires | Mast luminaires 3
998
565
420
60
0% 0°
501
155
246
Aw=0,08 m²
Luminaire for mounting to mast via mast — housing with rear fixing of diecast alumi-
bracket num, Siteco® metallic gray (DB 702S);
— with aluminum reflector cover of toughened safety glass
— highly specular, asymmetric wide — type of protection: IP66
distribution (road lighting technology); — insulation class: II
with flat cover — recommended mounting height:
— with CCG, with parallel p.f. correction LPH = 6…10m
Light source Order no. Order no.
OSRAM Siteco
1x HST | HIT-CE/S-od 70 W E27 12.4 CCG 4039806849939 5NA750E1MT21
1x HST | HIT-CE/S-od 100 W E40 11.7 CCG 4039806849953 5NA750E1NT21
1x HST | HIT-CE/S-od 150 W E40 13.1 CCG 4039806849977 5NA750E1PT21
1x HST | HIT-CE/S-od 250 W E40 14.0 CCG 4039806849991 5NA750E1ST21
,PD[FGNOPDWJ
Mandatory accessories (for details see page 3.88 ff.)
& &
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Mast bracket for 1 floodlight, spigot size: 76mm 6.0 4039806856937 5NY75801XA21
Mast bracket for 2 floodlights, spigot size: 76mm 9.0 4039806911193 5NY75802XA11
Mast bracket for 2 floodlights, spigot size: 89mm 9.3 4039806856951 5NY75802XA21
Mast bracket for 3 floodlights, spigot size: 89mm 11.0 4039806856968 5NY75803XA21
Mast bracket for 4 floodlights, spigot size: 89mm 16.8 4039806856975 5NY75804XA21
Mounting height 8m
/LFKWSXQNWKÓKHP1HLJXQJ Tilt 0°
O[
P
3.86
3 Road luminaires | Mast luminaires
565
420
0% 0°
155
153
Aw=0,08 m²
678
Luminaire for wall mounting via wall adapter — type of protection: IP66
— with aluminum reflector — insulation class: II
— highly specular, asymmetric wide distri- — recommended mounting height:
bution (road lighting technology); with flat LPH = 6…10m
cover
— with CCG, with parallel p.f. correction
— housing with rear fixing of diecast
aluminum, Siteco® metallic gray (DB
702S);
FGNOP — cover of toughened safety glass (TSG)
FGNOP
10
Light source Order no. Order no.
OSRAM Siteco
1x HST | HIT-CE/S-od 70 W E27 12.4 CCG 4039806849939 5NA750E1MT21
1x HST | HIT-CE/S-od 100 W E40 11.7 CCG 4039806849953 5NA750E1NT21
1x HST | HIT-CE/S-od 150 W E40 13.1 CCG 4039806849977 5NA750E1PT21
1x HST | HIT-CE/S-od 250 W E40 14.0 CCG 4039806849991 5NA750E1ST21
,PD[FGNOPDWJ
— please order wall adapter separately
& &
Mandatory accessories (for details see page 3.88 ff.)
Mounting height 8m
/LFKWSXQNWKÓKHP1HLJXQJ Tilt 0°
O[
P
3.87
Road luminaires | Mast luminaires 3
Mast mounting element with single or multiple bracket | galvanized and coated steel, Siteco®
metallic gray (DB 702S) | with 5NY75701XA …: mast mounting element of aluminum
Designation Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
da Mounting information
Mast spigot: da x l
l
a1 a2 a3 a4
b
c
da da da da
3.88
3 Road luminaires | Mast luminaires
Mast mounting element with multiple bracket | galvanized and coated steel, Siteco® metallic
gray (DB 702S) | multiple bracket replaces the luminaire mounting bracket, luminaire
connection to the fixing points of the mounting bracket | adjustment of luminaire in 5° steps
Designation Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
da Mounting information
Mast spigot: da x l
l
a2 a3 a4
c
d2 d3 d4
3.89
Road luminaires | Mast luminaires 3
Wall adapter
Wall flange, cover and adapter of galvanized and coated steel, in Siteco® metallic gray
(DB 702S) | wall flange via supplementary cover without visible screws
Cover panel
for SiCOMPACT A2 MIDI 4039806440914 5NA75200XG08
3.90
3 Road luminaires | Mast luminaires
SiSTELLAR® MAXI
The SiSTELLAR® MAXI enables mounting heights of 10 to space for six lamps. These are fitted on their own supports
16 meters, thus illuminating especially wide areas, and as a with socket, electrical connection and reflector bowl. By
lighting system enables wide luminaire spacing. In addition, rotating this reflector system in steps of 30 to 150 degrees,
each luminaire can be individually adapted to the specific various light distribution characteristics can be achieved.
requirements in this lighting field. This is achieved by the
special construction of the lamp compartment, which provides
3.91
Road luminaires | Mast luminaires 3
Features Housing
— large-area luminaire for high mounting heights Housing and central canopy element of sheet aluminum with
— central supporting frame for mast mounting dripping edge, metallic gray textured (RAL 9007) surface;
— lamp compartment with all-round wool-felt seal with central mounting frame for central mast connection of steel,
active breathing properties coated light gray (RAL 7035) | all-round wool-felt gasket |
— weather-resistant due to coated surface 3-part segmented cover of flat, toughened safety glass | in-
— SiVARIAL lighting technology for individually settable light sulation class: I or II | protection rating: IP44
distribution, can be preset by the manufacturer
— electrical gear clearly arranged Applications
— many lamp variations available Especially suitable for glare-free lighting installations
— railway approval such as:
— marshalling yards and shipping routes
Lighting technology — crossing areas of multi-lane roads
SiVARIAL reflector units with lamp sockets can be individu- — parking spaces
ally rotated on-site in 15° steps | individual, application-
optimized light distribution: illumination is circular, rectangular,
linear, x-shaped, asymmetric narrow or asymmetric wide
Electrics
Luminaire wired ready for connection | with 4-pole connec-
tion terminal (version with insulation class I: additionally with
PE connection), max. 2.5mm² | lamps configured in 3 swit-
ching groups (version with reducing circuit: 2 switching
groups) | electrical control components on central mounting
frame, access from above via central canopy element |
power reduction: USt = 230V → 100% luminous flux;
USt = 0V → 50% luminous flux (with start in power reduction
mode: 100% mode initially for approx. 6min.) | tool-free
relamping
3.92
3 Road luminaires | Mast luminaires
0%
ø1500
280
365
ø108
Aw=0,47 m²
& &
Light source Order no. Order no.
/XPLQRXVLQWHQVLW\FODVV
OSRAM Siteco
DFFRUGLQJWR
(1* Insulation class I (protective earth), with CCG with thermal protection, pf-corrected
6x HST 150W E40 X 90.1 CCG 4039806250612 5NA630E6SR
6x HST 250W E40 X 98.5 CCG 4039806250520 5NA630E6NR
6x HST 400W E40 96.0 CCG 4039806250827 5NA630E6V
6x HST 400W E40 X 108.8 CCG 4039806250834 5NA630E6VR
6x HST | HIT-CE 150W 1) E40 89.3 CCG 4039806250605 5NA630E6S
6x HST | HIT-CE 250W E40 97.7 CCG 4039806250513 5NA630E6N
6x HSE 150W E40 89.3 CCG 4039806250674 5NA630E6T
6x HSE 150W E40 X 90.1 CCG 4039806250681 5NA630E6TR
6x HSE 250W E40 97.7 CCG 4039806250742 5NA630E6U
6x HSE 250W E40 X 98.5 CCG 4039806250759 5NA630E6UR
Insulation class II (protective earth), with CCG with thermal protection, pf-corrected
6x HST 150W E40 X 85.9 CCG 4039806250964 5NA650E6SR
6x HST 250W E40 X 101.0 CCG 4039806250940 5NA650E6NR
6x HST 400W E40 104.4 CCG 4039806251015 5NA650E6V
6x HST | HIT-CE 150W 1) E40 85.1 CCG 4039806250957 5NA650E6S
0RXQWLQJKHLJKWP7LOW
6x HST | HIT-CE 250W E40 100.2 CCG 4039806250933 5NA650E6N
O[
6x HSE 150W E40 85.1 CCG 4039806250971 5NA650E6T
6x HSE 150W E40 X 85.9 CCG 4039806250988 5NA650E6TR
6x HSE 250W E40 100.2 CCG 4039806250995 5NA650E6U
6x HSE 250W E40 X 101.0 CCG 4039806251008 5NA650E6UR
1) with use of OSRAM HCI-E/P or HCI-T/P lamps, an E40/E27 socket adapter (5NA59000XF) is required
P
3.93
Road luminaires | Mast luminaires 3
Suction pad
da
Mounting information
Mast spigot: da x L = 108…118 x 280mm
l
3.94
4 Luminaires for special applications | Overview
21m
18m
15m
12m
9m
6m
3m
SiSTELLAR ® MAXI SR 100 SR 50 DL® 500 MAXI DL® 500 MIDI SiCOMPACT® TV 10 SiCOMPACT®
Page 4.31 Page 4.15 Page 4.15 Page 4.9 Page 4.9 A2 MIDI Page 4.61 A2 MINI
Page 4.21 Page 4.21
Page 4.51 Page 4.51
4.1
Luminaires for special applications | Overview 4
21m
18m
15m
12m
9m
6m
3m
Streetlight 10 midi LED SiCOMPACT® A2 MINI LED SiCOMPACT® A2 MIDI LED SR 100 SR 200
Page 4.35 Page 4.47 Page 4.47 Page 4.41 Page 4.41
4.2
4 Luminaires for special applications | Overview
4.3
Luminaires for special applications | Overview 4
DL® 500 MIDI DL® 500 MAXI SR 50 SR 100 SiCOMPACT® SiCOMPACT® SiSTELLAR ®
A2 MINI A2 MIDI MAXI
Page 4.9 Page 4.9 Page 4.15 Page 4.15 Page 4.21 Page 4.21 Page 4.31
Security luminaires
Robust luminaires for underpasses, underground car parks, shelters and tribune areas
TV 10
Page 4.61
4.4
4 Luminaires for special applications | Product search
Light source
— HIT/HIT-CE/HIT-DE ¢/-/¢
— HIE-CE/HIE-CE-P
— TE-LEL/TC-TEL
— HST/HST-DE/HSE ¢/-/- ¢/-/- ¢/-/¢ -/-/¢ ¢/¢/- ¢/-/-
Insulation class II II II II II II
Recommended mounting height (m) 4…6 6…8 4…6 6…10 3…6 6…10
Recommended applications
— surface illumination
— facade lighting
Special applications
— glare-free lighting installations ¢ ¢ ¢ ¢ ¢ ¢
— marshalling yards and railway tracks ¢ ¢ ¢ ¢ ¢ ¢
— shipping routes ¢ ¢ ¢ ¢ ¢ ¢
— railway platforms ¢ ¢ ¢
— German Railways ¢ ¢ ¢ ¢ ¢ ¢
— security lighting
— areas with video monitoring
— security lighting for industrial facilities
— airports
Lighting technology
— asym. extremely wide distribution ¢
— asym. wide distribution ¢ ¢ ¢ ¢
— variably adjustable reflector
— asym. narrow ¢ ¢
— asym. wide ¢ (MIDI) ¢
Features
— additional E27 socket ¢
— hot re-ignition
— instant light
4.5
Luminaires for special applications | Product search 4
SiSTELLAR ®
MAXI
¢/-/-
IP44
II
10…16
¢
¢
¢
0%
4.6
4 Luminaires for special applications | Product search
Security luminaires
Light source
— LED ¢ ¢ ¢
— HIT/HIT-CE/HIT-DE -/-/¢ -/-/¢ -/-/¢
— HIE-CE/HIE-CE-P
— TE-LEL/TC-TEL
— HST/HST-DE/HSE -/¢/- -/¢/- -/¢/-
— T16/T26
Insulation class II II I II II II
Recommended applications
— surface illumination ¢ ¢
— facade lighting ¢ ¢
Special applications
— glare-free lighting installations ¢ ¢ ¢ ¢ ¢ ¢
— marshalling yards and railway tracks
— shipping routes
— railway platforms
— German Railways
— security lighting ¢ ¢ ¢ ¢ ¢ ¢
— areas with video monitoring ¢ ¢ ¢ ¢ ¢ ¢
— security lighting for industrial facilities ¢ ¢ ¢ ¢ ¢ ¢
— airports ¢ ¢ ¢ ¢ ¢ ¢
Lighting technology
— asym. extremely wide distribution
— asym. wide distribution ¢ ¢ ¢ ¢ ¢ ¢
— variably adjustable reflector
— asym. narrow
— asym. wide
Features
— additional E27 socket
— hot re-ignition ¢ ¢ ¢
— instant light ¢ ¢ ¢
4.7
Luminaires for special applications | Product search 4
Robust luminaires
SiCOMPACT® TV 10
A2 MIDI
-/-/¢
-/¢/-
¢/¢
IP44 IP65
II II
6…10 2…3
¢
¢
¢
¢
¢
¢
0% 0°
¢ ¢
¢ ¢
¢ ¢
4.8
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
DL® 500
The mast light for railway platforms/tracks and shipping Despite its robust construction and high IP65 protection
routes from the DL® 500 luminaire range fulfills the high rating, the DL® 500 luminaire is easy to handle: The lamp
demands of such special security applications due to high- cover is opened downwards by releasing two robust twist-
quality materials (luminaire housing made of diecast alu- lock catches. Access to the lamp space is available. A further
minum), state-of-the-art lighting technology, and very precise twist-lock catch secures the gear tray with lamp socket and
optics. lamp that can also be folded downwards. This cuts off the
power supply; maintenance and checks as well as gear tray
With an efficient radial faceted reflector as well as an photo- replacement can be carried out without danger.
metric cover made of flat toughened safety glass that mini-
mizes light spill, the DL® 500 ensures glare-free light distribu-
tion and high lighting intensities. The radial faceted reflector,
which can be adjusted horizontally by simply sliding, creates
extremely wide, asymmetric light distribution.
4.9
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
4.10
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
0%
750
188
350
ø100
Aw=0.20 m²/
ø500
Aw=0.40 m²
10
& &
0RXQWLQJKHLJKWP7LOW
O[
P
4.11
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
0%
850
210
370
ø100
Aw=0.28 m²/
ø600
Aw=0.40 m²
10
& &
0RXQWLQJKHLJKWP7LOW
O[
P
4.12
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
0%
850
210
370
ø100
Aw=0.28 m²/
ø600
Aw=0.56 m²
10
Mounting height 8m
0RXQWLQJKHLJKWP7LOW
Tilt 0°
O[
P
4.13
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
For mounting DL® 500 …- M | … -T | … -A luminaire on mast with spigot size da = 60mm
(post-top) or spigot size da = 42 mm (side-entry) | reducer made of diecast aluminum
Optical enclosure
Flat cover panel made of toughened safety glass | partly screen-printed | structured
Cover
DL 500 MIDI 1.00 4039806206626 5NA24700XG
DL 500 MIDI 1.20 4039806206602 5NA24600XG
Detailed information for intelligent control Masts, brackets, and special attachments
of Siteco® luminaires: chapter 6 are specified in Chapter 7
4.14
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
SR 50 and SR 100
The SR 50 and SR 100 for railway platforms/tracks and Despite their robust construction and high (IP65) protection
shipping routes from the SR luminaire range fulfills the high rating, the SR luminaires are easy to handle: A central rotary
demands of such special security applications due to state- catch at the bottom of the luminaire secures the optical cover
of-the-art lighting technology and very precise optics. Glare- and gear tray. The cover panel can be opened downwards
free light distribution, high lighting intensities, and good color by rotating the catch 180 degrees. Access to the lamp space
rendering and contrast are required. The SR luminaires fulfill is available. A further setting unlocks the gear tray with lamp
these tasks with highly illuminant light source variants as well socket and lamp that can also be hinged downwards. This
as with a flat cover panel as an optical cover that is designed cuts off the power supply; maintenance and control work as
for maximum light spill minimization. With a radial faceted well as gear tray replacement can be carried out without
reflector that optimally splits the light point and that can be danger.
adjusted horizontally by simply sliding, the luminaires
generate wide asymmetric, glare-free light distribution.
4.15
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
Features Housing
— radial faceted optics (for T and E lamps) Luminaire housing, support frame, and mast flange made of
— 0°, 3°, 8°, 15° alignment adjustment for a wide range of diecast aluminum, light gray (RAL 7035) | peripheral EPDM
applications seal in the housing profile | mast flange in 4 sizes for various
— protection rating IP65 mast diameters, for post-top or side-entry mounting, for
— high-quality sealing system with air-permeable membrane luminaire inclination 0°, 3°, 8°, or 15° | central rotary catch
for optimal pressure equalization opens optical cover and control gear compartment | flat
— electrical unit replaced without tools optical enclosure made of toughened safety glass with frame
of fiberglass-reinforced polyester | pressure equalization sys-
Lighting technology tem with air-permeable membrane to prevent condensation
Wide light distribution with high level of uniformity due to in the housing | insulation class: II | protection rating: IP65
highly efficient radial faceted optics | variable light-band de-
flection via adjustable optics | high level of system efficiency Applications
via optimized light distribution and large distances between For glare-free lighting installations such as railways and
luminaires | optical enclosure is flat cover panel of toughened shipping routes, approved for German Railways railway
safety glass for minimized light immission tracks (German rail system)
SR 50 asymmetric extremely wide distribution via cycle path
optics
Electrical system
Cover and control gear compartment can be opened without
tools and hinged downwards; automatic all-pole power
disconnection when control gear compartment hinged down-
wards | tool-free relamping | all electric components mounted
on removable gear tray; connection via plug-in coupling |
luminaire wired ready for connection, with 2-pole terminal,
max. 2.5mm² | with CCG, power-factor correction
4.16
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
0% 0°
606 288
178
197
Aw=0.10 m²
SR 50
1$(0(%
For railway systems and shipping routes | with radial faceted optics | with cover
[+67 0)://IOP
panel | with CCG
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
radial faceted optics, with CCG and thermal protection, power-factor correction
1x HST | HSE 50 W 1) E27 9.0 CCG 4039806892140 5NA551E1MEB
1x HSE 100 W E40 8.2 CCG 4039806892188 5NA551E1NEB
P
4.17
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
0% 0°
807 358
198
216
Aw=0.16 m²
SR 100
1$(3(%
For railway systems and shipping routes | with radial faceted optics | with cover
[+6(0)://IOP
panel | with CCG
Mast lights for post-top or side-entry — mast spigot with post-top mounting:
mounting via mast flange da = 76 x 130mm
— with radial faceted optics, asymmetric — recommended mounting height:
wide distribution, with flat cover LPH = 6 to 10m
— with CCG, power-factor correction — luminaire with factory-installed mast
— housing, support frame, and mast flange flange for spigot size da = 76mm,
made of diecast aluminum; frame for for spigot diameter
glass cover made of GRP; all parts light da = 42/48/60 x 100mm
FGNOP gray (RAL 7035); cover made of tough- — for mast flange suitable for post-top or
ened safety glass side-entry mounting, please additionally
— protection rating: IP65 order set at luminaire inclination 0°
& &
— insulation class: II — luminaire can be mounted via mast flange
/XPLQRXVLQWHQVLW\FODVV at inclination angles 0°, 3°, 8° or 15°
DFFRUGLQJWR
(1*
10
P
4.18
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
Mast flange
For installing the SR luminaire as a post-top or side-entry luminaire via twisting of mast flange
| luminaire inclination set via mast flange (0°, 3°, 8°, 15°) | various mast flanges for differing
mast spigot diameters | mast flange made of diecast aluminum, light gray (RAL 7035)
— mast flange not included in luminaire delivery; please order mast flange separately according to mast spigot diameter
da Typ 76 Typ 60
l
For mounting SR luminaires in 2x or 3x arrangement | luminaire inclination can be set via mast
flange (0°, 3°, 8°, 15°) | mast flange made of aluminum sand casting, light gray (RAL 7035)
spigot: da x l = 76 x 130mm
Detailed information for intelligent control Masts, brackets, and special attachments
of Siteco® luminaires: Chapter 6 are specified in Chapter 7
4.19
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
Frame made of GRP, light gray (RAL 7035); cover made of toughened safety glass
Detailed information for intelligent control Masts, brackets, and special attachments
of Siteco® luminaires: Chapter 6 are specified in Chapter 7
4.20
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
SiCOMPACT® A2
The asymmetric floodlights for railways/tracks and shipping With horizontal alignment of the light emission aperture, the
routes in the SiCOMPACT® A2 line of products with their pre- illuminated area can be lit such that less than 3% light spill is
cise optics fulfill the high demands in these special security emitted to the upper hemisphere. A highly specular anodized
applications. Glare-free light distribution, high lighting intensi- aluminum reflector ensures efficient light distribution. The
ties, and good color rendering and contrast are required. The floodlights can be precisely adjusted in 5° increments for
SiCOMPACT® A2 floodlights, with their highly illuminant light exact illumination of the application area. Integral twist
sources and a flat cover panel as the optical enclosure that protection permanently affixes the luminaires.
minimizes light spill, fulfill these requirements.
4.21
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
4.22
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
40
51 51
261
276
250
0% 0°
355
95
Aw=0.03 m²
196
SiCOMPACT® A2 MINI
1$(16%1$;%
For railway systems and shipping routes | asymmetric wide | with mounting bracket
[+,7 '(&(K:IOP
Light source Order no. Order no.
OSRAM Siteco
with integrated control gear, with integrated ignitor (with automatic power-off function)
1x HIT-DE | HST-DE 70 W RX7s 4.1 CCG 4039806907776 5NA757E1NS02B
1x HIT-DE | HST-DE 150 W RX7s 6.1 CCG 4039806909725 5NA757E1PS02B
— please order cross arm separately if required
,PD[FGNOPDWJ
Mandatory accessories (for details, see page 4.26 ff.)
& &
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Visor, black 0.6 4039806622716 5NA75700XB
0RXQWLQJKHLJKWP7LOW
O[
P
4.23
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
565
440
230
465
102
420 155
348
Aw=0.08 m²
0% 0°
50
0RXQWLQJKHLJKWP7LOW
O[
P
4.24
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
998
565
0% 0°
420
60
501
Aw=0.08 m²
155
246
SiCOMPACT® A2 MIDI
1$(37%
For railway systems and shipping routes | asymmetric narrow or wide |
[+67 0)://IOP
for mast bracket, rear connection
Floodlight for mounting to mast via mast — housing with rear attachment made of
bracket diecast aluminum, Siteco® metallic gray
— with aluminum reflector, highly specular, (DB 702S); cover of toughened safety
asymmetric wide distribution (road glass
lighting technology); with flat cover — protection rating: IP66
— with CCG, power-factor correction — insulation class: II
— recommended mounting height:
LPH = 6 to 10m
FGNOP
FGNOP
10
& &
P
4.25
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
Visor
To reduce glare when viewing from the side | stainless steel, painted black (RAL 9005, matte)
Louvre shielding
To reduce glare when viewing from the side | stainless steel, painted black (RAL 9005, matte)
Galvanized steel and painted, white aluminum (RAL 9006) | grid spacing 47 x 22mm; steel
wire: d = 3mm
4.26
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
Ground stake
102
Steel, galvanized
60
V4A bracket
Straight bracket
4.27
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
Mast mounting element with single or multiple bracket | galvanized steel, coated Siteco®
metallic gray (DB 702S) | with 5NY75701XA …: Post-top mounting element of aluminum
Designation Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
da Mounting information
Mast spigot: da x l
l
a1 a2 a3 a4
b
c
da da da da
Wall adapter
Wall flange, cover and adapter made of galvanized steel, coated in Siteco® metallic gray
(DB 702S) | wall flange via supplementary cover without visible screws
4.28
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
Cross-arm
da Mounting information
Mast spigot: da x l
l
b b
ø16 ø16 ø16
150
150
da da
ø16 ø16 ø14 ø14
62
62
b b1
1 2
Designation Fig. b (mm) b1 (mm) Mast spigot: Wt. Order no. Order no.
da x l (mm) (kg) OSRAM Siteco
— cross arm suitable for floodlight with max. weight: mmax = 1x 26kg or 2x 26kg
(please also note the static analysis and the permissible load limit of the mast)
4.29
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
Cover panel
For SiCOMPACT A2 MINI 4039806440938 5NA75700XG08
For SiCOMPACT A2 MIDI 4039806441034 5NA75800XG08
For SiCOMPACT A2 MIDI (for 5NA750…) 4039806440914 5NA75200XG08
4.30
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
SiSTELLAR® MAXI
The SiSTELLAR® MAXI for railways/tracks and shipping and, as a lighting system, enables wide luminaire spacing. In
routes in the SiSTELLAR® luminaire line of products with its addition, the luminaire can be individually adapted to the
precise optics fulfills the high demands in these special specific requirements in this lighting field. This is achieved by
security applications. Glare-free light distribution, high lighting the special construction of the lamp compartment, which has
intensities, and good color rendering and contrast are space for 6 light sources. They are fitted on their own
required. The SiSTELLAR® MAXI, with its highly illuminant supports with socket, electrical connection, and reflector
light sources and a flat cover panel as the optical enclosure bowl. By rotating this reflector system in increments of 30°
that minimizes light spill, fulfills these requirements. to 150°, various light distribution characteristics can be
achieved.
The SiSTELLAR® MAXI mast light enables mounting heights
of 10 to 16 meters, thus illuminating especially wide areas,
4.31
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
Features Housing
— no light spill: 0% light immission Housing and central canopy element made of sheet alu-
— large-area luminaire for high mounting heights minum with dripping edge, metallic gray textured (RAL 9007)
— adjustable SiVARIAL reflector technology for individually surface; central supporting frame for central mast connection
adjustable light distribution patterns made of steel, painted light gray (RAL 7035) | all-round wool-
— central supporting frame for mast connection felt gasket | 3-part segmented cover made of flat, tempera-
ture-resistant, toughened safety glass | insulation class: II |
Lighting technology protection rating: IP44
SiVARIAL reflector units with lamp sockets can be individually
rotated on-site in 15° increments | individual, application- Applications
optimized light distribution: Illumination is circular, rectangular, For glare-free lighting installations such as:
linear, x-shaped, asymmetric narrow, or asymmetric wide — railway systems and shipping routes, approved for Ger-
man Railways railway tracks (German rail system)
Electrical system — harbor facilities
Luminaire wired ready for connection | with 4-pole terminal, — container terminals, loading bays
max. 2.5mm² | lamps configured in 3 switching groups | — industrial facilities
electrical control components on central supporting frame,
access from above via central canopy element | tool-free
relamping
4.32
4 Luminaires for special applications | Luminaires for railways/tracks and shipping routes
0%
ø1500
280
365
ø108
Aw=0.47 m²
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1* Light source Order no. Order no.
OSRAM Siteco
with CCG and thermal protection, power-factor correction
6x HST 400 W E40 104.4 CCG 4039806251015 5NA650E6V
6x HSE 250 W E40 100.2 CCG 4039806250995 5NA650E6U
0RXQWLQJKHLJKWP7LOW
O[
P
4.33
Luminaires for special applications | Luminaires for railways/tracks and shipping routes 4
Suction pad
da Mounting information
Spigot: da x l = 108 to 118 x 280mm
l
4.34
4 Luminaires for special applications | Security luminaires
The Streetlight 10 midi LED security luminaire, with its state- LED operating electronics make available a high level of
of-the-art lighting technology and highly precise optics, fulfills efficiency potential. Luminous flux can be individually set
the high demands of security applications. The Streetlight 10 according to needs with performance packages “Plus” (with
LED sets the standard for outdoor LED luminaires developed the Siteco® Service Box) and “Premium” (with Street Light
completely for efficiency and lighting effects. A purist, Control).
functional design is combined with high-power LEDs and
outstanding lighting technology. As such, the Streetlight 10 The mechanical concept of the luminaire is also pioneering.
LED eminently complies with the requirements of DIN EN Both the optical module and the gear tray can be easily and
13201 for all S and M lighting classes. Due to the special rapidly replaced.
property of LED technology to immediately provide complete This means upgrading to higher performance, future LED
luminous flux – both directly after switch-on as well as after modules is easily implemented. This solution enables a
repeated switch-on actions – efficient lighting without sustainable and future-oriented use of the high-quality
warm-up time is ensured. The microprocessor-controlled luminaire housing.
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
4.35
Luminaires for special applications | Security luminaires 4
4.36
4 Luminaires for special applications | Security luminaires
0% 0°
800 386
68
168
Aw=0.07 m²
— please order the mast cable set separately for configuration of the “Plus” version with installed luminaire
— please order SLC light management components for the “Premium” version separately if required
Mounting height 8m
/LFKWSXQNWKÓKHP1HLJXQJ Tilt 0° — please order mast flange according to spigot diameter separately
O[
P
4.37
Luminaires for special applications | Security luminaires 4
4.38
4 Luminaires for special applications | Security luminaires
For parameterizing the operating electronics of all “Plus” version Siteco® LED road luminaires
| maximum energy efficiency via individual adaptation of lighting level, switching time, and
reduction level | setting of static colors and dynamic color sequences with suitable luminaires
| software* included with Service Box | with plug-in coupling for connecting Y-cable | plastic
housing; plug-in coupling with IP54 protection cap | insulation class II
— incl. Y-cable for looping the Service Box into luminaire supply cable | incl. workshop cable set for configuring the unmounted
luminaire in the workshop; safety plug on one end
*adoption of complete color sequences and software updates possible via PC | incl. mini USB interface for connection to PC
4.39
Luminaires for special applications | Security luminaires 4
Mast flange
For installing Streetlight 10 LED as a post-top or side-entry luminaire via twisting of mast
flange | luminaire inclination set via mast flange (0°, 5°, 10°, 15°) | various mast flanges for dif-
fering mast spigot diameters | mast flange made of diecast aluminum, light gray (RAL 7035)
— mast flange not included in luminaire delivery; please order mast flange separately according to mast spigot diameter
da
Mounting information for post-top mounting
l
Mast spigot: da x l = 76 x 100mm (luminaire mounting possible with mast flange type 76)
da x l = 60 x 100mm (luminaire mounting possible with mast flange type 60)
Mast spigot: da x l = 60 x 100mm (luminaire mounting possible with mast flange type 60)
da x l = 42 x 100mm (luminaire mounting possible with mast flange type 42)
For wiring of junction box in mast to luminaire, with “Plus” version | with 5-pole plug-in
coupling for integration of Siteco® Service Box, for manual configuration of luminaire (e.g.
luminous flux, timer, etc.)
Detailed information for intelligent control Masts, brackets, and special attachments
of Siteco® luminaires: Chapter 6 are specified in Chapter 7
4.40
4 Luminaires for special applications | Security luminaires
The SR 100 and SR 200 security luminaires from the SR Despite its robust construction and high (IP65) protection
luminaire range fulfills the high demands of security applica- rating, the SR luminaires are easy to handle: A central rotary
tions due to state-of-the-art lighting technology and very catch at the bottom of the luminaire secures the optical
precise optics. For this purpose, the luminaires are equipped enclosure and gear tray. The cover panel can be opened
with a high-voltage ignitor for re-ignition of the hot lamp fol- downwards by rotating the catch 180 degrees. A further
lowing power interruption (re-ignition time < 0.2 seconds). setting unlocks the gear tray with lamp socket and lamp that
This ensures that camera-monitored security areas can be can also be hinged downwards. The mechanism cuts off the
illuminated and filmed without interruption. power supply; maintenance and checks as well as tool-free
This task requires good, glare-free light distribution and a gear tray replacement can be carried out without danger.
high level of vertical lighting intensity. The SR luminaires solve
this task with high-luminance HIT or HST lamps and an opti-
cal enclosure in the form of a flat cover panel that minimizes
stray light. With a radial faceted reflector that optimally splits
the light point and that can be adjusted horizontally by simply
sliding, the luminaire generates wide asymmetric, glare-free
light distribution.
4.41
Luminaires for special applications | Security luminaires 4
Features Housing
— IP65 protection rating for lamp compartment and control Luminaire housing, support frame, and mast flange made of
gear compartment diecast aluminum, light gray (RAL 7035) | peripheral EPDM
— high-quality sealing system with air-permeable membrane seal in the housing profile | mast flange in 4 sizes for various
for optimal pressure equalization mast diameters, for post-top or side-entry mounting, for
— flat cover panel for minimal glare luminaire inclination 0°, 3°, 8°, or 15° | central rotary catch
— individually adjustable lighting technology via radial opens optical cover and control gear compartment | flat
faceted optics optical enclosure made of toughened safety glass with frame
— high luminaire light output ratio of fiberglass-reinforced polyester | pressure equalization sys-
— electrical unit replaced without tools tem with air-permeable membrane to prevent condensation
— central rotary catch in the housing | insulation class: I | protection rating: IP65
— adjustable inclination (0°, 3°, 8°, 15°)
Applications
Lighting technology For glare-free lighting installations:
Wide light distribution with high level of uniformity due to — airports
highly efficient radial faceted optics | variable light-band de- — interstates
flection via adjustable optics | high level of system efficiency — areas with video monitoring
in power classes up to 400W via system-optimized light — installations with security protection
distribution and large distances between luminaires | optical — security lighting for industrial facilities
enclosure is flat cover panel of toughened safety glass for
minimized light immission
Electrical system
Cover and control gear compartment can be opened without
tools and hinged downwards; automatic all-pole power
disconnection when control gear compartment hinged down-
wards | tool-free relamping | all electric components mounted
on removable gear tray; connection via plug-in coupling |
luminaire wired ready for connection, with 3-pole terminal,
max. 2.5mm² | with CCG, power-factor correction and ignitor
for instant hot re-ignition
4.42
4 Luminaires for special applications | Security luminaires
0% 0°
807 358
198
216
Aw=0.16 m²
SR 100
1$37
[+67 '(0)K://
Security luminaire | with radial faceted optics | with flat cover panel |
IOP with CCG and instant hot re-ignition (< 0.2 seconds)
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Post-top element, 3x diecast aluminum, spigot size: 76mm 6.5 4039806350480 5NA55103MA76
P
4.43
Luminaires for special applications | Security luminaires 4
0% 0°
870 358
198
216
Aw=0.18 m²
SR 200
1$67
[+67 '(K:)F
Security luminaire | with radial faceted optics | with flat cover panel |
IOP with CCG and instant hot re-ignition (< 0.2 seconds)
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Post-top element, 3x diecast aluminum, spigot size: 76mm 6.5 4039806350480 5NA55103MA76
P
4.44
4 Luminaires for special applications | Security luminaires
Mast flange
For mounting the SR luminaire as a post-top or side-entry luminaire by rotating the mast
flange | luminaire inclination set via mast flange (0°, 3°, 8°, 15°) | various mast flanges for dif-
fering mast spigot diameters | mast flange made of diecast aluminum, light gray (RAL 7035)
— mast flange not included in luminaire delivery; please order mast flange separately according to mast spigot diameter
da Typ 76 Typ 60
l
For mounting SR luminaires in 2x or 3x arrangement | luminaire inclination can be set via mast
flange (0°, 3°, 8°, 15°) | mast flange made of aluminum sand casting, light gray (RAL 7035)
spigot: da x l = 76 x 130mm
Detailed information for intelligent control Masts, brackets, and special attachments
of Siteco® luminaires: Chapter 6 are specified in Chapter 7
4.45
Luminaires for special applications | Security luminaires 4
Optical enclosure
flat cover panel, with frame
Frame made of GRP, light gray (RAL 7035); cover made of toughened safety glass
Two-part unit, consisting of ignitor and control unit | used as replacement for luminaires
already equipped with immediate hot re-ignition
Ignitor
HIT-DE-CRI 70/150W 0.4 4039806231987 5NZ41001ZEN
HST-DE 70/150/250/400W 0.4 4039806231987 5NZ41001ZEN
HIT-DE 150/250/400W 0.8 5NZ41001ZEH
Control unit
HST-DE 70/150/250/400W 0.2 4039806231970 5NZ41001SEN
HIT-DE 150/250/400W 0.2 5NZ41001SEH
Detailed information for intelligent control Masts, brackets, and special attachments
of Siteco® luminaires: Chapter 6 are specified in Chapter 7
4.46
4 Luminaires for special applications | Security luminaires
The SiCOMPACT® A2 MINI LED I … A2 MIDI LED luminaires cover panel ensure efficient light distribution. With horizontal
from the SiCOMPACT® floodlight line, with their state-of-the- alignment of the light emission aperture, the illuminated area
art lighting technology, fulfill the high demands of security can be lit such that less than 3% light spill is emitted to the
applications. Due to the special property of LED technology, upper hemisphere. The luminaires with mounting brackets
complete luminous flux is available immediately – both directly can be precisely adjusted in 5° increments for precise
after switch-on as well as after repeated switch-on actions. illumination of the application area. Integral twist protection
This ensures efficient lighting without warm-up time so that permanently affixes the luminaires.
uninterrupted video camera monitoring is also ensured.
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
4.47
Luminaires for special applications | Security luminaires 4
Electrical system
Luminaire wired ready for connection | with 3-pole terminal,
max. 2.5mm² (2-pole for power supply + 1-pole for 230V
control voltage for power reduction) | cable entry for cables
D = 6 to 12mm
4.48
4 Luminaires for special applications | Security luminaires
0% 0° 40
51 51
261
276
250
355
95
Aw=0.03 m²
196
SiCOMPACT® A2 MINI LED
;$/1$
with mounting bracket
[/('.&5,ƁI1OP
& &
/XPLQRXVLQWHQVLW\FODVV
DFFRUGLQJWR
(1*
Light source Order no. Order no.
OSRAM Siteco
wide distribution
LED > 5000 ≥ 80 2180 41 4.4 Basic 4050737012742 5XA7577LNA008
Mounting height 4m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
4.49
Luminaires for special applications | Security luminaires 4
565
0% 0°
102
230
465
420 155
348
Aw=0.08 m²
50
& &
Light source Order no. Order no.
/XPLQRXVLQWHQVLW\FODVV
OSRAM Siteco
DFFRUGLQJWR
(1* wide distribution
LED > 5000 ≥ 80 6600 98 15.3 ECG 4050737019666 5XA7587BNT008
Mounting height 6m
0RXQWLQJKHLJKWP7LOW Tilt 0°
O[
P
4.50
4 Luminaires for special applications | Security luminaires
The asymmetric SiCOMPACT® A2 MINI | … A2 MIDI lumi- adjusted in 5° increments for exact illumination of the
naires from the SiCOMPACT® floodlight line, with their state- application area. Integral twist protection permanently affixes
of-the-art lighting technology and precise optics, fulfill the the luminaires.
many requirements in security applications. With horizontal
alignment of the light emission aperture, the illuminated area High-performance double-ended HIT or HST lamps can be
can be lit such that less than 3% light spill is emitted to the used as light sources. Both construction sizes can be
upper hemisphere. A highly specular anodized aluminum equipped with an ignitor for instant hot re-ignition, enabling
reflector, which creates an asymmetric narrow (A2 MIDI) or the luminaire to be used in sports arenas and places of
asymmetric wide (A2 MINI, A2 MIDI) lighting effect, ensures competition and also in high-security areas.
efficient light distribution. The floodlights can be precisely
4.51
Luminaires for special applications | Security luminaires 4
4.52
4 Luminaires for special applications | Security luminaires
0% 0° 40
51 51
261
276
250
355
95
Aw=0.03 m²
196
SiCOMPACT® A2 MINI
1$36
[+67 '(0)K://
Security luminaire | asymmetric wide | with mounting bracket |
IOP with CCG and instant hot re-ignition
— please order cross arm separately if required
,PD[FGNOPDWJ
& &
0RXQWLQJKHLJKWP7LOW
O[
P
4.53
Luminaires for special applications | Security luminaires 4
565
0% 0°
440
230
465
102
420 155
348
Aw=0.08 m²
50
wide distribution
$& % 1x HST-DE 250 W Fc2 18.1 CCG 4039806616760 5NA75861SS0208
1x HST-DE 400 W Fc2 20.9 CCG 4039806616784 5NA75861TS0208
with separate control gear, with integrated ignitor (with hot re-ignition)
narrow distribution
1x HIT-DE 250 W Fc2 19.0 CCG 4039806616753 5NA75871RB0208
1x HIT-DE 400 W Fc2 21.4 CCG 4039806616814 5NA75871TB0208
/LFKWSXQNWKÓKHP1HLJXQJ
O[ wide distribution
1x HIT-DE 250 W Fc2 19.0 CCG 4039806616746 5NA75871RS0208
1x HIT-DE 400 W Fc2 21.4 CCG 4039806616807 5NA75871TS0208
— please order cross arm separately if required
P
4.54
4 Luminaires for special applications | Security luminaires
Ground stake
102
Steel, galvanized
60
V4A bracket
Straight bracket
4.55
Luminaires for special applications | Security luminaires 4
Cross-arm
da Mounting information
Mast spigot: da x l
l
b b
ø16 ø16 ø16
150
150
da da
ø16 ø16 ø14 ø14
62
62
b b1
1 2
Designation Fig. b (mm) b1 (mm) Mast spigot: Wt. Order no. OSRAM Order no. Siteco
da x l (mm) (kg)
— cross arm suitable for floodlight with max. weight: mmax = 1x 26kg or 2x 26kg
(please also note the static analysis and the permissible load limit of the mast)
4.56
4 Luminaires for special applications | Security luminaires
Visor
To reduce glare when viewing from the side | stainless steel, painted black (RAL 9005, matte)
Louvre shielding
To reduce glare when viewing from the side | stainless steel, painted black (RAL 9005, matte)
Galvanized steel and painted, white aluminum (RAL 9006) | grid spacing 47 x 22mm; steel
wire: d = 3mm
4.57
Luminaires for special applications | Security luminaires 4
Mast mounting element with single or multiple bracket | galvanized steel, coated Siteco®
metallic gray (DB 702S) | with 5NY75701XA …: Post-top mounting element of aluminum
Designation Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
da Mounting information
Mast spigot: da x l
l
a1 a2 a3 a4
b
c
da da da da
4.58
4 Luminaires for special applications | Security luminaires
Mast mounting element with multiple bracket | galvanized steel, coated Siteco® metallic gray
(DB 702S) | multiple bracket replaces the luminaire mounting bracket, luminaire connection to
the fixing points of the mounting bracket | adjustment of luminaire in 5° increments
Designation Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
da Mounting information
Mast spigot: da x l
l
a2 a3 a4
c
d2 d3 d4
4.59
Luminaires for special applications | Security luminaires 4
Wall adapter
Wall flange, cover, and adapter made of galvanized steel, coated Siteco® metallic gray
(DB 702S) | wall flange via supplementary cover without visible screws
Cover panel
For SiCOMPACT A2 MINI 4039806440938 5NA75700XG08
For SiCOMPACT A2 MIDI 4039806441034 5NA75800XG08
4.60
4 Luminaires for special applications | Luminaires for underpasses, underground parking garages, bus/train shelters, and stadium stand areas
TV 10
4.61
Luminaires for special applications | Luminaires for underpasses, underground parking garages, bus/train shelters, and stadium stand areas 4
l 260
70
x
TV 10
/$(
Individual luminaire for underpasses, underground parking garages, bus/train
[7:IOP
shelters, and stadium stand areas | luminaire to prevent vandalism
Anti-vandalism luminaire for ceiling surface Siteco® metallic gray (DB 702S) with
mounting cover panel of impact-resistant PC
— direct symmetric wide distribution — protection rating: IP65
— with ECG — insulation class: II
— housing baseplate made of extruded — impact resistance: 2x IK10
aluminum; cover of diecast aluminum,
10
FGNOP
T26
1x T26 36W G13 1315 700–1140 7.6 4039806598356 5LA86071C
1x T26 58W G13 1615 900–1440 8.6 4039806598363 5LA86071E
2x T26 36W G13 1315 700–1140 7.6 4039806598394 5LA86072C
2x T26 58W G13 1615 900–1440 9.3 4039806598400 5LA86072E
4.62
5 Spotlights and floodlights | Overview
21m
SiCOMPACT®
R3 MAXI
18m
Page 5.55
15m
12m
9m
6m
3m
5.1
Spotlights and floodlights | Overview 5
21m
18m
15m
SiCOMPACT®
FL MIDI S 12m
Page 5.43
9m
6m
3m
5.2
5 Spotlights and floodlights | Overview
5.3
Spotlights and floodlights | Overview 5
5.4
5 Spotlights and floodlights | Product search
Light source
— LED
— HIT/HIT-CE/HIT-DE/HIT-DE-CE -/-/¢/¢ ¢/-/¢/- ¢/¢/¢/- -/-/¢/- ¢/-/¢/- ¢/-/¢/-
— HST/HST-DE/HSE ¢/¢/- ¢/¢/- ¢/-/- ¢/¢/-/- ¢/¢/-/- ¢/-/-/-
— QT-DE11/12 ¢ ¢ ¢ ¢
— TC-TEL ¢
Insulation class I I I I I I
Applications
— industry ¢ ¢ ¢ ¢ ¢ ¢
— traffic ¢ ¢
— public ¢ ¢ ¢ ¢
— sports ¢ ¢ ¢ ¢ ¢ ¢
Lighting technology
— narrow ¢ ¢ ¢ ¢
— wide ¢ ¢ ¢ ¢ ¢
— LDC1…LDC7
— Optics for street lighting
Features
— integrated control unit ¢ ¢ ¢ ¢
— control unit to be ordered separately ¢ ¢
5.5
Spotlights and floodlights | Product search 5
¢
-/¢/-/- -/¢/-/- ¢/-/-/- -/-/¢/-
I I I I I
¢ ¢ ¢ ¢
¢ ¢ ¢
¢ ¢ ¢
¢ ¢ ¢ ¢ ¢
¢ ¢ ¢ ¢
¢ ¢ ¢ ¢
¢ ¢ ¢
5.6
5 Spotlights and floodlights | Floodlight with asymmetric distribution
SiCOMPACT® A2
Floodlights with asymmetric light distribution in the HST and QT lamps can be used as light source here. Apart
SiCOMPACT® A2 family in the construction sizes MINI and from that, there is an efficient LED system with street lighting
MIDI are suitable for both sophisticated architectural lighting optics available. To precisely illuminate the area of applica-
as well as for standard compliant and energy-efficient illumi- tion, the floodlights can be precisely adjusted in 5 degree
nation of large open spaces. With horizontal alignment of the increments. Integral twist protection permanently fixes the
light emission aperture, the area can be illuminated so that luminaire. Control gears and ignitors are integrated in the
there is less than three percent light spill to the upper luminaire and are fitted separately from the lamp compart-
hemisphere. A high gloss anodized aluminum mirror ensures ment. In addition to that there is the option of equipping the
efficient light distribution which as an option can achieve an floodlights with an ignitor for immediate hot ignition which
asymmetric narrow distribution or an asymmetric wide allows the use of luminaires in sports arenas and competition
distribution lighting effect. Different high performance HIT, venues as well as in areas with special security measures.
5.7
Spotlights and floodlights | Floodlight with asymmetric distribution 5
Features Electrics
— no light spill: light immission 0% with horizontal mounting Luminaire wired ready-to-use | with 3-pole
— efficient LED version with optics for street lighting connection terminal, max. 2.5mm² | cable entry for cable
— versatile installation options: a version with a mounting D = 6…12mm | depending on the version with ECG, with
bracket, a mast connection and for wall mounting CCG and ignitor, power-factor correction or with CCG and
— luminaire family with uniform design in 3 construction sizes ignitor for immediate hot re-ignition; all electrical components
— Siteco® Savelight components for greater safety, higher integrated in the luminaire housing (exception: Versions for
energy savings, longer lamp service life and lower HIT-DE/HST-DE 70W/150W with hot re-ignition and HIT-DE
maintenance costs 250W/400W with hot re-ignition → CCG in separate housing,
— luminaire cover made of safety glass with an all-round with hardwired cable to the floodlight, l = approx. 1.0m);
silicone seal; IP66 protection rating version of high voltage halogen lamp without control unit
— pressure equalization system with air-permeable
membrane prevents build-up of condensation in housing Housing
— low windage area: Aw = 0.03m² (MINI); 0.08m² (MIDI) Housing of diecast aluminum with side mounting bracket or
— protection against twisting with integrated ratchet mecha- rear housing connection for mast and wall adapter; mounting
nism, simple adjustment of floodlight in 5° increments bracket, wall and mast adapter made of galvanized steel; all
parts coated in Siteco® metallic gray (DB 702S) | an all-round
Lighting technology silicone seal in the housing profile | cover made of flat, tem-
Asymmetric light distribution, with horizontal light emission perature-resistant, toughened safety glass | mounting brack-
surface without light spill in the the upper atmosphere (light et with adjustment feature for floodlight, with ratchet mecha-
immission 0%) | Version with mounting bracket for precise nism adjustable in 5° increments, with twist protection |
alignment of the floodlight and precise delimitation of the lit pressure equalization system with air-permeable membrane
up area with a simple adjustment option, ratchet mechanism to avoid condensation in the housing | insulation class: I |
adjustable in 5° increments protection rating: IP66
— SiCOMPACT® A2 MINI with wide distribution
characteristics Applications
— SiCOMPACT® A2 MIDI with narrow or wide distribution — façade lighting
characteristics — illumination of sculptures
— arcade lighting
— plaza lighting
5.8
5 Spotlights and floodlights | Floodlight with asymmetric distribution
0% 0° 40
51 51
261
276
250
355
Multiwatt
95
Aw=0.03 m²
196
SiCOMPACT® A2 MINI
[+67'(0)K:φOP
asymmetric wide distribution | with mounting bracket
Floodlight with mounting bracket for re-ignition incl. separate control unit
mounting on a mast using a cross arm or a block, wired in the factory (cable l = 1m)
supporting structure — housing of diecast aluminum; bracket of
— with aluminum reflector, high gloss, galvanized steel; housing and bracket in
asymmetric wide distribution; with Siteco® metallic gray (DB 702S); cover of
transparent cover toughened safety glass
— with ECG or CCG, power-factor correction — protection rating: IP66
or as a version for a high voltage halogen — insulation class: I
FGNOP tubular lamp (without control unit); version — adjustment range: 10…350° (indoor
FGNOP
for high-pressure lamp optionally with hot installations: 0…360°)
10
with control unit, with ignitor installed (with hot re-ignition)
,PD[FGNOPEHLγ 1x HIT-DE-CE HST-DE 70 W RX7s 9.5 CCG 4039806625830 5NA75761NS0208
1x HIT-DE-CE HST-DE 150 W RX7s-24 10.0 CCG 4039806622952 5NA75761PS0208
& &
with integrated control unit, with integrated ignitor (with automatic power-off function)
1x HIT-DE HST-DE 70 W RX7s 6.0 CCG 4039806623942 5NA757E1NS0208
1x HIT-DE HST-DE 150 W RX7s-24 6.8 CCG 4039806623959 5NA757E1PS0208
1x HST 70 W E27 6.3 CCG 4039806626530 5NA757E1NS0108
P
5.9
Spotlights and floodlights | Floodlight with asymmetric distribution 5
687
40
250
0% 0°
444
189
Multiwatt
Aw=0.03 m²
Floodlight for mounting on a mast using a — housing with rear fixing of diecast alu-
mast bracket minum, Siteco® metallic gray (DB 702S);
— with aluminum reflector, high gloss, cover of toughened safety glass
asymmetric wide distribution; with — protection rating: IP66
transparent cover — insulation class: I
— with ECG or CCG, power-factor correc-
tion or as version for high voltage tubular
halogen lamp (without control unit)
FGNOP
FGNOP
Light source Order no. Order no.
OSRAM Siteco
without control unit, without ignitor
1x QT-DE 160/230 W R7s 3.8 - 4039806504289 5NA75701SS2208H
with integrated control unit, with integrated ignitor (with automatic power-off function)
1x HIT-DE | HST-DE 70 W RX7s 5.2 CCG 4039806626615 5NA757E1NS2208
1x HIT-DE | HST-DE 150 W RX7s-24 6.1 CCG 4039806626639 5NA757E1PS2208
,PD[FGNOPEHLγ 1x HST 70 W E27 5.3 CCG 4039806627650 5NA757E1NS2108
with ECG
1x HIT-DE 70 W RX7s 4.1 ECG 4039806427038 5NA75771NS2208
P
5.10
5 Spotlights and floodlights | Floodlight with asymmetric distribution
355
276
250
0% 0°
95
Multiwatt
Aw=0.03 m²
Floodlight for mounting on a mast using a — housing with side fixing of diecast alu-
special twin, triple or 4-fold mast bracket minum, Siteco® metallic gray (DB 702S);
— with aluminum reflector, high gloss, cover of toughened safety glass
asymmetric wide distribution; with — protection rating: IP66
transparent cover — insulation class: I
— with ECG or CCG, power-factor
correction
& &
Mandatory accessories (for details see page 5.18 ff.)
P
5.11
Spotlights and floodlights | Floodlight with asymmetric distribution 5
355
198
250
0% 0°
88
95
Multiwatt
409
Aw=0.03 m²
Floodlight for wall mounting using wall — housing with rear fixing of diecast alu-
adapter minum, Siteco® metallic gray (DB 702S);
— with aluminum reflector, high gloss, cover of toughened safety glass
asymmetric wide distribution; with — protection rating: IP66
transparent cover — insulation class: I
— with ECG or CCG, power-factor — can also be used as uplight for indoor
correction or as version for high voltage applications
tubular halogen lamp (without control
FGNOP unit)
FGNOP
with integrated control unit, with integrated ignitor (with automatic power-off function)
1x HIT-DE | HST-DE 70 W RX7s 5.2 CCG 4039806626615 5NA757E1NS2208
,PD[FGNOPEHLγ 1x HIT-DE | HST-DE 150 W RX7s-24 6.1 CCG 4039806626639 5NA757E1PS2208
1x HST 70 W E27 5.3 CCG 4039806627650 5NA757E1NS2108
& &
with ECG Multiwatt
1x TC-TEL 26/32/42 W GX24q-3/-4 4.0 Multi 4039806626578 5LA75771TS2108
with ECG
1x HIT-DE 70 W RX7s 4.1 ECG 4039806427038 5NA75771NS2208
— please order wall adapter separately
/LFKWSXQNWKÓKHP1HLJXQJ
O[
Mandatory accessories (for details see page 5.18 ff.)
Designation Wt. (kg) Order no. Order no.
OSRAM Siteco
Wall bracket 0.7 4039806455413 5NY75701XW2108
P
5.12
5 Spotlights and floodlights | Floodlight with asymmetric distribution
565
440
230
465
102
420
0% 0°
155
348
Aw=0.08 m²
50
Floodlight with mounting bracket for separate control unit block, wired in the
mounting on a mast using a cross arm or a factory (cable l = 1.3m)
supporting structure — housing of diecast aluminum; bracket of
— with aluminum reflector, high gloss, galvanized steel; housing and bracket in
asymmetric narrow or wide distribution; Siteco® metallic gray (DB 702S); cover of
with transparent cover toughened safety glass
— with ECG or CCG, power-factor — protection rating: IP66
correction or as a version for a high — insulation class: I
voltage halogen tubular lamp (without — adjustment range: 10…350° (indoor
FGNOP control unit); version for high-pressure installations: 0…360°)
FGNOP
lamp optionally with hot re-ignition incl.
10
Light source Order no. Order no.
OSRAM Siteco
narrow distribution
without control unit, without ignitor
1x QT-DE 1000 W R7s 12.7 - 4039806614872 5NA75801VB0208H
,PD[FGNOP7LOW
with integrated control unit, with integrated ignitor (with automatic power-off function)
1x HIT | HST 250 W E40 16.7 CCG 4039806623737 5NA758E1SB0108
$& %
1x HIT | HST 400 W E40 18.2 CCG 4039806623751 5NA758E1TB0108
1x HIT-DE 250 W Fc2 17.7 CCG 4039806623775 5NA758E1RB0208
1x HIT-DE | HST-DE 400 W Fc2 18.1 CCG 4039806623744 5NA758E1TB0208
1x HST-DE 250 W Fc2 16.6 CCG 4039806623720 5NA758E1SB0208
with integrated control unit, with integrated ignitor (with hot re-ignition)
1x HST-DE 250 W Fc2 18.1 CCG 4039806616777 5NA75861SB0208
1x HST-DE 400 W Fc2 20.9 CCG 4039806616791 5NA75861TB0208
0RXQWLQJKHLJKWP7LOW
O[
with separate control unit, with ignitor installed (with hot re-ignition)
1x HIT-DE 250 W Fc2 19.0 CCG 4039806616753 5NA75871RB0208
1x HIT-DE 400 W Fc2 21.4 CCG 4039806616814 5NA75871TB0208
P
5.13
Spotlights and floodlights | Floodlight with asymmetric distribution 5
with integrated control unit, with integrated ignitor (with automatic power-off function)
1x HIT | HST 250 W E40 16.7 CCG 4039806623690 5NA758E1SS0108
1x HIT | HST 400 W E40 18.2 CCG 4039806623713 5NA758E1TS0108
1x HIT-DE 250 W Fc2 17.7 CCG 4039806623768 5NA758E1RS0208
1x HIT-DE | HST-DE 400 W Fc2 18.1 CCG 4039806623706 5NA758E1TS0208
1x HST-DE 250 W Fc2 16.6 CCG 4039806623683 5NA758E1SS0208
with integrated control unit, with integrated ignitor (with hot re-ignition)
1x HST-DE 250 W Fc2 18.1 CCG 4039806616760 5NA75861SS0208
1x HST-DE 400 W Fc2 20.9 CCG 4039806616784 5NA75861TS0208
with separate control unit, with integrated ignitor (with hot re-ignition)
1x HIT-DE 250 W Fc2 19.0 CCG 4039806616746 5NA75871RS0208
1x HIT-DE 400 W Fc2 21.4 CCG 4039806616807 5NA75871TS0208
5.14
5 Spotlights and floodlights | Floodlight with asymmetric distribution
998
565
420
0% 0°
60
Aw=0.08 m²
501
155
246
SiCOMPACT® A2 MIDI
1$(7%
asymmetric narrow or wide distribution | for mast bracket, rear fixing
[+,7 K:FIOP
Floodlight for mounting on a mast using a — housing with rear fixing of diecast alu-
mast bracket minum, Siteco® metallic gray (DB 702S);
— with aluminum reflector, high gloss, cover of toughened safety glass
asymmetric narrow or wide distribution; — protection rating: IP66
with transparent cover — insulation class: I
— with CCG, power-factor correction
10
0RXQWLQJKHLJKWP7LOW
O[
Mandatory accessories (for details see page 5.18 ff.)
P
5.15
Spotlights and floodlights | Floodlight with asymmetric distribution 5
565
465
420
0% 0°
155
Aw=0.08 m²
Floodlight for mounting on a mast using a — housing with side fixing of diecast alu-
special twin, triple or 4-fold mast bracket minum, Siteco® metallic gray (DB 702S);
— with aluminum reflector, high gloss, cover of toughened safety glass
asymmetric narrow or wide distribution; — protection rating: IP66
with transparent cover — insulation class: I
— with CCG, power-factor correction
0RXQWLQJKHLJKWP7LOW
O[
Mandatory accessories (for details see page 5.18 ff.)
P
5.16
5 Spotlights and floodlights | Floodlight with asymmetric distribution
565
0% 0°
420
155
153
Aw=0.08 m²
678
Floodlight for wall mounting using wall — housing with rear fixing of diecast alu-
adapter minum, Siteco® metallic gray (DB 702S);
— with aluminum reflector, high gloss, cover of toughened safety glass
asymmetric narrow or wide distribution; — protection rating: IP66
with transparent cover — insulation class: I
— with CCG, power-factor correction — in indoor areas: can also be used as
uplight
10
FGNOP
FGNOP
P
5.17
Spotlights and floodlights | Floodlight with asymmetric distribution 5
Light visor
To reduce glare when viewing from the side | stainless steel, painted black (RAL 9005, matt)
multileaf collimator
To reduce glare when viewing from the side | stainless steel, painted black (RAL 9005, matt)
Galvanized steel, coated, white aluminum (RAL 9006) | mesh size 47 x 22 mm; steel wire:
d = 3mm)
5.18
5 Spotlights and floodlights | Floodlight with asymmetric distribution
Ground stake
102
V4A bracket
Straight bracket
to replace standard mounting bracket | galvanized steel, coated Siteco® metallic gray (DB
702S)
148
5.19
Spotlights and floodlights | Floodlight with asymmetric distribution 5
Mast mounting element with single or multiple bracket | galvanized steel, coated Siteco®
metallic gray (DB 702S) | with 5NY75701XA …: Mast mounting element of aluminum
Designation Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
da Mounting information
Mast spigot: da x l
l
a1 a2 a3 a4
b
c
da da da da
5.20
5 Spotlights and floodlights | Floodlight with asymmetric distribution
Mast mounting element with multiple bracket | galvanized steel, coated Siteco® metallic gray
(DB 702S) | multiple bracket replaces the luminaire mounting bracket, luminaire connection to
the fixing points of the mounting bracket | adjustment of luminaire in 5° steps
Designation Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
da Mounting information
Mast spigot: da x l
l
a2 a3 a4
c
d2 d3 d4
Wall adapter
Wall flange, cover and adapter of galvanized steel, coated in Siteco® metallic gray (DB 702S) |
wall flange via supplementary cover without visible screws
5.21
Spotlights and floodlights | Floodlight with asymmetric distribution 5
Cross-arm
da Mounting information
Mast spigot: da x l
l
b b
ø16 ø16 ø16
150
150
da da
ø16 ø16 ø14 ø14
62
62
b b1
Fig. 1 Fig. 2
Designation Fig. b (mm) b1 (mm) Mast spigot: Wt. (kg) Order no. OSRAM Order no. Siteco
da x l (mm)
— cross arm suitable for floodlight with a max. weight of max = 1x 26kg or 2 x 26 kg (please also observe the static analysis and
permissible upper load limit for the mast)
Cover panel
For SiCOMPACT® A2 MINI 4039806440938 5NA75700XG08
For SiCOMPACT® A2 MIDI 4039806441034 5NA75800XG08
5.22
5 Spotlights and floodlights | Floodlight with asymmetric distribution
SiCOMPACT® A3 MAXI
5.23
Spotlights and floodlights | Floodlight with asymmetric distribution 5
Features Electrics
— optimized reflector geometry for highly uniform illumination Luminaire wired ready for connection | with 3-pole connec-
— luminaire cover of toughened safety glass tion terminal (2-lamp version: 2x 3-pole connection terminal;
with high transmission factor version for immediate hot re-ignition: 4-pole connection ter-
— no light spill: light immission 0% with horizontal mounting minal), max. 2,5mm² | cable entry for cable D = 6…12mm |
— pressure equalization port prevents build-up of luminaire for separate control unit unit; ignitor or respectively
condensation in housing ignitor for immediate hot re-ignition integrated in luminaire
— low windage area: 0.13 m² housing | all-pole power disconnection upon opening the
— protection against twisting with integrated ratchet mecha- housing | individual switching possible with twin lamp ver-
nism, simple adjustment of floodlight in 5° increments sions
5.24
5 Spotlights and floodlights | Floodlight with asymmetric distribution
0% 0°
620
160
795 630
607 561
228
435
Aw=0.13 m²
60 63
wide distribution
without control unit, with mounted ignitor
1x HIT | HST 1000 W E40 21.9 - 4050737068381 5NA76901VS01
2x HIT-CE 400 W G22 22.6 - 4050737070483 5NA76902VS04
0RXQWLQJKHLJKWP7LOW 1x HIT-DE (l = 274) 2000 W K12s-36 22.1 - 4050737070469 5NA76901WS03
O[
1x HIT-DE (l = 187) 1000 W K12s-36 22.1 - 4050737070407 5NA76901VS02
1x HIT-DE (l = 187) 2000 W K12s-36 22.1 - 4050737070445 5NA76901WS02
1x HST 600 W E40 21.9 - 4050737070520 5NA76901US01
without control unit, with mounted ignitor (with hot re-ignition)
1x HIT-DE (l = 187) 1000/2000 W K12s-36 23.4 - 4050737070742 5NA76971WS02
— please order control unit separately
— please order cross arm separately if required
P
5.25
Spotlights and floodlights | Floodlight with asymmetric distribution 5
5.26
5 Spotlights and floodlights | Floodlight with asymmetric distribution
b Cross-arm
ø16
da
Mounting information
Mast spigot: da x l
l
da
ø21
Designation b (mm) Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
62
— cross arm suitable for floodlight with a max. weight of max = 1x 30kg (please also observe the static analysis and permissible
upper load limit for the mast)
Mast with cross arm for 1 or 2 floodlights | conical round mast divided in two, plug and stack
assembly | with 1 or 2 mast doors to install the control unit unit in the mast | with climbing
15600
2x150x50
Designation Recommended Wt. (kg) Order no. OSRAM Order no. Siteco
mounting height (m)
1500
ø269
Mast with single cross arm 16 335 4039806854841 5NY75901MS1
Mast with twin cross arm 16 370 4039806857736 5NY75902MS1
Control units
to be mounted on the wall, in the switchgear cabinet, to supporting structure or in masts with
appropriate dimensions in a canopied outdoor area | compact unit to operate a projector;
with control unit with compensating capacitor | with or without fuse | wired ready for connec-
tion with connection terminal 9-pole max. 6mm² | cable entry for cables D = 8…13.5mm |
encapsulated in cast resin, black; floor plate with 2 attachment points
protection rating: IP65 | insulation class: I
95 l
l1
115
20
Designation Lamp cur- Mains voltage l (mm) l1 (mm) Wt. Order no. OSRAM Order no. Siteco
rent (A) (V) (kg)
Control unit
94.5 l
l1
115
88
Designation Lamp cur- Mains volt- l (mm) l1 (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
rent (A) age (V)
5.28
5 Spotlights and floodlights | Floodlight with symmetric distribution
SiCOMPACT® S2
5.29
Spotlights and floodlights | Floodlight with symmetric distribution 5
Features Housing
— luminaire family in uniform design and two construction Housing of diecast aluminum with side mounting bracket of
sizes galvanized steel; housing and mounting bracket in Siteco®
— pressure equalization system with air-permeable metallic gray (DB 702S) | an all-round silicone seal in housing
membrane for condensation avoidance profile | cover of flat, temperature-resistant, toughened safety
— protection against twisting with integrated ratchet mecha- glass | mounting bracket with adjustment feature for flood-
nism, simple adjustment of floodlight in 5° increments light, ratchet mechanism adjustable in 5° increments, with
twist protection | pressure equalization system with air-
Lighting technology permeable membrane for condensation avoidance in the
Symmetrical light distribution with narrow or wide distribution housing | insulation class: I | protection rating: IP66
characteristics | mounting bracket for precise alignment of
the floodlight with simple adjustment option, ratchet Applications
mechanism in 5° increments — façade lighting
— illumination of sculptures
Electrics — arcade lighting
Luminaire wired and ready-to-use | with 3-pole connection — plaza lighting
terminal, max. 2.5 mm² | cable entry for cable D = 6…12mm
| depending on version with ECG, with CCG and ignitor, power-
factor correction or with CCG and ignitor for immediate hot
re-ignition; all electrical components integrated into the lumi-
naire housing (exception: Version with hot re-ignition → CCG
in separate housing, with hard-wired cable to floodlight,
l = 1.3m); version for high voltage halogen lamp without
control unit
5.30
5 Spotlights and floodlights | Floodlight with symmetric distribution
0% 0°
565
440
230
465
420
102
155
Aw=0.24 m²
348
50
Floodlight with mounting bracket for separate control unit block, wired in the
mounting on a mast using a cross arm or a factory (cable l = 1m)
supporting structure — housing of diecast aluminum; bracket of
— with aluminum reflector, high gloss, galvanized steel; housing and bracket in
symmetric narrow or wide distribution; Siteco® metallic gray (DB 702S); cover of
with transparent cover toughened safety glass
— with ECG or CCG, power-factor correc- — protection rating: IP66
tion or as a version for a high voltage — insulation class: I
halogen tubular lamp (without control — adjustment range: 10…350° (indoor
unit); version for high-pressure lamp installations: 0…360°)
,PD[FGNOPDWJ optionally with hot re-ignition incl.
10
& &
D [ [
D [ [
with integrated control unit, with integrated ignitor (with automatic power-off function)
1x HIT | HST 250 W E40 16.0 CCG 4039806623799 5NA752E1SB0108
1x HIT | HST 400 W E40 17.2 CCG 4039806623829 5NA752E1TB0108
1x HIT-DE 250 W Fc2 16.0 CCG 4039806623805 5NA752E1RB0208
1x HIT-DE | HST-DE 400 W Fc2 19.3 CCG 4039806623812 5NA752E1TB0208
1x HST-DE 250 W Fc2 17.4 CCG 4039806623782 5NA752E1SB0208
with separate control unit, with integrated ignitor (with hot re-ignition)
1x HIT-DE 250 W Fc2 19.0 CCG 4039806442833 5NA75271RB0208
1x HIT-DE 400 W Fc2 20.9 CCG 4039806442840 5NA75271TB0208
0RXQWLQJKHLJKWP7LOW 1x HST-DE 250 W Fc2 19.2 CCG 4039806442826 5NA75261SB0208
O[
1x HST-DE 400 W Fc2 15.1 CCG 4039806622846 5NA75261TB0208
P
5.31
Spotlights and floodlights | Floodlight with symmetric distribution 5
with integrated control unit, with integrated ignitor (with automatic power-off function)
1x HIT | HST 250 W E40 16.0 CCG 4039806623843 5NA752E1SS0108
1x HIT | HST 400 W E40 17.2 CCG 4039806623874 5NA752E1TS0108
1x HIT-DE 250 W Fc2 16.0 CCG 4039806623850 5NA752E1RS0208
1x HIT-DE | HST-DE 400 W Fc2 19.3 CCG 4039806623867 5NA752E1TS0208
1x HST-DE 250 W Fc2 17.4 CCG 4039806623836 5NA752E1SS0208
with separate control unit, with integrated ignitor (with hot re-ignition)
1x HIT-DE 250 W Fc2 19.0 CCG 4039806617637 5NA75271RS0208
1x HIT-DE 400 W Fc2 20.9 CCG 4039806617644 5NA75271TS0208
1x HST-DE 250 W Fc2 19.2 CCG 4039806619365 5NA75261SS0208
1x HST-DE 400 W Fc2 15.1 CCG 4039806621696 5NA75261TS0208
5.32
5 Spotlights and floodlights | Floodlight with symmetric distribution
0% 0°
355
51 51
250
261
276
95
184
Aw=0.08 m²
40
& &
Light source Order no. Order no.
D [ [
D [ [ OSRAM Siteco
without control unit, without ignitor
1x QT-DE 160/230 W R7s 4.5 - 4039806623102 5NA75101SS0208H
with integrated control unit, with integrated ignitor (with automatic power-off function)
1x HIT-DE | HST-DE 70 W RX7s 6.4 CCG 4039806623904 5NA751E1NS0208
1x HIT-DE | HST-DE 150 W RX7s-24 6.9 CCG 4039806623911 5NA751E1PS0208
1x HST 70 W E27 6.0 CCG 4039806402172 5NA751E1NS0108
with ECG
1x HIT-DE 70 W RX7s 4.3 ECG 4039806623041 5NA75171NS0208
0RXQWLQJKHLJKWP7LOW
O[
P
5.33
Spotlights and floodlights | Floodlight with symmetric distribution 5
to reduce glare when viewing from the side | stainless steel, painted black (RAL 9005, matt)
galvanized steel, coated, white aluminum (RAL 9006) | mesh size 47 x 22mm; steel wire:
d = 3mm
5.34
5 Spotlights and floodlights | Floodlight with symmetric distribution
Ground stake
102
steel, galvanized
60
V4A bracket
Straight bracket
to replace standard mounting bracket | galvanized steel, coated Siteco® metallic gray
(DB 702S)
148
5.35
Spotlights and floodlights | Floodlight with symmetric distribution 5
Cross-arm
da Mounting information
Mast spigot: da x l
l
b b
ø16 ø16 ø16
150
150
da da
ø16 ø16 ø14 ø14
62
62
b b1
1 2
Designation Fig. b (mm) b1 (mm) Mast spigot: Wt. (kg) Order no. Siteco
da x l (mm) OSRAM order no.
— cross arm suitable for floodlight with a max. weight of max = 1x 26kg or 2 x 26 kg (please also observe the static analysis and
permissible upper load limit for the mast)
Cover panel
For SiCOMPACT S2 MINI 4039806402158 5NA75100XG08
For SiCOMPACT S2 MIDI 4039806440914 5NA75200XG08
5.36
5 Spotlights and floodlights | Floodlight with symmetric distribution
SiCOMPACT® S2 MAXI
5.37
Spotlights and floodlights | Floodlight with symmetric distribution 5
Features Housing
— bifocal reflector system for glare reduction and uniform 2-part housing of diecast aluminum with side mounting
illumination bracket or rear housing connection for wall adapter; mount-
— protection against twisting with integrated ratchet mecha- ing bracket and wall adapter of galvanized steel; all parts
nism, simple adjustment of floodlight in 2.5° increments coated in Siteco® metallic gray (DB 702S) | an all-round
— pressure equalization system with air-permeable mem- silicone seal in the housing profile | cover of flat, temperature-
brane for condensation avoidance resistant, toughened safety glass | mounting bracket with
adjustment feature for floodlight, adjustment in 5° increments,
Lighting technology with twist protection | pressure equalization system with
Symmetric light distribution with narrow or wide distribution air-permeable membrane for condensation avoidance in the
characteristics | with bifocal optics for even illumination of housing | insulation class: I | protection rating: IP65
areas close to and far away from the mast | mounting brack-
et for precise alignment of the floodlight with simple adjust- Applications
ment options, ratchet mechanism in 2.5° increments | high — sports facility lighting
efficiency and low stray light | optional sighting device for pre- — plaza lighting
cise alignment of the projector to predetermined set points — façade lighting
Electrics
Luminaire wired ready for connection | connection box on
mounting bracket with 3-pole connection terminal (version for
immediate hot re-ignition and twin lamp version: 4-pole
connection terminal), max. 2.5mm² | cable entry for cable
D = 6…12mm | luminaire for separate control unit, ignitor or
respectively ignitor for immediate hot re-ignition integrated in
the luminaire housing | all-pole power disconnection upon
opening the housing | with twin lamp versions, individual
switching possible
5.38
5 Spotlights and floodlights | Floodlight with symmetric distribution
690 403
601
452
325
60
397
160
355 Aw=0.25 m²
,PD[FGNOPDWJ
& &
Light source Order no. Order no.
D [ [
D [ [ OSRAM Siteco
narrow distribution
without control unit, with mounted ignitor
1x HIT-DE l = 187 1000 W K12s-36 19.8 - 4039806210029 5NA75301VB02
1x HIT-DE l = 187 2000 W K12s-36 21.7 - 4039806210104 5NA75301WB02
wide distribution
without control unit, with mounted ignitor
1x HIT | HST 1000 W E40 19.7 - 4039806210043 5NA75301VS01
2x HIT | HST 250/400 W E40 21.0 - 4039806210166 5NA75302TS01
1x HIT-DE l = 187 1000 W K12s-36 19.8 - 4039806210067 5NA75301VS02
1x HIT-DE l = 187 2000 W K12s-36 21.7 - 4039806210142 5NA75301WS02
P
5.39
Spotlights and floodlights | Floodlight with symmetric distribution 5
5.40
5 Spotlights and floodlights | Floodlight with symmetric distribution
made of aluminum, black | to screw onto spotlight | for precise alignment of spotlights to
specified set points
da
Mounting information
da Mast spigot: da x l
l
ø21
Designation b (mm) Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
62
— cross arm suitable for floodlight with a max. weight of max = 1x 30kg (please also observe the static analysis and permissible
upper load limit for the mast)
Control units
to be mounted on the wall, in the switchgear cabinet, to supporting structure or in masts with
appropriate dimensions | to operate a projector; with control unit with compensating capacitor |
with or without fuse | wired ready for connection with connection terminal 9-pole max. 6mm² |
cable entry for cables D = 8…13.5mm | encapsulated in cast resin, black; floor plate with 2
attachment points
protection rating: IP65 | insulation class: I
95 l
l1
115
20
Designation Lamp cur- Mains voltage (V)l (mm) l1 (mm) Wt. OSRAM Siteco
rent (A) (kg) order no. order no.
Power-factor correction,
IP65
HIT/HST 2x 250W 3.0 230 524 495 15.5 4039806854254 5NA77922VR3
HIT/HST 2x 400W 4.4 230 524 495 15.5 4039806854261 5NA77922VR4
HIT/HIT-DE 1000W 9.5 220/230/240 524 495 15.5 4039806848482 5NA77921VR0
HIT-DE 2000W/D/S 10.3 380/400/420 599 570 20.5 4039806848499 5NA77921VR10
HST 1000W 10.3 220/230/240 524 495 15.5 4039806848505 5NA77921VR11
5.41
Spotlights and floodlights | Floodlight with symmetric distribution 5
Control unit
94.5 l
l1
115
88
Designation Lamp cur- Mains voltage (V)l (mm) l1 (mm) Wt. OSRAM Siteco
rent (A) (kg) order no. order no.
Cover panel
For SiCOMPACT S2 MAXI 4039806209313 5NA75300XG08
For SiCOMPACT S2 MIDI 4039806440914 5NA75200XG08
5.42
5 Spotlights and floodlights | Floodlight with symmetric distribution
SiCOMPACT® FL MIDI
The SiCOMPACT® FL MIDI family features extremely high effi- Thanks to DALI, the floodlight can be individually controlled
ciency and good light quality. Because the SiCOMPACT® FL and can be infinitely dimmed. This enables the most cost-
MIDI LED spotlight has been developed for the special re- efficient lighting possible, even for non sports events in multi-
quirements made by TV sports recordings with HD quality. functional arenas. All in all, the floodlight is oriented towards
The LED floodlight enables flicker.free and therefore HD-TV performance and functionality. LEDs, housing and optical
quality light, even for HD super slow motion and high-speed systems are precisely synchronized with each other to
recording at up to 1000 frames per second. The LED flood- provide fully efficient system control, a long lifespan and high
light is therefore suitable as an efficient solution for demand- quality light for all requirements made of multifunction sports
ing, lighting tasks in indoor sporting facility lighting. It facilities.
provides extremely even, glare-minimized light for comfort-
able viewing by both the athletes and the spectators.
Rapid advances in LED technology lead to permanent improvements in energy efficiency. This has the result that luminous flux or power consumption can also change
correspondingly. The latest values can be found in the photometric test report for the specific products and in the current download files of the photometric planning data.
5.43
Spotlights and floodlights | Floodlight with symmetric distribution 5
Features Housing
— optimum light for super slow motion LED module carrier with cooling ribs and electrics module of
— modular concept in 2 wattages diecast aluminum, mounting bracket of steel; bracket and
— integration with light management systems e-box coated in Siteco® metallic gray (DB 702S); side
— integrated or external E-box support profiles of anodized aluminum; cover made of PC |
— good color reproduction ball impact resistant | up to 50,000h lifespan at +40°C
— suitable for ambient temperatures of -20°C to +40°C
Applications
Lighting technology — multifunction halls
— symmetric distribution lens system — material testing (super slow motion)
— transmission angle semi-narrowing — HDTV recordings
— good color rendering with CRI > 80 — sports halls
— color temperature 5,000K
— cover made of impact-resistant PC
Electrics
Luminaire wired ready for connection, completely pre-mount-
ed with connection plug and enclosed socket with 5-pole
connection terminal (ECG DALI: 3-pole + 2-pole for control
signal), max. 4mm² | socket for cables D = 14…18mm | lumi-
naire with ECG DALI; depending on version with integrated
E-module or separate E-module
5.44
5 Spotlights and floodlights | Floodlight with symmetric distribution
442 92
375
604
60
160
Aw=0.26 m²
199
,PD[FGNOPDWJ
& &
D [ [
Light source Order no. Order no.
D [ [
OSRAM Siteco
LED 5000 ≥ 80 10400 150 19.7 ECG 4050737470580 5XA7621E1D00
0RXQWLQJKHLJKWP7LOW
O[
P
5.45
Spotlights and floodlights | Floodlight with symmetric distribution 5
400
810
1500
92
194
1500
439
92
194
375
Aw=0.18 m²
60
160 404
Floodlight with mounting bracket for e-box coated in Siteco® metallic gray
mounting on a mast using a cross arm or a (DB 702S); side support profiles of
supporting structure aluminum, anodized; cover of PC
— with lens system, narrow distribution — protection rating: IP65
— separate electric module; with connection — insulation class: I
cable fitted on luminaire side with plug — temperature range: -20°C…+40°C
connection to E-module, l = 1.5m — lifespan: up to 50,000h (L70 | B10)
— LED module carrier with cooling ribs and — ball impact resistant luminaire; inspected
electrics module of diecast aluminum, according to DIN VDE 0710, part 13
mounting bracket of steel; bracket and
,PD[FGNOPDWJ
& &
D [ [
D [ [
Light source Order no. Order no.
OSRAM Siteco
LED 5000 ≥ 80 20800 300 28.5 ECG 4050737583044 5XA7641E2D00
LED 5000 ≥ 80 10400 150 20.1 ECG 4050737583020 5XA7621E2D00
0RXQWLQJKHLJKWP7LOW
O[
P
5.46
5 Spotlights and floodlights | Spotlight with rotation symmetric distribution
SiCOMPACT® R1 MINI
The small, rotation symmetrical distribution spotlights in the on the wall, on mast carriers or cross-arms. High gloss alu-
SiCOMPACT® R1 MINI family are perfectly suited for illumi- minum reflectors with narrow or wide light distribution can be
nating horizontal areas within the context of sophisticated selected for various photometric tasks. Special effects are
architectural lighting. They are given great flexibility with the achieved with various color and diffuser discs.
associated accessories which can be used to mount them
Features Electrics
— small spotlight for illumination and architectural lighting Luminaire wired ready for connection | with 3-pole
— compact diecast aluminum housing with narrow or wide connection terminal, max. 2.5mm² | cable entry for cable
light distribution D = 7…14mm; optional protective tubing for cable to pro-
— with pressure equalization port preventing condensation in jector | with integral ballast (CCG, with parallel power-factor
housing correction), spatially separated from lamp compartment
— high light output ratio with compact design
— all electrical components integrated in housing Housing
Housing of diecast aluminum; mounting bracket of galva-
Lighting technology nized steel (SiCOMPACT® R1 MINI-S) or diecast aluminum
Highly specular aluminum reflector with rotationally symmetric (SiCOMPACT® R1 MINI-ALU); all parts coated in Siteco®
light distribution, narrow or wide; ellipsoid, diamond-shaped metallic gray (DB 702S) | luminaire cover of toughened safety
or diffuse light distribution via supplementary filter disc, color glass | pressure equalization system with air-permeable
accenting possible via dichroic color filters membrane for condensation avoidance in the housing |
insulation class: I | protection rating: IP65
5.47
Spotlights and floodlights | Spotlight with rotation symmetric distribution 5
264
165
222
SiCOMPACT® R1 MINI-S
1;(+6
rotationally symmetric very narrow or wide distribution | with mounting bracket
[+,7 &(:FIOP
FGNOP
,PD[FGNOPDWJ
5.48
5 Spotlights and floodlights | Spotlight with rotation symmetric distribution
236
ø198
ø168
330
450
293
37
ø120
,PD[FGNOPDWJ
5.49
Spotlights and floodlights | Spotlight with rotation symmetric distribution 5
for retrospective mounting | structured glass with supporting frame of aluminum, Siteco®
metallic gray (DB 702S)
Ribbed disc: ribbed structure creates ellipsoid light distribution
Pyramid disc: Pyramid structure generates diamond-shaped light distribution
diffuser disc: irregular surface structure creates diffuse light distribution
for retrofitting | very intensive color rendering due to improved filter characteristics with less
heating up of glass (compared to conventional filter glass) | for color accenting of facades and
paths | color filter of toughened safety glass; supporting frame of aluminum, Siteco® metallic
gray (DB 702S)
for retrofitting | for color accenting of facades and paths | color filter of toughened safety
glass; supporting frame of aluminum, Siteco® metallic gray (DB 702S)
Baffle ring
for glare limitation when viewed directly | galvanized, coated black (RAL 9005, matt)
5.50
5 Spotlights and floodlights | Spotlight with rotation symmetric distribution
Protection tube
to protect the cable to the spotlight | plastic, black | screw fastening on luminaire side | length
l = 600 mm; diameter: d i = 17 mm
Ground stake
102
steel, galvanized
60
Cross-arm, galvanized
for mounting two spotlights | cross arm of steel, galvanized | for spigot size da = 76 x 100
mm; cross arm L x W = 500 x 120 mm
5.51
Spotlights and floodlights | Spotlight with rotation symmetric distribution 5
Wall bracket
for mounting spotlight | wall bracket of diecast aluminum, Siteco® metallic gray (DB 702S)
flat cover panel, mounted in housing ring | cover of toughened safety glass; housing ring of
diecast aluminum, Siteco® metallic gray (DB 702S)
5.52
5 Spotlights and floodlights | Spotlight with rotation symmetric distribution
Siteco Mirrortec®
The rotationally symmetric Siteco Mirrortec® projector is The compact projector is manufactured of high quality die-
characterized by a high light output ratio and narrow light cast aluminum for easy handling: the projector head and
distribution without light spill. This is made possible with electrical housing that additionally functions as a wall surface
precise lighting technology: with the parallel beam version the mounting module are separately constructed, but connected
inverse lamp position controls the beam area of ± 2.5 de- via a rotating hinge. This enables the projector head to be
grees so exactly that the spotlights are suitable as projector variably adjusted and securely fixed with three screws.
systems for the Siteco Mirrortec® reflectors as well as for the
spotlight illumination of towers and buildings.
Features Electrics
— patented light control with inverse mounting position and Projector wired ready for connection | with 3-pole connection
axial lamp arrangement for parallel light distribution terminal, max. 2.5mm² | cable entry for cable D = 6…12mm |
— optimized housing shape: inverse mounting position and with parallel power-factor correction CCG, and ignitor
axial lamp alignment - no shadows from socket or
lampholder Housing
— simple, discreet design Housing of diecast aluminum, coated in white aluminum (RAL
— can be universally used for indoors and outdoors 9006) | projector head and electrical housing with pan-and-
— compact construction with diecast aluminum housing tilt connection; temperature-resistant cover panel | plated
— tool-free relamping and anodized aluminum reflector | tool-free relamping by
opening the upper tube hood | insulation class: I | protection
Lighting technology rating: IP65
Due to patented lighting technology with inverse mounting
position, the beam area is precisely defined:
— version 1: parallel distribution optimized for spotlight
illumination from a greater distance, maximum light output
ratio and uniform lighting in ± 8° beam area | significantly
reduced light immission with less than 1.6% of luminous
flux outside of range ± 10°
— version 2: wide light distribution for floodlighting
5.53
Spotlights and floodlights | Spotlight with rotation symmetric distribution 5
743 427
288 130
494
374
Siteco Mirrortec® Projector 400
1:5*
parallel or wide distribution
[+,7:FIOP
FGNOP
,PD[FGNOPDWJ
wide distribution
1x HIT 250 W E40 19.5 CCG 4039806371409 5NW41421RS2
1x HIT 400 W E40 20.7 CCG 4039806371423 5NW41421TS2
5.54
5 Spotlights and floodlights | Spotlight with rotation symmetric distribution
SiCOMPACT® R3 MAXI
The large SiCOMPACT® R3 MAXI spotlight meets the highest and a very high luminaire lifespan, the projector is equipped
demands for performance and visual comfort as well as with an efficient thermal management system, reflected in the
energy efficiency and operating cost efficiency. As such the construction of the luminaire: Eye-catching cooling ribs
luminaire is perfect for lighting sports arenas and large public dominate the rear of the flat spotlight. This is secured by a
areas. Its innovative construction combines state-of-the-art robust and practical locking catch that can be opened with-
lighting and luminaire technology to achieve light output out tools for maintenance. The luminaire shape and the front
ratios of up to 87%. The spotlight is designed for the use of determine the relatively large surface area optics. The con-
high luminous intensity levels of 2,000 to 3,000 cd/klm and struction of the housing has been kept as flat and as efficient
with up the seven different configurations, can meet a variety as possible in order to minimize the effects of wind. The
of different lighting technology tasks. Its lighting technology special aerodynamics, low weight, and sophisticated sealing
is optimized for the use of high-performance 1,000 or 2,000 system of the luminaire allow for worldwide use in practically
W HIT DE lamps and enables precise light control that mini- any weather conditions.
mizes stray light and glare. For longer maintenance cycles
5.55
Spotlights and floodlights | Spotlight with rotation symmetric distribution 5
Features Electrics
— flat construction: low windage area, low weight Luminaire wired ready for connection | connection box on
— thermal management: main reflector = housing mounting bracket with 3-pole connection terminal (version for
— thermal management: rear reflector flush with diecast immediate hot re-ignition: 4-pole connection terminal), max.
aluminum housing, integrated cooling elements on rear of 2.5mm² | cable entry for cable D = 6…12 mm | luminaire for
housing, connection box with integral ignitor isolated from separate control unit, ignitor or respectively ignitor for
housing immediate hot re-ignition integrated in the luminaire housing |
— integrated pressure equalization all-pole power disconnection upon opening the housing
— lamp cover of safety glass - no protective grid required
— 7 stepped distribution patterns from 2,000–30,000cd/klm Housing
for a wide spectrum of applications 2-part housing of diecast aluminum, coated in Siteco® metallic
— luminaire light output ratio nLB between 84% and 87% gray (DB 702S) | with side mounting bracket of galvanized
— lighting technology partly implemented with new hexa- steel | an all-round silicone seal in the housing profile | cover
gonal faceted technology of flat, temperature-resistant, toughened safety glass |
— v-shaped, inner shield prevents direct view of light source mounting bracket with adjustment feature for floodlight, with
and reduces light spill twist protection | pressure equalization system with air-
— all-pole power disconnection upon opening the housing permeable membrane for condensation avoidance in the
— integral terminal and ignitor box - no external cables housing | insulation class: I | protection rating: IP65
5.56
5 Spotlights and floodlights | Spotlight with rotation symmetric distribution
384
80 250
240
457
500
564
310
SiCOMPACT® R3 MAXI
1$:3
[+,7 '(K:/HLWXQJO
narrow distribution | with mounting bracket
IOP
FGNOP
High performance spotlight with mounting steel; all parts in Siteco® metallic gray
bracket for mounting on a mast using a (DB 702S); reflector of high quality alu-
cross arm or a supporting structure minum, outside matt; cover of toughened
— with reflector made of several reflector safety glass
sections, aluminum with high-purity — protection rating: IP65
surface treatment, for three graded — insulation class: I
narrow light distribution patterns; with — adjustment range: 20…130° (vertical
transparent cover reference line)
— for separate control unit; with ignitor, — 130…180° on request
optionally with hot re-ignition
— housing and ring of cover of diecast alu-
,PD[FGNOPDWJ minum; mounting bracket of galvanized
* optional sighting device for precise alignment of the spotlights to specified set points
& &
D [ [
D [ [
1$:3 Light source Order no. Order no.
[+,7 '(K:/HLWXQJO OSRAM Siteco
IOP
FGNOP
without control unit, with ignitor
narrow distribution LDC1
1x HIT-DE l = 187 1000 W 14.9 - 4039806592323 5NA75601VP11
1x HIT-DE l = 187 2000 W 13.5 - 4039806592460 5NA75601WP11
5.57
Spotlights and floodlights | Spotlight with rotation symmetric distribution 5
5.58
5 Spotlights and floodlights | Spotlight with rotation symmetric distribution
384
80 250
240
457
500
564
310
SiCOMPACT® R3 MAXI
1$:3
[+,7 '(K:/HLWXQJO
wide distribution version | with mounting bracket
IOP
FGNOP
High performance spotlight with mounting steel; all parts in Siteco metallic grey
bracket for mounting on a mast using a (DB 702S); reflector of high quality alu-
cross arm or a supporting structure minum, outside matt; cover of toughened
— with reflector made of several reflector safety glass
sections, aluminum with high-purity — protection rating: IP65
surface treatment, for three graded wide — insulation class: I
light distribution patterns*; with trans- — adjustment range: 20…130° (vertical
parent cover reference line)
— for separate control unit; with ignitor, — 130…180° on request
optionally with hot re-ignition
— housing and ring of cover of diecast alu-
,PD[FGNOPDWJ minum; mounting bracket of galvanized
* AGF module available as an option reduces luminance when luminaire is directly viewed
& & • optional sighting device for precise alignment of the projector to predetermined set points
D [ [
D [ [
1$:3 Light source Order no. Order no.
[+,7 '(K:/HLWXQJO OSRAM Siteco
IOP
FGNOP
without control unit, with ignitor
wide distribution LDC4
1x HIT-DE l = 187 1000 W 13.5 - 4039806592385 5NA75601VP41
1x HIT-DE l = 187 2000 W 13.5 - 4039806592521 5NA75601WP41
5.59
Spotlights and floodlights | Spotlight with rotation symmetric distribution 5
5.60
5 Spotlights and floodlights | Spotlight with rotation symmetric distribution
384
80 250
240
457
500
564
310
SiCOMPACT® R3 MAXI
1$:3
[+,7 '(K:/HLWXQJO
wide distribution | with mounting bracket
IOP
FGNOP
High performance spotlight with mounting steel; housing, ring and mounting bracket
bracket for mounting on a mast using a in Siteco metallic grey (DB 702S); reflec-
cross arm or a supporting structure tor of high quality aluminum, outside
— with reflector made of several reflector matt; cover of toughened safety glass
sections, aluminum with high-purity sur- (ESG)
face treatment, for wide distribution lighting — protection rating: IP65
characteristics*, with transparent cover — insulation class: I
— for separate control unit; with ignitor, — adjustment range: 20…130° (vertical
optionally with hot re-ignition reference line)
— housing and ring of cover of diecast alu- — 130…180° on request
minum; mounting bracket of galvanized
,PD[FGNOPDWJ
* AGF module available as an option reduces luminance when luminaire is directly viewed
• optional sighting device for precise alignment of the projector to predetermined set points
& &
D [ [
D [ [
AGF module
Additional Glare Filter (AGF) to be fitted retrospectively in the spotlight SiCOMPACT® R3 MAXI
| as anti-glare protection to reduce luminance when luminaire is directly viewed
Sighting device
made of aluminum, black | to screw onto spotlight | for precise alignment of spotlights to
specified set points
Hail shield
b Cross-arm
ø16
da
ø21
62
da Mounting information
Mast spigot: da x l
l
Designation b (mm) Mast spigot: da x l (mm) Wt. (kg) Order no. OSRAM Order no. Siteco
— cross arm suitable for floodlight with a max. weight of max = 1x 30kg (please also observe the static analysis and permissible
upper load limit for the mast)
5.62
5 Spotlights and floodlights | Spotlight with rotation symmetric distribution
Control units
to be mounted on the wall, in the switchgear cabinet, to supporting structure or in masts with
appropriate dimensions to operate a projector; with control unit with compensating capacitor |
wired ready for connection with connection terminal 9-pole max. 6mm² | cable entry for
cables D = 8…13.5mm | encapsulated in cast resin, black; floor plate with 2 attachment
points
protection rating: IP65 | insulation class: I
95 l
l1
115
20
Designation Lamp cur- Mains voltage l (mm) l1 (mm) Wt. OSRAM Siteco
rent (A) (V) (kg) order no. order no.
5.63
Spotlights and floodlights | Spotlight with rotation symmetric distribution 5
control unit
94.5 l
l1
115
88
Designation Lamp cur- Mains volt- l (mm) l1 (mm) Wt. OSRAM Siteco
rent (A) age (V) (kg) order no. order no.
Cover panel
For SiCOMPACT R3 MAXI 4050737004822 5NA75600XG
For SiCOMPACT R2 MAXI (for predecessor 5NA726…) 4039806067135 5NA72601XG
5.64
6 Lichtmanagement
Light Management| |Overview
Overview
6.1
Light Management | Overview 6
Siteco ®
Service Box
Page 6.13
6.2
6 Light Management | Street Light Control (SLC)
2 3 4
1 3
1– 4 Luminaire controller operating hours and energy 2 Luminaire with “Plus” (e.g. dimming range of
The luminaire controller is consumption. functional package conventional lamps).
available in two designs: for This becomes a “Premium”
installation in luminaires or 1 Luminaire with variant luminaire by upgrad- 5 LON-PowerLine
for mounting to masts. Both “Premium” functional ing a luminaire controller. PowerLine uses the 230V
are ideal for either retrofitting package supply cable between
existing systems or for new Luminaire designed for use 3+4 Luminaire with luminaire controller and
systems. Thanks to modular with Street Light Control; the dimmable ECG communication module as
design they can be adapted luminaire controller is already By upgrading a luminaire the transmission medium.
to nearly all customer re- integrated. The complete controller, the luminaire can Additional control wires are
quirements. The luminaire functional spectrum for be prepared for integration not required.
controller can switch lumi- operation and monitoring of into the SLC management
naires and reduce luminous the luminaire can be used. system. In this way all SLC
flux for power reduction to functions for control and
any levels. It also measures monitoring become available.
supply voltage, current, This is only limited by lamp
power factor, wattage, manufacturer specifications
6.3
Light Management | Street Light Control (SLC) 6
6 7
6 External light sensor 7 Communication module 8 Transmission To server 9 Central server and
Detects illuminance in the The communications Transmission from the user software
range of 1…150000lx module integrated within the communication module to The central server saves
(0…2000W/m²). Luminaires switch cabinet the server and back is on information and makes this
can be switched directly via — controls the luminaire the IP level via GSM/GPRS data available for further
the sensor coupler accord- controller modem. Further transmis- use. The user software is for
ing to freely definable hyster- — collects information from sion paths such as ethernet configuration and for
esis values, or the variable the luminaires and or optical waveguide are monitoring the lighting
measurement value made — directs this to the central possible. system.
available via PowerLine for server
central or decentral evalua- Phase coupler for 3-phase
tion, or suitable devices be coupling of PowerLine signal.
controlled directly. Antenna for improving
GSM/GPRS signal.
6.4
6 Light Management | Intelligent lighting control
Premium
Plus
Night-time reduction to 50% luminous flux with only approx. 15% consumption via control line
Basic
Overheat Power reduction Flexible lumi- Time-dependent Constant Digital com- Street Light
protection nous flux para- luminous flux luminous flux munication Control
meterisation control control interface
Premium • • • • • • •
Plus • • • • • •
Basic • •
6.5
Light Management | Intelligent lighting control 6
lm lm
Power reduction Time-dependent luminous flux control
All Siteco LED luminaires are equipped with an Siteco LED outdoor luminaires with the “Plus” func-
intelligent connection for detection of power reduction tional package allow reducing the light and therefore
via a switched control wire (230V). energy consumption automatically and without external
Factory setting with power reduction via control wire: control components in the late evening hours. Based
U St = 230V Î 100% luminous flux on the nominal burning period of the previous five days
U St = 0V Î 50% luminous flux (twilight switching) the luminaire calculates an artificial (virtual) midnight.
The switching logic can be reversed by the Siteco ® On the basis of this midnight value, time windows can
Service Box with the “Plus” version. If no control be defined in which the luminaire is reduced in one or
wire exists the luminaire emits 100% luminous flux two steps to freely settable lighting levels. Because of
(connection remains free). the constant internal updating of the nocturnal burning
hours the luminaire adapts automatically to the sea-
Overheat protection sonally varied burning durations.
The temperature of the LED module and operating
°C
electronics is permanently monitored. With excessive Digital communication interface
temperature the lighting level and consumption is auto- This function represents the interface between the
@
matically reduced and the luminaire can cool down. luminaire and the external world. It enables all required
When a lower temperature threshold is attained the parameters such as lighting level, reduction control via
luminaire returns to the original lighting and consump- control wire and automatic night-time reduction to be
tion level. This function is purely a protective function modified according to needs via the Siteco ® Service
to secure the long service life despite possible operat- Box. Connection to higher-level control systems is also
ing errors (e.g. unintended daytime switching with very via this interface (on request).
high ambient temperatures or with direct sunlight).
SLC
During operation within the predefined specifications, Street Light Control
luminaire temperatures remain safe. Connection to Street Light Control enables connect-
@
ing luminaires to our modern, future-fit control system.
lm
Constant luminous flux control Without additional cabling, each light point can be
All light sources, including LEDs, are subject to lumi- individually triggered from a central control point and
nous flux degradation with the progression of the controlled and monitored according to needs and with
t
service life. This must be taken into account in the maximum flexibility and energy efficiency. Data trans-
planning phase and the system must be correspond- mission is via the existing power network via a stan-
ingly over-planned. This leads to excessive illuminance dard LON protocol. By integrating additional sensors
and energy waste. The Siteco constant luminous flux the system can also be expanded according to
control counteracts this degradation, and continuously requirements. Consumption values are recorded and
adds to the output of the LEDs. Luminous flux remains logged, and any luminaire faults are registered auto-
constant over the service life. The light source degra- matically via e-mail or SMS. Maintenance plans can be
dation factor is 1, the maintenance factor is increased. set up as desired and maintenance trips optimised.
In this way, over-planning is no longer necessary. This
means energy-optimised and standardcompliant light-
ing is available at all times.
lm
Flexible luminous flux parameterisation
By the binding to fixed wattages with conventional
lamps (e.g. 70W, 100W, 150W) only in rare cases is
the calculated result of a lighting installation achieved.
The next higher wattage must be specified, the system
is overlit, energy is wasted. With flexible luminous flux
setting the light level can be adapted individually and
precisely to the calculated result. Both the activation
value and reduction value (twilight switching) can be
adapted according to requirements.
6.6
6 Light Management | Street Light Control (SLC)
The innovative Street Light Control (SLC) light management Convenient, expandable, future-proof:
system can control and monitor outdoor lighting systems The system and its components
individually to suit your actual requirements. It not only im- Gradual expansion or introduction across the board. Have
proves road safety, but reduces energy consumption, light the arguments in favor of using intelligent light control via
pollution and operating costs. Street Light Control convinced you? Then you can already
set course for introducing the new technology today.
Street Light Control is based upon PowerLine technology or Depending on your willingness to invest or current budget
radio technology which can be used to expand complete planning, various models of future-proof expansion or
lighting installations to become communicating data net- conversion of your outdoor lighting are available.
works, without the need for installing additional control ca-
bles. Through remote monitoring, the state of each luminaire Switch the right way in a new build
can be tested at any time, luminaire failures can be precisely When installing a new lighting installation, you need to make
located and it is possible to log consumption data and error a decision: Which control components is the system to be
analysis at anytime. Feedback messages enable optimization equipped with? Making a decision in favor of the Street Light
of maintenance processes. All luminaires which have not yet Control luminaire controller and communication modules is
been fitted with the luminaire controller can have it retrofitted the right decision to make. With this local network, you set
so that they can be integrated into the Street Light Control the foundations for changing over to intelligent light control
light management system. The luminaire controller is suitable with Street Light Control.
for luminaires with an ECG dimmable ECG (1…10V or DALI)
as well as luminaires with a magnetic control unit and also Benefit immediately from all the advantages
luminaires with a reducing relay. This provides new energy To be able to immediately benefit from all intelligent light
savings opportunities and reduces operating costs. Exam- control advantages, install the complete system. You need to
ples are flexibly dimming the lighting on a bright night, when take the following measures:
there is little traffic, meaning less light is required, and also
increasing the amount of light to above normal in the event of 1. Equip the light points with PowerLine-capable or radio
an accident or bad weather. controlled luminaire controllers and dimmable ECGs.
2. Set up an infrastructure with communication modules
Street Light Control offers maximum compatibility and invest- 3. Set up the IT structure in the administration (software,
ment security because it uses open, standardized interfaces central server, training etc.).
and protocols.
6.7
Light Management | Street Light Control (SLC) 6
6.8
6 Light Management | Street Light Control (SLC)
54 66
220
100
900
1000
Street Light Control luminaire controller
for mast recessing
6.9
Light Management | Street Light Control (SLC) 6
123
99
33
28
79
67
111
— please order inductivity for absorption with ECG luminaires separately if required
— please order empty housing separately if required
— please order further SLC light management components separately if required
6.10
6 Light Management | Street Light Control (SLC)
230 110
300
115
Street Light Control communication module
for wall mounting
6.11
Light Management | Street Light Control (SLC) 6
203
123
99
188
160
Street Light Control light sensor
for mast or wall mounting
Street Light Control light sensor for mast or — protection rating: IP65
wall mounting — insulation class: II
— for connection to light sensor coupler — measurement range: 1…150klx
— light sensor detects the daylight and (0…2000W/m²)
supplies variable measurement value to — incl. connection cable with UV-resistant
the sensor coupler insulation, l = 10m; cable pluggable at
— aluminum housing with PC cover, white; both ends
mounting bracket and mast clamp of — incl. coupler and mounting bracket
galvanized steel; sensor unit cover of
glass
Phase coupler
for 3-phase coupling of the PowerLine carrier signal into the 230V grid | to increase the
capacitive coupling between the 3 external conductors; to minimize the signal attenuation
during transmission | galvanically separate (un)coupling of the carrier signal | for installation in
distribution box, 2TE
protection rating: IP 20 | insulation class: I
6.12
6 Light Management | Siteco Service Box
The Siteco® Service Box enables the parameterization of the saved in the luminaire. The values already set for a luminaire
LED operating electronics for all Siteco LED street lights with can be transmitted as an individual parameter file in the
the “Plus” functional package to be carried out. The lighting Siteco® Service Box. These files can then be transmitted later
levels can be set for flexibly setting luminous flux parameters on to more luminaires of the same kind, so that uniform and
as well as the reducing values of the two-stage, time depen- quick parameterization of all LED light heads along a street is
dent luminous flux control and up to 4 times for the luminous ensured.
flux control. The switching logistics of the power reduction
can also be reversed with a 230V control signal. It is even quicker to set these parameters using the control
software on a PC and then transmit them as a complete
The Siteco® Service Box is incorporated into the luminaire parameter file via USB to the Siteco® Service Box. Connected
feed cable either while the luminaire is mounted directly in the to the interface in the luminaire, these parameters can be
cable junction box in the mast via a Y-connection cable or in completely transmitted to the operating electronics of the
advance on the unmounted luminaire. The values for the luminaire by the Siteco® Service Box.
corresponding luminaire can be defined individually and
Features Electrics
— a single parameterizing tool for all Siteco® LED road Siteco® Service Box with plug-in coupling and Y-cable (cable
luminaires with the “Plus” functional package set for looping Service Box into the luminaire cable at mast
— weather-resistant applications thanks to high protection doors or in workshop) | with mounted luminaire: Luminaire
rating cable with corresponding plug-in coupling required (“mast
— luminaire parameterization is possible by installer without cable set”)
special system knowledge Siteco® Service Box with mini-USB for connection to PC
— luminaire parameters can either be set on the mounted
luminaire or in the workshop Housing
— quick, economic adjustment of luminaire parameters by Plastic housing, black; plug-in coupling with protective cap |
connecting the Siteco® Service Box via the mast doors protection rating IP54
— copy function: parameters of a luminaire can be simply
and rapidly transferred to further luminaires
— reading out luminaire operating data and parameters,
management of data on PC
6.13
Light Management | Siteco Service Box 6
121 50
251
Siteco® Service Box
for LED road luminaires with Plus functional package
— for setting parameters on mounted luminaires: Luminaire cable with corresponding plug-in coupling required (“mast cable set”)
www.siteco.com > Service > Downloads > Software > PC tools > Architainment Suite
Siteco® Architainment Suite has been tested for the following operating systems: Windows
XP, Vista.
6.14
7 Accessories
Sachsen Anhalt
Wind zone 3
Nordrhein-Westfalen
Cat. II Vref = 27.5m/s
Agricultural areas with Düsseldorf
Sachsen
Thüringen
houses, or trees Hessen Vref = 30.0m/s
Wiesbaden
Cat. II Mainz
Bayern
Cat. IV Stuttgart
Baden-Württemberg
Urban areas in which at least
15% of the area is developed 2 München
Wind load
Masts for higher loads (e.g. for multiple arrangements, wind zone 4) available upon request
Basic mast type Mast height h1 (m) Permissible AW values for luminaires (m2)
WZ 1 WZ 2 WZ 3
7.1
Accessories 7
Basic mast type Mast height h1 (m) Permissible AW values for luminaires (m2)
WZ 1 WZ 2 WZ 3
Basic mast type: The specified order number is not complete; please provide the following numbers when ordering
Supplement the order table (see following page)
7.2
7 Accessories
Masts
da da
l
l
h1
h1
h3
600
600
500
500
h2
h2
d2 d2
Mast
Straight steel mast for post-top mounting of luminaires as per DIN EN 40 | depending on the
version, conically round or cylindrically offset | spigot calibrated | mast made of steel
(S235JR), hot-dip-galvanized as per EN ISO 1461, additionally powder-coated at Siteco®
metallic gray depending on version (DB 702S); wall thickness 3 mm | door inserted (painted
mast) or placed on top (unpainted mast)
7.3
Accessories 7
Masts
Mast height Recess Planted Planted Wt. Order No. OSRAM Order No. Siteco
h1 (m) h3 (m) section section (kg)
h2 (m) d2 (mm)
— standard mast zinc-plated and painted, Siteco® metallic gray (DB 702S) | for zinc-plated, unpainted mast, please replace the
number “8” at the end of the order number with the number “0”. Corresponding OSRAM order number on request.
— other RAL colors and DB color tones available on request.
Shrink-on sleeve
for mast, d2 ≤ 114mm 4039806381019 5NY23101XM114
for mast, d2 > 114mm 4039806381026 5NY23101XM191
Base plate
Dimensions 250 x 250 x 3mm 4039806380975 5NY23101XB250
Dimensions 400 x 400 x 4mm 4039806380982 5NY23101XB400
7.4
7 Accessories
Reducer
For post-top or insertion mounting on the mast | steel (S235JR), hot-dip-galvanized as per
DIN EN ISO 1461 | fastened to the mast with threaded pin*
*with variants for insertion mounting, on-site hole drilling on the mast required
d2 a d2 a
l2
30
h
x
da da
Fig. 1 Fig. 2
Version Fig. Mast with spigot size Reducer Onsite hole drilling on the mast Wt. (kg) Order No. OSRAM Order No. Siteco
da (mm) l (mm) d2a (mm) l2 (mm) h (mm) Ø (mm) x (mm)
7.5
Accessories 7
Without interior pre-wiring | for 3 cables up to 5x 16mm² | with one or two fuse bases
Fuse insert Terminals Dimensions Order No. OSRAM Order No. Siteco
H x W x D (mm)
Accessories
Ground line 4039806200013 5NY70001XE
Interior pre-wiring made of nickel-plated brass rail | for 2 cables up to 5x 16mm² or 3 cables
up to 5x 10mm² | includes two fuse bases | two luminaire connection lines may also be
mounted below parallel to the access cable as an option
Fuse insert Terminals Dimensions Order No. OSRAM Order No. Siteco
H x W x D (mm)
Accessories
Ground line 4039806200020 5NY70002XE
Cable junction box for mast installation | Contact protection as per BGV (Accident Prevention
Regulation) A2 (VBG 4) | Fuse base D01, with screw cap E14 | Exit to the luminaire with 2x
exit grommets each | Housing made of impact-resistant plastic
7.6
7 Accessories
Interior pre-wiring made of nickel-plated brass rail | for 3 cables up to 5x 16mm²; terminal
“L4” to secure the control line during power reductions | includes two or three fuse bases |
two luminaire connection lines may also be mounted below parallel to the access cable as an
option (not suitable for mast 5NY231630KM... or 5NY231635KM...)
Fuse insert Terminals Dimensions Order No. OSRAM Order No. Siteco
H x W x D (mm)
Accessories
Ground line 4039806200037 5NY70003XE
7.7
Accessories 7
Galvanized steel; may also be painted depending on version, Siteco® metallic gray (DB 702S)
| suitable for conically round and cylindrical mast | affixed to mast with an Allen screw
* when selecting the mast, the statics and the permissible load limit of the mast (windage area and weight of the luminaires and
brackets, wind speed according to wind zone, snow load, terrain category, etc.) must be considered.
a
a
d2
250
3xM8x16
da
7.8
7 Accessories
Galvanized steel | suitable for conically round and cylindrical mast | includes offset bracket
arms and cable routing area (upper cover removable) | affixed to mast with an Allen screw
* when selecting the mast, the statics and the permissible load limit of the mast (windage area and weight of the luminaires and
brackets, wind speed according to wind zone, snow load, terrain category, etc.) must be considered.
a d
a
d2
3xM8x16
250
100
da
7.9
Accessories 7
Steel, zinc-plated | suitable for cylindrical mast | affixed to mast with threaded pin
Version Fig. Aw (m²) Wt. (kg) Order No. OSRAM Order No. Siteco
155 1435
990
570
ø60
ø60
2x(3xM8x12)
100
180
185
2x(3xM8x12) ø76
ø76
Fig. 1 Fig. 2
7.10
7 Accessories
d2 a
2°
ø76 Decorative mast bracket for side-entry mounting of luminaires
1350
Galvanized steel or zinc-plated and painted Siteco® metallic gray (DB 702S) | suitable for
1000
conically round or cylindrical mast | affixed to mast with threaded pins | approved for wind
zone 3, permissible luminaire weight: max. 22kg (per support arm)* | bracket for wall
130
a Version a (mm) Aw (m²) Wt. (kg) Order No. OSRAM Order No. Siteco
15°
a
2-arm 1500 0.43 34 4039806806406 5NY0410M215A
ø76
10°
h4
l2
“Donau” bracket; spigot size support arm d2a = 60mm
215
ø76
1-arm 1200 0.25 20 4039806806277 5NY0410M112E
“Bern”
2-arm 1200 0.37 32 4039806806383 5NY0410M212E
1-arm 1500 0.28 22 4039806588791 5NY0410M115E
2-arm 1500 0.43 34 4039806806420 5NY0410M215E
l2
1-arm 800 0.12 19 4039806806468 5NY0420M108E
h4
ø76
2-arm 800 0.19 24 4039806806567 5NY0420M208E
10°
260
a Version a (mm) Aw (m²) Wt. (kg) Order No. OSRAM Order No. Siteco
d2 a
2°
ø76 “Innsbruck” bracket; spigot size support arm d2a = 60mm
1-arm 1200 0.25 18 4039806806086 5NY0400M112E8
1350
1000
a
1-arm 1500 0.28 22 4039806806307 5NY0410M115A8
15°
a
1-arm 1200 0.16 21 4039806599681 5NY0420M112A8
ø76
10°
l2
1-arm 1500 0.24 23 4039806806512 5NY0420M115A8
215
ø76
10°
“Luzern”
2-arm
7.12
7 Accessories
Decorative mast bracket and wall bracket for post-top mounting of luminaires
Galvanized steel and painted, Siteco® metallic gray (DB 702S) | suitable for cylindrical mast |
affixed to mast with threaded pins
Version Aw (m²) Wt. (kg) Order No. OSRAM Order No. Siteco
Wall bracket
Rocker 0.09 6.8 4039806215932 5NY52660XG18
Rail 0.15 8.8 4039806216014 5NY52660XN18
Mast bracket
Rocker, 1-arm 0.09 7.8 4039806216694 5NY52650XG18
Rocker, 2-arm 0.18 12.0 4039806215833 5NY52650XG28
Rail, 1-arm 0.15 9.8 4039806215857 5NY52650XN18
Rail, 2-arm 0.30 16.0 4039806215895 5NY52650XN28
220
220
475
475
220
475
ø76 ø76
ø76
ø76 ø76
Rail type
320
655
210
320
320
655
ø76
655
ø76
ø76
ø76
Rocker type
7.13
Accessories 7
For mounting luminaires on the wall or corners of buildings | flange made of die-cast
aluminum, light gray (RAL 7035)
Designation da (mm) Arm length Wt. (kg) Order No. OSRAM Order No. Siteco
L (mm)
— please order support arm in the required diameter and in the desired length in addition to the wall or corner flange
160 130 60
da
120 60
da
60 l
da
15°
15°
140
200
200
140
120
143
90
Designation da (mm) Wt. (kg) Order No. OSRAM Order No. Siteco
110 53
da
10°
140
200
138 353
41
7.14
7 Accessories
Metal gear tray with fastening bracket for roof | open distribution, reflector or shielding can be
mounted without tools | includes socket adjustment for optimum positioning within the
reflector | CCG, power-factor correction; power reduction or with ECG depending on version |
insulation class: I/II
Light source Power reduction CITY-LIGHT CITY-LIGHT CITY-LIGHT LANTERN MUSHROOM Order No. OSRAM Order No. Siteco
Bollard pillar LUMINAIRE
Insulation class I
1x HIE/HIE-CE 35W X X X 4039806904850 5NA519E1H
1x HIE/HIE-CE 70W X X X 4039806904911 5NA519E1L
1x HSE 50W X X X 4039806248749 5NA519E1M
1x HSE 70W X X X X 4039806248756 5NA519E1MR
2x HSE 50W X X 4039806248787 5NA519E2M
1x HSE 100W X X X 4039806248763 5NA519E1N
1x HSE 100W X X X X 4039806248770 5NA519E1NR
2x TC-LEL 18/24W, with CCG X X 4039806058508 5LA51922K
Insulation class II
1x HIE/HIE-CE 35W X X X X X 4039806858719 5NA520E1H
1x HIE/HIE-CE 70W X X X X X 4039806865489 5NA520E1L
1x HSE 50W X X X X X 4039806248794 5NA520E1M
1x HSE 70W X X X X X X 4039806248800 5NA520E1MR
1x HSE 100W X X X 4039806248817 5NA520E1N
1x HSE 100W X X X X 4039806248824 5NA520E1NR
2x TC-LEL 18/24W, with ECG X X X X X 4039806082701 5LA52072K
7.15
Accessories 7
Includes axial lamp socket for suspended lamp arrangement | open distribution, reflector can
be mounted without tools | with CCG, power-factor correction; power reduction or with ECG
depending on version; plug contact for positively driven electrical connection | plastic gear
tray for torsion-resistant installation | insulation class II (only together with the housings
approved for insulation class II)
Light source Power reduction SMALL LARGE TEKTUS Order No. OSRAM Order No. Siteco
BELL BELL MAXI
Raised socket
1x HIE/HIE-CE 70W X X X 4039806399373 5NA140E1LA
1x HSE 50W* X X X 4039806247551 5NA140E1MA
1x HSE 70W X X X X 4039806247568 5NA140E1MB
2x TC-LEL 18W, with CCG X X X 4039806071330 5LA14022KA
2x TC-LEL 18W, with ECG X X X 4039806071217 5LA14072KA
Recessed socket
2x TC-LEL 18/24W, with ECG X X 4039806071231 5LA14072KG
Includes vertical lamp socket for side-mounted lamp arrangement | open distribution,
reflector can be mounted without tools | with CCG, power-factor correction; power reduction
or with ECG depending on version; plug contact for positively driven electrical connection |
plastic gear tray for torsion-resistant installation | insulation class II (only together with the
housings approved for insulation class II)
Light source Power reduction SMALL LARGE TEKTUS Order No. OSRAM Order No. Siteco
BELL BELL MAXI
7.16
8 Media Solution
8.1
Media Solution 8
8.2
8 Media Solution
Features Electrics
— wide color range including RGB and dynamic white — operation with mains voltage, no supplementary power
— high light intensity, high efficiency supply unit required
— adaptable to spatial conditions due to various luminaire — dimmable via forward phase control – flicker-free dimming
lengths from 5% to 100% (versions with white light color)
— flexible light distribution due to rotation through 180°
— simple cabling (plug & play) and simple connection, even Applications
in tight installation conditions — exterior lighting
— simple installation and low maintenance costs with plug & — exterior architecture, commerce, hotels and restaurants
play system — planar illumination
— diverse lighting scenes due to 16.7 million colors (version — linear or indirect lighting
with RGB LEDs) — all applications requiring economic lighting with a slender
construction form
Lighting technology
— extremely slender linear light system with high lumen
output and energy efficiency
— available with beam angles: 40° (diffuse light), 50° x 10°
(focused light)
8.3
Media Solution 8
8.4
8 Media Solution
l 42
78
±90°
l1
6.2
16
— luminaire light output ratio: 60lm/W — distance with series switching: up to 25m
(3,000K), 65lm/W (4,000K) (230V)
— available color temperatures: 3,000K, — luminaire length: 309mm
4,000K (6,500K on request) — protection rating: IP66
Accessories
8.5
Media Solution 8
l 42
78
±90°
l1
6.2
16
— luminaire light output ratio: 60lm/W — distance with series switching: up to 25m
(3,000K), 65lm/W (4,000K) (230V)
— available color temperatures: 3,000K, — luminaire length: 912mm
4,000K (6,500K on request) — protection rating: IP66
Accessories
8.6
8 Media Solution
l 42
78
±90°
l1
6.2
16
— luminaire light output ratio: 60lm/W — distance with series switching: up to 25m
(3,000K), 65lm/W (4,000K) (230V)
— available color temperatures: 3,000K, — luminaire length: 1,214mm
4,000K (6,500K on request) — protection rating: IP66
Accessories
8.7
Media Solution 8
l 42
78
±90°
l1
6.2
16
— luminaire efficacy: 23lm/W (RGB versions), — distance with series switching: up to 25m
40lm/W (dynamic white versions) (230V)
— luminous flux: 990lm/m (RGB versions), — luminaire length: 310mm
1,750lm/m (dynamic white versions) — protection rating: IP66
— stepless color temperature modification:
2,700K…6,500K (dynamic white versions)
Accessories
8.8
8 Media Solution
l 42
78
±90°
l1
6.2
16
50%
— luminaire efficacy: 23lm/W (RGB versions), — distance with series switching: up to 25m
40lm/W (dynamic white versions) (230V)
60 °
— luminous flux: 990lm/m (RGB versions), — luminaire length: 611.5mm
75% 1,750lm/m (dynamic white versions) — protection rating: IP66
— stepless color temperature modification:
100% 15° 30° 45° 2,700K…6,500K (dynamic white versions)
Accessories
8.9
Media Solution 8
l 42
78
±90°
l1
6.2
16
— luminaire efficacy: 23lm/W (RGB versions), — distance with series switching: up to 25m
40lm/W (dynamic white versions) (230V)
— luminous flux: 990lm/m (RGB versions), — luminaire length: 913mm
1,750lm/m (dynamic white versions) — protection rating: IP66
— stepless color temperature modification:
2,700K…6,500K (dynamic white versions)
Nano Liner Allegro AC XB-27 RGB 40 deg 230V MULTIPXL (9 DMX channels)
27 40 RGB RGB 230 37.2 912 25 3.7 4006584804160 0TXNA00000737
Accessories
8.10
8 Media Solution
l 42
78
±90°
l1
6.2
16
— luminaire efficacy: 23lm/W (RGB versions), — distance with series switching: up to 25m
40lm/W (dynamic white versions) (230V)
— luminous flux: 990lm/m (RGB versions), — luminaire length: 1,215.5mm
1,750lm/m (dynamic white versions) — protection rating: IP66
— stepless color temperature modification:
2,700K…6,500K (dynamic white versions)
Nano Liner Allegro AC XB-36 RGB 40 deg 230V MULTIPXL (12 DMX channels)
36 40 RGB – 230 49.6 1236 25 5.0 4006584804443 0TXNA00000733
Accessories
8.11
Media Solution 8
8.12
9 Appendic | Contents
9.1
Appendic | Contents 9
Contents
1 Photometric data explanations
2 Explanation of symbols
3 Lamps typically used for outdoor lighting
4 Information on the energy consumption designation
5 Lighting planning
6 Light and the environment | Light immission
7 Notes on switching
8 Light Solutions Center – LSC
9 Siteco luminaire test road
10 Materials in luminaire construction
11 Colours and surfaces
12 General Business Conditions
13 Guarantee declarations
14 Sales
9.2
9 Appendic | Photometric Data Explanations
1 Photometric
data explanations
Light distribution curve
6
1$(67&
2
[+67 0)://IOP 1
3
3 & &
/LFKWVWÁUNHNODVVHQDFK
7
(1*
4 5
1 | φ: Luminous flux of lamp in [lm] 4 | Continuous line: The specifications in the photometric
according to lamp manufacturer speci- Luminous intensities I at C180° data are based upon measurement
fications, measured at 25°C ambient Dotted line: results with goniophotometers and
temperature and unshielded. With LED, Luminous intensities I at C270° Ulbricht spheres according to valid
the net luminaire luminous flux φN measurement criteria and are only
5 | Continuous line: significant for the specified luminaire
2 | Quantity, type and light colour of Luminous intensities I at C0° type in combination with the speci-
lamp, usually according to the ZVEI Dotted line: fied light sources. Depending upon
lamp designation system Luminous intensities I at C90° the type of luminaire, the most rea-
sonable or possible specifications are
3 | Light distribution as polar curve. 6 | Order number of luminaire, with selected.
Specification of γ angle in [° ]. accessories where applicable
Specification of luminous intensities I in More detailed photometric
[cd/klm]. The actual luminous intensi- 7 | Luminous intensity class specifications for all products at
ties are calculated via multiplication according to EN13201-2 www.siteco.com
with luminous flux of the lamp in [lm] for outdoor luminaires
divided by 1000. The centre of the
auxiliary circle (scale of luminous inten-
sities I) or initial point of the auxiliary
lines (scale of γ angle) is the light focal
point of the luminaire or median point
of the light emission aperture
9.3
Appendic | Photometric Data Explanations 9
Supplementary photometric explanations for narrow distribution spotlights/projectors for outdoor applications
1$:3
[+,7 '(K:/HLWXQJO
IOP
FGNOP ,PD[FGNOPEHLJ 10
8
8
& &
D [ [ 9
D [ [
8 | Light distribution as Cartesian dia- 9 | α50 %: half-peak divergence in [°]. 10 | Imax : maximum value of luminous
gram with levels C0° and C180°, and This specifies at which angle the lumi- intensity I in [cd/klm] and γ angle at
C90° and C270° nous intensity I still consists of 50 % which this is emitted.
of maximum value. Imax consists of
α10 %: One-tenth peak divergence in
[°]. This specifies at which angle the
luminous intensity I still consists of
10 % of maximum value. Angle speci-
fications usually define the sum of
angles in the levels CO° and C180° or
C90° and C270°, e.g. 2 x 10°
9.4
9 Appendic | Photometric Data Explanations
12
3 11
11
11 | Light distribution as Cartesian dia- 12 | Inclination: with floodlights the Some luminaires were measured with
gram with levels A0° (identical with lev- luminaire is tilted before measuring so C levels; here no tilt is specified. The
els C0° and C180°) and level B0° far that the maximum in levels A0 and tilt angle in the Cartesian diagram cor-
B0 is equivalent to γ = 0°. responds to the angle to which the
In this way, the width of the light floodlight in the polar curve emits light
emission can be more precisely deter- asymmetrically to the vertical.
mined than with a measurement with
C levels, thus enabling a higher meas-
urement accuracy.
9.5
Appendic | Photometric Data Explanations 9
Isolux curves represent illuminance /LFKWSXQNWKÓKHP1HLJXQJ
distribution upon virtual or real surfac- O[
es, e.g. on a road, on a floor or a wall.
Points of equal illuminance E in [lx]
('Isolux') are connected with a curve.
The illuminance values are dependent
upon the distance between luminaire
and surface. A maintenance factor of
0.8 is applied. Isolux curves demon-
strate the effect of the lighting charac-
teristics of a luminaire. (rotosymmetri-
cal / asymmetric / linear).
P
/LFKWSXQNWKÓKHP1HLJXQJ
O[
P
9.6
9 Appendic | Explanation of Symbols | Light Distribution
2 Explanation of symbols
Floorstanding uplight, direct/indirect Suspended ground wallwasher Surface-mounted ceiling luminaire
asymmetric medium/wide direct wide/diffuse distribution
distribution with ceiling illumination
Suspended luminaire, direct/indirect Surface-mounted ceiling luminaire Recessed ceiling directional spot
medium/wide distribution direct narrow distribution tiltable
with ceiling illumination narrow distribution
9.7
Appendic | Explanation of Symbols | Light Distribution 9
9.8
9 Appendic | Explanation of Symbols
Certification symbols
Luminaires with the VDE symbol Luminaire is suitable for use with Luminaires approved for explo-
have been approved by the VDE railway platforms/tracks. ZONE sion-hazard zone 2 according to
inspection and certification insti- The angle-dependent maximum Ex-guideline 94/9/EG.
2
tute. The basis for approval are luminous intensities correspond Explosion-hazard zone 2 accord-
the safety regulations applicable in to the specifications of German ing to ElexV 1996: areas where
Germany Railways. explosive atmospheres from gases,
vapours or haze are not expected,
but if they still occur then probably
The ENEC symbol (European Luminaires tested for protection only seldomly and for a short time
Norm Electrical Certification) is a against flying balls according to the
European inspection and certifica- latest European standard EN 12
tion symbol for luminaires and elec- 193 (or DIN VDE 0710)
trical components within luminaires.
It testifies to compliance with the Luminaires approved for explosion-
European standards for safety and
work practice. A 10 signifies that Luminaire tested for protection ZONE hazard zone 22 according to
Ex-guideline 94/9/EG. Explosion-
inspection was carried out by the against flying balls in tennis areas 22
according to DIN VDE 0710 hazard zone 22 according to
VDE. The VDE symbol can be addi- ElexV 1996: Areas where explosive
tionally attached to the luminaire atmospheres from whirled-up dust
are not expected, but if they still
occur then probably only seldom
and for a short time
Live parts are equipped with protec- Protection against electric shock is
tive isolation in addition to the basis implemented with basis isolation and
isolation. Connection of an earth connection of all touchable metal
conductor is not permitted unless a components with the earth conductor
special terminal for through-wiring is Luminaire tested for impact energy
integrated of 2.00 joules. IK 07 designation
IK07 according to EN 50102
Safety and convenience package Radio management for transmission The CE symbol only documents
for protecting luminaire and for gen- of control commands in compatibility with European guide-
tle lamp operation 433.42 MHz ISM band lines valid for the product. The CE
— Ignitor with digital automatic designation is not an 'approval seal'
power disconnection but a management designation
— Ballast with thermal protection expressing the free movement of
— Power reduction (ECO) with products in the European domestic
integral timer for lamp start at market according to designated
full load industry products.
9.9
Appendic | Explanation of Symbols 9
DALI (Digital Adressable Lighting Symbol for good industrial design. Recycling symbol of the corrugated
Interface) is an interface definition Products designated with the IF board industry
for controlling digitally dimmable logo have been distinguished by the
ballasts. A maximum of 64 DALI Industrieforum Design Hanover for
ballasts can be operated on one outstanding product design
control line. These can be grouped
in a maximum of 16 overlapped
groups. A maximum of 16 lighting
scenes can be stored. The defini-
tion of the protocol is regulated in
the appendix of EN 60929
No application for our packaging All luminaire packaging from Siteco Recycling symbol with material
(see Interseroh) Beleuchtungstechnik GmbH is specification
accepted free of charge by the
company of Interseroh and dis-
posed of in an environmentally
friendly way
Protection against touching active, Protection against access into lumi- Dust-tight luminaire
live parts with fingers naire housing via a 1 mm thick wire
IP20 IP 44 and against ingress of splash water IP60
Protection against touching live Dust-protected luminaire Dust-tight and water-jet protected
parts with fingers and against the luminaire
IP23 ingress of spray water (e.g. rain). IP50 IP65
According to EN 60598, luminaires
are inspected in their specific
installation situations. With indoor
luminaires this is the normative
recess box that protects against the Dust and splash water Dustproof and protected against
ingress of water into the luminaire. -protected luminaire strong water jets. Note: With tunnel
This special protection can be rec- IP54 IP66 luminaires with the additional speci-
ognised by the specification IPX3 fication of 6 bars. The luminaire is
'Lichtaustrittsöffnung/aperture' tested with a pressure of 6 bars with
a water jet nozzle according to RVS
09.02.41 Section 6.3.8
Protection against access into lumi- Dust and water jet-protected Dustproof and protected against
naire housing via a 1 mm thick wire luminaire temporary immersion in water
IP40 IP55 IP67
9.10
9 Appendic | Explanation of Symbols | Information Symbols with Installation Instructions
Warnings
Symbols
Sections of the installation instruc- Luminaire is suitable for use indoors Adjustment possibilities for lamp
tions bearing this symbol refer to position described
the condition on delivery
Luminaire is suitable for use indoors Luminaire is suitable for use in un- Adjustment possibilities for reflector
and in unprotected installations protected installations outdoors position described
outdoors
9.11
Appendic | Explanation of Symbols | Information Symbols with Installation Instructions 9
Symbols
LPH
looping through
[ mm ]
Aw
60% Humidity, limitation Circuit with PF correction Windage area in shown projection
without evaluation with air resist-
ance coeffi cient (max. value is 1.2
10% acc. to EN 60598-2-3)
E
lamp rating
Protective earth. Earthing of prod- Cable not subjected to tensile load Must not be cleaned
uct in system, installation or device with a damp cloth
required for correct functionality,
but not part of protection against
electric shock
Replaceability (time period, Special cleaning instruction for
cable designation) specific luminaire materials
clean
also see MA 243299
Protective earth connection
General information
Wear protective gloves Installation and maintenance only 0h 4000h Specification of recom-
4000h
9.12
9 Appendic | Information on Lamps
Light source/lamp type LED Metal halide lamps Metal halide lamps
with ceramic burner with quartz burner
Re-ignition instant •* •*
Dimmability stepless from 0–100% conditionally; for certain types stepless, approx. 30–100 %
Lamp type Tubular, ring-shaped Tubular, ring fluorescent lamps Compact fluorescent lamps
fluorescent lamps with amalgam technology
ZVEI designation e.g. T16, T26, T16-R T16-RI, T16-I TC-S, TC-SEL, TC-D, TC-DEL, TC-T,
TC-TEL, TC-LEL, TCR-TSE flat, TC-DD
Possible dependencies switching frequency, operation switching frequency, dimming switching frequency, operation on ECG
of lifespan on EVG or LLCGG, dimming or LLCG, dimming
Dimmability stepless from 1–100% stepless from 30–100% type-dependent stepless from 1–100%
9.13
Appendic | Information on Lamps 9
4 1B –
3x–2x 8x –
•* •* •*
no no
1B 1A 1A
8x 100 100
*after > 10 min; possible instantly for limited types with considerable technical effort
9.14
9 Appendic | Information on Energy Consumption Designation
9.15
Appendic | Information on Energy Consumption Designation 9
9.16
9 Appendic | Lighting Planning
5 Lighting planning
Tools for the calculation of outdoor lighting systems
The modernisation of obsolete street lighting systems With Siteco's online calculation programmes you can easily
certainly pays. Around 2.7 billion kWh of energy, 1.6 million find out which energetic savings potential exists. Our website
tons of CO² and thus 400 million euros are available for this has tools such as the Siteco Lighting Tool and a cost efficien-
in Germany alone. The quickest way to implement this cy calculator as well as sample projects for such purposes.
is the refurbishment of old lighting installations with new,
energy-efficient luminaires and lighting technologies.
9.17
Appendic | Lighting Planning 9
Siteco Lighting Tool luminaires from the Siteco product spectrum, and provides
The tool enables you to select a product with just a few answers to the following questions for example (here with
clicks and to transfer this to the RELUX and DIALUX road lighting): Which luminaire meets the specified light-
lighting planning programs. The product ranges Indoor ing class with the widest mast spacing? Which luminaire
and Outdoor are available. The products can be selected meets the specified lighting class with the lowest energy
via the catalogue structure (product segment, group or consumption per metre? Which lighting class is met by the
family) or via features (mounting method, lamp type, lamp luminaire for a specific road arrangement? Results can be
quantity, control unit etc.). The tool also offers the com- printed out or saved as PDF files.
plete text search as a further search option. Data can be
forwarded to DIALUX and RELUX via drag and drop. The The cost efficiency calculator:
Siteco Lighting Tool is currently being expanded with an http://www.siteco.com/de/planungshilfe/
application search function for indoor and outdoor appli- lichtberechnung.html
cations. The tool is aimed at users having knowledge of
lighting planning and specifically valid standards. The tool
is intended to provide support when searching for optimal
9.18
9 Appendic | Light and Environmental Protection | Light Immission
9.19
Appendic | Light and Environmental Protection | Light Immission 9
Lighting technology:
Suitable optics enable only desired surfaces to be illumi-
nated. In particular, useless direct radiation of lighting into
the sky can be limited in this way.
0% 0% 0° < 3%
9.20
9 Appendic | Notes on Switching
7 Notes on switching
Instant hot re-ignition
The security luminaire sector, technical traffic critical Ignition device with automatic power disconnection
areas and logistics hubs require illumination that is as free Advantages:
of interruption as possible. Special ignition devices are — no pulses of the HS lamps at the end of the lamp
required for immediate (within 0.2 seconds) reignition of service life
high-pressure lamps that go out for system reasons after a — reduction of interfering pulses in the network
voltage interruption or a power failure. — easier identification of defective lamps
Due to these instant re-ignition devices) a transient voltage of — self-protection of the ignition device – longer service life
20…40 kV is applied to the lamp, which makes it possible to The disadvantage:
ignite the lamp in hot condition. Due to the high ignition — higher price
voltages only lamps with 2-sided connection are suitable. The
usual cooling procedure necessary before ignition of the lamp Note: when changing lamps under voltage the ignition
can take place with a normal ignitor is unnecessary. Multiple device must be reset by voltage interruption for a test.
repeat ignition processes can damage and impair
the function of lamp and ignition device. Not all metal vapour and high pressure sodium lamps
require an ignition device for ignition. Thanks to an ignition
Ignitors device integrated in the lamp or special fillings of the burner
The highly efficient metal vapour lamps and high pressure the mains voltage in conjunction with the ballast suffices for
sodium lamps require a suitable ignition device. ignition.
The ignition devices for HCI, HIT/HIE and HSE/HST lamps
provide ignition voltage from 1.8…5 kV depending on the Lamp types for operation without ignition device
type. The ignition devices work as superimposed-pulse igni- Metal halide lamps
tors. This means that the ignition devices are in the power — HIT 2000N, 2000/DI
circuit, and if a lamp is defective the ignition device attempts
to ignite without interruption; this can destroy the ignition High pressure sodium lamps
device or cause disturbances in the power supply network. — HSE-I 50, 70
To exclude the possibility of this situation occurring, ignition — HSE-X 110, 210, 35
devices with automatic power disconnection are available.
LP
9.21
Appendic | Notes on Switching 9
General information
Luminaires are available with special Controlled reducing relay
equipment to save energy in times of This is the standard in systems with
low traffic density. These luminaires control lines because of low costs
enable a reduction of lamp wattage and because with central controlling
and related luminous flux. HME and this is implemented optimally accord-
HSE/HST lamps can be operated in ing to requirements (coordinated to
power-reduced mode to 50% of nom- traffic density on work days and holi-
inal wattage, presupposing that start- days, shift times etc.).
up is with the nominal wattage.
Fixed switching relay
If the luminaire is brought into opera- A good solution for networks with-
tion when 50% light mode is active out control lines that aim to achieve
this frequently causes unstable energy savings with luminous flux
operating states (insufficient light, reduction. A preset time period for the
shortened lamp lifespan). In these reducing circuit is pre-programmed
situations a reducing relay with timer and automatically activates every
is required. night. Currently 2 types of relays are
available:
Advantages of reducing relay
with timer: Reduction of supply voltage
— lamp start always at 100% Voltage reduction via transformers or
(stipulation of lamp manufacturers) electronic assemblies
9.22
9 Appendic | Light Solutions Center – LSC
The technology and design of luminaires are We would be pleased to welcome you as our guest and offer
processes that are continually in a state of devel- you training options in the field of lighting designed to your
opment. The Osram Light Solutions Center at specific requirements. Become inspired by light and its
Traunreut in Germany accompanies these unlimited possibilities for creativity.
processes.
It is a forum for our guests, customers and partners, Simply speak to your sales representative. We can organise
in fact for all those who value good light. your personal training programme selected from our wide
spectrum of training components, and can also organise the
The Light Solutions Center offers scope for technology, entire planning from arrival until departure.
know-how, dialogue and inspiration – the experience of light
and transfer of knowledge under one roof. We present our
products and their unique light effects in an unusual and Find out more about:
stimulating way: Experience lighting and tools for light in — energy-efficient solutions for indoors and outdoors with
the context of their specific application sectors. Practically, the aid of innovative lighting systems
competently and solution–oriented, ranging from single com- — the contribution of daylight systems, lighting control
ponents such as ECGs, light engines and control software to and LED towards ergonomics, safety and environmental
completely integrated LED luminaires for professional applica- compatibility
tions. — lighting solutions for special applications such as offices,
retail spaces, industry, roads and public plazas
We offer you a versatile and exciting range of experiences — design possibilities with light
that all have one thing in common: transforming the infinite — current standards and their consequences for lighting
facets and fascination of light into reality and to concisely design
explain the individual components that contribute to this.
9.23
Appendic | Light Solutions Center – LSC 9
It’s unique: the Siteco luminaire test road in Traunreut, During the day the area looks like a loading dock. Four
Germany. There are only two types of facilities of this kind movable, crane-like portals border the road. Many different
in the world, and around 75 tests and presentations take outdoor luminaires have been installed to the lifting bar of
place each year. 2500 visitors from around the world gain the portals, ranging from obsolete solutions as found very
an impression of the benefits from improved safety with road often in real-life to the latest Siteco solutions featuring LED
traffic. technology.
A visit to the luminaire test road is especially interesting for The difference quickly becomes apparent with this com-
representatives of public administrations and power authori- parison with the presentations that take place in darkness.
ties seeking on-site information about effective, cost-saving Various scenarios demonstrate how road lighting has pro-
and attractive road lighting. Institutions such as the TÜV, gressed in development, how safety is guaranteed in road
DEKRA (German certification authorities), the police and traffic and how factors such as functionality, reliability and
the federal courts also participate in the events. easy maintenance are still ensured.
9.24
9 Appendic | Materials in Luminaire Construction
Plated aluminium Plated layer of ultra-pure aluminium 99.99 % ensures optimum reflection quality
PolyButylene Terephthalate (PBT) Continuous application temperature to 135°C, high quality reflector quality due to
aluminium metallised surface with supplementary clear coat protection
Secondary reflectors
Polyphenylene sulphide (PPS) Continuous application temperature 180°C, high-quality reflector quality with
metallised aluminium surface
Silicate glass machine-hardened Safety glass, resistant to temperature changes according to quality to 250°C, Optical
with fracture breaks into crumbs enclosures
Silicate glass chemically-hardened Safety glass resistant to temperature changes with high mechanical
rigidity. Lancets occur with fracture. Protective grid required when parts
can fall during damage.
Ceramic glass Resistance to temperature changes, with high mechanical rigidity.
Used in temperatures higher than 250°C,
loadable to 600°C
Polycarbonate (PC) Impact-resistant plastic, resistant to temperature changes to 130°C. Yellowing and
embrittlement with UV loads. Yellowing can be delayed with integrated or
applied UV baffles (factor 10 coating)
Polymethylmethacrylate (PMMA) Best optical properties of all photometric materials,
is UV-resistant, loadable to 90°C and features very good
resistance to weather and ageing.
Silicone good form stability, loadable to 230°C Sealings
EPDM loadable to 80°C
Felt loadable to 90°C, breathable
Silicone loadable to 170°C/200°C, mechanically loaded/unloaded cables
EVA loadable to 130°C
Heat-resistant PVC loadable to 105°C
Standard PVC loadable to 90°C
9.25
Appendic | Materials in Luminaire Construction 9
9.26
9 Appendic | Colours and Surfaces
9.27
Appendic | Colours and Surfaces 9
RAL 9005 black*) RAL 9006 metallic grey*) RAL 7035 light grey*) DB 701
RAL 9010 pure white RAL 9007 grey aluminium*) Siteco® metallic grey *),**) RAL 3005 burgundy*)
(similar to DB 702)
*) colour tables shown may deviate from original colour tones due to
printing conditions.
**) unprinted small metallic grey components additionally achieve a
rough glossy, structured surface.
9.28
9 Appendic | General Business Conditions and Guarantee Declarations
13 Guarantee declarations
The guarantee regulations for OSRAM products are The guarantee declarations for LED components in
specified at Siteco luminaires are specified at
http://www.osram.de/osram_de/tools-und-service/services/ www.siteco.com/de/service/garantie/
osram-garantien/index.jsp garantieerklaerung.html
9.29
Appendic | General Business Conditions and Guarantee Declarations 9
9.30
9 Appendic | Sales
Marcel-Breuer-Strasse 6 Georg-Simon-Ohm-Strasse 50
80807 Munich, Germany 83301 Traunreut, Germany
Tel. +49 89 6213 0 Tel. +49 8669 33-0
Fax +49 89 6213 2020 Fax +49 8669 33-397
www.osram.com www.siteco.com
OSRAM GmbH
Marcel-Breuer-Strasse 6
80807 Munich, Germany
Phone +49 89-6213-0
Fax +49 89-6213-2020
www.osram.com
Customer-Service-Center OSRAM
(KSC) Deutschland:
Parkring 33
85748 Garching
Phone +49 89 6213 6000
Fax +49 89 6213 6001
Head office:
Georg-Simon-Ohm-Strasse 50
83301 Traunreut, Germany
Phone +49 8669 33-0
Fax +49 8669 33-397
www.siteco.com
Customer-Service-Center Siteco
Produkttechnik:
Phone +49 8669 33-844
Fax +49 8669 865 32-944
technicalsupport@siteco.de
Member of