4. No 5. Finding Description 6. Note


1 At the time of inspection, the CAAV inspector found that one net from the FWD
CARGO was missing, but then discovered that the net was stayed in the AFT
CARGO.

2 Please verify with Catering DEPT about the ADDs regarding the T-divider. At the
AFT GALLEY, 3 out of 7 trolley locations are inoperative. Has the Catering dept
received any information to avoid uploading trolleys to those positions?

3 Collar broken. Fixed chụp hình sau khi


xong

4 ENG 1 RH C-duct leading edge seal detached. Ghi sổ

Page 1 of 3
VJC-MQA-F-096
FINDING LIST Iss01/ Rev00
MQA DEPARTMENT (Aircraft physical inspection CoA) 16 MAR 2023

5 Controlling DEFECTs - currently, the defects showed in the PFR but are not
indicated on the ECAM, how can we monitor them? In TSM, we can perform the test
3 times per defect, but we cannot wait until the daily check for the CRS to inspect
and sign off on them. How can VJA control this situation?

6 PLACARD about weight information of OVERHEAD BIN 1ABC missing. Ghi sổ

Page 2 of 3
VJC-MQA-F-096
FINDING LIST Iss01/ Rev00
MQA DEPARTMENT (Aircraft physical inspection CoA) 16 MAR 2023

7 Pocket magazine of seat 7A was prolapse. fixed chụp hình

7.QA/ QC’s Signature and Name 8. Certifying Staff’s Signature and


Authorization Number

Mr.Pham Tuong Duy – D.SM


Thai Ba Hoa Mr.Nguyen Hung Duy – leader
Team 3
Mr. Pham Phu Loc – CRS B1

Form VJC-MQA-F-093 Completion Guidance:


Block 1: Entry the Aircraft Registration
Block 2: Entry the C of A Inspection Date
Block 3: Entry the Station where perform C of A Inspection
Block 4: Entry the finding number
Block 5: Entry the Finding Description
Block 6: Entry the notify for more detail
Block 7: Entry QA/ QC’s Signature and Name
Block 8: Entry Certifying Staff’s Signature and Authorization Number