Nominal data

Type D2E146-AP47-02
Motor M2E068-EC

Phase 1~ 1~
Nominal voltage V 230 230
Frequency Hz 50 60

Type of data definition ml ml


Valid for approval / standard CE CE
Speed min-1 2050 2550
Power input W 300 330
Current draw A 1.31 1.45
Motor capacitor µF 8 8
Capacitor voltage VDB 400 400
Capacitor standard P0 (CE) P0 (CE)
Min. back pressure Pa 200 400
Max. ambient temperature °C 30 25
ml = max. load · me = max. efficiency · rfa = running at free air · cs = customer specs · cu = customer unit
Subject to alterations

Item no.: 10542-5-9980 · Revision status: KM68158 · Print-out on 08/04/2011 · Y. Uhlmann (VM-TDO) · Page 1 of 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
D2E146-AP47-02 AC centrifugal fan
forward curved, dual inlet
with housing (without flange)

Technical features

Leackage current < 0.75 mA


Size 146 mm
Operation mode S1
Direction of rotation Counter-clockwise, seen on rotor
Mounting position Any
Humidity class F0
Insulation class "B"
Cable exit Axial
Condensate discharge holes None
Motor bearing Ball bearing
Mass 4.2 kg
Housing material Sheet steel, hot-dip galvanised
Material of impeller Sheet steel, hot-dip galvanised
Motor protection Thermal overload protector (TOP) wired internally
Product conforming to CE; EN 60335-1
standard
Surface of rotor Partially cast in aluminium
Type of protection IP 44
Protection class I
Max. permissible ambient + 80 °C
motor temp. (transp./ storage)
Min. permissible ambient - 40 °C
motor temp. (transp./storage)
Approval CCC

Item no.: 10542-5-9980 · Revision status: KM68158 · Print-out on 08/04/2011 · Y. Uhlmann (VM-TDO) · Page 2 of 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
D2E146-AP47-02 AC centrifugal fan
forward curved, dual inlet
with housing (without flange)

Product drawing

1 Connection line PVC, 4x brass lead tips crimped

Connection screen

U1 blue Z brown U2 black


PE green/yellow

Item no.: 10542-5-9980 · Revision status: KM68158 · Print-out on 08/04/2011 · Y. Uhlmann (VM-TDO) · Page 3 of 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
D2E146-AP47-02 AC centrifugal fan
forward curved, dual inlet
with housing (without flange)

Charts: Air flow 50 Hz Y


Druck psf [Pa]für Rho=1,2kg/m^3

qv[cfm]
0 100 200 300 400 500 600 700 800
560
2,2
540
520 2,1

500 2
480 Measurement: LU-32744
1,9
460 Air performance measured as per ISO
4 1,8
5801 Installation Category A. For detailed
440
information on the measuring set-up,
420 1,7
please contact ebm-papst. Suction-side
400 noise levels: LwA measured as per ISO
1,6
3 13347 / LpA measured with 1m distance to
380
1,5
fan axis. The values given are valid under
the measuring conditions mentioned above
360
1,4
and may vary according to the actual
340 installation situation. With any deviation
1,3
from the standard set-up, the specific
320 values have to be checked and reviewed
2

p sf _E[IN H2O]
300 1,2 with the unit installed.
psf [Pa]

280
1,1
260
1
240
220 0,9
1
200 0,8
180
0,7
160
0,6
140
120 0,5

100 0,4
80 0,3
60
0,2
40
psf [P

20 0,1
a]

0 0
0 100 200 300 400 500 600 700 800 900 1.000 1.100 1.200 1.300 1.400
qv[m^3/h]

Measured values
Conn. U f n P1 I qv psf
V Hz min-1 W A m3/h Pa
1 Y 230 50 2050 300 1.31 970 200
2 Y 230 50 2265 267 1.18 830 300
3 Y 230 50 2490 232 1.02 635 380
4 Y 230 50 2675 191 0.84 365 440

Item no.: 10542-5-9980 · Revision status: KM68158 · Print-out on 08/04/2011 · Y. Uhlmann (VM-TDO) · Page 4 of 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
D2E146-AP47-02 AC centrifugal fan
forward curved, dual inlet
with housing (without flange)

Charts: Air flow 60 Hz Y


Druck psf [Pa]für Rho=1,2kg/m^3

qv[cfm]
0 100 200 300 400 500 600 700
740
720 2,9
700 2,8
680
2,7
660
2,6
640 4 Measurement: LU-32745
620 2,5
600 2,4 Air performance measured as per ISO
580 5801 Installation Category A. For detailed
2,3 information on the measuring set-up,
560 3 please contact ebm-papst. Suction-side
2,2
540 noise levels: LwA measured as per ISO
520 2,1 13347 / LpA measured with 1m distance to
500 2 fan axis. The values given are valid under
480
2 the measuring conditions mentioned above
1,9 and may vary according to the actual
460
1,8 installation situation. With any deviation
440 from the standard set-up, the specific
420 1,7 values have to be checked and reviewed
1

p sf _E[IN H2O]
400 1,6 with the unit installed.
psf [Pa]

380 1,5
360
1,4
340
320 1,3
300 1,2
280 1,1
260
1
240
220 0,9
200 0,8
180 0,7
160
0,6
140
120 0,5
100 0,4
80 0,3
60
0,2
psf [P

40
20 0,1
a]

0 0
0 100 200 300 400 500 600 700 800 900 1.000 1.100 1.200 1.300
qv[m^3/h]

Measured values
Conn. U f n P1 I qv psf
V Hz min-1 W A m3/h Pa
1 Y 230 60 2550 330 1.45 700 400
2 Y 230 60 2770 300 1.36 550 475
3 Y 230 60 2975 277 1.28 390 550
4 Y 230 60 3095 260 1.22 210 625

Item no.: 10542-5-9980 · Revision status: KM68158 · Print-out on 08/04/2011 · Y. Uhlmann (VM-TDO) · Page 5 of 5

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone: +49(0)7938/81-0 · Fax: +49(0)7938/81-110 · info1@de.ebmpapst.com · www.ebmpapst.com