Airstair Description and Troubleshooting
Airstair Description and Troubleshooting
Basic description:
- Door:
o In normal mode 2 dc motors operate together
o In standby mode 1 dc motor operate alone
o Open door limit switches
o Closed door limit switches
- Rail assembly is the fixed part inside the fuselage
- Carriage, steps (normal mode: 1 ac motor, stand-by mode: 1 dc motor)
- Control system: from outside and from attendant panel
- Switches
- S14 maintenance switch: it bypasses S1, S2 (handrails) and S11(lower ladder closed switch) so be
sure that handrails and lower ladder are lock during retraction. Single operation, reset when the
airstair is fully retracted.
- If the forward entry door is closed the internal control panel will not work
- If the #1 eng run relay is energised the airstair controls will not work
- If the lock pin moves this does not always indicate the internal microswitch has operated
- The door latch actuator has a timer that will release it after 120 seconds
- If standby switch on external panel does not spring back you will drain the battery
- RA913 Full troubleshooting flowchart
- Open door limit switches inop: the motors continuously run and the airstair doesn’t extend
- Closed door limit switches inop: the airstair operating light on the attendant panel remains
illuminated