Professional Documents
Culture Documents
Product Data Sheet Atx Feled Series Nonmetallic Led Luminaires English en Us 191260
Product Data Sheet Atx Feled Series Nonmetallic Led Luminaires English en Us 191260
Features Options
• Easy to retrofit in same mounting footprint as • Can be horizontally or vertically mounted. • 3 Hours Emergency / Battery Back-Up
Appleton’s FE series nonmetallic fluorescent • Positive safety switch disconnects power available ;
luminaires. to LED’s and driver to allow maintenance in — Add suffix -E to the end of the catalog
• Full range of lumen outputs, with light hazardous locations. number. Example: FELED5CBDSADE
distribution equivalent to Appleton’s FE series • Available in 3 hour emergency version, ATEX/IECEx Certifications and Compliances
fluorescent luminaires. including built-in monthly self- test. Test • Certification Type: FELED
• Corrosion-resistant fiberglass reinforced results through multi-colored LED. — Gas: Zones 1 and 2
polyester body and hinged polycarbonate lens. • Ex e battery with plug-in connector. – Conforming to ATEX 2014/34/EU: II 2 G
• High impact resistance housing (20 Joules – • Available in 5000K and 4000K Color – Type of Protection: Ex db eb mb IIC Gb
IK10) from -30 °C to +55 °C Temperatures – Temperature Class: T6 to T5
(-22 °F to +131 °F) ambient temperature and • Meets Photobiological Requirement for Risk — Dust: Zones 21 and 22
wind profile for use in extreme offshore and Group 0 (RG0). – Conforming to ATEX 2014/34/EU: II 2 D
onshore environments. – Type of Protection: Ex tb IIIC Db
Suitable Locations – Surface Temperature: +63 °C to +85 °C
• 60,000+ hour LED life at 50 °C ambient for • For use in locations where:
years of maintenance free operation. (145 °F to 185 °F)
— Hazardous areas are designated as Zone 1
• Lightweight design, hinged cover with captive • Ambient Temperature:
and 2 – 21 and 22
screws, and terminal block wiring for easy -30 °C up to +55 °C (-22 °F up to +131 °F)
— A high degree of corrosion resistance is
installation and maintenance. required (standard)
• Contemporary, low profile design suitable for — Protection against dirt, water and moisture and -20°C up to +50 °C (-4 °F up to 122 °F)
tight spaces. is necessary (emergency)
• Standard screw-type terminal block can accept • Typical applications include: • EU Declaration of Conformity: 50317
1 to 6 mm2 wire. — Oil refineries • ATEX Certificate: LCIE 16 ATEX 3048X
• Field replaceable LED driver. — Petrochemical facilities • IECEx Certificate: IECEx LCIE 16.0038X
• Industry-leading thermal management for — Food processing plants • Index of Protection according EN/IEC 60529:
safe, reliable operation over wide temperature — Waste and water treatment plants IP66.
range. — Underground tunnels • Impact Resistance (shock): IK10
• Universal, high efficiency, drivers cover voltage — General manufacturing facilities • Photobiological Safety, IEC 62778 and
requirements for 100-240 Vac, 50/60 Hz Standard Materials IEC 62471: RG0
+/- 10%. • Housing: fiberglass reinforced polyester
• High power factor electronic ballast (>0.95). • Lens: polycarbonate
• Standard 2KV surge suppression. • Gasket: elastomer
• M20 plug or M25 plug provided. • Internal reflector: highly reflective white
• Latch assembly and elastomer gasket seals. powder coated aluminum
against water and dust ingress, IP66. • Mounting accessories available in different
• Easily accessed for maintenance using Hex or materials such as gray painted aluminum, zinc
Allen key or straight blade screwdriver. plated steel, galvanized steel or 316 stainless
• Central opening with unique patented release steel
system to prevent damage.
FELED 3 C BD S A D
Appleton Grp LLC d/b/a Appleton Group. The Appleton and Emerson logos are registered in the U.S. Patent and Trademark Office.
All other product or service names are the property of their registered owners. © 2018, Appleton Grp LLC. All rights reserved.