Professional Documents
Culture Documents
SuperCor ®
N E W G E N E R A T I O N B R I D G E S
Table of contents
1. Introduction page 1
2. Application page 3
3. Production page 4
6. Relining page 30
7. Tolerances page 31
8. Tests page 32
9. Profiles page 34
www.viacon.pl
1. Introduction
SuperCor® structures are the new generation of flexible structures made of galvanized corrugated steel plates of a very
high stiffness. To take the loads, those structures use interaction with surrounding backfill soil. The load capacity
of SuperCor® is far higher than traditional structures made of corrugated steel. SuperCor® structures are used for building
engineering objects above and under roads and railways. Spans can reach 25 m.
Average assembly time takes a few days in assistance with small crew.
The beginning of SuperCor® use dates back to the middle of 80’ in 20th century. Nowadays they have been used in many
countries all over the world, in Poland used since 2000. ViaCon group manufactures SuperCor® in Scandinavia and Poland.
ViaCon Polska has been producing SuperCor® structures since 2008 in Rydzyna, Poland.
www.viacon.pl 1.
1. Introduction
- foundations
- delivery
- assembly
- backfilling
- finishing works
- simple design due to fewer details, drawings and calculations database for standard application
of structures
2.
2. Application
SuperCor® versatile structures are used for roads and railways and industrial applications:
- bridges
- overpasses
- tunnels
- culverts
- underpasses
- pedestrian tunnels
- shelters
- underground storages
Furthermore, SuperCor® structures can be used for reinforcement and reconstruction of existing structures (bridges,
www.viacon.pl 3.
3. Production
We manufacture SuperCor® using TQM approach. Our production is certified in accordance to ISO 9001:2008 and ISO 14001:2004 .
The process of SuperCor production consists of mechanical forming of steel flat plates to the shape of corrugated curved plates which
are later hot-dip galvanized. Producing of holes, cutting is done prior to galvanizing.
Corrugated plates can be epoxy painted on request. Whole process is located indoor.
4.
3. Production
[mm]
[mm]
Fig. 2. Geometry of a SuperCor® plate (total length, i.e. multiple S=406,4 mm)
Other plate configurations are available upon request. Selection of plate thickness depends on structure shape, span, depth of cover
Before you specify any of SuperCor® structures, please take the opportunity to consult with ViaCon technical representative for advice
www.viacon.pl 5.
3. Production
Galvanized coating is metallurgically- bonded to the steel surface, providing extended service life.
In order to extend the durability of SuperCor® structures, especially in an aggressive environment, there is a possibility to apply
Corrosion protection of SuperCor® structures is made in a production plant and consists of:
SuperCor® structures are protected by hot galvanizing as a standard, with zinc coating layer according to EN ISO 1461 (table 2).
Steel plates:
≥6 mm thick 70 85
≥3 mm up to <6 mm 55 70
≥1,5 mm up to < 3 mm 45 55
Bolts, nuts, anchor bolts 35 45
Base channel 55 70
The protection of structures both by hot-dip galvanizing and epoxy paint creates ViaCoat system conformed to EN ISO 12944-5.
Paint coat thickness is controlled by EN ISO 2808. Minimum adhesion of the epoxy paint to the zinc base measured by pull - off method
shouldn’t be less than 4 MPa, and an adjacent test is conducted acc. to the norm PN-EN ISO 4624.
In order to obtain right adhesion galvanized plates are sweep blast prior to application of paint.
In order to obtain the proper protection effect, paint coatings are applied in special conditions i.e. inside of closed halls with controlled
temperature, humidity. Keeping a technological regime is crucial for successful performance of the protection system.
6.
3. Production
SuperCor® structures consist of corrugated plates and additional elements. Table 3 lists these elements.
Corrugated steel plates are joined by bolts M20 (class 8.8 ). The lengths of bolts are related to thickness of connected plates and type
of connection.
- oval - shaped
- cone - shaped
All joint elements mentioned above are delivered in marked boxes together with the structure.
a) b)
www.viacon.pl 7.
4. Design / construction
- design of foundation
SuperCor® structures are designed for all road and railway live load classes acc. to Eurocode 1 EN 1991-2 and for national standards
structures:
- determine type of dead and live load (for seismic areas specify
seismic zone)
- choose the assembly procedure (estimate the labor and the cost of assembly)
8.
4. Design / construction
4.3. Dimensioning
SuperCor® structures are dimensioned with use of Swedish design method developed by prof. Sundquist and prof. Pettersson.
They can also be designed with the use of other methods, approved by producer of the structures, e.g. CHBDC. In complex cases finite
In order to select a typical shape of a structure please use tables provides on (pages 34-44). These tables include standard shapes.
www.viacon.pl 9.
4. Design / construction
Vertical distance between top of a steel structure main barrel and top of the pavement including the pavement layer.
Vertical distance between top of a steel structure main barrel and bottom of railway sleeper.
Box structures
Minimum cover depth also depends on the thickness of the pavement layer (Gn) and should not be less than:
hc = Gn + 0,15 [m]
Other shapes
For arch, round, elliptical shapes estimated cover depth is calculated using the formula:
hc = 0,1 × B [m]
Lover cover depth is permissible when appropriate static calculations are conducted. Maximum depth of a cover is always designed
individually. For high cover depth load reduction techniques are available.
10.
4. Design / construction
Ld=38+n×762+38 [mm]
the embankment slope (Fig. 7). For beveled ends minimum X-step
is 0,18 m.
curvature (Fig. 8)
1:n
x1
1:n
x2
www.viacon.pl 11.
4. Design / construction
12.
4. Design / construction
Reinforcing ribs should be used when flexural capacity of the section is exceeded.
Reinforcing ribs:
– in haunch and crown - continuous – placed on the whole top length of the structure
In order to get a bigger capacity, space between main barrel and reinforcing ribs can be filled with concrete (EC ribs).The use of EC ribs
can be necessary for large span structures. C25/30 concrete is used as filling acc. to EN 206-1:2000. Thanks to such a sulution used for
arch structures, bigger cross sectional area is achieved, which leads to decrease of compression stresses in steel wall. For boxes,
www.viacon.pl 13.
4. Design / construction
14.
4. Design / construction
For multiple structure installations, the smallest clear spacing between adjacent structures should be sufficient for the placement
and compaction of soil (Fig. 12). The minimum spacing requirement depends upon the shape and size of structures. When the required
distance can not be achieved, space between structures should be filled with C10/15 concrete or cement stabilized soil to the level
where the distance between structures is not less than 10% of structure span. Please contact us for advice.
www.viacon.pl 15.
4. Design / construction
4.10. Foundation
SuperCor® structures with closed shapes (round, elliptical, pipe-arch) are placed on soil bedding as follows:
- top portion of the bedding should be shaped to fit to the bottom plates of a structure
- upper 15 cm layer of the bedding should be relatively loose material so that the corrugation can seat in it
SuperCor® structures with open shapes (arches, boxes) are placed on concrete footings, steel footer pads or a full steel invert.
Connection of the structure to the concrete footings is realized by the means of anchor bolts, taking the following into account:
- anchor bolts for concrete foundations to be installed in concrete footings prior to delivery of a SuperCor® structure
- anchor bolts should not stick out from the top of the footing more than 40 mm
- placing of anchor bolts should conform to assembly drawing; the allowable tolerance is ±3 mm in longitudinal direction and ±2 mm
- to minimize a risk of mistake, the location of each anchor should always be measured from the starting point (first anchor)
- parallel placement of anchor bolts on each footing and perpendicular placement of each pair of anchor bolts for individual rings
16.
4. Design / construction
SuperCor® Wall
Base channel
Steel footing
Fig. 14. Connection of SuperCor® structure with steel footer pads of a full steel invert
For design of steel footing (width, thickness, depth, erosion control etc.) please contact us for advice.
www.viacon.pl 17.
4. Design / construction
Material:
- gravel, sand - gravel mix, all - in aggregates and crushed stone can be used as bedding and backfill material
- aggregate grain size depends on size of corrugation profile; for 381x140 mm maximum size is 120 mm
- aggregate grain size should be 0-120 mm, ununiformity coefficient is Cu>5,0, curvature coefficient 1<Cc<3
- soil restrictions apply for area adjacent to a structure (please contact us for advice)
- the use of cohesive soils, organic soils and soils included permafrost is not acceptable
Placing:
- backfill material around the structure should be placed in uncompacted layers maximum 300 mm thick and then compacted
- the fill should be placed on both sides of the structure at the same time, or alternating from one side of the structure to the other side,
to keep it close to the same elevation on both sides of the structure at all times. No more than one layer difference in elevation on each
side should be allowed. Each layer must be compacted to the specified density before adding the next
- backfill material should be compacted to minimum 95% standard Proctor density – in the area of 20 cm next to the structure,
In order to increase load bearing capacity/ soil stiffness of surrounding soil geosynthetic and galvanized steel which can be used.
18.
4. Design / construction
End treatment depends on the way the ends of structure are cut. For beveled ends, slopes can be finished by paving with stones blocks,
etc. For bevel ends with gabion mattresses, waterproof solutions must be applied. Please contact us for advice.
As an alternative to concrete headwalls MSE Walls (for instance ViaWall system) or gabions can be applied.
www.viacon.pl 19.
4. Design / construction
- in order to stiffen inlet and outlet of SuperCor® structure with beveled ends
- structures with skew angles to the road axis , when skew angle on outlet and inlet
- large skews
200
Fig. 15. Example of a concrete collar on inlet and outlet of the structure
20.
4. Design / construction
4.14. Fittings
SuperCor® structures can be equipped with additional elements depending on function of the structure e.g.:
- lighting boxes
- ventilation
- technical holes
- others
www.viacon.pl 21.
4. Design / construction
4.15. Durability
of SuperCor® structures.
to EN ISO 1461.
Most common thickness of epoxy paint is 200 μm, however other thicknesses are possible. Please contact us of advice.
- aggressiveness of an environment
- application of structure
- draining solutions
- abrasion
- installation damages
- corrosion protection
- plate thickness
22.
4. Design / construction
- specify the plate thickness based on static calculations (acc. to Sundquist-Petterson method)
- specify the corrosion protection (thickness of zinc coating, paint coating, extend of painting, painting procedure)
- define annual loss of the protection layers in upper and lower part of a structure
- calculate the structure durability by considering corrosion progress over service lifetime
In cases, when the durability of SuperCor® structure is not enough, following measures can be taken :
- adjust the shape of a structure and section stiffness to allow for more corrosion reserve
Durability of the ViaCoat system is higher than sum of durability of the protection layers and can be calculated as:
SD=α * (SC+SZ)
where:
α – synergy factor (from 1,5 to 2,5) for 200 μm thick paint layer α = 1,5; for 400 μm thick paint layer α = 1,75
www.viacon.pl 23.
5. Installation and construction procedures
5.1. Delivery
SuperCor® structures are delivered to the building site with following elements:
- plates are shipped nested in bundles, complete with wall, bolts and nuts necessary for erection. Each bundle includes plates with
the same type and radius. The weight of each package not exceed 3,5 tons
- plates are color coded for easy identification, corresponding to the enclosed assembly drawing.
- outer plates with cuts (inlet and outlet of the structure) are numbered.
- bolts, nuts, anchor bolts, technical drawing, as well as assembly tools (crowbar, bolts feeder, gripper, punch) are delivered in one
separate package
- base channel for footing connection can be delivered earlier, when foundation is prepared, in separate package on request.
- all elements delivered to the building site are listed on packing list.
While unloading, each delivery should be checked in comparison with a packing list. The number of plates should be equal to the
amount listed on assembly drawing. Other elements such as: bolts, nuts, anchor bolts, base channels and assembly tools are listed
Unloading can be realized with a crane or an excavator and with use of belts. It’s not allowed to use equipment that can damage
protective layers. Make sure to adjust the carrying capacity of equipment to weight of bundles. Small damage appeared during
transport, loading and unloading could be repaired on the building site, after assembly. There is always repair paint kit delivered
24.
5. Installation and construction procedures
5.2. Assembly
Assembly of SuperCor® is quick & easy. It is important to study carefully the assembly drawing and hints before installation.
Assembly drawing presents the position of each plate in the structure area and describes the assembly rules. It is necessary to follow
the assembly guide step by step. Detailed assembly instructions are delivered with each structure.
For profiles with a closed shape, placed on soil foundation, the assembly process starts after preparing the bedding.
For profiles with an open shape, placed on concrete foundation, the assembly process starts after making concrete foundation with
fixed anchor bolts. Anchor bolts are used to connect base channels, which allows to mount the structure elements.
www.viacon.pl 25.
5. Installation and construction procedures
For connection of corrugated plates in SuperCor® structures bolts M20 with nuts are used. Bolts and nuts are color coded for ease
Final torque should be done after whole structure is assembled but before backfilling. Bolts should be tighten progressively and uniformly,
starting from the center of the structure towards both ends. During backfilling checks of torque should be done as the actual bolt torque
Minimum of 300 Nm, maximum of 360 Nm for structures with spans up to 7,0 m
Minimum of 360 Nm, maximum of 450 Nm for structures with spans more than 7,0 m
Control of torque.
95% of checked bolts must have required torque and the torque
26.
5. Installation and construction procedures
- hand wrenches
- power wrenches
- torque wrench
- etc.
In good weather conditions, experienced assembly crew (6-8 people) equipped with assembly tools is able to install about 50
- structure destination
- range of ribs
- etc.
www.viacon.pl 27.
5. Installation and construction procedures
During backfilling SuperCor® structure will deform developing soil - structure interaction.
The Supercor structure with surrounding soil, constitute soil - steel composite structure with soil being a major load carrying component.
w - vertical deflection
z - cover depth
28.
5. Installation and construction procedures
Structure must be checked periodically during the backfilling procedure to ensure the shape is consistent with the producer’s
recommendation.
Once one full ring of structure is assembled, preliminary shape control should be performed.
Shape checks should be carried out both during and after assembly.
It is recommended that the producer’s representative be present during erection and backfilling of the structure.
www.viacon.pl 29.
6. Relining
SuperCor® structures are also commonly used to repair old bridges where there
are no possibilities to build a new one. This method is called relining. Corrugated
steel structure is placed inside the existing structure (bridge / culvert / underpass)
and space between an old bridge / culvert and new structural plate is filled
with concrete C12.5/15. This method allows to strengthen the structures without
any traffic stops and eliminates the necessity of remaining the old structure.
The control of pouring concrete between existing structure and new steel
maximum allowed in section No. 7 “Tolerances”. In a case where so called “open” shapes will be used for relining there is a need to make
concrete footings which could be connected to existing one. Existing footings can be used also but it will require separate analysis
or expertise.
30.
7. Tolerances
Structure dimensions after torque shouldn’t be different than designed with following tolerances:
- span +2%
- rise ±2%
- length ±0.5%
Deformation of cross section after backfilling shouldn’t exceed 2% of the span measured after assembly.
Structure dimensions after torque shouldn’t be different than designed with following tolerances:
- span +2%
- length ±0.5%
www.viacon.pl 31.
8. Tests
In order to continuously improve design method we cooperate with science centers and research institutes in Europe. Effect of this
Deformations of steel structure were measured during backfilling (long term test)and under live load
Strain and deflections measurements. Live load test (Class “A” (4x200 kN/axle)
acc. to PN-85/S-10030.
acc. to PN-85/S-10030.
- Rydzyna SC-57S.
- A4 Motoway SCA-33.
32.
SuperCor® abroad tests (selected):
- Giman (Sweden) SC-56B. Strain and deflections measurements.
www.viacon.pl 33.
9. Profiles
SC-R
SC-B
SC-SA
SC-NA
SC-OA
SC-HA
34.
9. Profiles
SC-R
www.viacon.pl 35.
9. Profiles
SC-B
Type B [mm] H [mm] A [m2] Rt [mm] α [º] Rs [mm] β [º] L [mm] δ [º] Total S*
SC-1B 3 170 1 180 3,12 8 820 7,36 1 016 72,32 406 14,00 11
SC-2B 3 550 1 420 4,33 8 820 9,96 1 016 75,02 559 10,00 13
SC-3B 3 840 1 465 4,94 8 820 12,56 1 016 77,41 517 6,31 14
SC-4B 3 965 2 210 7,35 8 820 9,87 1 016 72,09 1 430 12,98 17
SC-5B 3 865 1 260 4,19 8 820 12,71 1 016 73,28 385 10,37 13
SC-6B 4 105 1 860 6,55 8 820 12,51 1 016 72,07 1 024 11,68 16
SC-7B 4 210 1 310 4,78 8 820 15,32 1 016 73,29 389 9,05 14
SC-8B 4 735 1 960 8,14 8 820 17,74 1 016 72,08 1 023 9,05 18
SC-9B 4 550 1 360 5,38 8 820 17,93 1 016 73,30 389 7,74 15
SC-10B 4 890 1 610 6,96 8 820 20,42 1 016 74,73 562 5,06 17
SC-11B 4 860 2 365 10,08 8 820 17,71 1 016 72,10 1 434 9,05 20
SC-12B 5 155 2 420 11,06 8 820 20,45 1 016 72,36 1 423 7,42 21
SC-13B 5 215 1 670 7,71 8 820 23,01 1 016 74,74 565 3,76 18
SC-14B 5 360 2 075 9,88 8 820 23,00 1 016 72,07 1 023 6,43 20
SC-15B 5 320 1 440 6,61 8 820 23,57 1 016 69,69 415 8,53 17
SC-16B 5 445 2 480 12,05 8 820 22,95 1 016 72,09 1 431 6,44 22
SC-17B 5 655 1 505 7,33 8 820 26,17 1 016 69,69 417 7,22 18
SC-18B 5 955 2 645 14,23 8 820 27,67 1 016 72,36 1 473 3,80 24
SC-19B 5 895 1 595 8,15 8 820 28,31 1 016 72,36 405 3,49 19
SC-20B 6 165 1 900 10,31 8 820 30,29 1 016 72,36 658 2,50 21
SC-21B 6 235 2 715 15,36 8 820 30,28 1 016 72,36 1 474 2,50 25
SC-22B 6 320 1 645 8,91 8 820 31,43 1 016 69,69 420 4,60 20
SC-23B 6 480 1 975 11,25 8 820 32,91 1 016 72,36 661 1,19 22
SC-24B 6 495 2 380 13,89 8 820 32,89 1 016 72,36 1 066 1,20 24
SC-25B 6 645 1 720 9,77 8 820 34,04 1 016 69,69 421 3,29 21
SC-26B 6 970 1 795 10,66 8 820 36,67 1 016 69,68 418 1,98 22
SC-27B 7 000 2 200 13,50 8 820 36,69 1 016 69,68 823 1,97 24
SC-28B 7 025 2 610 16,36 8 820 36,76 1 016 70,36 1 234 1,26 26
SC-29B 7 290 1 870 11,57 8 820 39,30 1 016 69,68 411 0,67 23
SC-30B 7 300 2 286 14,6 8 820 39,30 1 016 69,68 826 0,67 25
SC-31B 7 310 2 690 17,56 8 820 39,31 1 016 69,68 1 231 0,66 27
SC-32B 7 315 3 095 20,51 8 820 39,27 1 016 69,69 1 637 0,67 29
SC-33B 7 405 1 680 10,21 8 820 39,29 1 016 58,98 418 11,38 22
SC-34B 7 800 1 965 12,7 8 820 41,91 1 016 58,97 620 10,08 24
SC-35B 7 945 2 370 15,89 8 820 41,92 1 016 58,97 1 031 10,07 26
SC-36B 8 575 1 920 13,9 11 430 36,45 1 016 69,69 419 2,09 26
SC-37B 8 605 2 325 17,38 11 430 36,45 1 016 69,68 824 2,10 28
SC-38B 8 635 2 735 20,91 11 430 36,45 1 016 69,68 1 234 2,10 30
36.
9. Profiles
SC-B
Type B [mm] H [mm] A [m2] Rt [mm] α [º] Rs [mm] β [º] L [mm] δ [º] Total S*
SC-39B 9 145 1 940 14,64 11 430 39,49 1 016 64,31 419 5,94 27
SC-40B 9 225 2 345 18,36 11 430 39,47 1 016 64,33 827 5,94 29
SC-41B 9 310 2 750 22,11 11 430 39,47 1 016 64,32 1 234 5,95 31
SC-42B 9 810 2 105 16,9 11 430 43,55 1 016 64,31 416 3,91 29
SC-43B 9 865 2 510 20,89 11 430 43,54 1 016 64,31 823 3,92 31
SC-44B 9 920 2 920 24,94 11 430 43,54 1 016 64,31 1 234 3,92 33
SC-45B 10 460 2 285 19,42 11 430 47,58 1 016 64,32 418 1,89 31
SC-46B 10 485 2 690 23,66 11 430 47,57 1 016 64,33 824 1,89 33
SC-47B 10 515 3 100 27,97 11 430 47,59 1 016 64,32 1 233 1,89 35
SC-48B 10 895 2 355 20,6 11 430 50,09 1 016 61,63 419 3,33 32
SC-49B 10 940 2 760 25,02 11 430 50,08 1 016 61,64 825 3,32 34
SC-50B 10 990 3 165 29,46 11 430 50,10 1 016 61,63 1 230 3,32 36
SC-51B 11 645 2 530 32,3 11 430 54,66 1 016 58,96 418 3,71 34
SC-52B 11 700 2 935 28,04 11 430 54,68 1 016 58,95 823 3,71 36
SC-53B 11 750 3 345 32,83 11 430 54,67 1 016 59,07 1 232 3,60 38
SC-54B 12 270 2 745 26,46 11 430 58,73 1 016 58,96 421 1,68 36
SC-55B 12 290 3 150 36,45 11 430 58,71 1 016 58,96 827 1,69 38
SC-56B 12 315 3 555 36,45 11 430 58,72 1 016 58,96 1 232 1,68 40
SC-57B 13 028 2 830 30,73 16 430 39,39 1 454 68,70 540 1,61 39
SC-58B 13 050 3 236 36,02 16 430 39,39 1 454 68,70 946 1,61 41
SC-59B 14 092 3 071 35,61 16 430 43,75 1 454 66,85 571 1,28 42
SC-60B 14 111 3 477 41,34 16 430 43,75 1 454 66,87 977 1,26 44
SC-61B 15 020 3 168 38,38 16 430 47,62 1 454 64,95 471 1,24 44
SC-62B 15 038 3 574 44,48 16 430 47,62 1 454 64,94 875 1,25 46
SC-63B 15 579 3 845 49,46 16 430 49,39 1 454 61,12 1 130 4,19 48
SC-64B 15 748 3 994 52,12 16 430 50,10 1 454 61,12 1 232 3,83 49
www.viacon.pl 37.
9. Profiles
SC-SA
38.
9. Profiles
SC-SA
www.viacon.pl 39.
9. Profiles
SC-NA
Type Bmax [mm] B [mm] H [mm] A [m2] Rt [mm] α [º] Rs [mm] β [º] δ [º] Total S*
SC-1NA 8 000 7 994 3 594 23,53 9 930 10,06 3 430 87,29 2,32 30,0
SC-2NA 9 000 8 983 3 760 28,15 9 930 18,95 3 430 84,57 4,04 33,0
SC-3NA 9 500 9 455 3 956 31,54 9 930 23,43 3 430 84,81 6,53 35,0
SC-4NA 10 000 9 967 3 961 33,14 9 930 27,95 3 430 81,68 5,66 36,0
SC-5NA 10 000 9 740 4 547 38,93 9 930 27,95 3 430 91,66 15,64 39,0
SC-6NA 10 500 10 476 3 974 34,75 9 930 32,52 3 430 78,49 4,75 37,0
SC-7NA 11 000 10 947 4 193 38,53 9 930 37,14 3 430 78,54 7,11 39,0
SC-8NA 11 000 10 697 4 776 44,86 9 930 37,14 3 430 88,52 17,09 42,0
SC-9NA 11 500 11 462 4 221 40,27 9 930 41,82 3 430 75,15 6,06 40,0
SC-10NA 12 000 11 974 4 259 42,02 9 930 46,58 3 430 71,71 5,00 41,0
SC-11NA 12 000 11 781 5 639 57,10 9 930 33,17 4 430 86,19 12,78 47,0
SC-12NA 12 500 12 447 4 501 46,26 9 930 51,42 3 430 71,44 7,15 43,0
SC-13NA 13 000 12 964 4 553 48,18 9 930 56,37 3 430 67,71 5,90 44,0
SC-14NA 13 000 12 745 5 890 64,39 9 930 44,22 4 430 81,68 13,79 50,0
SC-15NA 13 500 13 479 4 612 50,12 9 930 61,43 3 430 63,80 4,52 45,0
SC-16NA 14 000 13 958 4 877 54,88 9 930 66,63 3 430 63,03 6,35 47,0
SC-17NA 14 000 13 872 6 543 75,91 9 930 40,84 5 430 78,37 8,79 54,0
SC-18NA 14 500 14 433 5 150 59,87 9 930 71,99 3 430 62,03 8,03 49,0
SC-19NA 15 000 14 960 5 232 62,15 9 930 77,53 3 430 57,42 6,19 50,0
SC-20NA 15 000 14 780 7 022 87,32 9 930 54,77 5 430 74,17 11,56 58,0
SC-21NA 15 500 15 441 5 520 67,55 9 930 83,31 3 430 55,84 7,50 52,0
SC-22NA 16 000 15 942 4 922 64,47 13 930 51,60 3 430 71,65 7,45 52,0
SC-23NA 16 000 15 870 6 666 89,41 13 930 35,20 5 430 81,28 8,88 59,0
SC-24NA 16 500 16 406 5 168 69,78 13 930 54,65 3 430 72,18 9,51 54,0
SC-25NA 17 000 16 930 5 224 72,02 13 930 57,74 3 430 69,33 8,20 55,0
SC-26NA 17 000 16 909 6 720 94,96 13 930 42,37 5 430 76,38 7,57 61,0
SC-27NA 17 500 17 451 5 285 74,29 13 930 60,88 3 430 66,38 6,82 56,0
SC-28NA 18 000 17 921 5 547 80,14 13 930 64,08 3 430 66,65 8,69 58,0
SC-29NA 18 000 17 886 6 999 104,17 13 930 49,67 5 430 73,46 8,30 64,0
SC-30NA 18 500 18 447 5 617 82,59 13 930 67,32 3 430 63,48 7,14 59,0
SC-31NA 19 000 18 912 5 889 88,82 13 930 70,63 3 430 63,51 8,83 61,0
SC-32NA 19 000 18 926 7 099 110,10 13 930 57,22 5 430 68,07 6,68 66,0
SC-33NA 19 500 19 448 5 968 91,46 13 930 74,01 3 430 60,07 7,08 62,0
SC-34NA 20 000 19 924 6 250 98,10 13 930 77,47 3 430 59,83 8,57 64,0
SC-35NA 20 000 19 919 7 424 120,17 13 930 65,05 5 430 64,47 7,00 69,0
SC-36NA 20 500 20 455 6 339 100,94 13 930 81,01 3 430 56,06 6,57 65,0
SC-37NA 21 000 20 937 6 630 107,96 13 930 84,65 3 430 55,44 7,77 67,0
SC-38NA 21 000 20 892 8 462 144,33 13 930 65,73 6 430 64,56 7,43 75,0
40.
9. Profiles
SC-NA
Type Bmax [mm] B [mm] H [mm] A [m2] Rt [mm] α [º] Rs [mm] β [º] δ [º] Total S*
SC-39NA 21 500 21 419 6 926 115,24 13 930 88,40 3 430 54,59 8,79 69,0
SC-40NA 22 000 21 923 5 917 104,20 18 930 58,47 3 430 69,36 8,60 68,0
SC-41NA 22 000 21 856 8 256 151,51 18 930 42,89 6 430 76,23 7,68 77,0
SC-42NA 22 500 22 385 6 174 111,18 18 930 60,60 3 430 70,23 10,53 70,0
SC-43NA 22 999 22 896 6 945 129,33 18 930 58,36 4 430 69,58 8,76 74,0
SC-44NA 23 000 22 832 8 911 170,68 18 930 44,77 6 930 76,55 8,94 82,0
SC-45NA 23 500 23 418 7 014 132,55 18 930 60,64 4 430 67,47 7,79 75,0
SC-46NA 23 996 23 880 7 275 140,31 18 930 62,94 4 430 67,80 9,27 77,0
SC-47NA 24 000 23 872 8 994 178,19 18 930 49,99 6 930 72,80 7,80 84,0
SC-48NA 24 500 24 412 7 343 143,54 18 930 65,27 4 430 65,46 8,09 78,0
SC-49NA 25 000 24 936 7 414 146,79 18 930 67,64 4 430 63,06 6,88 79,0
SC-50NA 25 000 24 858 9 292 190,75 18 930 55,31 6 930 70,57 8,22 87,0
SC-51NA 25 500 25 410 7 685 155,09 18 930 70,03 4 430 63,17 8,19 81,0
www.viacon.pl 41.
9. Profiles
SC-OA
Type Bmax [mm] B [mm] H [mm] A [m2] Rt [mm] α [º] Rs [mm] β [º] δ [º] Total S*
SC-1OA 9 320 9 311 4 542 34,04 5800 27,77 4300 78,76 2,64 36
SC-2OA 9 298 9 061 5 328 41,30 6600 17,46 4300 94,74 13,47 40
SC-3OA 9 538 9 518 4 651 35,92 6100 30,19 4300 78,76 3,85 37
SC-4OA 9 516 9 328 5 245 41,50 6400 25,19 4300 89,41 12,01 40
SC-5OA 9 835 9 817 4 760 37,87 6200 33,42 4400 76,99 3,71 38
SC-6OA 9 889 9 665 5 546 45,67 6600 24,44 4500 90,60 12,81 42
SC-7OA 10 210 10 166 5 024 41,90 6800 30,50 4500 80,40 5,66 40
SC-8OA 10 186 9 754 5 739 49,53 7700 26,97 4300 94,74 18,23 44
SC-9OA 10 523 10 514 4 618 39,65 8300 27,82 4300 78,76 2,67 39
SC-10OA 10 604 10 493 5 232 46,00 7500 33,84 4400 82,20 9,12 42
SC-11OA 10 525 10 200 5 937 52,21 6400 43,19 4600 83,67 15,26 45
SC-12OA 10 829 10 821 4 728 41,69 8200 30,97 4400 76,99 2,48 40
SC-13OA 10 802 10 632 5 317 48,03 8000 34,62 4300 84,08 11,40 43
SC-14OA 10 790 10 397 6 026 54,42 6500 53,16 4500 80,40 16,99 46
SC-15OA 11 116 11 059 4 994 45,88 8400 35,74 4300 78,76 6,63 42
SC-16OA 11 083 10 890 5 403 50,22 8300 36,17 4300 84,08 12,17 44
SC-17OA 11 141 10 695 6 329 59,11 6700 51,59 4700 81,91 17,71 48
SC-18OA 11 347 11 282 5 098 48,06 9400 29,51 4400 82,20 6,96 43
SC-19OA 11 434 11 132 5 626 54,56 9500 31,63 4300 89,41 15,23 46
SC-20OA 11 360 10 825 6 445 61,40 6700 61,91 4600 78,68 19,64 49
SC-21OA 11 698 11 642 5 189 50,29 9400 31,96 4500 80,40 6,39 44
SC-22OA 11 701 11 364 5 719 56,85 9700 33,37 4300 89,41 16,10 47
SC-23OA 11 658 11 159 6 497 64,04 8000 37,51 4800 89,80 18,55 50
SC-24OA 11 998 11 827 5 410 54,64 10000 34,68 4300 84,08 11,43 46
SC-25OA 11 994 11 668 5 844 59,37 9500 36,50 4400 87,41 15,66 48
SC-26OA 11 993 11 696 6 714 67,29 8600 21,49 5400 92,72 13,46 51
SC-27OA 12 260 12 110 5 534 57,13 10800 29,99 4500 85,50 10,49 47
SC-28OA 12 269 11 783 6 094 63,94 10500 33,04 4400 92,62 19,14 50
SC-29OA 12 291 11 902 7 006 72,32 9200 20,09 5500 95,23 15,28 53
SC-30OA 12 571 12 289 5 789 61,76 10800 34,27 4400 87,41 14,55 49
SC-31OA 12 603 12 220 6 234 66,92 11000 29,45 4700 91,68 16,40 51
SC-32OA 12 621 12 135 7 001 74,85 9 800 25,95 5 300 94,44 17,42 54
SC-33OA 12 892 12 703 5 914 64,62 13 000 23,16 4 800 89,80 11,38 50
SC-34OA 12 921 12 554 6 346 69,66 10 800 32,13 4 800 89,80 15,86 52
SC-35OA 12 941 12 347 7 279 80,12 10 500 24,23 5 400 96,97 19,09 56
SC-36OA 13 249 13 082 6 063 67,36 10 700 34,59 4 900 83,30 10,60 51
SC-37OA 13 208 12 880 6 464 72,50 11 700 27,70 5 000 90,85 14,69 53
SC-38OA 13 210 12 745 7 482 83,50 11 600 15,96 5 800 98,30 16,28 57
42.
9. Profiles
SC-OA
Type Bmax [mm] B [mm] H [mm] A [m2] Rt [mm] α [º] Rs [mm] β [º] δ [º] Total S*
SC-39OA 13 449 13 078 6 265 72,06 12 800 28,95 4 700 91,68 16,15 53
SC-40OA 13 427 13 120 6 615 75,37 12 400 24,27 5 200 91,82 13,95 54
SC-41OA 13 407 12 795 7 535 85,97 11 200 22,73 5 600 97,66 19,02 58
SC-42OA 13 742 13 214 6 277 74,10 12 700 34,64 4 400 92,62 19,94 54
SC-43OA 13 749 13 538 6 810 78,63 11 900 23,34 5 600 89,45 11,12 55
SC-44OA 13 838 13 469 7 752 89,95 11 200 16,53 6 200 95,74 14,01 59
SC-45OA 14 064 13 682 6 462 77,55 12 700 32,82 4 800 89,80 16,21 55
SC-46OA 14 066 13 612 6 965 83,52 12 200 30,36 5 200 91,82 17,00 57
SC-47OA 14 253 13 784 7 970 95,83 11 500 20,13 6 200 95,74 15,80 61
SC-48OA 14 292 13 904 6 623 80,50 12 100 36,35 4 900 87,99 16,17 56
SC-49OA 14 383 13 946 7 079 86,59 12 000 32,80 5 300 90,11 16,50 58
SC-50OA 14 440 14 023 8 194 99,18 10 800 19,28 6 500 94,91 14,55 62
SC-51OA 14 662 14 367 6 735 83,73 12 800 32,57 5 200 87,40 13,68 57
SC-52OA 14 682 14 324 7 233 89,95 12 300 30,12 5 600 89,45 14,51 59
SC-53OA 14 704 14 176 8 218 102,07 11 200 24,79 6 300 94,24 16,64 63
SC-54OA 14 917 14 537 6 892 86,54 11 000 48,38 5 000 81,66 15,85 58
SC-55OA 14 965 14 678 7 441 93,42 11 100 35,44 5 900 84,95 12,67 60
SC-56OA 14 989 14 305 8 502 108,04 11 000 29,45 6 300 94,24 18,96 65
SC-57OA 15 274 15 077 7 041 90,22 12 400 33,61 5 700 83,86 10,67 59
SC-58OA 15 316 15 048 7 534 96,62 11 200 37,19 6 000 83,55 12,15 61
SC-59OA 15 235 14 549 8 639 111,44 10 800 32,13 6 400 92,78 18,85 66
www.viacon.pl 43.
9. Profiles
SC-HA
Type Bmax [mm] B [mm] H [mm] A [m2] Rt [mm] α [º] Rs [mm] β [º] Rc [mm] γ [º] δ [º] Total S*
SC-1HA 9 000 8 724 5 168 40,67 9 930 18,95 3 430 80,53 9 930 9,56 9,57 40,0
SC-2HA 10 000 9 690 5 371 47,06 9 930 27,95 3 430 76,02 9 930 10,14 10,14 43,0
SC-3HA 11 000 10 642 5 864 56,27 9 930 33,18 3 730 73,41 9 930 10,89 10,89 47,0
SC-4HA 12 000 11 612 6 113 63,68 9 930 42,95 3 730 68,52 9 930 11,34 11,34 50,0
SC-5HA 13 000 12 662 6 460 72,07 9 930 48,24 4 130 65,88 9 930 10,58 10,58 53,0
SC-6HA 14 000 13 641 7 009 83,57 9 930 54,44 4 530 62,78 9 930 10,92 10,92 57,0
SC-7HA 15 000 14 663 7 351 92,90 9 930 64,38 4 730 57,81 9 930 10,57 10,57 60,0
SC-8HA 16 000 15 543 7 982 111,11 13 930 39,89 4 930 70,06 13 930 10,39 10,40 66,0
SC-9HA 17 000 16 478 8 483 124,98 13 930 45,03 5 130 67,48 13 930 11,10 11,10 70,0
SC-10HA 18 000 17 350 9 207 143,30 13 930 49,67 5 430 65,17 13 930 12,40 12,41 75,0
SC-11HA 19 000 18 409 9 562 155,81 13 930 53,88 5 830 63,06 13 930 11,81 11,81 78,0
SC-12HA 20 000 19 341 10 344 176,71 13 930 56,85 6 430 61,58 13 930 12,48 12,49 83,0
SC-13HA 21 000 20 341 10 922 194,68 13 930 61,33 6 930 59,34 13 930 12,48 12,49 87,0
SC-14HA 22 000 21 397 11 363 216,73 18 930 36,17 7 430 71,92 18 930 10,24 10,25 92,0
SC-15HA 23 000 22 370 11 894 236,33 18 930 38,61 7 830 70,70 18 930 10,47 10,48 96,0
SC-16HA 24 000 23 382 12 463 257,12 18 930 39,75 8 430 70,13 18 930 10,37 10,38 100,0
SC-17HA 25 000 24 374 13 016 278,59 18 930 41,83 8 930 69,09 18 930 10,43 10,44 104,0
44.
ViaCon Sp. z o.o.
SuperCor® Acrow® 700XS® - temporary bridges Woven and non-woven geotextiles Geogrids
Gabions HelCor® TC holding tanks HelCor® wells Pecor Quattro sewage system
PECOR OPTIMA® M wells ViaWall A retaining walls ViaWall B retaining walls ViaBlock retaining walls
www.viacon.pl