You are on page 1of 2
Battery Capacity Monitor — Instruction (English version) — el 20> This is a typical high precision current type battery capacity, ‘monitor also known as coulometer, designed to test the voltage, current and capacity ofa battery to help users know the state of @ battery in real time, This device has a memory function. It is suitable for mobile and portable equipment using battery power, eg, RV, Marine, Mobility Vehicles, Remote Power, Instruments, UPS etc. roa eee oleae fine [eo fe banc rer este bene cal Pan ey oi resis eae to ow Parameter Type [Max | Unie Voltage renge 80 tooo |v. Power consumption 100 [120 | ma ‘Standby consumption os | 06 | ma ‘Sleep consumption so_| 60 | wa Voltage accuracy #10 % Current accuracy #10 * ‘Capacity accuracy #10) % Paget Parameter Min | Type | Max | unit Capacity ange 10 999 | Ah Current range (Soa) | 00 | 500 | 750| A Current ange (100A) | 00 | 1000 | 2000] A Current range (50a) | 00 | 3500 | sooo] A Temperature range o | 2» | 3 Backlight on current S0/100/150 mA, Backlight off current 30/80/30 mA Weight 200/270/410 @ Meter size 859 (diameter)20 (depth)|_mm Panel Cutout (05450 (diamete) | -mm V presen voltage ‘Ac present cent battery symbol ‘Aprsontcapacty charge indicator acharge iniatr ele value Normal Operation: > Press @ kay to vloge intrace. > Press @ key to capctyiertce > press @ ley acento crentierce > Press @ keytocapcty percentage nec, 1. First connect the current sampler/shunt in series with negative pole of battery, the B- terminal on the shunt connects to ‘the Battery - (neg) terminal. P- on the shunt connects to power ‘output/eharger - 2.. You require a standard insulated wire (03-0.75mm*). One end of the standard wire connects to the Battery + (Pos) terminal and the another end connects to any one of B+ on the current shunt. 3 Finally, connect the shunt to the Coulometer display using the shielded wie/ cable (Supplied with Coulometer) Page? Pr (outputs: (charge) (outputs) “a ‘Shielded whe =@ (1) Connection diagram of SOA current sampler Cs Pe (outputs? Sampler c- (charge-) ep —_ eS ) ( wire =®@ (2) Connection diagram of 1008/3504 shunt 4. Connect and check the reading. Complete the connection as shown and power on, the screen should display the battery voltage current, capacity percentage and other information. I the screen does not display, then please check the wire connections. Next step, run a charge or discharge and check display current is consistent with actual current. If the difference is large please check the connections ‘Attention: “IVPORTANT* Please connect as illustrated. The shunt must be connected to the negative circuit, it must not be connected to the positive circuit If you wish to extend the shielded wire, you must use the same cable/wire specification. Page3 Cut a round opening (954.50mm) to suit the display dimensions. Insert the Coulometer from the front of the panel , Then fix the CCoulometer with bracket. As shown below: Bracket Sy Panel 1. Set the rated capacity Determine the rated capacity of battery, expressed in Amp-hours, ‘¢g. 100 Ah. If your battery does not state @ amp hour rating on it, ‘contact the manufacture and ask them what Its or use this meter ‘to measure actual capacity by yourself (Please refer to below Note section). press © kayo capacty reading interface hold the key @ for3 seconds and enter eapacy setting mode press @or @ ey to Increase or decease the vlue, set the capacty equal 10 rated capacity, press © to complete the setting Note: If you find the rated capacy does’ t match the actual battery capacy, you can measure the actual capacty by ths meter Set the rated capacky as high 85 possible for example oan, Then discharge the battery totaly press @ key to percentage reading interface, hold the key @ or 3 seconds to Sette capacy to zero. Net, charge the batery fly, then the deployed capacy is the actual capac, Fnaly set the rated capncy equal to the dipayed capaci (lease refer to above section Pages 2. Capacity initialization: 1 fist use, the percentage and capacity depayed Is not the actual cortec value, you shoud itiaize the capacity : charge the battery fully press ® key to percentage reading Interface, and hold the @ key for 3 seconds to set the capacity full Alternatively, dscharge the battery totally and hold the © key for 3 seconds to set capacity zero. The coulometer is now Calibrated, no need to repeat tis exeptif you replace the battery 3, Preset voltage setting (capacity automatic zero resetting): press@® ey to voltage renting interoce, press @ key for 3 seconds to ener zero caacty votage sting interac, cick @ or © kay to cease or decease the valve, press @ to Complete the sting. When the vltage i lower than this value the An and percentage reading wil be reset to 0 and the backight wil tum of Note: Its not mandatory to set this voltage values. The default is (0, which isthe invalid /not set value Ifyou want to set this values, please ensure you understand the actual charge and discharge voltages ofthe batteries before proceeding Gamera 1. When charging or discharging, the coulometer must be ‘operational, otherwise the capacity displayed will not be accurate, 2 . Connect the load, if the discharge current is higher than “backlight on current”, the display backlight will tur on (if backlight is blinking, the B- and P- ate inversely connected) indicating thatthe load is discharging, 3 . Disconnect the load, and connect the charger. When the charge current is higher than “backlight on current”, the backclight willbe blinking (ifthe backlight s solidly on the 8- and P. are inversely connected) indicating thatthe battery is charging Pages 4. When the charge or discharge curent value lower than backlight off current’, the coulometer enters a low power state and baclclight off. Besides, the coulometer will mernory the capacity. 5S. Because of high sensitivity, when the coulometer is in standby mode (battery has no input or output current) if itis interfered by electromagnetic radiation (open or close inductive loads, such as a electric motor, the back light will shortly open. 6. When the current drastic change frequently the date acquisition may produce error, anit wil affect the accuracy The monitor must not be exposed to direct Sunlight for long periods of time or to an environment with large amounts of Ultraviolet radiation, particular in winter (< -20°C) and summer (60°C), otherwise it wll shorten the if of LD elsplay. ‘ALIS warrants each AILIB brands Battoy Capacity Monitor sold by AUB or any ofits authorized dealers or dstibutors wordwid, to be ‘rae of defects from the date of sale for 12 month. The warranty period starts at the time of purchase. For futher warranty detals refer to our website Pages

You might also like