You are on page 1of 4

FLAME RETARDANT INSULATION

European Standard (EN 13501 - 1)


German Standard (DIN 4102 - 1 , B1 Class)
Pass toxicity test (Airbus Industries Test Method)

INABA DENKO REFRIGERANT PIPE

Singapore Embassy Menara Karya Office Garuda Maintenance Facility Siemens Indonesia Arkadia
VRV / VRF VRV / VRF VRV / VRF VRV / VRF

Prudential Tower Centennial Tower District 8 Ciputra World 2 Office


VRV / VRF VRV / VRF VRV / VRF & Apartment - VRV / VRF

Pakubuwono Residence City Home Apartment Eminence Dharmawangsa Central Park Apartment

SCBD Suites The Summit Apartment Cambridge Apartment - Medan Verde Apartment

PT. Berkah Esa Perkasa Email: sales@berkah-ep.co.id


Website: www.berkah - ep.co.id Telepon: (021) 4584-1326
INSULATED COPPER TUBES
FOR AIR CONDITIONER PARCOIL • NEOCOIL

CHEMICAL COMPOSITION
• Copper Tube Material
ITEM COPPER (%) PHOSPHOR (%)
Phosphorus Deoxidized Copper
Seamless Tube (ASTM B280, Copper 99.90 or
Alloy UNS C12200) / JIS H3300 Standard 0.015 - 0.040
higher

• Pressured tested up to 1,500 psi INABA


DENKO 99.96 0.02

• Flame Retardant Water


Thermal Tensile Thickness
(European Standard EN - 1350 - 1, German Item Conductivity Strength
Absorption
Shrinkage Ratio
Standard DIN 4102 - 1 , B1 Class), and UL - 94 HF - I. Volume
(23±5° Celcius) (N/cm2) (23±5º Celcius)
(g/100cm2)
NON - TOXIC
Standard ≤ 0,043 W/m.K ≥ 14 ≤ 2,0 ≤7%
• Insulating Material
Chemical Cross-linked foam polyethylene with
expansion factor 30 times (JIS A9511 A-PE-2) INABA DENKO 0,037 48,2 0,06 2%

• Emboss Film Operational Temperature = -40 to 120ºCelcius


Insulation surface is coated with textured
polyethylene

SAFETY Relevant Safety Standards

SUPERIOR FLAME RETARDANT DEW FORMATION


QUALITY CONTROL INSULATION PREVENTIVE PERFORMANCE

INABA DENKO insulation copper INABA DENKO insulation are flame


tube and pipe conforms to current retardant and conforms to the most
safety and performance standard strict flame retardant standard
for copper pipe and insulation Relevant standard :
Relevant standard : • European Standard ( EN 13501-1)
• American Standar • German Standard (DIN41021, B1
(ASTB B280 UNS NO.C12200) Class)
• Chemical Composition & temper • Airbus toxicity Standard (AITM
• Japanese Standard 2.0007A & AITM 3.0005)
(JIS H3300 C1220T) • UL - 94 HF - I

QUALITY High Quality Materials

EXCELLENT WEAR RESISTANT


THERMAL RESISTANCE OUTER COVERING

All insulated tube and pipe Tough embossed outer covering is


products are fabricated with high easy to tape and prevent damage
grade insulation with thermal during installation.
resistance up to 120°C
In addition, PE foam has good
pressure resistance and it is
not easy to tear !

FUNCTION Upgrade Working Efficiency

IMPROVED INSTALATION LENGTH MARKINGS


EFFICIENCY

• Easy to bend and cut For 20m & 30m coils, consecutively numbered length marking are clearly printed
• Paircoil (PC) can easily be at 1 meter intervals on insulation surface
separated by hand.
• No tools or cutting necessary
INSULATED COPPER TUBES
FOR AIR CONDITIONER PARCOIL • NEOCOIL

PC PAIRCOIL

Applicable Refrigerant
R22, R32 & R410A

PAIRCOIL 20m & 30 m


Copper Tube Insulation Thickness
Item No Copper Thickness (mm)
(O.D. X Length) (mm)
PC-2320U-JE 1/4 x 3/8 x 20m 0.61 x 0.61 8x8

PC-2330U-JE 1/4 x 3/8 x 30m 0.61 x 0.61 8x8

PC-2420U-JE 1/4 x 1/2 x 20m 0.61 x 0.61 8 x 10


PC-2430U-JE 1/4 x 1/2 x 30m 0.61 x 0.61 8 x 10
PC-2520U-JE 1/4 x 5/8 x 20m 0.61 x 0.8 8 x 10
PC-2320-JE 1/4 x 3/8 x 20m 0.8 x 0.8 8x8
PC-2330-JE 1/4 x 3/8 x 30m 0.8 x 0.8 8x8

PC-2420-JE 1/4 x 1/2 x 20m 0.8 x 0.8 8 x 10

PC-2430-JE 1/4 x 1/2 x 30m 0.8 x 0.8 8 x 10


PC-2520-JE 1/4 x 5/8 x 20m 0.8 x 1.0 8 x 10

NC NEOCOIL

Applicable Refrigerant
R22, R32 & R410A

NEOCOIL - 20m

Copper Tube Insulation Thickness


Item No Copper Thickness (mm)
(O.D. X Length) (mm)

NC-220-JE 1/4 x 20m 0.8 8

NC-320-JE 3/8 x 20m 0.8 8

NC-420-JE 1/2 x 20m 0.8 10

NC-520U-JE 5/8 x 20m 0.8 10

NC-620U-JE 3/4 x 20m 1.0 10


INSULATED COPPER TUBES
FOR AIR CONDITIONER NH PIPE

NH NH PIPE

Applicable Refrigerant
R22, R32 & R410A

NH PIPE - 4m

Copper Tube Copper Thickness Insulation Thickness


Item No Temper Grade
(O.D. X Length) (mm) (mm)

NH - 740 - JE 7/8 x 4m 1 H 10

NH - 840 - JE 1 x 4m 1 H 10

NH - 940 - JE 1 1/8 x 4m 1 H 10

NH - 1040 - JE 1 1/2 x 4m 1.1 H 10

NH - 1140 - JE 1 3/8 x 4m 1.2 H 10

NH - 1240 - JE 1 1/2 x 4m 1.35 H 10

NH - 1340 - JE 1 5/8 x 4m 1.45 H 10

NH - 1440 - JE 1 3/4 x 4m 1.55 H 10

INABA DENKO ACCESSORIES FOR A/C REFRIGERANT PIPE SYSTEM


• Pipe lock

• Conventional Installation • Typical Installation with PIPELOCK

Top floor Top floor


Top floor Top floor

Thermal expansion
Support Support
Support Support
Central fixed point acts as
Weight of pipe system Thermal expansion a fulcrum to direct thermal
Aging
Aging components plus thermal expansion upwards and
expansion causes riser Fixed Fixed downwards, supporting
Support Support weight of copper pipe and
pipe to sag
Thermal expansion reducing load on elbow at
lowest floor by 50%.

Support Support
Support Support
Thermal expansion

Lowest floor Lowest floor


Lowest floor Lowest floor Cut in half of load to elbow
Buckling of elbow
at lowest floor at lowest floor

Load is transferred to lowest elbow on riser • Illustration is Line Art.


causing it to become compressed and buckled.  When using PIPELOCK, provision for thermal expansion is still required.

• Copper fittings

You might also like