D-RX 250

Combined
probe ­sensor
Single rod measurement probe for
simultaneous measurement of
- Dust concentration [mg/Nm³]
- Volume flow [Nm³/h]
- Temperature [°C]
- Absolute pressure [hPa]

Features Measuring principle

● Only one probe/ installation opening in ● The dust concentration is determined ● The absolute pressure in the flue gas is
the exhaust gas channel according to the triboelectric measuring measured by a pressure transmitter in one
● Compact design principle. The tribo probe measures the chamber of the probe.
● No moving parts electric charge of the impinging particles. ● The temperature is measured directly in
● Automatic zero and reference point check ● The measurement of the volume flow is ba- the centre of the flue gas flow in a separate
sed on the mechanical action principle. The chamber within the probe with a tempera-
Applications probe has two separate chambers, ture sensor.
between which a differential pressure
● For measurements in accordance with TI Air builds up under flow.
(Technical Instructions for Maintaining Air
­Purity), 13., 17. and 27. BImSchV
✖ Not suitable for use behind electro­static System components
precipitators. Please consult us

Approvals
probe transmitter differential control and
pressure evaluation unit
● Suitability-tested by the TÜV Cologne, transducer

test report 936/800006/A


● MCERTS

Distributor

max. 1000 m

Options
● Automatic cyclic probe back purging for
● Weather protection cover high dust concentrations
● Switch-over cock for back purging/ zero ● Hastelloy probes for corrosive gases
point control ● Purge air connection at flange
measurements dust concentration, volume flow, digital inputs 6 potential free inputs
absolute pressure, temperature
measuring ranges 0 ... 10 ... 0 ... 500 mg/Nm³ detection limit <2% of measuring range
©DURAG GROUP 07/2016 · Subject to change without notice

0 ... 9,999,999 Nm³/h 1)


0 ... 200 °C, optional 0 ... 350 °C
800 ... 1,300 hPa
measuring dust: tribo electric power supply 115/ 230 VAC, 50/ 60 Hz, 50 VA
principle volume flow: differential pressure
flue gas above dew point up to 200 °C, dimensions probes: 180 x 180 x (340 + probe
temperature optional up to 350 °C, (h x w x d) length) mm
flue gas humidity <80% probe length 250, 400, 700, 1000 mm
flue gas pressure -200 ... 200 hPa weight probe 9.5 kg
electronics 22 kg
duct diameter 0.3 ... 5 m
ambient -20 ... +50 °C probe back purge air supply 3 bar
temperature purging (option)
protection IP65 insulator purging continuous purge air supply
(option) approx. 2 m3/h
measuring outputs 4x 0/ 4 ... 20 mA/ 500 Ohm, remarks 1)
f lue gas velocity >5 m/s
Modbus RTU (RS485) concentration after gravimetric
calibration
digital outputs 7 relay outputs, permissible load
48 V/ 0.5 A

DURAG GmbH Tel. +49 (40) 554 218-0 · Fax +49 (40) 584 154
Kollaustrasse 105 · 22453 Hamburg · Germany E-Mail: info@durag.de www.durag.com