You are on page 1of 3
State: Eng Released Date: 21, Mar 2018 Time: 03:05PM f : E i ELECTRONIC METER REGISTER \on—Hazarpous AREA I (1) G [€& io Go] DA [Ex ia Go] A EMR3 (18) INTERCONNECTION 80x. BAES SERIES ceanmeare no ewko'10-aTeX 1008740%. ect UL 14.0020% SYSTEM DESCRIPTIVE DOCUMENT FOR CERTIFICATE NUMBER: DEMKO 10 ATEX 1006740X IECEx UL 14,0029X HAZARDOUS AREA RSSOGIED anPaRATUS INTRINSICALLY SAFE (15.) APPARATUS a ©) 116 ex ie TATA Go Ex ia IIA T4 Ga 12) ieee ‘TAL RELEASE eas 1/26/02 Doue- ose 1 [ADDED ieecx TO ORAWN. 8 [an14/s/a|en=07950 Ess swicH S ®) | EMERGENCY © [stor Switch DISPLAY HEAD #4 5456 SERIES CERTIFICATE, No BeaKo 10 atex 1008740" | HO Hebe UL 14.0029% KEYPAD (OPTIONAL) lee e sorcice / GROUND’ |unspeciFieD| CONNECTION | EQUIPMENT Fy THERMOPROBE wa ee NOTES; SEE PAGE 2 WIRE TABLE: SEE PAGE 2 DO_NGT_SCALE DRAWING Nawe _— | ate — | nO«t of. DESIGNER ROUTHER | 10/28/08 [asseuaLY cet PROWECT ‘BANOREW —[10/28/05_| FORM NO. MATERIAL, Qavewer-rocr ier owe @ OO __9o REMOTE DISPLAY HEAD Le ae RereRENe SYSTEM DESCRIPTIVE DOCUMENT ATEX/IECEX_EMRS D| 33S40-004 | ¢ [REL SCALE None [Suet OF ‘State: Eng Released Date: 21, Mar 2018 Time: 03:05PM Name: John Nobile ACH CABLE RUN (OR WIRING) USED TO CONRECT LS, OEVCES TO THE I MUST NOT EXCEED A RATED CAPACITANCE OF 328 pf/METER OR 100 pf/F2OT. ACH CABLE RUN MIST NOT EXCEED A RATED INDUCTANCE OF 0,656 yH/METER OR 0,2 4H/FOO™ vevereD beereD INTRINSICALLY SAFE DEVICE CONNECTIONS: CONNECT ONLY 1 ELECTRONIC METER REGSTER DISPLAY HEAD OR REMOTE DISPLAY TO THE OMI TERMINALS. CONNECT ONLY 1 ELECTRONIC M REMOTE OISPLAY TO THE. OM TERMINALS, 6. NON-HAZAROOUS AREA APPARATUS WHICH IS UNSPECIFIED EXCEPT THAT IT MUST NO” BE SUPPLED FROM OR CONTAN, UNDER NORMAL DR ABNORMAL CONDITIONS. A SOURCE OF POTENTIAL WITH RESPECT TO EARTH IN EXCESS OF 280V' RMS OR 250V de, ‘Um=25. 7. CONNECT THE BARRIER GROUND TO THE EARTH GROUND BUS AT THE POWER DISTRIBUTION PANEL WTH 4 sq mm (10 AMG) OR LARGER CONDUCTOR. GROUNDING MUST COMPLY WITH EN 6[079~14, CLAUSE. 6.3, 8. A WXMLM CABLE LENGTH OF 308 METERS OR 1,000 FEET IS ALLOWEC TO CONNECT ANY SINGLE LS. DEVICE 10 THE ASSOCIATED APPAFATUS. THE TOTAL ALLOWABLE CABLE LENGTH USED TO CONNECT ALL OF THE LS. DEVICES TO THE ASSOCIATED APPARATUS IS 610 WeTERS OR 2.000 FEET, "THE CABLE BETWEEN THE EMR DISPLAY HEAD AAD THE EMERGENCY STOP SWITCH, CORNER SWITCH, THERMOPROEE, PULSE ENCODER AND THE KEY PAD MUST BE LESS THAN 35 NETERS OR 113 FEET TOTAL” Ii ACCORDANCE WH EN 0079-25, SECTION 10, 10. THE AVEIENT TEMPERATURE RANGE FOR THE INTERCONNECT OX 1S ~25C TO 440°C. THE AMBIENT TEMPERATURE FOR THE DISPLAY HEAD, EMERGENCY STOP SWITZH, THERMOPROBE, CORNER SWITCH, ROTARY PULSE ENCODER AND KEYPAD IS a0 TO sear 11. SPECIAL CONDTIONS, SAFE USE, AS APPLICABLE AND AS DEFINED IN THE CERTIFICATE OF CONFORMITY, INSTALLATON INSTRUCTIONS ANO THE SYSTEM DESCRIPTIVE COCUMENT, 351940004, MUST BE TAKEN INTO. ACCOUNT. JHE Qu DISPLAY HEAD, REMOTE DISPLAY HEAD, KEYPAD, PULSE ENCODER, THERNCEROBE, ESS SMITCH AND CORNER SWTTCH CONTAN ALLINUM, CARE MUST BE TAKEN TO AVOD JGNTION HAZAROS OUE TO MPACT OR REGISTER DISPLAY HEAD OR ‘THE CEVICES HAVE NOT BEEN EVALUATED FOR USE ACROSS A BOUNDARY WALL, 12, THS SYSTEM DESCRPTVE DOCUMENT OESCRIEES THE INTRNSICALLY SAFE EQUIPMENT AND ASSOCATED APPARATUS THAT TOOETHER FORM AN INTRISICALLY SAFE SYSTEM 13, ERS 6 BOXES MUST, BE INSTALLED IN AN INDOOR, NON-HAZAROOUS AREA IN ACCORDANCE WITH THE DESCRIPTIVE SYSTEM DOCUMENT AND THE INSTALLATION INSTRUCTIONS, Ad ERS IB CAN BE CONNECTED TO ANY INTRINSICALLY SAFE APPARATUS AS DESCRIBED ON SHEET ONE OF THIS DOCUMENT. MULTIPLE SOURCES OF PONER, ADDITIONAL EMRS 12 BOXES OR OHER ASSOCHTED APPARATUS, CANNOT 3€ CONNECTED TO THE SME INTRINSICALLY SAFE APPARATUS, STANDARDS: fo 60079-0 ELECTRICAL APPARATUS FOR POTENTALLY EXPLOSVE ATHOSPHERES PART 0: CENERAL REOUIREMENTS, 6TH EDITION TEC 6079-11 ELECTRICAL APPARATUS FOR POTENTALLY EXPLOSWE ATMOSPHERES PART 11: INTRINSIC SAFETY ‘', 6TH EDITION IEC 6079-25 ELECTRICAL APPARATUS FOR EXPLOSVE GAS ATMOSPHERES-PART 25: INTRINSICALLY SAFE SYSTEMS, 2ND EDITION IEC 6079-26 ELECTRICAL APPARATUS FOR EXPLOSVE GAS ATMOSPHERES PART 26: EQUIPMENT WITH EQUPMENT PROTECTION LEVEL (EPL) 6, 2ND EDITON EN 60079-0 ELECTRICAL APPARATUS FOR POTENTALLY EXPLOSVE ATMOSPHERES-PART 0: GENERAL REQUIREMENTS EN 60079-11 ELECTRICAL APPARATUS FOR POTENTALLY EXPLOSVE ATMOSPHERES PART 11: INTRINSIC SAFETY" EN 60079-25 ELECTRICAL APPARATUS FOR EXPLOSVE GAS ATMOSPHERES-PART 26: INTRINSICALLY SAFE SYSTEMS EN 60079-26 ELECTRICAL APPARATUS FOR EXPLOSVE GAS ATMOSPHERES - PART 26: CONSTRUCTION, TEST AND MARKING OF GROUP ll ZONE O ELECTRICAL APPARATUS. ——— VEEDER-ROOT — {iiiillewr ocoro FOR 1.5, CABLE AND WIRE DESCRIPTIONS SEE PAGE 3 YSTEM DESCRIPTIVE, DOCUMENT ATEX/IECEX_EMRS b| 331S40-co4_|C [REL ET 5 enone [sneer 2 oF ‘State: Eng Released Date: 21, Mar 2018 Time: 03:05PM Name: John Nobile SINELE APPARATUS “THERMOPROBE ROTARY ENCODER EMR MODE SWITCH (OPTIONAL KEYPAD EMERGENCY STOP SWITCH DISPLAY HEAD oR REMOTE DISPLAY HEAD EMRS 1S. CABLE AND WIRE DESCRIPTIONS MAXIMUM LENGTH ee 7,820 mm 25 FT EXTERNAL CABLE, 2 CONDUCTOR 10,668 mm 35 FT INTERNAL WIRE, 4 CONDUCTOR 7,620 mm 25 FT 915 mm 3 FT INTERNAL WIRE, 2 GONDUCTOR INTERNAL WIRE, 7 CONDUCTOR 7,620 mm 25 FT EXTERNAL CABLE, 2 CONDUCTOR 305 METERS 1000 FT EXTERNAL CABLE, 4 CONDUCTOR REMOTE DISPLAY HEAD (BODY REMOVED FOR CLARITY) WIRING IDENTICAL TO DISPLAY HEAD WIRE TABLE 1B BOX CABLE CONNECTIONS PULSE ENCODER WIRE CONNECTIONS KEYPAD CABLE CONNECTIONS CORNER SWITCH CABLE CONNECTIONS TERMINAL SIGKAL, IRE COLOR TERMINAL SiGwAL, WIRE COLOR TERMINAL, ike coLOR TERMINAL SIGNAL WIRE COLOR 24 Pwr RED u +5v REO 02 kp2 Feo. 16 ND YELLOW 25 GND BLACK 2 GND BLACK 03 KPS ELACK 17 cos YELLOW 26 1B-B WHITE 13 cH WHITE 08 Kps ware 2 BA GREEN 4 CHa GREEN 05 KPS GREEN 06 KPS YELLOW 07 KP? BLUE ESS (OPTIONAL) SWITCH CONNECTIONS THERMCPROBE (OFTIONAL) CABLE CONNECTIONS: 8 kee ORANGE TERMINAL SIGNAL WIRE COLOR TERMINAL SIGNAL WIRE COLOR 18 np BLACK 20 e BLACK 19 ESS WHITE 21 e WHITE SYSTEM DESCRIPTIVE DOCUMENT ATEX/IECEX_EMRS b| 331S40-co4_ | C |REL Er 5 enone [Suge oF

You might also like