0% found this document useful (0 votes)
283 views1 page

Water Fountain - R1

This document appears to be a technical drawing showing reinforcement details for a concrete structure, including dimensions and callouts for rebar spacing and thickness of concrete layers. Reinforcing bars spaced at 250mm intervals are shown at various levels. Notes indicate the drawing was prepared based on site data from the contractor and vendor.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
283 views1 page

Water Fountain - R1

This document appears to be a technical drawing showing reinforcement details for a concrete structure, including dimensions and callouts for rebar spacing and thickness of concrete layers. Reinforcing bars spaced at 250mm intervals are shown at various levels. Notes indicate the drawing was prepared based on site data from the contractor and vendor.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

27350

27200

75 300 26600 300 75


300 75

1800
4750

4000

300 1200 300


4600

300
A A

1600
1000
300
75 300

TOW +7.98LVL

850
T16@250mm C/c T16@250mm C/c GL
T16@250mm C/c 1200 T16@250mm C/c
TOS +7.1LVL
300mm Thk RCC 1:2:4
100mm Thk PCC 1:5:10

900
1300

T16@250mm C/c

T16@250mm C/c
300mm Thk RCC 1:2:4
100mm Thk PCC 1:5:10

T16@250mm C/c
PROVIDE MEP PIPE OUTLETS
WHERE EVER REQUIRED AS
PER VENDOR REQUIREMENT,

THIS DRAWING IS PREPARED


BASED ON THE SITE DATA
PROVIDED BY THE

W
S
CONTRACTOR AND VENDOR.

th
ARCHITECTURAL

or
E

N
CONCURRENCE SHALL BE
REQUIRED BEFORE PROPOSED UNDER GROUND
CONSTRUCTION. COMMUTER AMENITIES
CENTRE AT SHENOY NAGAR
FOR GENERAL DETAILS REFER IT IS CERTIFIED THAT THIS DOCUMENT HAS BEEN
DWG NO. CDPL/2018/105/STR/S-01.A DESIGNED AND CHECKED IN ACCORDANCE WITH
TO S-01.C LDC QUALITY ASSURANCE PLAN

COMMUTER AMENITIES CENTER AT SHENOY NAGAR


THIS DRAWING WITH ALL ITS CONTENTS NOTES ARCHITECTS & ENGINEERS- CLIENT SUBMITTED BY STRUCTURE CONSULTANT: NO OBJECTION FROM CMRL PREPARED FULL NAME SIGNATURE
1. ALL DIMENSIONS ARE IN MM. PROJECT
IS THE SOLE INTELLECTUAL PROPERTY
W

2. DO NOT SCALE, FOLLOW WRITTEN DIMENSION ONLY. DRAWN BY KISHAN

THIS DRAWING IS THE PROPERTY OF


OF THE CONSTRUCTURE DESIGNS
3. THIS DRAWING SHALL BE READ IN CONJUNCTION
S

PVT. LTD. COPYING OF THIS WITH RELEVANT ARCHITECTURAL AND STRUCTURAL B L Kashyap & Sons Limited DESIGNED BY LALIT BHANDARI
DRAWING OR PART THEREOF,OR ITS 4. RENFORCEMENT SHALL BE TMT BARS OF GRADE 4th Floor, West Wing Soul Space Paradigm Near
Constructure Design P. Ltd. UAA 10-Proposed UG Commuter
USE IN ANY FORM WHATSOEVER fe 500D AND CONFORMING TO I.S.1786-2008. Taamaesek Engineering Consortium 3rd Floor, Abhishek Plaza, Part-1, CHECKED BY ARVIND
Innovative Multiplex Outer Ring Road, Marathahalli
N

WITHOUT THE WRITTEN PERMISSION 5. CONC. MIX SHALL BE M-30


New no. 5, Old no.2a, Bishop CHENNAI METRO RAIL LIMITED,
Bangalore 560 037 INDIA Pocket B,Mayur Vihar, Phase-2, Amenities Center at Shenoy Nagar
Wallers Avenue west, Mylapore,
E

Depot Admin Building,Poonamalle High Road, APPROVED BY U.RAVI


Chennai - 600 004. Ph : 044-24671157/1139.
Chennai 600 107,Ph:23792000
Tel: +91 80 30742400, 25235878 New Delhi - 110091 Metro Station

STRUCTURAL
R1 FOR APPROVAL KISHAN DILEEP U.RAVI 24-05-2022 Fax : 044-24672237. Fax: +91 80 25235879 tel.11.2277.6008,2272.4917 DRAWING TITLE WATER FOUNTAIN DETAIL , WATER POND DETAIL
R0 FOR APPROVAL KISHAN DILEEP U.RAVI 11-01-2020
url:www.taamaesek.com Fax:23792200,email:chennaimetrorail.com email: constructure@gmail.com.
Email: robangalore@blkashyap.com

DRG.
e-mail: info@taamaesek.com REV. SCALE STATUS

NO
CDPL/2018/105/STR/LS-01-G
REV. PARTICULAR DRN. CHD. VER. DATE R1 N.T.S. FOR APPROVAL