NOTES:

1. Basic referance code:- IS 456: 2000


14'-7" 2. Due care shall be taken to ascertain that requisite strength of concrete is gained
before commencement of deshuttering. It shall comply with provisions of

5"
13'-10" SCHEDULE OF R.C.C. COLUMNS AND FOOTINGS Clause No. 11.3 of IS 456: 2000.
3. Deshuttering period shall not be less than specified below:
a) Veritcal faces of column, beams, & wall -24hrs.
SP

2'-8" LINK
b) Slabs I) Spanning upto 4.5m. -7 days
C1 C2
DETAILS II) Spanning over 4.5m. -14 days
9"X18" 9"X18" c) Beams I) Spanning upto 6.0m. -14 days
II) Spanning over 6.0m. -21 days
COLUMN FROM

M20
4'-3"X4'-6" 4'-3"X4'-6"
8'
2ND TO ROOF 4. Nominal covers Mild Moderate Severe
BAR I Footings 50 50 50
C3 C4 SLAB LEVEL ARRANGEMENT II Columns & walls >200mm width 40 40 45
T16 (to links of column)
T12 T12 T12 III Columns & walls having width of 200mm & below 40 40 45
9"X18" 9"X18" having reinf. of dia. 16mm & above.
SIZE 9" X 18" 9" X 18" 9" X 18" (to links of column)
IV Columns & walls having width of 200mm & below 25 30 45
STEEL 8-T12 4-T16 + 4-T12 8-T12 having reinf. of dia. 12mm.
4'-6"X5'-9" 4'-6"X5'-9" (to links of column)
V Slabs 20 30 45
VI Beams 20 30 45
LINK (to stirrups of beam)
16'-3" DETAILS VII Lift wall 40 40 45

For main reinf. up to 12mm dia. bar for mild exposure the nominal cover
COLUMN FROM may be reduced by 5mm for slabs & beams only.

M20
4'-9"X5'-9" 4'-9"X5'-9" 5. Beams having depth more than 750mm, provide side-face reinforcement.
1ST TO 2ND 6. Substratum shall be approved from our office before laying P.C.C.
BAR
C5 C6 SLAB LEVEL 7. Minimum clear spacing between any two longitudinal bars in beam= 50mm.
9"X18" 9"X18"
ARRANGEMENT 8. All laps (Ld) shall be staggered & not more than 50% bars to be lapped
T16 at any given section.
T12 T12 T12 GRADE OF REINF. M20 M25 M30 M35 M40 & ABOVE
SIZE 9" X 18" 9" X 18" 9" X 18" Fe415 55 X D 47 X D 44 X D 39 x D 35 x D
Fe500 (TMT) 66 X D 56 X D 53 X D 46 x D 42 x D
7'-3" STEEL 8-T12 4-T16 + 4-T12 8-T12 9. Maximum allowable height of column without any bracer or tie
I 230 wide 4000 mm.
C7 C8 II 200 wide 3400 mm.
9"X18" 9"X18"
LINK III 150 wide 2600 mm.
DETAILS 10. All buildings shall have tie beams/plinth beams at ground/plinth level.
11. If footings overlap each other, necessary revision shall be obtained from our office.
67'-11" 12. Design is valid for number of floors as indicated in the drawing.
COLUMN FROM 13. At any level where column size gets reduced in either dimension
4'-9"X5'-9" 4'-9"X5'-9" 78' tie beams/plinth beams are essential.
M20

FOOTING TOP TO 1ST 14. For cantilevers, top bars to be anchored behind from external face of support for -
13'-6" BAR Ld or span of cantilever - whichever is greater.
SLAB LEVEL ARRANGEMENT 15. Fire rating considered:- 1 Hour Max.
T16
4'-6"X5'-9" 4'-6"X5'-9" T12 T12 T12
Use of this drawing for construction shall explicitly confirm acceptance of following conditions
SIZE 9" X 18" 9" X 18" 9" X 18" by Owner / Builder / Contractor
C9 C10
1. Our responsibility shall remain limited to safe and sound structural design as transmitted
9"X18" 9"X18" STEEL 8-T12 4-T16 + 4-T12 8-T12 by this drawing and we shall not remain responsible for
STEEL

FOUNDATION DISTRIBURION T10@6" c/c T10@5" c/c T10@5" c/c a) Safety of old structure during demolition.
b) Safety of any adjoining building /persons staying in adjoining building/persons
DETAILS MAIN STEEL T10@6" c/c T10@5" c/c T10@5" c/c and properties on adjoining roads.
M20

c) Safety of construction worker/any personnel at work site during construction


7'-5" CONCRETE MIX 4'3" X 4'6" X 18" 4'9" X 5'9" X 18" 4'6" X 5'9" X 18" d) Correctness/safety of any temporary structure, scaffolding, shuttering, centering erected at site and
SIZE OF FOOTING any injury to any personnel arising out of any accidents.
M20 GRADE 4'9" X 5'3" X 18" 5'3" X 6'3" X 18" 5'0" X 6'3" X 18" e) Accidents occurring due to premature deshuttering, faulty / substandard construction material or
C11 C12 PCC workmanship / faulty construction procedure.
9"X18" 9"X18" f) Any accident occurring due to construction of elements of buildings not designed by us.
COLUMNS NUMBER C1 ,C2 C5,C6,C7,C8 C3,4,9,10,11,12,13,14 2. Supervision if specifically asked for will be provided to the extent of verification of reinforcement on site
but responsibility regarding correct & sound construction shall solely rest with contractor/ builder / owner.
3. All structural concrete should be weigh batched, machine mixed & mechanically vibrated.
4. Any discrepancy between our drawing & Architects' drawing shall be brought to our notice before construction.
4'-6"X5'-9" 4'-6"X5'-9"

NO. REV. DATE DESCRIPTION LIVE LOAD :- 200 kg/m2

15'-6" 06-01-2020 FOR APPROVAL FLOOR FINISH :-


R0 100 kg/m2

R1 . . OTHRE :- - - - -

R2 . . S. B. C. :- 35 T/m2

R3 . . GRADE OF CONCRETE :-

C14 R4 . . FOR FOOTING :- M20


C13
FOR COLUMN :- M20
R5 . . FOR SLAB & BEAM :- M20
9"X18" 9"X18"
R6 . . GRADE OF STEEL :- Fe 500
ENVIRONMENTAL
R7 . . EXPOSURE CONDITION :- MILD
4'-6"X5'-9" 4'-6"X5'-9" JOB NO.
DGN BY DRAWN BY CHK BY APPR. BY SCALE DRG. NO. BLDG:

BUILDING 20:03

15'-9"

FOUNDATION Er.P.T.CHAVAN Er. G.G.GHORI


CREATIVE DESIGN CIVIL & CONSULTING STRUCTURAL DESIGNER &
PLAN AND
CONSTRUCTION'S
ENGG.
MOB. - +91 7020028383
CONSULTING ENGG.
MOB. - +91 8793596857