You are on page 1of 1

Architects

LINTEL DETAILS
B Client :
Top Reinft Mr. RASUL
Notes :

NOTE:
Stirrups

D
1. SOIL BEARING CAPACITY.

D
Foundations have been
designed for allowable bearing
pressure of 0.95 Tons/ Sft
2. STEEL REINFORCEMENT
Bottom Reinft a. Steel Reinforcement confirming to IS

Clear Span (L) 456:2000 code, FE - 500 grade should be


used.

General Notes :
1. All Dimensions in ft/in.
2. Dimensions to be strictly followed
3. Drawings to be Read with relevan
architectural drawings
4. use M20 Concrete
M5 = 1:4:8
M10= 1:3:6
M15= 1:2:4
M20= 1:1.5:3
M25= 1:1:2
CLEAR COVER TO MAIN
REINFORCEMENT:
1.FOOTINGS : 50 mm
2.RAFT FOUNDATION.TOP : 50 mm
3.RAFT FOUNDATION.
Clear Span (L) Breadth(B) Depth(D) Top Bottom Links/ BOTTOM/SIDES : 75 mm
4.STRAP BEAM : 50 mm
(in) (in) (in) Reinft Reinft Stirrups 5.GRADE SLAB : 20 mm
6.COLUMN : 40 mm
7.SHEAR WALL : 25 mm
8.BEAMS : 25 mm
9.SLABS : 15 mm

3' 9"/5" 4"-5" 2 -Y10 2 -Y10 4 @ 300mm c/c 10.STAIRCASE : 15 mm


11.WATER RETAINING
STRUCTURES : 20/30 mm

3' - 6' 9"/5" 5" 2 -Y10 2 -Y10 10 @ 225mm c/c


Project :
6' - 12' 9"/5" 6" 2 -Y12 2 -Y12 10 - 19 @ 200mm c/c Proposed Residential
Building

Scale : NTS

12' - 14' 9"/5" 7" 2 -Y12 2 -Y12 19 - 22 @ 200mm c/c


NOTE: LINTEL WILL BE AT 7' HEIGHT ON ALL THE WALLS. Sheet Title