You are on page 1of 14

GOING

TO
DIGOS THIS
CITY
PROPER
SITE

GOING
TO
BANSALAN

PERSPECTIVE
SITE DEVELOPMENT PLAN
VICINITY MAP
A-1
FLOOR PLAN A-2
RIGHT ELEVATION
LEFT ELEVATION A-3
DEPARTMENT OF THE INTERIOR AND LOCAL GOVERNMENT
PROVINCIAL OFFICE

FRONT ELEVATION
REAR ELEVATION A-4
LONGITUDINAL SECTION "B-B"
LONGITUDINAL SECTION "A-A" A-5
ROOF PLAN A-6
ROOF FRAMING PLAN A-7
ISOMETRIC VIEW
SEPTIC TANK
CATCH BASIN
GREASE TRAP DETAIL
A-8
STRUCTURAL CONCRETE DETAILS
MAIN TIES/STIRR
MARKS W (MM) D (MM) L (MM)
BARS UPS(MM)
6 PCS -16MM
F1 1000 300 1000 NA
bar x - bar y

C1 250 250 3000 4 PCS-16MM A

C2 250 250 3700 4 PCS-16MM A

12 MM
REFER TO
WF1 350 200 3 PCS-12 MM SPCED AT
PLAN
300 MM OC

NOTE: REFER TO
RB1 250 300 4 PCS-12 MM A
A = 10 MM; 2 @50; 4 @ 75; 6 @100 REST AT 150MMPLAN
OC

ROOF BEAM PLAN


COLUMN DETAIL
BEAM DETAIL
WALL FOOTING DETAIL
STRUCTURAL CONCRETE
A-9
DETAIL
TOP & BOTTOM BARS
TO RUN THRU JOINT

1. STRUCTURAL DESIGN CRITERIA UNINTERRUPTED

DESIGN MATERIAL STRESSES: CONST. JOINT CRITICAL SECTION

CODES AND STANDARDS SHEAR ZONE


1. CONCRETE COMPRESSIVE STRENGTH (fc') 20 MP (3000 PSI) FOR FOOTINGS, GRADE BEAMS, ROOF D D
BEAMS , COLUMNS, SLAB ON GRADE, & OTHERS, FOR SCHOOL TYPE D.
1. GOVERNING CODES: (fc') 17 Mpa (2500 PSI) FOR FOOTINGS, GRADE BEAMS, ROOF BEAMS COLUMNS,
SLAB ON GRADE, & OTHERS. FOR SCHOOL TYPE A, B, C, SCI-LAB, TOILET.
ACI 318-89, BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE UNIFORM BUILDING CODE, 1988
NATIONAL STRUCTURAL CODE OF THE PHILIPPINES, 1992 EDITION 2. REINFORCING STEEL YIELD STRENGTH (fy): 206.84 Mpa (33000 PSI)
3. STRUCTURAL STEEL YIELD STRENGTH (fy): 248 Mpa (36000 PSI)
4. MASONRY COMPRESSIVE ULTIMATE STRENGTH (fm): 3.10 Mpa (450 PSI)
2. GOVERNING STANDARDS:
5. MASONRY CONCRETE GROUP COMPRESSIVE STRENGTH (fc'): 13.8 MPa (2000 PSI)
BAR SIZE D ldh ( MM )
6. MASONRY REINFORCING STEEL YIELD STRENGTH (fy): 275 MPa (40000 PSI) ( MM ) ( MM ) ( MM ) ( MM ) BAR SIZE
ASTM A36 BUILDING CODE REQUIREMENTS FOR STRUCTURAL STEEL DIAGONAL SHEAR BARS ( MM )
(TYP) =60MM 60 65 120 TOP BARS OTHERS
ASTM A611 STEEL, SHEET, CARBON, COLD-ROLLED,STRUCTURAL QUALITY

ASTM A615 DEFORMED AND PLAIN STEEL BARS FOR CONCRETE REINFORCEMENT
ll. CONSTRUCTION NOTES: 72
96
65
65
145
195
300
300
300
300
AT BEAM (LOCATION WITHIN MIDDLE THIRD SPAN ) 120 80 240 400 305
ASTM C33 CONCRETE AGGREGATES
GENERAL 150 100 300 495 380
ASTM C39 METHOD OF TEST FOR COMPRESSIVE STRENGTH OF MOULDED CONCRETE CYLINDERS 955 735
ASTM C94 READY-MIXED CONCRETE
ASTM C150 PORTLAND CEMENT
1. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE ARCHITECTURAL, ELECTRICAL, SANITARY, MIN. STRAIGHT BAR
SG 671 SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS BY AMERICAN IRON AND
PLUMBING & SPECIFICATIONS.
2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE, WHICH SHALL INCLUDE THE LOCATION TYPICAL CONSTRUCTION JOINT DETAIL
STEEL INSTITUTE AND DIMENSIONS OF OPENINGS, GROOVES, REGLETS, PIPE SLEEVES, CONDUITS, EMBEDDED OR ATTACHED ITEMS TO
CONCRETE, ETC.
MINIMUM REQUIREMENT FOR DEVELOPMENT LENGTH
DESIGN LOADS 3. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT NEW AND EXISTING CONSTRUCTION. THIS
SHALL INCLUDE BUT NOT BE LIMITED TO BRACING AND SHORING FOR LOADS IMPOSED DURING CONSTRUCTION.

1. DEAD LOADS 4. ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS, SECTIONS, AND DETAILS.

5. GENERAL NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED.
CONC COL, BEAMS (SELF WEIGHT) 24 KN/CU.M
CEILING, FIXTURES, ETC. 0.20 KPa 6. ALL DIMENSIONS ARE IN METRIC SYSTEM UNLESS OTHERWISE NOTED.
CHB WALLS, 6" THK 2.73 KPa
CHB WALLS, 4" THK 1.92 KPa 7. ALL BAR DIAMETERS AND SPACINGS ARE IN MM UNLESS OTHERWISE NOTED. CRITICAL SECTION
CRITICAL SECTION
METAL ROOFING, GA. 26 0.10 KPa
STEEL PURLINS 0.10 KPa
STEEL TRUSSES 0.20 KPa
SOIL (SELF-WEIGHT) 16 KN/CU.M CONCRETE 100MM THK. CHB WALL RC STIFFENER
WATER (SELF-WEIGHT) 9.81 KN/CU.M 400
STEEL (SELF-WEIGHT) 77 KN/CU.M TO MATCH HOR. BAR
LAP
10MM HOR. BARS
TOPPING/FINISH 0.80 KPa 1. MINIMUM CONCRETE COVER TO ALL REINFORCING BARS SHALL BE AS FOLLOWS: EVERY 3 LAYERS

2. LIVE LOADS A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 75MM
B. FORMED SURFACES EXPOSED TO EARTH OR WEATHER AT 600MM O.C
ROOF LIVE LOAD (30 DEGREES SLOPE)
OTHER BARS 50 MM

LAP
TRIBUTARY LOADED AREA (SQ.M.) ldh ( MM )
0 TO 20 0.80 KPa C. FORMED SURFACES NOT EXPOSED DIRECTLY TO EARTH OR WEATHER BAR SIZE
21 TO 60 0.70 KPa SLABS AND WALLS 20 MM ( MM ) AT 600MM O.C
TOP BARS OTHERS
OVER 60 0.60 KPa BEAMS AND COLUMNS 40 MM
165 150
FLOOR LIVE LOAD TO MATCH HOR. BAR
2. REINFORCING BARS SHALL BE FREE OF RUST, GREASE, OR OTHER MATERIALS 205 155
CLASSROOM 2.00 KPa LIKELY TO IMPAIR BOND. 270 205 10MM HOR. BARS
CORRIDOR, ETC. 4.80 KPa
335 255 EVERY 3 LAYERS
3. ALL REINFORCING BARS SHALL BE ACCURATELY AND SECURELY PLACED RC STIFFENER
620 475
BEFORE POURING CONCRETE OR APPLYING MORTAR OR GROUT.
3. WIND LOADS 4. BAR SPLICES SHALL BE SECURELY WIRED TOGETHER, SPLICES IN REINFORCED MIN. HOOKED BAR
CONCRETE BEAMS, COLUMNS, AND WALLS SHALL BE AS SHOWN IN THE
DETAILS. FOR NON-STRUCTURAL WALLS, MASONRY WALLS, AND SLBSM AT CORNER
P=Ce+l+Qs+Cq (BASIC WIND PRESSURE, KPa) SPLICES SHALL LAP A MINIMUM OF 40 BAR DIA AND SHALL BE STAGGERED
ZONE 1 V=200 KPH Qs=2 KPa WHEREVER POSSIBLE.
EXPOSURE C, WHERE Ca AVG.=1.17
l=1.0, STANDARD OCCUPANCY STRUCTURES 5. SPLICES REQUIRED IN THE REINFORCEMENT OF BEAMS/GIRDERS FRAMING
NORMAL FORCE METHOD IS USED TO COMPUTE WIND PRESSURE EFFECTS INTO COLUMNS SHALL NOT BE LOCATED WITHIN THE COLUMN NOR WITHIN A
P=1.17*2.0*1.00*Cq=2.34*Cq (KPa) DISTANCE OF TWICE THE BEAM/GIRDER DEPTH FROM THE FACE OF THE AT INTERSECTION
THE DIFFERENT Cq VALUES ARE AS FOLLOWS: COLUMN. AT LEAST TWO CLOSED STIRRUP TIES SHALL BE PROVIDED AT ALL
SPLICES.
TYPICAL CHB CONNECTION DETAIL
3.1. PRIMARY FRAMES 6. LAP SPLICES SHALL BE MADE WITHIN THE CENTER HALF OF COLUMN HEIGHT,
AND THE SPLICE LENGTH SHALL NOT BE LESS THAN WHAT IS INDICATED IN
WALLS: THE TABULATED VALUES OF SPLICE LENGTH.
WINDWARD WALL 0.80 INWARD
LEEWARD WALL 0.50 OUTWARD
ROOFS: STRUCTURAL STEEL:
LEEWARD ROOF 0.70 INWARD L1
WINDWARD ROOF 0.90 OUTWARD 1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM WITH THE 9TH EDITION
OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL
3.2. ELEMENTS AND COMPONENTS UNLESS OTHERWISE NOTED OR SHOWN.
WALL ELEMENTS 1.20 INWARD
2. CONTRACTOR SHALL FURNISH ALL PLATES, CLIP ANGLES, CONNECTORS, ETC.
ROOF ELEMENTS 1.30 OUTWARD
REQUIRED FOR THE COMPLETION OF THE STRUCTURE EVEN IF EVERY SUCH
ITEM IS NOT SHOWN ON THE CONTRACT DRAWINGS. L2 NOTE : UNLESS OTHERWISE NOTED
l1 = ln/5
4. SEISMIC LOAD 3. WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY CODE (AWS D 1.1) l2 = ln/4
UNLESS INDICATED OTHERWISE, WELDING ELECTRODES SHALL BE E60 XX. L1 AND L2 SHOULD NOT BE
V=(Z*1*C/Rw)*W (BASE SHEAR, Kn) ZONE 4 LESS THAN ld
Z=0.40, ZONE COEFFICIENT 4. ALL BOLTS AND THREADED FASTENERS SHALL BE ASTM A307 UNLESS
OTHERWISE NOTED. ln
1=1.00, STANDARD OCCUPANCY STRUCTURE
Rw=5.0, OMRSF, CONCRETE
C=1.25*S/(T^2/3) < 2.75
S=1.5, SITE COEFFICIENT
MASONRY: TYPICAL ROOF BEAM
T=Ct*Hn^3/4 SEC.
Hn=7.5M. 1. ALL CONCRETE HOLLOW BLOCKS MASONRY WALLS SHALL BE LAID IN
NOTES : NOTES :
Ct=0.075 FOR RCMRSF RUNNING BOND (INTERLOCKING COURSE) WITH FULL MORTAR BEDDING,
T=0.075*7.5^3/4=0.339 SEC. STACK BOND SHALL BE USED ONLY WHEN SPECIFIED.
C=1.25*1.5/(0.339^2/3)=3.86 > 2.75
2. RECOMMENDED COMPRESSIVE STRENGTH OF CONCRETE HOLLOW BLOCKS
USE C=2.75
SHALL BE 450 PSI (3.10 Mpa) OF ITS NET AREA.
V=(0.40*1.00*2.75/5)*W=0.22*W, Kn 1. TERMINATE ALL REQUIRED TOP &
3. ALL CELLS SHALL BE SOLIDLY FILLED WITH CONCRETE GROUT. 1. SPLICES ARE PERMITTED ONLY WITHIN THE CENTER
5. SOIL PROPERTIES BOTTOM BARS AT THE FAR FACE HALF OF COLUMN HEIGHT (H).
OF THE COLUMN CORE.
CASE A: Qa = 8 T/SQ.M. (78.50 KPa)
CASE A: Qa = 5 T/SQ.M. (49.10 KPa) VERTICAL SPACING: 600MM 2. STAGGER BAR SPLICES BY 600MM OR MORE.
HORIZONTAL SPACING: AT EVERY 3 LAYERS 2. MINIMUM DEVELOPMENT LENGTH
UNIT WEIGHT=16 KN/CU.M (ASSUMED)
L1 = ld FOR TOP BARS
3. PROVIDE TIES AT 100MM O.C. OVER THE FULL LAP
L2 = ld FOR OTHERS
SPLICE LENGTH.

3. LAP SPLICE WITHIN THE JOINT


IS NOT ALLOWED. 4. SPECIAL TIES AT THE BEAM/COLUMN JOINT TO CONFIGURE
TO THE SAME CONFIGURATION OF TIES AS INDICATED
4. AT LAP SPLICES, SPACING OF STIRRUPS IN THE SCHEDULE OF COLUMNS.
TYPICAL LINTEL BEAM DETAIL SHALL BE 100MM MINIMUM. 5. ALL DIMENSIONS SHOULD BE IN MILLIMETER.

STRUCTURAL DESIGN
CRITERIA
TYP. CONST. JOINT DET.
A-10
D1 D2 D3 D4 D5 W1 W2 W3 W4 W5
1 UNIT 2 UNITS 2 UNITS 1 UNIT 4 UNITS 1 set 11 sets 5 sets 1 set 2 sets
DOUBLE SWING TYPE GLASS DOOR EXTERIOR WOODEN DOOR # 12" THICK DOUBLE SLIDING GLASS DOOR # 3/4" THICK FRAMELESS SINGLE SWING #0.60m x 2.10m Flushed Type PVC Door # 1/4" Thick 0.5m x 0.5m TINTED GLASS # 1/4" Thick 0.5m x 0.5m TINTED GLASS # 1/4" Thick 0.5m x 0.5m TINTED GLASS # 1/4" Thick 0.5m x 0.5m TINTED GLASS # 1/4" Thick 0.5m x 0.5m TINTED GLASS
W/ FRAME & COMPLETE ACCESSORIES LOCKSET: KWIKSET DOOR KNOB OR W/ FRAME AND ACCESSORIES TYPE GLASS DOOR W/ COMPLETE AWNING TYPE W/ FRAME AND COMPLETE AWNING TYPE W/ FRAME AND COMPLETE AWNING TYPE W/ FRAME AND COMPLETE AWNING TYPE W/ FRAME AND COMPLETE AWNING TYPE W/ FRAME AND COMPLETE
EQUIVALENT ACCESSORES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES

DOORS AND WINDOWS SCHEDULE

STEEL WINDOW
FRAME
STEEL WINDOW
FRAME
PROVIDE SEALANT
CONCRETE JAMB
500X100MM/150MM
WELDED TO
WOOD JAMB PROVIDE SEALANT
10 MM REBAR
DOOR FRAME

100/150MM THK CHB WALL


W/ 20 MM THK CEMENT PLASTER

WALL DETAIL
DETAIL SECTION SILL DETAIL

CEILING DETAIL

FIXED HINGE
CO. #26 ORDINARY
CORRUGATION
GUSSET PLATE PRE-PAINTED LONG
SPAN ROOFING
500X100MM/150MM
ANCHOR BOLT WOOD JAMB
BASE PLATE
CO. #26 ORDINARY
CORRUGATION
GUSSET PLATE
PRE-PAINTED LONG
SPAN ROOFING 45 MM THICK
45 MM FLUSH DOOR 100 MM LONG CW NAIL
PURLINS (REFER TO ( STAGGERED ) FLUSH DOOR
TOP CHORD 50X150MM DOOR JAMB
STRUCTURAL DETAILS)
BOTTOM CHORD OUTSIDE
20X35MM CEMENT 6 MM THK MARINE PLYWOOD
FIBER BOARD 3 MM THK 50X25MM (ON BOTH SIDES)
RB1
6 MM THK FICEM
CORR. ALUM.
ANGLE NOSING
OUTSIDE
BOARD (PAINTED)
ON 50X50MM JOISTS @ LINTEL BEAM
INSIDE
600 MM OC B.W CORRIDOR LINE FR. 50X50MM DOOR FRAME

PROVIDE SEALANT 50
FROM 25X25MM COAT WITH
COVE ROOF VENT PAINTED HOT ASPHALT
MOULDING 50X100MM/150MM INSIDE
CONCRETE COLUMN DOOR JAMB
QUARTER C MOULDING 100/150MM THK CHB
6 MM THK GROOVE
6 MM THK FICEM (ALL AROUND)
BOARD (PAINTED) PROVIDE SEALANT
ON 50X50MM JOISTS @ OUTSIDE 45 MM FLUSH DOOR
600 MM OC B.W GROUT FILL

TRUSS-BEAM CONNECTION DETAILS HEAD DETAIL DOOR SILL DETAIL COAT W/ HOT ASPHALT

DOORS & WINDOWS DETAIL


WALLING DETAIL
CEILING DETAIL
SILL DETAIL
TRUSS BEAM CONNECTION
DETAIL
A-11
HEAD DETAIL
DOORSILL DETAIL
ELECTRICAL PLAN E-1
1 POINT HOOK
LEGEND
ON CONCRETE POLE (N.I.C)
220 V AC

FROM METER CENTER / ELECTRICAL


CONCRETE POST

PANEL
KILOWATT BOARD (L-1)
HOUR METER M

1,500 MAX.
2 C # 3.5 mm THW CABLE
IN 25 mm
2
2 C # 8.0 mm THW SE
2 - 8.0mm THWN

4" X 4"
S#
JUNCTION BOX
NGL (W.P)

M
FOR LINE TO GROUND
ELECTRICAL CONNECTION
WHERE APPLICABLE MCB
15/20 AMPS
GROUND 2-POLE

LIGHTING OUTLETS CONVENIENCE OUTLETS

C SINGLE LINE DIAGRAM B RISER DIAGRAM M


E-1 SCALE N T S E-1 SCALE N T S

COMPUTATION OF LOADS NOTES AND SPECIFICATIONS

SINGLE LINE DIAGRAM


RISER DIAGRAM
COMPUTATION OF LOADS
NOTES SPECIFICATION
E-2
SCHEDULE OF LOADS
GENERAL
PLUMBING SYMBOLS PLUMBING NOTES
ALL PLUMBING WORKS HEREIN SHALL BE
PLUMBING FIXTURES EXECUTED ACCORDING TO THE REQUIREMENTS
OF THE PHILIPPINE NATIONAL PLUMBING CODE
AND THE RULES AND REGULATIONS OF THE
WC WATER CLOSET EXISTING LOCAL CODES AND ORDINANCES.
NOTHING CONTAINED ON THE DRAWINGS SHALL
BE COSTRUED AS TO CONFLICT WITH THE
BT BATH TUB NATIONAL AND LOCAL ORDINANCES OR LAWS
GOVERNING THE IMPLEMENTATION OF THE
PLUMBING WORKS.
LAV LAVATORY
600x600x100 mm REFER TO ALL ELECTRICAL, STRUCTURAL AND
CONCRETE COVER
ARCHITECTURAL PLANS AND SPECIFICATIONS
4"THK. CHB
KS KITCHEN SINK (SINGLE BOWL) AND INVESTIGATE ALL POSSIBLE INTER-
FERENCES AND CONDITIONS AFFECTING THE
PLUMBING WORKS.
SS SLOPE SINK
IT IS NOT INTENDED THAT THE DRAWING SHALL
SHOW EVERY PIPEFITTING, VALUE, APPLIANCES
FD FLOOR DRAIN OTHER. FURNISH AND INSTALL IF NECESSARY
ALL SUCH ITEM, WHETHER SPECIFICALLY
MENTIONED OR NOT OR INDICATED ON
SD SHOWER DRAIN DRAWINGS TO COMPLETE THE SYSTEM IN
ACCORDANCE WITH THE BEST PRACTICE OF
THE TRADE AND TO THE SATISFACTION OF THE
ARCHITECT.

WHERE A BRANCH SERVING MORE THAN ONE


SEWER & SANITARY LINE FIXTURE INCREASE THE SIZE OF THE BRANCH
INCREASE PROPORTIONATELY.

ST SEPTIC TANK PROVIDE MATERIALS THAT ARE NEW AND THAT


CONFORM WITH THE STANDARDS OF UNDER-
WRITERS LABORATORIES INCORPORATED.
CB CATCH BASIN
FOR OTHER MISCELLANEOUS REQUIRED
MATERIALS NOT SPECIFICALLY MENTIONED,
GT GREASE TRAP PROVIDE THE BEST THE ESPECTIVE.

SUBMIT SAMPLES OF MATERIAL FOR APPROVAL


SS SOIL STACK AS REQUIRED BY THE ARCHITECT.

COMFORM ALL APPLICABLE PIPES AND MA-


WS WASTE STACK TERIALS FOR VARIOUS SERVICES TO THE
STANDARDS.

VS VENT STACK INSTALL ALL PLUMBING FIXTURES FREE AND


OPEN IN MANNER FOR ACCESS FOR CLEANING.
FURNISH BRACKETS, CLEATS AND ANCHOR
VTR VENT-THRU-ROOF REQUIRED TO SUPPORT THE FIXTURES RIGIDLY
IN PLACE.
VR VENT RISER KEEP AWAY AT A SUFFICIENT DISTANCE BUT
NOT LESS THAN 12" ( 12.7 MM, ALL SERVICE
400x600x50 mm
CO CLEAN OUT PIPES, VALVES AND FITTINGS FROM SURFACES
CONCRETE BUFFER
AND LOCATIONS WHICH MAY REQUIRE FINISH
COATS AND COVERING.
DS DOWNSPOUT
EXTEND THE PIPING TO ALL FIXTURES,OUTLETS
AND EQUIPMENTS FROM THE REQUIRED GATE
4"THK. CHB
RC RAIN CONDUCTOR VALVES INSTALLED IN EACH BRANCH NEAR
RISERS.

PROVIDE THE ENTIRE SYSTEM WITH VALVES


NO. 8 MESH BARS MATTING
SO LOCATED THAT THE SYSTEM OR PORTION
OF IT CAN BE OPERATED, REPLACED AND
REPAIRED AS WELL AS COMPLETE CONTROL
OF THE WATER SUPPLY TO EACH GROUP OF
FIXTURES. WHEN REQUIRED, PROVIDE ALSO
WATER DISTRIBUTION LINE PRESSURE REDUCING VALVES.

INSTALL ALL PIPING IN CONFORMITY WITH


S SHOWER PROVISIONS OF THE LATES EDITION OF THE
PHILIPPINE NATIONAL PLUMBING CODE AND
APPLICABLE REQUIREMENTS OF EXISTING
F FAUCET LOCAL CODES.

EXCAVATE TO REQUIRED DEPTHS AND


FHB FAUCET HOSE BIBB GRADES ALL EXCAVATIONS REQUIRED FOR
THE INSTALLATIONS OF THE PLUMBING AND
DRAINAGE SYSTEM.
WH WATER HEATER
ALL PLUMBING INSTALLATIONS HEREIN
GV GATE VALVE SHALL BE UNDER THE DIRECT
SUPERVISION OF THE UNDERSIGNED
CV CHECK VALVE OR OF HIS AUTHORIZED
REPRESENTATIVE.
MGV MAIN GATE VALVE

WM WATER METER

R RISER
PROCESS LINE
CWL COLD WATER LINE
PROCESS LINE
CWL HOT WATER LINE
SWR SEWER LINE

SDL DRAINAGE LINE

ISOMETRIC VIEW
SEPTIC TANK
CATCH BASIN
GREASE TRAP DETAIL
P-1