SOP(STRUCTURAL) PMI-123(ARCHITECTURAL)
NOTE:
1. ARCHITECTURAL & MEPF PLANS
2. NO AVAILABLE CSD REVIT MODEL
YET BASED ON THE LATEST ISSUED
A B C
MEPF BLOCK-OUT MGW-TRANSMIT-006038 -WCC-AED-AR-DR-000-03-10006_C05 ARE BASED ONLY IN FCD, BUT FOR FCD.
-WCC-M001-ST-SD-000-03-20007_2 PMI-109(MEPF) THE SECTION ARE BASED ONLY IN 3. ELEVATION OF SLEEVES AND
MEPF PIPE SLEEVE -WCC-M001-ST-SD-000-03-20008_2 -WCC-WSP-E4-DR-000-03-44363_C04 THE GIVEN REVIT MODEL BY THE BLOCK-OUT ARE PROPOSED AND
SYΔ-TRANSMIT-000016 -WCC-WSP-F1-DR-000-03-21363_C04 CONSULTANT. SUBJECT FOR APPROVAL.
B.O.S. BOTTOM OF SLEEVE -WCC-M001-ST-SD-000-05-21003_1 -WCC-WSP-F2-DR-000-03-22363_C04 SY2 NOTES:
-WCC-M001-ST-SD-000-05-21004_1
B.O.W.O. BOTTOM OF WALL *FOLLOW TYPICAL WALL OPENING 1 31/05/2022 ISSUED FOR APPROVAL
OPENING DETAIL FOR
Rev. Date (D/M/Y) Description
150X150mm BLOCKOUT FOR BLOCKOUT NOT GREATER THAN 1m.
100MM DIA. G.I. PIPE SLEEVE 80MM DIA. BFS-SPR *VERIFY MEPF AND ARCHITECTURAL
BF FOR Ø80mm BFS-SPR
@+4750mm B.O.S. 50mm DIA. G.I. PIPE SLEEVE
@ +4675mm B.O.W.O. REQUIREMENTS
300X300mm BLOCKOUT FOR
FOR 40MM DIA. BFS-SPR 150MM BFS RISER AND FDAS
#20 N. DOMINGO STREET, BRGY. VALENCIA, QUEZON CITY
100MM DIA. G.I. PIPE SLEEVE @ +4726mm B.O.S. CONDUIT @ +4600mm B.O.W.O.
TEL : (+632) 655-9164
75
BSB-38 (1200x1500mm)
5 B.O.B.+31.800 3 TUV Rheinland
Precisely Right.
R TUV Rheinland Philippines, Inc.
G/F La Fuerza Bldg. 1, Don Chino Roces Ave.
300
1231 Makati City, Philippines
MEP Engineer
6 4
2
150
300
150 1
1902
1851
1776
BLOCKOUTS NOT ALLOWED
ON S.W. Project Manager
SUNTRUST HOME
DEVELOPERS, INC.
26th Floor, Alliance Global Tower, 36th St Cor, 11th Av.,
Uptown Bonifacio, Fort Bonifacio, Taguig City 1634
4775
4750
OWNER/DEVELOPER
4726
4675
4600
Project Title
Ryan Douglas E. Rios - C+A 150X150mm BLOCKOUT FOR Contractor shall verify all MEP openings with
100MM DIA. G.I. PIPE SLEEVE 06.30.2022 80MM DIA. BFS-SPR CSD coordination prior to construction
BF FOR Ø80mm BFS-SPR
@+4750mm B.O.S. 50mm DIA. G.I. PIPE SLEEVE
@ +4675mm B.O.W.O.
100MM DIA. G.I. PIPE SLEEVE @ +4726mm B.O.S. CONDUIT @ +4600mm B.O.W.O.
TEL : (+632) 655-9164
75
BSB-38 (1200x1500mm)
5 B.O.B.+31.800 3 TUV Rheinland
Precisely Right.
R TUV Rheinland Philippines, Inc.
G/F La Fuerza Bldg. 1, Don Chino Roces Ave.
300
1231 Makati City, Philippines
MEP Engineer
6 4
2
150
300
150 1
1902
1851
1776
Project Manager
SUNTRUST HOME
DEVELOPERS, INC.
26th Floor, Alliance Global Tower, 36th St Cor, 11th Av.,
Uptown Bonifacio, Fort Bonifacio, Taguig City 1634
4775
4750
OWNER/DEVELOPER
4726
4675
4600
Project Title
75
BSB-38 (1200x1500mm)
5 B.O.B.+31.800 3 TUV Rheinland
Precisely Right.
R TUV Rheinland Philippines, Inc.
G/F La Fuerza Bldg. 1, Don Chino Roces Ave.
300
1231 Makati City, Philippines
MEP Engineer
6 4
2
150
300
150 1
1902
1851
1776
Please move down
blockout #1 & 3 to below
Project Manager
landing high level.
SUNTRUST HOME
Please confirm if opening for conduit can be cored DEVELOPERS, INC.
26th Floor, Alliance Global Tower, 36th St Cor, 11th Av.,
on site, otherwise please provide pipe sleeve for Uptown Bonifacio, Fort Bonifacio, Taguig City 1634
minimum DN50 FDAS conduit as the exact conduit
4775
4750
OWNER/DEVELOPER
4726
4675
4600
size to be confirmed by the FS NSC to perform the Project Title
calculation of AFA system. (Typical for all FDAS
conduit)
Westside City Phase 1 - Site B
Bagong Nayong Pilipino Entertainment
City, Paranaque City
Status
ISSUED FOR APPROVAL
Discipline
MULTI-DISCIPLINARY