TYPICAL CROSS SECTION

SCALE 1:40

REINFORCEMENT
TRANSVERSE REINFORCEMENT DETAIL
SCALE 1:40
1. REINFORCING BARS, INCLUDING HELICAL REINFORCEMENT, BUT NOT FABRIC
REINFORCEMENT AND DOWELS ARE SCALED UP ON THE DRAWINGS IN THE FOLLOWING
MANNER:
NO OFF: BAR TYPE: BAR DIAMETER - BAR MARK - PITCH: POSITION AND/OR COMMENT
E.G. 7 H20 09-125-B1
BAR TYPE DESIGNATION IS AS FOLLOWS: GENERAL NOTES
B = GRADE B500B OR B500C RIBBED BARS COMPLYING WITH BS 4449
S = GRADE 1.4301 STAINLESS STEEL REINFORCEMENT COMPLYING WITH
BS EN 10088-1
CONCRETE CLASS 50 (MPa)
POSITION/COMMENT IS DESIGNATED AS FOLLOWS:
CONCRETE COVER: 50mm
T = TOP FACE, B = BOTTOM FACE, NF = NEAR FACE, FF = FAR FACE
CONCRETE COVER IN CONTACT WITH CONCRETE: 10mm
ABR = ALTERNATE BARS REVERSED
STG = ALTERNATE BAR STAGGERED BY THE AMOUNT SHOWN
ALT = ALTERNATE BARS
COUPLER = BAR END INDICATED TO BE SWAGED FOR SCREW TYPE COUPLER
CALLOUT SHALL BE READ AS SHOWN BELOW REFERENCE DRAWINGS
WHERE TWO BAR MARKS ARE SCALED UP TOGETHER AND IDENTIFIED AS "AB", THE REINFORCEMENT
SPACING STATED IS THE SPACING OF ALL BARS NOT OF EACH BAR MARK. GENERAL NOTES
2. WHERE REINFORCEMENT COUPLERS ARE USED, THEY SHALL BE POSITIONED STEEL GRADE D630-ST-DJV-DRA-534106
SO AS TO ACHIEVE THE SAME NOMINAL COVER AS THAT SPECIFIED FOR THE D630-ST-DJV-DRA-534107
REINFORCEMENT BARS WHICH THEY COUPLE. GEOMETRY PRESTRESSING
3. STEEL SPACERS OF SIMILAR DIAMETER TO BARS BUT NOT LESS THAN 25 DIAMETER
SHALL BE PROVIDED BETWEEN ADJACENT LAYERS OF PARALLEL REINFORCEMENT AND LAYER
SPACED AT NO MORE THAN 6 0 TIMES THE SMALLER BAR DIAMETER.
THESE SPACER BARS ARE NOT INCLUDED ON THE BAR SCHEDULES.
4. SPACERS, TIES AND STOOLS SHALL BE SUPPLIED BY
THE CONTRACTOR AS NECESSARY TO SECURE THE REINFORCEMENT
* WHEN ONLYONE IDENTIFICATION: PRECAST SCHEME
XXX BAR MARK
AGAINST DISPLACEMENT .
5. PVC DUCTS ARE TO BE INSTALLED PRIOR TO CAST THE HANDRAIL.
SEE DRAWINGS D630-ST-DJV-DRA-534901 & D630-ST-DJV-DRA-534903

SUBCONTRACTOR: PROJECT: SCALE


REVISIONS
X NO. DATE DESCRIPTION BACK SPAN
A 20/03/2020 ISSUED FOR CONSTRUCTION SUPERSTRUCTURE
B 10/04/2020 ISSUED FOR CONSTRUCTION DECK REINFORCEMENT
T1-S5-b & T2-S5-b
BY: DJV C

DATE: 200416 D
B
SIGNATURE E D630-ST-CFC-SHD-8176 30
T1 & T2 S5b T1 & T2 S5b T1 & T2 S5b T1 & T2 S5b T1 & T2 S5b
7150 7150 7150 7150 7150

UPPER SLAB UPPER SLAB UPPER SLAB UPPER SLAB UPPER SLAB (LINKS)
TRANSVERSAL UPPER LONGITUDINAL UPPER TRANSVERSAL BOTTOM LONGITUDINAL BOTTOM SCALE 1:100
SCALE 1:100 SCALE 1:100 SCALE 1:100 SCALE 1:100

T1 & T2 S5b
REINFORCEMENT
7150
1. REINFORCING BARS, INCLUDING HELICAL REINFORCEMENT, BUT NOT FABRIC
REINFORCEMENT AND DOWELS ARE SCALED UP ON THE DRAWINGS IN THE FOLLOWING
MANNER:
NO OFF: BAR TYPE: BAR DIAMETER - BAR MARK - PITCH: POSITION AND/OR COMMENT
E.G. 7 H20 09-125-B1
BAR TYPE DESIGNATION IS AS FOLLOWS: GENERAL NOTES
B = GRADE B500B OR B500C RIBBED BARS COMPLYING WITH BS 4449
S = GRADE 1.4301 STAINLESS STEEL REINFORCEMENT COMPLYING WITH
BS EN 10088-1
CONCRETE CLASS 50 (MPa)
POSITION/COMMENT IS DESIGNATED AS FOLLOWS:
CONCRETE COVER: 50mm
T = TOP FACE, B = BOTTOM FACE, NF = NEAR FACE, FF = FAR FACE
CONCRETE COVER IN CONTACT WITH CONCRETE: 10mm
ABR = ALTERNATE BARS REVERSED
STG = ALTERNATE BAR STAGGERED BY THE AMOUNT SHOWN
ALT = ALTERNATE BARS
COUPLER = BAR END INDICATED TO BE SWAGED FOR SCREW TYPE COUPLER
CALLOUT SHALL BE READ AS SHOWN BELOW REFERENCE DRAWINGS
WHERE TWO BAR MARKS ARE SCALED UP TOGETHER AND IDENTIFIED AS "AB", THE REINFORCEMENT
SPACING STATED IS THE SPACING OF ALL BARS NOT OF EACH BAR MARK. GENERAL NOTES
2. WHERE REINFORCEMENT COUPLERS ARE USED, THEY SHALL BE POSITIONED STEEL GRADE D630-ST-DJV-DRA-534106
SO AS TO ACHIEVE THE SAME NOMINAL COVER AS THAT SPECIFIED FOR THE D630-ST-DJV-DRA-534107
REINFORCEMENT BARS WHICH THEY COUPLE. GEOMETRY PRESTRESSING
3. STEEL SPACERS OF SIMILAR DIAMETER TO BARS BUT NOT LESS THAN 25 DIAMETER
SHALL BE PROVIDED BETWEEN ADJACENT LAYERS OF PARALLEL REINFORCEMENT AND LAYER
SPACED AT NO MORE THAN 6 0 TIMES THE SMALLER BAR DIAMETER. SCHEME
THESE SPACER BARS ARE NOT INCLUDED ON THE BAR SCHEDULES.
4. SPACERS, TIES AND STOOLS SHALL BE SUPPLIED BY
* WHEN ONLYONE IDENTIFICATION: PRECAST
THE CONTRACTOR AS NECESSARY TO SECURE THE REINFORCEMENT
AGAINST DISPLACEMENT .
XXX BAR MARK UPPER SLAB
5. PVC DUCTS ARE TO BE INSTALLED PRIOR TO CAST THE HANDRAIL. TRANSVERSAL UPPER
SEE DRAWINGS D630-ST-DJV-DRA-534901 & D630-ST-DJV-DRA-534903 DETAIL
SCALE 1:75

SUBCONTRACTOR: PROJECT: SCALE


REVISIONS
X NO. DATE DESCRIPTION BACK SPAN
A 20/03/2020 ISSUED FOR CONSTRUCTION SUPERSTRUCTURE
B 10/04/2020 ISSUED FOR CONSTRUCTION DECK REINFORCEMENT
T1-S5-b & T2-S5-b
BY:
DJV C

DATE: 200416 D
B
SIGNATURE E D630-ST-CFC-SHD-8176 31
Bending Schedule Drawing No. Page No. Revision

31 1 of 5 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
US-K 24 B10 1 816 816 425 22 130 175 60 (120)

29 B8 1 476 476 325 13 150 65 (150)

47a B10 1 68 68 450 22 130 185 60 (120)

47b B10 1 68 68 450 22 125 210 55 (120)

47c B10 1 68 68 475 22 120 235 50 (115)

47d B10 1 68 68 500 22 115 260 50 (115)

48a B10 1 17 17 950 22 130 680 60 (120)

48b B10 1 17 17 900 22 130 650 60 (120)

48c B10 1 17 17 875 22 125 625 60 (120)

48d B10 1 17 17 850 22 125 595 55 (120)

48e B10 1 17 17 825 22 125 565 55 (120)

48f B10 1 17 17 775 22 125 535 55 (120)

48g B10 1 17 17 750 22 120 505 55 (115)

48h B10 1 17 17 725 22 120 480 55 (115)

48i B10 1 17 17 700 22 120 450 50 (115)

48j B10 1 17 17 650 22 120 420 50 (115)

48k B10 1 17 17 625 22 115 390 50 (115)

48l B10 1 17 17 600 22 115 360 50 (115)

48m B10 1 17 17 575 22 115 335 50 (115)

104a B10 1 17 17 950 22 130 680 60 (120)

104b B10 1 17 17 900 22 130 650 60 (120)

104c B10 1 17 17 875 22 125 625 60 (120)

104d B10 1 17 17 850 22 125 595 55 (120)

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

31 2 of 5 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
US-K 104e B10 1 17 17 825 22 125 565 55 (120)

104f B10 1 17 17 775 22 125 535 55 (120)

104g B10 1 17 17 750 22 120 505 55 (115)

104h B10 1 17 17 725 22 120 480 55 (115)

104i B10 1 17 17 700 22 120 450 50 (115)

104j B10 1 17 17 650 22 120 420 50 (115)

104k B10 1 17 17 625 22 115 390 50 (115)

104l B10 1 17 17 600 22 115 360 50 (115)

104m B10 1 17 17 575 22 115 335 50 (115)

105a B10 1 17 17 950 22 130 680 60 (120)

105b B10 1 17 17 900 22 130 650 60 (120)

105c B10 1 17 17 875 22 125 625 60 (120)

105d B10 1 17 17 850 22 125 595 55 (120)

105e B10 1 17 17 825 22 125 565 55 (120)

105f B10 1 17 17 775 22 125 535 55 (120)

105g B10 1 17 17 750 22 120 505 55 (115)

105h B10 1 17 17 725 22 120 480 55 (115)

105i B10 1 17 17 700 22 120 450 50 (115)

105j B10 1 17 17 650 22 120 420 50 (115)

105k B10 1 17 17 625 22 115 390 50 (115)

105l B10 1 17 17 600 22 115 360 50 (115)

105m B10 1 17 17 575 22 115 335 50 (115)

106a B10 1 17 17 950 22 130 680 60 (120)

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

31 3 of 5 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
US-K 106b B10 1 17 17 900 22 130 650 60 (120)

106c B10 1 17 17 875 22 125 625 60 (120)

106d B10 1 17 17 850 22 125 595 55 (120)

106e B10 1 17 17 825 22 125 565 55 (120)

106f B10 1 17 17 775 22 125 535 55 (120)

106g B10 1 17 17 750 22 120 505 55 (115)

106h B10 1 17 17 725 22 120 480 55 (115)

106i B10 1 17 17 700 22 120 450 50 (115)

106j B10 1 17 17 650 22 120 420 50 (115)

106k B10 1 17 17 625 22 115 390 50 (115)

106l B10 1 17 17 600 22 115 360 50 (115)

106m B10 1 17 17 575 22 115 335 50 (115)

US-LB 19 B16 1 52 52 8200 00

20 B25 1 8 8 3375 00

21 B20 1 31 31 8350 00

95 B16 1 8 8 8200 00

102 B20 1 4 4 3125 00

103 B20 1 4 4 4325 00

20A B25 1 8 8 4700 00

US-LU 18 B25 1 128 128 8700 00

99 B25 1 3 3 4900 00

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

31 4 of 5 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
US-LU 100 B25 1 3 3 2900 00

US-TB 02 B16 1 72 72 5000 00

6 B32 1 36 36 6775 15 3500 390 (3255)

06 B32 1 36 36 6000 15 3500 390 (2490)

08 B32 1 23 23 12000 15 6000 255 (6000)

09 B16 1 23 23 2925 46 560 645 610 645 (560)

21 B20 1 31 31 8350 00

75 B10 1 192 192 950 11 580 (370)

76 B16 1 192 192 1125 27 570 205 (370) 330

84 B32 1 12 12 6625 15 3385 390 (3240)

101 B32 1 26 26 5600 00

US-TU 01 B20 1 72 72 4500 01

03 B32 1 32 32 12000 15 6000 265 (6000)

04 B32 1 72 72 7300 01

05 B16 1 36 36 2350 99 1145 155 (1145) 39

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

31 5 of 5 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
US-TU 5 B16 1 36 36 2550 99 1255 160 (1255) 39

US-TU 77 B12 1 22 22 1125 51 160 300 (160) (160)

78 B16 1 52 52 1525 51 335 300 (210) (210)

79 B16 1 52 52 1575 56 A=360 B=300 C=330 D=(295) E=(210)


F=(210)

80 B16 1 52 52 1800 56 A=500 B=300 C=400 D=(300) E=(210)


F=(210)

81 B16 1 52 52 1425 51 280 300 (210) (210)

82 B16 1 52 52 1375 51 280 280 (210) (210)

83 B16 1 52 52 2250 56 A=740 B=300 C=580 D=(320) E=(210)


F=(210)

85 B16 1 4 4 3175 21 1500 220 (1500)

86 B16 1 4 4 3175 21 1500 230 (1500)

87 B16 1 4 4 3200 21 1500 250 (1500)

88 B16 1 4 4 3225 21 1500 270 (1500)

89 B16 1 4 4 3225 21 1500 280 (1500)

90 B16 1 4 4 3250 21 1500 300 (1500)

98 B32 1 8 8 5600 00

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
T1 & T2 S5b T1 & T2 S5b T1 & T2 S5b T1 & T2 S5b T1 & T2 S5b
7150 7150 7150 7150 7150

BOTTOM SLAB BOTTOM SLAB BOTTOM SLAB BOTTOM SLAB BOTTOM SLAB LINKS
TRANSVERSAL UPPER LONGITUDINAL UPPER TRANSVERSAL BOTTOM LONGITUDINAL BOTTOM SCALE 1:100
SCALE 1:100 SCALE 1:100 SCALE 1:100 SCALE 1:100

REINFORCEMENT

1. REINFORCING BARS, INCLUDING HELICAL REINFORCEMENT, BUT NOT FABRIC


REINFORCEMENT AND DOWELS ARE SCALED UP ON THE DRAWINGS IN THE FOLLOWING
MANNER:
NO OFF: BAR TYPE: BAR DIAMETER - BAR MARK - PITCH: POSITION AND/OR COMMENT
E.G. 7 H20 09-125-B1
BAR TYPE DESIGNATION IS AS FOLLOWS: GENERAL NOTES
B = GRADE B500B OR B500C RIBBED BARS COMPLYING WITH BS 4449
S = GRADE 1.4301 STAINLESS STEEL REINFORCEMENT COMPLYING WITH
BS EN 10088-1
CONCRETE CLASS 50 (MPa)
POSITION/COMMENT IS DESIGNATED AS FOLLOWS:
CONCRETE COVER: 50mm
T = TOP FACE, B = BOTTOM FACE, NF = NEAR FACE, FF = FAR FACE
CONCRETE COVER IN CONTACT WITH CONCRETE: 10mm
ABR = ALTERNATE BARS REVERSED
STG = ALTERNATE BAR STAGGERED BY THE AMOUNT SHOWN
ALT = ALTERNATE BARS
COUPLER = BAR END INDICATED TO BE SWAGED FOR SCREW TYPE COUPLER
CALLOUT SHALL BE READ AS SHOWN BELOW REFERENCE DRAWINGS
WHERE TWO BAR MARKS ARE SCALED UP TOGETHER AND IDENTIFIED AS "AB", THE REINFORCEMENT
SPACING STATED IS THE SPACING OF ALL BARS NOT OF EACH BAR MARK. GENERAL NOTES
2. WHERE REINFORCEMENT COUPLERS ARE USED, THEY SHALL BE POSITIONED STEEL GRADE D630-ST-DJV-DRA-534106
SO AS TO ACHIEVE THE SAME NOMINAL COVER AS THAT SPECIFIED FOR THE D630-ST-DJV-DRA-534107
REINFORCEMENT BARS WHICH THEY COUPLE. GEOMETRY PRESTRESSING
3. STEEL SPACERS OF SIMILAR DIAMETER TO BARS BUT NOT LESS THAN 25 DIAMETER
SHALL BE PROVIDED BETWEEN ADJACENT LAYERS OF PARALLEL REINFORCEMENT AND LAYER
SPACED AT NO MORE THAN 6 0 TIMES THE SMALLER BAR DIAMETER. SCHEME
THESE SPACER BARS ARE NOT INCLUDED ON THE BAR SCHEDULES.
4. SPACERS, TIES AND STOOLS SHALL BE SUPPLIED BY
* WHEN ONLYONE IDENTIFICATION: PRECAST
THE CONTRACTOR AS NECESSARY TO SECURE THE REINFORCEMENT
XXX BAR MARK
AGAINST DISPLACEMENT .
5. PVC DUCTS ARE TO BE INSTALLED PRIOR TO CAST THE HANDRAIL.
SEE DRAWINGS D630-ST-DJV-DRA-534901 & D630-ST-DJV-DRA-534903

SUBCONTRACTOR: PROJECT: SCALE


REVISIONS
X NO. DATE DESCRIPTION BACK SPAN
A 20/03/2020 ISSUED FOR CONSTRUCTION SUPERSTRUCTURE
B 10/04/2020 ISSUED FOR CONSTRUCTION DECK REINFORCEMENT
T1-S5-b & T2-S5-b
BY: DJV C
D
DATE: 200416 B
SIGNATURE E D630-ST-CFC-SHD-8176 32
Bending Schedule Drawing No. Page No. Revision

32 1 of 1 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
BS-K 29 B8 1 340 340 325 13 150 65 (150)

45 B10 1 510 510 650 22 130 400 60 (120)

BS-LB 94 B25 1 28 28 8300 00

18C B25 1 12 12 3075 00

18D B25 1 12 12 4225 00

BS-LU 22 B20 1 28 28 8350 00

22A B20 1 12 12 3075 00

22B B20 1 12 12 4275 00

BS-TB 13 B32 1 32 32 10050 25 1250 1250 770 770 (7565)

13A B12 1 32 32 8675 25 550 550 345 350 (7565)

13B B12 1 2 2 5425 00

13C B32 1 2 2 5425 00

BS-TU 14 B25 1 32 32 10200 25 835 795 520 495 (8570)

96 B20 1 64 64 3850 15 790 490 (3045)

97 B20 1 4 4 5425 00

14A B25 1 4 4 5425 00

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
T1 & T2 S5b T1 & T2 S5b
7150 7150

WEBS WEBS
TRANSVERSAL OUTER LONGITUDINAL OUTER
SCALE 1:30 SCALE 1:30

T1 & T2 S5b
T1 & T2 S5b 7150
7150

REINFORCEMENT

1. REINFORCING BARS, INCLUDING HELICAL REINFORCEMENT, BUT NOT FABRIC


REINFORCEMENT AND DOWELS ARE SCALED UP ON THE DRAWINGS IN THE FOLLOWING
MANNER:
NO OFF: BAR TYPE: BAR DIAMETER - BAR MARK - PITCH: POSITION AND/OR COMMENT
E.G. 7 H20 09-125-B1
BAR TYPE DESIGNATION IS AS FOLLOWS:
B = GRADE B500B OR B500C RIBBED BARS COMPLYING WITH BS 4449
S = GRADE 1.4301 STAINLESS STEEL REINFORCEMENT COMPLYING WITH
BS EN 10088-1
POSITION/COMMENT IS DESIGNATED AS FOLLOWS:
T = TOP FACE, B = BOTTOM FACE, NF = NEAR FACE, FF = FAR FACE
ABR = ALTERNATE BARS REVERSED
STG = ALTERNATE BAR STAGGERED BY THE AMOUNT SHOWN
ALT = ALTERNATE BARS
COUPLER = BAR END INDICATED TO BE SWAGED FOR SCREW TYPE COUPLER
WHERE TWO BAR MARKS ARE SCALED UP TOGETHER AND IDENTIFIED AS "AB", THE
SPACING STATED IS THE SPACING OF ALL BARS NOT OF EACH BAR MARK.
2. WHERE REINFORCEMENT COUPLERS ARE USED, THEY SHALL BE POSITIONED
SO AS TO ACHIEVE THE SAME NOMINAL COVER AS THAT SPECIFIED FOR THE
WEBS REINFORCEMENT BARS WHICH THEY COUPLE.
3. STEEL SPACERS OF SIMILAR DIAMETER TO BARS BUT NOT LESS THAN 25 DIAMETER
WEBS LINKS TRANSVERSAL INNER SHALL BE PROVIDED BETWEEN ADJACENT LAYERS OF PARALLEL REINFORCEMENT AND
SCALE 1:30 SPACED AT NO MORE THAN 6 0 TIMES THE SMALLER BAR DIAMETER.
SCALE 1:30
THESE SPACER BARS ARE NOT INCLUDED ON THE BAR SCHEDULES.
4. SPACERS, TIES AND STOOLS SHALL BE SUPPLIED BY
THE CONTRACTOR AS NECESSARY TO SECURE THE REINFORCEMENT
T1 & T2 S5b AGAINST DISPLACEMENT .
7150 5. PVC DUCTS ARE TO BE INSTALLED PRIOR TO CAST THE HANDRAIL.
SEE DRAWINGS D630-ST-DJV-DRA-534901 & D630-ST-DJV-DRA-534903

GENERAL NOTES

CONCRETE CLASS 50 (MPa)


CONCRETE COVER: 50mm
CONCRETE COVER IN CONTACT WITH CONCRETE: 10mm

CALLOUT SHALL BE READ AS SHOWN BELOW REFERENCE DRAWINGS


REINFORCEMENT
GENERAL NOTES
STEEL GRADE D630-ST-DJV-DRA-534106
D630-ST-DJV-DRA-534107
GEOMETRY PRESTRESSING

LAYER

* WHEN ONLYONE IDENTIFICATION: PRECAST SCHEME


XXX BAR MARK

WEBS
LONGITUDINAL INNER
SCALE 1:30
SUBCONTRACTOR: PROJECT: SCALE
REVISIONS
X NO. DATE DESCRIPTION BACK SPAN
A 20/03/2020 ISSUED FOR CONSTRUCTION SUPERSTRUCTURE
B 10/04/2020 ISSUED FOR CONSTRUCTION DECK REINFORCEMENT
T1-S5-b & T2-S5-b
BY:
DJV C
D
DATE: 200416 B
SIGNATURE E D630-ST-CFC-SHD-8176 33
Bending Schedule Drawing No. Page No. Revision

33 1 of 1 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
W-K 46 B10 1 540 540 550 22 130 300 60 (120)

W-LI 23 B20 1 36 36 8000 00

23A B20 1 4 4 3075 00

23B B20 1 4 4 3925 00

W-LO 44 B20 1 42 42 8000 00

44A B20 1 10 10 3075 00

44B B20 1 10 10 3925 00

W-TI 10 B16 1 72 72 1175 00

12 B16 1 66 66 1025 00

15 B32 1 64 64 5975 15 4735 2830 (1245)

91 B32 1 32 32 3050 15 1895 1150 (1165)

93 B32 1 32 32 3050 15 1895 1150 (1165)

15A B32 1 8 8 5575 15 4330 2590 (1245)

W-TO 11 B16 1 72 72 1550 00

16 B32 1 64 64 6650 15 5405 3340 (1250)

16A B32 1 8 8 5875 15 4635 2865 (1250)

16B B16 1 64 64 6650 15 5405 3340 (1250)

16C B16 1 8 8 5900 15 4635 2865 (1250)

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
1 2

1 2

TRANSVERSE RIB
SCALE 1:25

SCHEME. PLAN
SCALE 1:10

SECTION 1-1 SECTION 2-2


SCALE 1:10 SCALE 1:10

REINFORCEMENT

1. REINFORCING BARS, INCLUDING HELICAL REINFORCEMENT, BUT NOT FABRIC


REINFORCEMENT AND DOWELS ARE SCALED UP ON THE DRAWINGS IN THE FOLLOWING
MANNER:
NO OFF: BAR TYPE: BAR DIAMETER - BAR MARK - PITCH: POSITION AND/OR COMMENT
E.G. 7 H20 09-125-B1
BAR TYPE DESIGNATION IS AS FOLLOWS: GENERAL NOTES
B = GRADE B500B OR B500C RIBBED BARS COMPLYING WITH BS 4449
S = GRADE 1.4301 STAINLESS STEEL REINFORCEMENT COMPLYING WITH
BS EN 10088-1
CONCRETE CLASS 50 (MPa)
POSITION/COMMENT IS DESIGNATED AS FOLLOWS:
CONCRETE COVER: 50mm
T = TOP FACE, B = BOTTOM FACE, NF = NEAR FACE, FF = FAR FACE
CONCRETE COVER IN CONTACT WITH CONCRETE: 10mm
ABR = ALTERNATE BARS REVERSED
STG = ALTERNATE BAR STAGGERED BY THE AMOUNT SHOWN
ALT = ALTERNATE BARS
COUPLER = BAR END INDICATED TO BE SWAGED FOR SCREW TYPE COUPLER
CALLOUT SHALL BE READ AS SHOWN BELOW REFERENCE DRAWINGS
WHERE TWO BAR MARKS ARE SCALED UP TOGETHER AND IDENTIFIED AS "AB", THE REINFORCEMENT
SPACING STATED IS THE SPACING OF ALL BARS NOT OF EACH BAR MARK. GENERAL NOTES
2. WHERE REINFORCEMENT COUPLERS ARE USED, THEY SHALL BE POSITIONED STEEL GRADE D630-ST-DJV-DRA-534106
SO AS TO ACHIEVE THE SAME NOMINAL COVER AS THAT SPECIFIED FOR THE D630-ST-DJV-DRA-534107
REINFORCEMENT BARS WHICH THEY COUPLE. GEOMETRY PRESTRESSING
3. STEEL SPACERS OF SIMILAR DIAMETER TO BARS BUT NOT LESS THAN 25 DIAMETER
SHALL BE PROVIDED BETWEEN ADJACENT LAYERS OF PARALLEL REINFORCEMENT AND LAYER
SPACED AT NO MORE THAN 6 0 TIMES THE SMALLER BAR DIAMETER.
THESE SPACER BARS ARE NOT INCLUDED ON THE BAR SCHEDULES.
4. SPACERS, TIES AND STOOLS SHALL BE SUPPLIED BY
THE CONTRACTOR AS NECESSARY TO SECURE THE REINFORCEMENT
* WHEN ONLYONE IDENTIFICATION: PRECAST SCHEME
XXX BAR MARK
AGAINST DISPLACEMENT .
5. PVC DUCTS ARE TO BE INSTALLED PRIOR TO CAST THE HANDRAIL.
SEE DRAWINGS D630-ST-DJV-DRA-534901 & D630-ST-DJV-DRA-534903

SUBCONTRACTOR: PROJECT: SCALE


REVISIONS
X NO. DATE DESCRIPTION BACK SPAN
A 20/03/2020 ISSUED FOR CONSTRUCTION SUPERSTRUCTURE
B 10/04/2020 ISSUED FOR CONSTRUCTION DECK REINFORCEMENT
T1-S5-b & T2-S5-b
BY:
DJV C

DATE: 200416 D
B
SIGNATURE E D630-ST-CFC-SHD-8176 34
Bending Schedule Drawing No. Page No. Revision

34 1 of 1 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
TR 49 B12 1 276 276 1100 51 250 200 (160) (160)

53 B20 1 136 136 2325 56 A=495 B=520 C=455 D=(510) E=(290)


F=(290)

57 B32 1 16 16 12000 15 10575 455 (1425)

58 B25 1 5 5 11500 15 5750 260 (5750)

59 B20 1 6 6 6000 15 3000 140 (3000)

62 B20 1 4 4 4975 99 700 3295 570 235 (985)

TR 64 B20 1 4 4 5300 00

65 B20 1 4 4 5300 15 3305 230 (1985)

66 B16 1 10 10 1100 00

70 B12 1 110 110 1650 51 515 200 (160) (160)

73 B12 1 10 10 1800 51 595 200 (160) (160)

58A B25 1 10 10 3300 99 800 1500 645 120 (995)

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
F D G E

F D E

SECTION A-A F D E B B
SCALE 1:15
H

A A
F D G E

C C

F D E

VIEW FROM G
SECTION B-B F E
SCALE 1:15
SCALE 1:15
D H

F D G E

REINFORCEMENT

1. REINFORCING BARS, INCLUDING HELICAL REINFORCEMENT, BUT NOT FABRIC


REINFORCEMENT AND DOWELS ARE SCALED UP ON THE DRAWINGS IN THE FOLLOWING
MANNER:
NO OFF: BAR TYPE: BAR DIAMETER - BAR MARK - PITCH: POSITION AND/OR COMMENT
E.G. 7 H20 09-125-B1
BAR TYPE DESIGNATION IS AS FOLLOWS:
B = GRADE B500B OR B500C RIBBED BARS COMPLYING WITH BS 4449
S = GRADE 1.4301 STAINLESS STEEL REINFORCEMENT COMPLYING WITH
GENERAL NOTES BS EN 10088-1
POSITION/COMMENT IS DESIGNATED AS FOLLOWS:
T = TOP FACE, B = BOTTOM FACE, NF = NEAR FACE, FF = FAR FACE
ABR = ALTERNATE BARS REVERSED
CONCRETE CLASS 50 (MPa)
STG = ALTERNATE BAR STAGGERED BY THE AMOUNT SHOWN
CONCRETE COVER: 50mm
ALT = ALTERNATE BARS
CONCRETE COVER IN CONTACT WITH CONCRETE: 10mm
COUPLER = BAR END INDICATED TO BE SWAGED FOR SCREW TYPE COUPLER
WHERE TWO BAR MARKS ARE SCALED UP TOGETHER AND IDENTIFIED AS "AB", THE
SPACING STATED IS THE SPACING OF ALL BARS NOT OF EACH BAR MARK.
2. WHERE REINFORCEMENT COUPLERS ARE USED, THEY SHALL BE POSITIONED
CALLOUT SHALL BE READ AS SHOWN BELOW REFERENCE DRAWINGS
REINFORCEMENT SO AS TO ACHIEVE THE SAME NOMINAL COVER AS THAT SPECIFIED FOR THE
GENERAL NOTES REINFORCEMENT BARS WHICH THEY COUPLE.
STEEL GRADE D630-ST-DJV-DRA-534106
3. STEEL SPACERS OF SIMILAR DIAMETER TO BARS BUT NOT LESS THAN 25 DIAMETER
D630-ST-DJV-DRA-534107
SHALL BE PROVIDED BETWEEN ADJACENT LAYERS OF PARALLEL REINFORCEMENT AND
GEOMETRY PRESTRESSING
SPACED AT NO MORE THAN 6 0 TIMES THE SMALLER BAR DIAMETER.
F D E THESE SPACER BARS ARE NOT INCLUDED ON THE BAR SCHEDULES.
SECTION C-C H LAYER 4. SPACERS, TIES AND STOOLS SHALL BE SUPPLIED BY
SCALE 1:15 THE CONTRACTOR AS NECESSARY TO SECURE THE REINFORCEMENT
AGAINST DISPLACEMENT .
* WHEN ONLYONE IDENTIFICATION: PRECAST 5. PVC DUCTS ARE TO BE INSTALLED PRIOR TO CAST THE HANDRAIL.
XXX BAR MARK SEE DRAWINGS D630-ST-DJV-DRA-534901 & D630-ST-DJV-DRA-534903

SUBCONTRACTOR: PROJECT: SCALE


REVISIONS
X NO. DATE DESCRIPTION BACK SPAN
A 20/03/2020 ISSUED FOR CONSTRUCTION SUPERSTRUCTURE
B 10/04/2020 ISSUED FOR CONSTRUCTION DECK REINFORCEMENT
T1-S5-b & T2-S5-b ANCHOR RIB (1)
BY:
DJV C
D
DATE: 200416 B
SIGNATURE E D630-ST-CFC-SHD-8176 35
Bending Schedule Drawing No. Page No. Revision

35 1 of 5 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUE FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
ANCHOR RIB 109 B16 1 4 4 4450 99 A=965 B=895 C=1180 D=1025 E=(210)
F=775 G=705 H=490

ANCHOR RIB 110 B16 1 4 4 5275 99 A=1750 B=860 C=420 D=635 E=635
F=1025 G=705 H=1045 I=1115

ANCHOR RIB 111 B20 1 3 3 5250 29 2330 530 (2400) 515

112 B32 1 8 8 6525 46 1560 445 2610 345 (1535)

113 B25 1 4 4 4800 99 A=1155 B=450 C=680 D=2600 E=270


F=315 G=485 H=430

ANCHOR RIB 114 B25 1 4 4 3575 99 A=1660 B=365 C=765 D=865 E=210
F=260 G=540 H=495
B=Steel reinforcement grade B500B to BS4449 2005
S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

35 2 of 5 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUE FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
ANCHOR RIB 117 B25 1 2 2 4400 99 A=845 B=740 C=390 D=2505 E=475
F=525 G=275 H=230

ANCHOR RIB 118 B25 1 2 2 4400 99 A=910 B=640 C=325 D=2605 E=405
F=455 G=230 H=180

ANCHOR RIB 119 B25 1 2 2 4275 29 2745 485 (1095) 500

120 B25 1 2 2 3850 99 A=1170 B=425 C=700 D=1635 E=255


F=300 G=495 H=450

ANCHOR RIB 121 B25 1 2 2 3750 99 A=1245 B=330 C=625 D=1630 E=185
F=230 G=440 H=395

ANCHOR RIB 122 B25 1 2 2 3400 29 1340 495 (1595) 500


B=Steel reinforcement grade B500B to BS4449 2005
S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

35 3 of 5 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUE FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
ANCHOR RIB 123 B20 1 3 3 5300 29 2370 545 (2400) 515

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
C A G B

F D E

B B

SECTION D-D H
SCALE 1:15
C A B A A

C A G B C C

F D E

VIEW FROM H
SCALE 1:15

SECTION E-E H
SCALE 1:15
C A B

REINFORCEMENT

C A G B 1. REINFORCING BARS, INCLUDING HELICAL REINFORCEMENT, BUT NOT FABRIC


REINFORCEMENT AND DOWELS ARE SCALED UP ON THE DRAWINGS IN THE FOLLOWING
MANNER:
NO OFF: BAR TYPE: BAR DIAMETER - BAR MARK - PITCH: POSITION AND/OR COMMENT
E.G. 7 H20 09-125-B1
BAR TYPE DESIGNATION IS AS FOLLOWS:
B = GRADE B500B OR B500C RIBBED BARS COMPLYING WITH BS 4449
S = GRADE 1.4301 STAINLESS STEEL REINFORCEMENT COMPLYING WITH
GENERAL NOTES BS EN 10088-1
POSITION/COMMENT IS DESIGNATED AS FOLLOWS:
T = TOP FACE, B = BOTTOM FACE, NF = NEAR FACE, FF = FAR FACE
ABR = ALTERNATE BARS REVERSED
CONCRETE CLASS 50 (MPa)
STG = ALTERNATE BAR STAGGERED BY THE AMOUNT SHOWN
CONCRETE COVER: 50mm
ALT = ALTERNATE BARS
CONCRETE COVER IN CONTACT WITH CONCRETE: 10mm
COUPLER = BAR END INDICATED TO BE SWAGED FOR SCREW TYPE COUPLER
WHERE TWO BAR MARKS ARE SCALED UP TOGETHER AND IDENTIFIED AS "AB", THE
SPACING STATED IS THE SPACING OF ALL BARS NOT OF EACH BAR MARK.
2. WHERE REINFORCEMENT COUPLERS ARE USED, THEY SHALL BE POSITIONED
CALLOUT SHALL BE READ AS SHOWN BELOW REFERENCE DRAWINGS
REINFORCEMENT SO AS TO ACHIEVE THE SAME NOMINAL COVER AS THAT SPECIFIED FOR THE
GENERAL NOTES REINFORCEMENT BARS WHICH THEY COUPLE.
STEEL GRADE D630-ST-DJV-DRA-534106
3. STEEL SPACERS OF SIMILAR DIAMETER TO BARS BUT NOT LESS THAN 25 DIAMETER
D630-ST-DJV-DRA-534107
SHALL BE PROVIDED BETWEEN ADJACENT LAYERS OF PARALLEL REINFORCEMENT AND
GEOMETRY PRESTRESSING
SPACED AT NO MORE THAN 6 0 TIMES THE SMALLER BAR DIAMETER.
THESE SPACER BARS ARE NOT INCLUDED ON THE BAR SCHEDULES.
LAYER 4. SPACERS, TIES AND STOOLS SHALL BE SUPPLIED BY
SECTION F-F C A H B
THE CONTRACTOR AS NECESSARY TO SECURE THE REINFORCEMENT
AGAINST DISPLACEMENT .
SCALE 1:15 PRECAST 5. PVC DUCTS ARE TO BE INSTALLED PRIOR TO CAST THE HANDRAIL.
* WHEN ONLYONE IDENTIFICATION:
XXX BAR MARK SEE DRAWINGS D630-ST-DJV-DRA-534901 & D630-ST-DJV-DRA-534903

SUBCONTRACTOR: PROJECT: SCALE


REVISIONS
X NO. DATE DESCRIPTION BACK SPAN
A 20/03/2020 ISSUED FOR CONSTRUCTION SUPERSTRUCTURE
B 10/04/2020 ISSUED FOR CONSTRUCTION DECK REINFORCEMENT

DJV C
T1-S5-b & T2-S5-b ANCHOR RIB (2)
BY:
DATE: 200416 D
B
SIGNATURE E D630-ST-CFC-SHD-8176 36
Bending Schedule Drawing No. Page No. Revision

36 1 of 1 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUE FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
ANCHOR RIB 101 B20 1 16 16 2500 13 1205 200 (1200)

102 B20 1 48 48 3700 99 A=290 B=840 C=290 D=455 E=325


F=345 G=300 H=290 J=300

ANCHOR RIB 103 B25 1 18 18 5225 46 1185 835 1215 425 (1185)

104 B32 1 24 24 5050 15 2525 135 (2525)

105 B20 1 5 5 2575 51 610 520 (290) (290)

106 B25 1 4 4 5725 46 1530 725 1285 570 (1525)

107 B16 1 48 48 3650 99 A=210 B=840 C=290 D=455 E=325


F=345 G=300 H=290 J=300

ANCHOR RIB 108 B32 1 1 1 4000 15 2000 120 (2000)

115 B32 1 1 1 4275 46 900 415 1670 265 (900)

116 B32 1 1 1 4450 46 945 520 1550 430 (1005)

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
A

GENERAL NOTES

CONCRETE CLASS 50 (MPa)


CONCRETE COVER: 50mm
CONCRETE COVER IN CONTACT WITH CONCRETE: 10mm

CALLOUT SHALL BE READ AS SHOWN BELOW REFERENCE DRAWINGS


REINFORCEMENT
GENERAL NOTES
STEEL GRADE D630-ST-DJV-DRA-534106
D630-ST-DJV-DRA-534107
GEOMETRY PRESTRESSING
PRECAST SHOE BOTTOM SLAB t=0.50m.
WEB t=0.40m. LAYER
SCALE 1:10

* WHEN ONLYONE IDENTIFICATION: PRECAST


XXX BAR MARK

REINFORCEMENT

1. REINFORCING BARS, INCLUDING HELICAL REINFORCEMENT, BUT NOT FABRIC


REINFORCEMENT AND DOWELS ARE SCALED UP ON THE DRAWINGS IN THE FOLLOWING
MANNER:
NO OFF: BAR TYPE: BAR DIAMETER - BAR MARK - PITCH: POSITION AND/OR COMMENT
E.G. 7 H20 09-125-B1
BAR TYPE DESIGNATION IS AS FOLLOWS:
B = GRADE B500B OR B500C RIBBED BARS COMPLYING WITH BS 4449
S = GRADE 1.4301 STAINLESS STEEL REINFORCEMENT COMPLYING WITH
BS EN 10088-1
POSITION/COMMENT IS DESIGNATED AS FOLLOWS:
T = TOP FACE, B = BOTTOM FACE, NF = NEAR FACE, FF = FAR FACE
ABR = ALTERNATE BARS REVERSED
STG = ALTERNATE BAR STAGGERED BY THE AMOUNT SHOWN
ALT = ALTERNATE BARS
COUPLER = BAR END INDICATED TO BE SWAGED FOR SCREW TYPE COUPLER
WHERE TWO BAR MARKS ARE SCALED UP TOGETHER AND IDENTIFIED AS "AB", THE
SPACING STATED IS THE SPACING OF ALL BARS NOT OF EACH BAR MARK.
2. WHERE REINFORCEMENT COUPLERS ARE USED, THEY SHALL BE POSITIONED
SO AS TO ACHIEVE THE SAME NOMINAL COVER AS THAT SPECIFIED FOR THE
REINFORCEMENT BARS WHICH THEY COUPLE.
3. STEEL SPACERS OF SIMILAR DIAMETER TO BARS BUT NOT LESS THAN 25 DIAMETER
SHALL BE PROVIDED BETWEEN ADJACENT LAYERS OF PARALLEL REINFORCEMENT AND
SPACED AT NO MORE THAN 6 0 TIMES THE SMALLER BAR DIAMETER.
THESE SPACER BARS ARE NOT INCLUDED ON THE BAR SCHEDULES.
4. SPACERS, TIES AND STOOLS SHALL BE SUPPLIED BY
THE CONTRACTOR AS NECESSARY TO SECURE THE REINFORCEMENT
AGAINST DISPLACEMENT .
VIEW FROM A 5. PVC DUCTS ARE TO BE INSTALLED PRIOR TO CAST THE HANDRAIL.
SCALE 1:10 SEE DRAWINGS D630-ST-DJV-DRA-534901 & D630-ST-DJV-DRA-534903

SUBCONTRACTOR: PROJECT: SCALE


REVISIONS
X NO. DATE DESCRIPTION BACK SPAN
A 20/03/2020 ISSUED FOR CONSTRUCTION SUPERSTRUCTURE
B 10/04/2020 ISSUED FOR CONSTRUCTION DECK REINFORCEMENT
T1-S5-b & T2-S5-b PRECAST-SHOE
BY: DJV C

DATE: 200416 D
B
SIGNATURE E D630-ST-CFC-SHD-8176 37
Bending Schedule Drawing No. Page No. Revision

37 1 of 4 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
PRCS-T50-W40 01 B32 1 8 8 5750 15 3160 1915 (2585)

02 B32 1 8 8 5825 15 2800 1700 (3035)

03 B25 1 6 6 4600 00

04 B25 1 15 15 3600 00

05 B25 1 8 8 4300 15 1435 880 (2870)

06 B25 1 5 5 1825 25 250 295 235 295 (1335)

07 B12 1 4 4 1375 99 500 85 160 160

PRCS-T50-W40 08 B12 1 4 4 1575 99 610 85 160 160

PRCS-T50-W40 09 B12 1 4 4 1425 99 525 85 160 160

PRCS-T50-W40 10a B12 1 1 1 1425 21 375 700 (375)

10b B12 1 1 1 1525 21 425 700 (425)

10c B12 1 1 1 1625 21 475 700 (475)

10d B12 1 1 1 1725 21 525 700 (525)

11a B12 1 2 2 750 21 505 160 (125)

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

37 2 of 4 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
PRCS-T50-W40 11b B12 1 2 2 725 21 485 160 (125)

11c B12 1 2 2 725 21 465 160 (125)

11d B12 1 2 2 700 21 445 160 (125)

11e B12 1 2 2 675 21 425 160 (125)

11f B12 1 2 2 650 21 405 160 (125)

11g B12 1 2 2 625 21 385 160 (125)

12 B12 1 1 1 1375 21 360 700 (360)

13a B12 1 1 1 650 21 180 330 (180)

13b B12 1 1 1 650 21 175 330 (175)

13c B12 1 1 1 625 21 165 330 (165)

13d B12 1 1 1 600 21 155 330 (155)

13e B12 1 1 1 575 21 145 330 (145)

13f B12 1 1 1 575 21 135 330 (135)

13g B12 1 1 1 550 21 125 330 (125)

14 B16 1 4 4 750 00

15 B16 1 4 4 850 00

16 B16 1 4 4 950 00

17 B16 1 4 4 900 00

18 B16 1 4 4 850 00

19 B16 1 4 4 725 00

20 B16 1 2 2 1500 11 380 (1150)

21 B16 1 2 2 1600 11 475 (1150)

22 B16 1 2 2 1700 11 575 (1150)

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

37 3 of 4 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

BACK SPAN Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
PRCS-T50-W40 23 B16 1 2 2 1700 11 575 (1150)

24 B16 1 2 2 1700 11 575 (1150)

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
A

VIEW A. PRECAST SHOE


SCALE 1:10
DETAIL. PRECAST SHOE
SCALE 1:10

DETAIL STUD
SCALE 1:5

REINFORCEMENT

1. REINFORCING BARS, INCLUDING HELICAL REINFORCEMENT, BUT NOT FABRIC


REINFORCEMENT AND DOWELS ARE SCALED UP ON THE DRAWINGS IN THE FOLLOWING
DETAIL. VIEW
MANNER:
NO OFF: BAR TYPE: BAR DIAMETER - BAR MARK - PITCH: POSITION AND/OR COMMENT
E.G. 7 H20 09-125-B1
BAR TYPE DESIGNATION IS AS FOLLOWS:
B = GRADE B500B OR B500C RIBBED BARS COMPLYING WITH BS 4449
S = GRADE 1.4301 STAINLESS STEEL REINFORCEMENT COMPLYING WITH GENERAL NOTES
BS EN 10088-1
POSITION/COMMENT IS DESIGNATED AS FOLLOWS:
T = TOP FACE, B = BOTTOM FACE, NF = NEAR FACE, FF = FAR FACE CONCRETE CLASS 50 (MPa)
ABR = ALTERNATE BARS REVERSED CONCRETE COVER: 50mm
STG = ALTERNATE BAR STAGGERED BY THE AMOUNT SHOWN CONCRETE COVER IN CONTACT WITH CONCRETE: 10mm
ALT = ALTERNATE BARS
COUPLER = BAR END INDICATED TO BE SWAGED FOR SCREW TYPE COUPLER
WHERE TWO BAR MARKS ARE SCALED UP TOGETHER AND IDENTIFIED AS "AB", THE
SPACING STATED IS THE SPACING OF ALL BARS NOT OF EACH BAR MARK. CALLOUT SHALL BE READ AS SHOWN BELOW REFERENCE DRAWINGS
2. WHERE REINFORCEMENT COUPLERS ARE USED, THEY SHALL BE POSITIONED REINFORCEMENT
SO AS TO ACHIEVE THE SAME NOMINAL COVER AS THAT SPECIFIED FOR THE GENERAL NOTES
STEEL GRADE D630-ST-DJV-DRA-534106
REINFORCEMENT BARS WHICH THEY COUPLE.
D630-ST-DJV-DRA-534107
3. STEEL SPACERS OF SIMILAR DIAMETER TO BARS BUT NOT LESS THAN 25 DIAMETER
GEOMETRY PRESTRESSING
SHALL BE PROVIDED BETWEEN ADJACENT LAYERS OF PARALLEL REINFORCEMENT AND
SPACED AT NO MORE THAN 6 0 TIMES THE SMALLER BAR DIAMETER.
THESE SPACER BARS ARE NOT INCLUDED ON THE BAR SCHEDULES. LAYER
4. SPACERS, TIES AND STOOLS SHALL BE SUPPLIED BY
THE CONTRACTOR AS NECESSARY TO SECURE THE REINFORCEMENT
AGAINST DISPLACEMENT . * WHEN ONLYONE IDENTIFICATION: PRECAST
5. PVC DUCTS ARE TO BE INSTALLED PRIOR TO CAST THE HANDRAIL. XXX BAR MARK
SEE DRAWINGS D630-ST-DJV-DRA-534901 & D630-ST-DJV-DRA-534903

SUBCONTRACTOR: PROJECT: SCALE


REVISIONS
X NO. DATE DESCRIPTION BACK SPAN
A 20/03/2020 ISSUED FOR CONSTRUCTION SUPERSTRUCTURE
B 10/04/2020 ISSUED FOR CONSTRUCTION DECK REINFORCEMENT
T1-S5-b & T2-S5-b PRECAST-SHOE
BY: DJV C

DATE: 200416 D
B
SIGNATURE E D630-ST-CFC-SHD-8176 38
DETAIL
BM-06 (TYPE-2B)
BM-37 (TYPE-4B)
SCALE 1:20

REINFORCEMENT

1. REINFORCING BARS, INCLUDING HELICAL REINFORCEMENT, BUT NOT FABRIC


REINFORCEMENT AND DOWELS ARE CALLED UP ON THE DRAWINGS IN THE FOLLOWING
MANNER:
NO OFF: BAR TYPE: BAR DIAMETER - BAR MARK - PITCH: POSITION AND/OR COMMENT
E.G. 7 H20 09-125-B1
BAR TYPE DESIGNATION IS AS FOLLOWS:
B = GRADE B500B OR B500C RIBBED BARS COMPLYING WITH BS 4449
S = GRADE 1.4301 STAINLESS STEEL REINFORCEMENT COMPLYING WITH
BS EN 10088-1
POSITION/COMMENT IS DESIGNATED AS FOLLOWS:
T = TOP FACE, B = BOTTOM FACE, NF = NEAR FACE, FF = FAR FACE
ABR = ALTERNATE BARS REVERSED
GENERAL NOTES
STG = ALTERNATE BAR STAGGERED BY THE AMOUNT SHOWN
ALT = ALTERNATE BARS
COUPLER = BAR END INDICATED TO BE SWAGED FOR SCREW TYPE COUPLER
CONCRETE CLASS 50 (MPa) WHERE TWO BAR MARKS ARE CALLED UP TOGETHER AND IDENTIFIED AS "AB", THE
CONCRETE COVER: 50mm SPACING STATED IS THE SPACING OF ALL BARS NOT OF EACH BAR MARK.
CONCRETE COVER IN CONTACT WITH CONCRETE: 10mm 2. WHERE REINFORCEMENT COUPLERS ARE USED, THEY SHALL BE POSITIONED
SO AS TO ACHIEVE THE SAME NOMINAL COVER AS THAT SPECIFIED FOR THE
REINFORCEMENT BARS WHICH THEY COUPLE.
3. STEEL SPACERS OF SIMILAR DIAMETER TO BARS BUT NOT LESS THAN 25 DIAMETER
CALLOUT SHALL BE READ AS SHOWN BELOW REFERENCE DRAWINGS
REINFORCEMENT SHALL BE PROVIDED BETWEEN ADJACENT LAYERS OF PARALLEL REINFORCEMENT AND
GENERAL NOTES SPACED AT NO MORE THAN 6 0 TIMES THE SMALLER BAR DIAMETER.
STEEL GRADE D630-ST-DJV-DRA-534106 THESE SPACER BARS ARE NOT INCLUDED ON THE BAR SCHEDULES.
D630-ST-DJV-DRA-534107
4. SPACERS, TIES AND STOOLS SHALL BE SUPPLIED BY
GEOMETRY PRESTRESSING THE CONTRACTOR AS NECESSARY TO SECURE THE REINFORCEMENT
AGAINST DISPLACEMENT .
LAYER 5. PVC DUCTS ARE TO BE INSTALLED PRIOR TO CAST THE HANDRAIL.
SEE DRAWINGS D630-ST-DJV-DRA-534901 & D630-ST-DJV-DRA-534903
6. THE REINFORCEMENT SHOWN IN THE DRAWING AND IN THE REBAR SCHEDULE REFERS
* WHEN ONLYONE IDENTIFICATION: PRECAST TO ONE SINGLE BLISTER. TO OBTAIN THE TOTAL REINFORCEMENT QUANTITY OF ALL
XXX BAR MARK BLISTERS THESE VALUES MUST BE MULTIPLIED BY THE TOTAL NUMBER OF BLISTERS.

SUBCONTRACTOR: PROJECT: SCALE


REVISIONS
X NO. DATE DESCRIPTION BACK SPAN
A 20/03/2020 ISSUED FOR CONSTRUCTION SUPERSTRUCTURE
B 10/04/2020 ISSUED FOR CONSTRUCTION REINFORCEMENT

DJV C
T1-S5-b & T2-S5-b PRESTRESSING BLISTERS - 1
BY:
DATE: 200416 D
B
SIGNATURE E D630-ST-CFC-SHD-8176 39
Bending Schedule Drawing No. Page No. Revision

39 1 of 6 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

T1-S5-b & T2-S5-b PRESTRESSING BLISTERS - 2 Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
TYPE-2B 01 B20 2 1 2 13575 77 500 80 9

02a B16 2 2 4 2775 51 380 880 (210) (210)

02b B16 2 2 4 2775 51 380 875 (210) (210)

02c B16 2 2 4 2775 51 380 870 (210) (210)

02d B16 2 2 4 2750 51 380 865 (210) (210)

02e B16 2 2 4 2750 51 380 860 (210) (210)

02f B16 2 2 4 2725 51 380 855 (210) (210)

02g B16 2 2 4 2725 51 380 845 (210) (210)

02h B16 2 2 4 2700 51 380 840 (210) (210)

03a B25 2 1 2 5025 99 A=985 B=1450 C=165 D=980 E=1115


F=365

TYPE-2B 03b B25 2 1 2 4975 99 A=965 B=1440 C=165 D=960 E=1115


F=365

03c B25 2 1 2 4950 99 A=945 B=1435 C=160 D=945 E=1115


F=365

03d B25 2 1 2 4900 99 A=925 B=1430 C=155 D=925 E=1115


F=365

03e B25 2 1 2 4850 99 A=905 B=1420 C=155 D=910 E=1115


F=365

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

39 2 of 6 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

T1-S5-b & T2-S5-b PRESTRESSING BLISTERS - 2 Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
TYPE-2B 03f B25 2 1 2 4825 99 A=885 B=1415 C=150 D=890 E=1115
F=365

03g B25 2 1 2 4775 99 A=865 B=1410 C=145 D=875 E=1115


F=365

04a B25 2 1 2 4650 99 A=820 B=1395 C=140 D=815 E=1115


F=365

TYPE-2B 04b B25 2 1 2 4550 99 A=780 B=1380 C=130 D=775 E=1115


F=365

04c B25 2 1 2 4450 99 A=740 B=1365 C=125 D=735 E=1115


F=365

04d B25 2 1 2 4375 99 A=700 B=1355 C=120 D=695 E=1115


F=365

04e B25 2 1 2 4275 99 A=660 B=1340 C=110 D=660 E=1115


F=365

04f B25 2 1 2 4200 99 A=620 B=1325 C=105 D=620 E=1115


F=365

04g B25 2 1 2 4100 99 A=580 B=1310 C=100 D=580 E=1115


F=365

04h B25 2 1 2 4000 99 A=540 B=1300 C=90 D=540 E=1115


F=365

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

39 3 of 6 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

T1-S5-b & T2-S5-b PRESTRESSING BLISTERS - 2 Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
TYPE-2B 04i B25 2 1 2 3925 99 A=500 B=1285 C=85 D=505 E=1115
F=365

04j B25 2 1 2 3825 99 A=460 B=1270 C=80 D=465 E=1115


F=365

05a B16 2 2 4 1950 51 300 545 (210) (210)

05b B16 2 2 4 1925 51 300 525 (210) (210)

05c B16 2 2 4 1875 51 300 505 (210) (210)

05d B16 2 2 4 1825 51 300 485 (210) (210)

05e B16 2 2 4 1800 51 300 465 (210) (210)

05f B16 2 2 4 1750 51 300 445 (210) (210)

05g B16 2 2 4 1725 51 300 425 (210) (210)

05h B16 2 2 4 1675 51 300 405 (210) (210)

06 B25 2 4 8 8175 99 800 920 4650 1800

TYPE-2B 07 B25 2 16 32 6000 00

TYPE-4B 32 B20 1 4 4 13575 77 500 80 9

33a B16 1 4 4 2775 51 380 880 (210) (210)

33b B16 1 4 4 2775 51 380 875 (210) (210)

33c B16 1 4 4 2775 51 380 870 (210) (210)

33d B16 1 4 4 2750 51 380 865 (210) (210)

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

39 4 of 6 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

T1-S5-b & T2-S5-b PRESTRESSING BLISTERS - 2 Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
TYPE-4B 33e B16 1 4 4 2750 51 380 860 (210) (210)

33f B16 1 4 4 2725 51 380 855 (210) (210)

33g B16 1 4 4 2725 51 380 845 (210) (210)

33h B16 1 4 4 2700 51 380 840 (210) (210)

34a B25 1 1 1 7425 99 A=985 B=2650 C=165 D=980 E=2315


F=365

TYPE-4B 34b B25 1 1 1 7375 99 A=965 B=2640 C=165 D=960 E=2315


F=365

34c B25 1 1 1 7350 99 A=945 B=2635 C=160 D=945 E=2315


F=365

34d B25 1 1 1 7300 99 A=925 B=2630 C=155 D=925 E=2315


F=365

34e B25 1 1 1 7250 99 A=905 B=2620 C=155 D=910 E=2315


F=365

34f B25 1 1 1 7225 99 A=885 B=2615 C=150 D=890 E=2315


F=365

34g B25 1 1 1 7175 99 A=865 B=2610 C=145 D=875 E=2315


F=365

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

39 5 of 6 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

T1-S5-b & T2-S5-b PRESTRESSING BLISTERS - 2 Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
TYPE-4B 35a B25 1 1 1 4650 99 A=820 B=1395 C=140 D=815 E=1115
F=365

TYPE-4B 35b B25 1 1 1 4550 99 A=780 B=1380 C=130 D=775 E=1115


F=365

35c B25 1 1 1 4450 99 A=740 B=1365 C=125 D=735 E=1115


F=365

35d B25 1 1 1 4375 99 A=700 B=1355 C=120 D=695 E=1115


F=365

35e B25 1 1 1 4275 99 A=660 B=1340 C=110 D=660 E=1115


F=365

35f B25 1 1 1 4200 99 A=620 B=1325 C=105 D=620 E=1115


F=365

35g B25 1 1 1 4100 99 A=580 B=1310 C=100 D=580 E=1115


F=365

35h B25 1 1 1 4000 99 A=540 B=1300 C=90 D=540 E=1115


F=365

35i B25 1 1 1 3925 99 A=500 B=1285 C=85 D=505 E=1115


F=365

35j B25 1 1 1 3825 99 A=460 B=1270 C=80 D=465 E=1115


F=365

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

39 6 of 6 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

T1-S5-b & T2-S5-b PRESTRESSING BLISTERS - 2 Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
TYPE-4B 36a B16 1 4 4 1950 51 300 545 (210) (210)

36b B16 1 4 4 1925 51 300 525 (210) (210)

36c B16 1 4 4 1875 51 300 505 (210) (210)

36d B16 1 4 4 1825 51 300 485 (210) (210)

36e B16 1 4 4 1800 51 300 465 (210) (210)

36f B16 1 4 4 1750 51 300 445 (210) (210)

36g B16 1 4 4 1725 51 300 425 (210) (210)

36h B16 1 4 4 1675 51 300 405 (210) (210)

37 B25 1 8 8 8175 99 800 920 4650 1800

TYPE-4B 38 B25 1 32 32 6000 00

39 B25 1 3 3 9825 25 875 875 540 540 (8095)

40 B20 1 3 3 8125 25 280 280 180 180 (7560)

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
REINFORCEMENT

1. REINFORCING BARS, INCLUDING HELICAL REINFORCEMENT, BUT NOT FABRIC


REINFORCEMENT AND DOWELS ARE CALLED UP ON THE DRAWINGS IN THE FOLLOWING
MANNER:
NO OFF: BAR TYPE: BAR DIAMETER - BAR MARK - PITCH: POSITION AND/OR COMMENT
E.G. 7 H20 09-125-B1
GENERAL NOTES BAR TYPE DESIGNATION IS AS FOLLOWS:
B = GRADE B500B OR B500C RIBBED BARS COMPLYING WITH BS 4449
S = GRADE 1.4301 STAINLESS STEEL REINFORCEMENT COMPLYING WITH
BS EN 10088-1
CONCRETE CLASS 50 (MPa) POSITION/COMMENT IS DESIGNATED AS FOLLOWS:
CONCRETE COVER: 50mm T = TOP FACE, B = BOTTOM FACE, NF = NEAR FACE, FF = FAR FACE
CONCRETE COVER IN CONTACT WITH CONCRETE: 10mm ABR = ALTERNATE BARS REVERSED
STG = ALTERNATE BAR STAGGERED BY THE AMOUNT SHOWN
ALT = ALTERNATE BARS
COUPLER = BAR END INDICATED TO BE SWAGED FOR SCREW TYPE COUPLER
CALLOUT SHALL BE READ AS SHOWN BELOW REFERENCE DRAWINGS WHERE TWO BAR MARKS ARE CALLED UP TOGETHER AND IDENTIFIED AS "AB", THE
REINFORCEMENT SPACING STATED IS THE SPACING OF ALL BARS NOT OF EACH BAR MARK.
GENERAL NOTES
2. WHERE REINFORCEMENT COUPLERS ARE USED, THEY SHALL BE POSITIONED
STEEL GRADE D630-ST-DJV-DRA-534106
D630-ST-DJV-DRA-534107 SO AS TO ACHIEVE THE SAME NOMINAL COVER AS THAT SPECIFIED FOR THE
REINFORCEMENT BARS WHICH THEY COUPLE.
GEOMETRY PRESTRESSING
3. STEEL SPACERS OF SIMILAR DIAMETER TO BARS BUT NOT LESS THAN 25 DIAMETER
SHALL BE PROVIDED BETWEEN ADJACENT LAYERS OF PARALLEL REINFORCEMENT AND
LAYER
SPACED AT NO MORE THAN 6 0 TIMES THE SMALLER BAR DIAMETER.
THESE SPACER BARS ARE NOT INCLUDED ON THE BAR SCHEDULES.
4. SPACERS, TIES AND STOOLS SHALL BE SUPPLIED BY
* WHEN ONLYONE IDENTIFICATION: PRECAST THE CONTRACTOR AS NECESSARY TO SECURE THE REINFORCEMENT
XXX BAR MARK AGAINST DISPLACEMENT .
5. PVC DUCTS ARE TO BE INSTALLED PRIOR TO CAST THE HANDRAIL.
SEE DRAWINGS D630-ST-DJV-DRA-534901 & D630-ST-DJV-DRA-534903
6. THE REINFORCEMENT SHOWN IN THE DRAWING AND IN THE REBAR SCHEDULE REFERS
TO ONE SINGLE BLISTER. TO OBTAIN THE TOTAL REINFORCEMENT QUANTITY OF ALL
BLISTERS THESE VALUES MUST BE MULTIPLIED BY THE TOTAL NUMBER OF BLISTERS.

SUBCONTRACTOR: PROJECT: SCALE


REVISIONS
X NO. DATE DESCRIPTION BACK SPAN
A 20/03/2020 ISSUED FOR CONSTRUCTION SUPERSTRUCTURE
B 10/04/2020 ISSUED FOR CONSTRUCTION REINFORCEMENT
T1-S5-b & T2-S5-b PRESTRESSING BLISTERS - 2
BY: DJV C

DATE: 200416 D
B
SIGNATURE E D630-ST-CFC-SHD-8176 40
Bending Schedule Drawing No. Page No. Revision

40 1 of 2 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

PRESTRESSING BLISTERS - 2 Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
TYPE-2B 30 B25 2 3 6 9825 25 875 875 540 540 (8095)

31 B20 2 3 6 8125 25 280 280 180 180 (7560)

TYPE-2T 1 B20 2 1 2 13575 77 500 80 9

07 B25 2 8 16 6000 00

14 B25 2 15 30 5000 56 A=1650 B=800 C=1145 D=(895) E=365


F=(365)

15 B16 2 8 16 4250 56 A=1675 B=400 C=1415 D=(455) E=210


F=(210)

22 B20 2 6 12 4425 21 1800 930 (1800)

23 B20 2 2 4 4325 21 1800 830 (1800)

24a B25 2 2 4 5625 99 1315 2085 1315 225 2315

TYPE-2T 24b B25 2 2 4 5550 99 1245 2085 1245 215 2300

24c B25 2 2 4 5475 99 1175 2085 1175 200 2290

TYPE-WEB 01 B20 1 1 1 13575 77 500 80 9

02a B16 1 1 1 2775 51 380 880 (210) (210)

02b B16 1 1 1 2775 51 380 875 (210) (210)

02c B16 1 1 1 2775 51 380 870 (210) (210)

02d B16 1 1 1 2750 51 380 865 (210) (210)

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
Bending Schedule Drawing No. Page No. Revision

40 2 of 2 B

CEBU-CORDOVA LINK EXPRESSWAY PROJECT Revision

PRESTRESSING BLISTERS - 2 Orig/Date AGM 10/04/2020

ISSUED FOR CONSTRUCTION Ch.d by/D JMR 10/04/2020

Location Bar Type Number Number Total Length Shape All bending dimensions are in accordance with
mark and of in each number of each code BS8666:2005
Size groups bar A B C D E/r REV

mm mm mm mm mm
TYPE-WEB 02e B16 1 1 1 2750 51 380 860 (210) (210)

02f B16 1 1 1 2725 51 380 855 (210) (210)

02g B16 1 1 1 2725 51 380 845 (210) (210)

02h B16 1 1 1 2700 51 380 840 (210) (210)

05a B16 1 1 1 1950 51 300 545 (210) (210)

05b B16 1 1 1 1925 51 300 525 (210) (210)

05c B16 1 1 1 1875 51 300 505 (210) (210)

05d B16 1 1 1 1825 51 300 485 (210) (210)

05e B16 1 1 1 1800 51 300 465 (210) (210)

05f B16 1 1 1 1750 51 300 445 (210) (210)

05g B16 1 1 1 1725 51 300 425 (210) (210)

05h B16 1 1 1 1675 51 300 405 (210) (210)

06 B25 1 2 2 8175 99 800 920 4650 1800

TYPE-WEB 29 B20 1 2 2 6250 41 350 2450 850 2450 (350)

B=Steel reinforcement grade B500B to BS4449 2005


S=Stainless steel reinforcement Type 1.4301 to IS EN 10088
X=For Steel other than H and S
REINFORCEMENT

1. REINFORCING BARS, INCLUDING HELICAL REINFORCEMENT, BUT NOT FABRIC


REINFORCEMENT AND DOWELS ARE SCALED UP ON THE DRAWINGS IN THE FOLLOWING
MANNER:
NO OFF: BAR TYPE: BAR DIAMETER - BAR MARK - PITCH: POSITION AND/OR COMMENT
E.G. 7 H20 09-125-B1
BAR TYPE DESIGNATION IS AS FOLLOWS:
B = GRADE B500B OR B500C RIBBED BARS COMPLYING WITH BS 4449
S = GRADE 1.4301 STAINLESS STEEL REINFORCEMENT COMPLYING WITH
BS EN 10088-1
POSITION/COMMENT IS DESIGNATED AS FOLLOWS:
T = TOP FACE, B = BOTTOM FACE, NF = NEAR FACE, FF = FAR FACE
ABR = ALTERNATE BARS REVERSED
STG = ALTERNATE BAR STAGGERED BY THE AMOUNT SHOWN
ALT = ALTERNATE BARS
COUPLER = BAR END INDICATED TO BE SWAGED FOR SCREW TYPE COUPLER
WHERE TWO BAR MARKS ARE SCALED UP TOGETHER AND IDENTIFIED AS "AB", THE
SPACING STATED IS THE SPACING OF ALL BARS NOT OF EACH BAR MARK.
2. WHERE REINFORCEMENT COUPLERS ARE USED, THEY SHALL BE POSITIONED
SO AS TO ACHIEVE THE SAME NOMINAL COVER AS THAT SPECIFIED FOR THE
REINFORCEMENT BARS WHICH THEY COUPLE.
3. STEEL SPACERS OF SIMILAR DIAMETER TO BARS BUT NOT LESS THAN 25 DIAMETER
SHALL BE PROVIDED BETWEEN ADJACENT LAYERS OF PARALLEL REINFORCEMENT AND
SPACED AT NO MORE THAN 6 0 TIMES THE SMALLER BAR DIAMETER.
GALVANIZED J-BOLTS DRAINAGE DETAIL THESE SPACER BARS ARE NOT INCLUDED ON THE BAR SCHEDULES.
4. SPACERS, TIES AND STOOLS SHALL BE SUPPLIED BY
DETAIL SCALE 1:5 THE CONTRACTOR AS NECESSARY TO SECURE THE REINFORCEMENT
SCALE 1:5 AGAINST DISPLACEMENT .
5. PVC DUCTS ARE TO BE INSTALLED PRIOR TO CAST THE HANDRAIL.
SEE DRAWINGS D630-ST-DJV-DRA-534901 & D630-ST-DJV-DRA-534903

GENERAL NOTES

CONCRETE CLASS 50 (MPa)


CONCRETE COVER: 50mm
CONCRETE COVER IN CONTACT WITH CONCRETE: 10mm

CALLOUT SHALL BE READ AS SHOWN BELOW REFERENCE DRAWINGS


REINFORCEMENT
LIGHTING ANCHORAGE STEEL GRADE
GENERAL NOTES
D630-ST-DJV-DRA-534106
LOCAL REINFORCEMENT D630-ST-DJV-DRA-534107
SCALE 1:5 GEOMETRY PRESTRESSING

LAYER

* WHEN ONLYONE IDENTIFICATION: PRECAST


XXX BAR MARK

DRAINAGE
LOCAL REINFORCEMENT
SCALE 1:5
LIGHTING ANCHORAGE
LOCAL REINFORCEMENT
SCALE 1:5

SCHEME

SUBCONTRACTOR: PROJECT: SCALE


REVISIONS
X NO. DATE DESCRIPTION BACK SPAN
A 20/03/2020 ISSUED FOR CONSTRUCTION SUPERSTRUCTURE
B DECK REINFORCEMENT
T1 & T2 -S5-b DRAINAGE & LIGTHING
BY: DJV C

DATE: 200416 D
A
SIGNATURE E D630-ST-CFC-SHD-8176 41

You might also like