You are on page 1of 1

1 2 3 4 5

2500
3500 5000 3500

A General Notes
C2 C2 C2 C2
1. The structure is analyzed &
1800
designed for dead load, live
load, seismic load (Zone-
IV), Wind load (Basic wind

1500
4166 speed i.e. 50 m/s).
2. All dimensions are in
16mm dia 150mm spacing c/c millimeter (mm).
3. S.B.C of soil is taken as 98
kN/m² at 1.5 m from G.L.
4. Concrete Mix Design: M20
B 5. Grade of Steel: Fe550
C1 C1 Conforming to IS 1786 -
2008.
6. Effective cover to main
reinforcement:
Footing -50 mm, Column
4166 -40 mm, Beam -30 mm,
Chajja -20 mm
7. Lap length for all bars shall
be 56 times diameter of the
bar.
8. Anchorage length provided
C at the exterior column
C1 C1 beyond the inner face of the
columns should be of
length equals to
development length of bar
in tension (Ld) plus 10
4166
times diameter of the bar.

(i.e. Ld+10db)
152
400

2300
9. Hook length should be
equal to 6d, or more than 65
180

D mm.
C1 C1 10.Do not scale drawing.
11.No changes shall be
2130

made without the consent


of the Engineer in-charge.
5600

180

4166
1060 1060
2130
180
152 400

E
C1 C1
76 76
560 180 560

4166

F
C2 C2 C2 C1

Approved by,

4166

Project Name

C2 C2 C2
G Drawn Drawing

Date COLUMN
CENTERLINE
Scale