Footing parameters will differ with varying soil conditions and wind loadings. Local building approval authorities have differing
requirements for the size and depth of footings. It is important that anyone designing and constructing a building seek expert
advice from a structural engineer on the requirements specific to each building.
The following information on footings is a general guide only and not a substitute for expert advice.
100mm min
(may be precast)
NOTES:
1. Footings to be designed to AS 2870: Residential slabs and footings. Depth of
footing Df from AS 2870.
2. The effective area supported by a pad footing is the sum of: (a) the supported
floor area; (b) the supported roof area (if applicable); and (c ) half the supported
wall area in elevation (if applicable).
3. Pad footings should be finished 50mm above ground level as shown by “A”.
4. Where backfilling is required (shown by “B”) the concrete for the pad needs
to be raised 50mm above the finish ground line.
5. Where piers are embedded into the pads as shown by “C” it is required to
apply a barrier coating to a minimum of 100mm above expected final
concrete height. The pier bottom connection is also to be painted all round
as specified above.
6. Suggested Coatings: Jotun conceal touch up. Preparation and application to
paint manufacturer’s specification.
Steel Centre
21 Note: InfraBuild Steel Centre reserve the right to change specifications without notice.